• 제목/요약/키워드: Ground Length

검색결과 1,141건 처리시간 0.024초

설계조건 변화에 따른 지중열교환기 길이 변화 연구 (Study on Capacity Alteration of Geothermal Heat Exchanger by Changing Design Condition)

  • 박종일;박경순
    • 한국지열·수열에너지학회논문집
    • /
    • 제9권4호
    • /
    • pp.9-14
    • /
    • 2013
  • A ground loop heat exchanger for the ground source heat pump system is the important equipment determining the thermal performance and initial cost of the system. The length and performance of the underground heat exchanger is dependent on ground thermal conductivity, operation hours, ground loop diameter, grout, ground loop arrangement, pipe placement and design temperature. In this study we find out heat exchanger length with various design factor.

Correlation among Functional Leg Length Discrepancy, Muscle Activity, Muscle Contraction Onset Time and Vertical Ground Reaction Force during Simple Lifting Task

  • Jin, Ha Young;Han, Jin Tae
    • The Journal of Korean Physical Therapy
    • /
    • 제34권4호
    • /
    • pp.175-180
    • /
    • 2022
  • Purpose: Leg length discrepancy causes the posture deformation, gait asymmetry, and lower back pain. The purpose of this study is to investigate the correlation among functional leg length discrepancy (FLLD), muscle activity, muscle contraction onset time and vertical ground reaction force (vGRF) during simple lifting task. Methods: Thirty-nine subjects participated in this study. FLLD was measured from the umbilicus to medial malleolus of left and right leg using a tape. The subjects performed to lift a 10 kg box from the floor to chest. The muscle activity and muscle contraction onset time of rectus abdominis, erector spinae and rectus femoris was measured using EMG system and vGRF was measured by two force plate. Pearson correlation was used to fine out the correlation among FDDL, muscle activity, muscle contraction onset time and vGRF during simple lifting task. Results: Correlation between FLLD and difference of muscle activity of short-long side was very high (r>0.9) during simple lifting task. Correlation between FLLD and difference of muscle contraction onset time of short-long side was very high (r>0.9) during simple lifting task. And correlation between FLLD and difference of vGRF of short-long side was high (r>0.7) during simple lifting task. Conclusion: This study suggests that there is high correlation between FLLD and muscle activity, muscle contraction onset time, and ground reaction force during simple lifting task. Therefore, FLLD could negatively affect the postural balance.

그라우트 재료별 열응답 특성 및 열교환기 운전온도 변화 (Thermal Response Property of Grout Materials from In-situ Test and Temperature Variation of Ground Heat Exchanger)

  • 김갑득;이성주;윤여상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.769-775
    • /
    • 2008
  • The objective of this report is to determine the difference of thermal response that grouted two different materials, and compare the simulation result of the length of total ground heat exchanger length that using the ground thermal conductivity. And also to know heat exchange variation of ground heat exchanger temperature that measured with various test depth. The result shows that the test hole grouted with water permeable material got better thermal response than grouted with water impermeable material. However, with consideration of ingnore for the initial 12 hour data, the test hole grouted with impermeable material has larger thermal conductivity than the other. By former thermal conductivity, simulated data by engineering program shows only 3.4% difference or less. This result shows that ground thermal conductivity is not the main variables for the design program of ground heat exchanger. At the cooling or heating mode, base on the depth of -150m, the ground heat exchanger has best temperature at $-90{\sim}-60m$ and than getting worse because of entering water heat exchanged with leaving water in the same hole.

  • PDF

대형 봉상 접지전극의 길이에 따른 뇌 임펄스 특성 (Lightning impulse characteristics of large-scale ground rods with different length)

  • 이복희;장근철;엄주홍;김병근;정동철;길형준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.233-235
    • /
    • 2003
  • To obtain a low ground resistance in high resistivity soil or in insufficient place such as downtown, long vertical ground rods are often used. However, if the lightning current or fault current with high frequency flows into the grounding system, the ground impedance is significantly increased. This paper presents how the impulse current works on the long vertical ground rods with a different length. As a result, it can be estimated what the waveform is composed of and how the GPR is affected by the rate of current change.

  • PDF

일반 가설앵커의 문제점과 개선방향 (Ground Anchor Testing on Temporary Excavations)

  • 김성규;김낙경;김정렬
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.545-552
    • /
    • 2003
  • For temporary excavation support in a congested urban area, the strand of ground anchor should be removed to get permission of the private land to install anchors. But the strand doesn't need to be removed in the outside city area after use. So the anchor body, tension anchor, is fabricated in-situ. The unbonded length of This anchor has several strands, which wrap only one sheath. When the anchor body is carried into job-site or installed in the bore hole, the sheath is torn easily because it is a very week material. So the grout permeate into the torn sheath. Because of that, the load doesn't transfer to the bond length of ground anchors. It may indicate that load is being transferred along the unbonded length and thus within the potential slip surface assumed for overall stability of the anchored system. The load tests were performed on seven low-pressure grouted anchors installed in weathered soil to verify its problems. Four anchors(Type A) have the unbonded length, which consist of five strands and a week sheath and three anchors(Type B) have strands, which is covered by plastic sheath filled with grease, in the unbonded length. Both anchors are compared with load tests results.

  • PDF

접지시스템의 설계를 위한 대지저항률의 합리적인 측정방법 고찰 (Examinations on the Reasonable Measuring Methods of the Soil Resistivity for Design of Grounding System)

  • 이복희;김기복;이승훈;최종혁
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.35-41
    • /
    • 2011
  • In order to design effectively the grounding system, it is very important to determine the optimum soil resistivity at the desired location of the connection to earth. This paper deals with the reasonable methods of measuring the soil resistivity where grounding electrodes are buried. The soil resistivity at three test sites with different resistivity of soil were measured as functions of the spacing between the test probes in the Wenner's four-point method and the length of test ground rod in the three-point method. In the case of the three-point method, the length of test ground rod of 2-10[m] in length was appropriate in two-layered soil structure. In the length range of 2-10[m], the results measured by the three-point method using the test ground rod with the length corresponding to the spacing between the test probes of the Wenner's four-point method are in good agreement with the data obtained from the Wenner's four-point method.

풍화토 정착 인장형 앵커에서 주면전단거동분석을 위한 다중선형모델 적용 해석기법의 제안 (Suggestion of Analytical Technique Applying Multi-Linear Models for Analysis of Skin Shear Behavior of Tension-Type Ground Anchors in Weathered Soil)

  • 정현식;이영생
    • 한국지반공학회논문집
    • /
    • 제34권11호
    • /
    • pp.5-19
    • /
    • 2018
  • 지반앵커의 정착장에 작용하는 정착응력 분포 특성은 매우 비선형적이며 공학적인 메카니즘이 비교적 복잡하기 때문에 다양한 지반조건 및 비선형적 주면전단거동을 구체적으로 모사하여 지반앵커를 설계하는데 어려움이 크다. 이런 한계로 인하여 현재 대부분의 관련 설계 기준서에는 편의상 정착장 전장에 걸쳐 일정한 주면전단응력분포를 가정하여 설계에 적용하고 있다. 따라서 본 연구에서는 인장형 앵커의 인발거동 특성을 분석하기 위하여 풍화토 지반조건을 대상으로 현장인발시험을 수행하였으며 이를 토대로 앵커 정착장의 주면전단거동을 정립하고, 정착장 거동특성을 비교적 간편하게 예측하기 위한 다중선형모델 및 이를 적용한 해석적 기법을 제안하였다. 현장시험결과와 해석적 결과가 상호 유사하게 나타남에 따라 본 연구에서 제시된 다중선형모델 및 이를 이용한 해석적 기법의 적용성 및 유효성을 확인할 수 있었다. 정착장 주면전단거동의 경우 최대인발하중 보다 작은 하중조건에서는 정착장 시작점에서 최대전단응력이 분포하게 되나 최대인발하중이 발생한 이후부터는 정착장 시작점에서 전단응력이 가장 작게 분포하고, 정착장 시작점으로부터 일정거리 이격된 지점에서 최대전단응력이 발생함을 확인하였다.

쏘일네일의 길이평가를 위한 비파괴 기법의 적용 (Application of non-destructive method for evaluation of soil nail length)

  • 김기홍;김낙영;이종섭;유정동
    • 한국터널지하공간학회 논문집
    • /
    • 제17권2호
    • /
    • pp.75-90
    • /
    • 2015
  • 쏘일네일은 지반과 네일간에 발생하는 마찰특성을 이용하여 지반을 보강하기 때문에 쏘일네일의 길이는 지반의 안정성에 매우 중요한 요소이다. 이와 같은 이유로 쏘일네일의 길이를 정확히 평가하여 지반의 안정성을 확보해야 한다. 본 연구는 쏘일네일의 길이를 평가하는 기법을 개발하기 위한 기초 연구로써 비파괴기법의 적용성을 제시하고자 한다. 첫째, 커플러로 연결된 철근에도 적용 가능한 기법을 개발하기 위해 초음파와 전자기파를 적용한 실험을 수행하였다. 실험 결과, 초음파는 커플러의 영향으로 신호를 측정할 수 없는 반면, 전자기파의 경우 커플러의 영향 없이 신호를 측정할 수 있었다. 둘째, 쏘일네일의 길이에 따른 전자기파 신호양상을 파악하기 위해 1 m~15 m의 길이가 되도록 철근을 조합한 후, 전자기파를 측정하였다. 그 결과, 철근의 길이가 증가할수록 전자기파의 도달시간이 증가하는 것으로 나타났다. 또한, 기 설치된 쏘일네일에도 적용할 수 있도록 접지선을 이용한 실험도 수행하였다. 실험결과, 접지선을 이용한 경우에도 철근의 길이가 증가할수록 전자기파의 도달시간도 증가하는 것으로 나타났다. 본 연구의 결과는 전자기파가 쏘일네일의 길이를 평가하기에 유용한 기법임을 보여준다.

비선형해석을 이용한 케이싱 보강조건에 따른 대구경 현장타설말뚝의 수평거동특성 (Lateral Bearing Characteristics of Large Diameter Drilled Shafts by Casing Reinforcement Condition Using Non Linear Analysis)

  • 유진호;문인종;이강일
    • 한국지반신소재학회논문집
    • /
    • 제19권3호
    • /
    • pp.23-33
    • /
    • 2020
  • 대구경 현장타설말뚝의 경우 수평지지특성은 중요한 요소이며 이를 증가시키기 위한 방안은 말뚝의 인접지반을 개량하여 강성을 증가시키는 방법과 말뚝 자체의 강성을 증가시키는 방법이 있다. 이중 말뚝체에 케이싱을 보강하여 강성을 증가시키는 방법이 많이 제안되고 있는 추세이지만 이와 관련된 연구는 거의 이루어지지 않고 있는 실정이다. 따라서 본 연구에서는 지반조건에 따라 대구경 현장타설말뚝의 적정 케이싱 보강길이를 평가하기 위해 비선형해석을 이용하여 지반조건별로 케이싱 보강길이에 따른 수평지지특성을 연구하였다. 그 결과 대구경 현장타설말뚝의 수평지지특성은 케이싱 보강 길이비(κ)가 1.2인 경우 가장 효과적이며 지반조건에 따라서는 느슨한 지반일수록 큰 보강효과를 나타내었다.

BTR공법의 시공단계별 안전성 해석 (A Safety Analysis of the BTR Method by Construction Sequence)

  • 정광모;이원희;이상헌;방명석
    • 대한안전경영과학회지
    • /
    • 제14권1호
    • /
    • pp.101-108
    • /
    • 2012
  • In this study was conducted numerical analysis to evaluate the stability of BTR(Built-in Timber Roof Tunneling Method), which is one of construction methods of underground structures in the non-opening state. The discretion method was applied to individually model reinforcing members of BTR, and the homogeneity analysis technic by area ratio was used to verify the feasibility comparing this result with that from conventional analysis method. The parameter study was performed to evaluate the effect varying ground depth, distance length of reinforcing supports and to verify the field applicability of new analysis method. The results showed the very precise value with allowable error, so this method can be applied in the field, The more length of supporting members caused the more vertical displacement and the top displacement increment of support members is larger than that of ground surace. The effect of ground depth was more impressive than that of distance length of reinforcing supports.