• Title/Summary/Keyword: Grid-connected Wind Generation

Search Result 107, Processing Time 0.036 seconds

An Effective Control Scheme of a Back-to-Back Converter with Shunt-Connected HTS SMES for Frequency Regulation of an Islanded Microgrid

  • Dinh, Minh-Chau;Park, Minwon;Kim, Gyeong-Hun;Yu, In-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.1119-1124
    • /
    • 2014
  • High temperature superconducting magnetic energy storage (HTS SMES) is known as an effective solution to significantly decrease the voltage and power fluctuations of grid connected wind power generation system (WPGS). This paper implements an effective control scheme of a back-toback converter with shunt-connected HTS SMES for the frequency regulation of an islanded microgrid. The back-to-back converter is used to connect the WPGS to the grid. A large-scale HTS SMES is linked to the DC side of the back-to-back converter through a two-quadrant DC/DC chopper. An adaptive control strategy is implemented for the back-to-back converter and the two-quadrant DC/DC chopper to improve the efficiency of the whole system. The performance of the proposed control system was evaluated in a test power system using PSCAD/EMTDC. The simulation results clearly show that the back-to-back converter with shunt-connected HTS SMES operates effectively with the proposed control strategy for stabilizing the power system frequency fluctuations.

Factors Influencing Transient Stability in Network Connected to Wind Power Generation System (풍력발전시스템이 연계된 계통의 과도안정성에 영향을 미치는 요소)

  • Kim, Se-Ho;Oh, Sung-Bo;Ko, Seoung-Min;Ahn, Jae-Hyun;Lee, Soo-Mook;Jang, Si-Ho;Lee, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.535-536
    • /
    • 2006
  • This paper reports investigation into the factors that influence the transient behavior of the wind power generation system following network fault conditions. It is shown that the critical clearing time(CCT) can be affected by various factors contributed by the host network. Such factors include capacity of wind power, power factor, the length of the interfacing line, etc. This investigation is conducted en a simulated grid-connected wind farm using Digsilent Power Factory.

  • PDF

A Hysteresis Current Controller for PV-Wind Hybrid Source Fed STATCOM System Using Cascaded Multilevel Inverters

  • Palanisamy, R.;Vijayakumar, K.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.270-279
    • /
    • 2018
  • This paper elucidates a hysteresis current controller for enhancing the performance of static synchronous compensator (STATCOM) using cascaded H-bridge multilevel inverter. Due to the rising power demand and growing conventional generation costs a new alternative in renewable energy source is gaining popularity and recognition. A five level single phase cascaded multilevel inverter with two separated dc sources, which is energized by photovoltaic - wind hybrid energy source. The voltages across the each dc source is balanced and standardized by the proposed hysteresis current controller. The performance of STATCOM is analyzed by connecting with grid connected system, under the steady state & dynamic state. To reduce the Total Harmonic Distortion (THD) and to improve the output voltage, closed loop hysteresis current control is achieved using PLL and PI controller. The performance of the proposed system is scrutinized through various simulation results using matlab/simulink and hardware results are also verified with simulation results.

A Method to Calculate Flicker Emission of a Grid-Connected Wind Turbine System (계통연계 풍력발전 시스템의 플리커 지수 계산방법)

  • Ahn, Duck-Keun;Ro, Kyoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.310-312
    • /
    • 2002
  • The development of IEC 61400-21 provides firm basis for assessment of the impact of wind turbines on voltage quality. This paper presents analysis and modeling of the flicker emission of wind turbines. The paper concentrates on the theoretical aspects of the flicker algorithm, wind turbine characteristics and the generation of flicker during continuous operation of wind turbines. It also introduces a simplified assessment to limit the flicker emission.

  • PDF

Modeling and Analysis of Control Scheme for Voltage Source Inverter Based Grid-connection of Wind Turbine (전압원인버터를 이용한 계통연계형 풍력발전의 출력제어 모의 및 해석)

  • 김슬기;김응상
    • Journal of Energy Engineering
    • /
    • v.12 no.2
    • /
    • pp.154-163
    • /
    • 2003
  • Grid connection essentially requires a wind energy conversion system (WECS) to not only supply adequate power responding to constantly varying wind speed but also provide a specified level of voltage magnitude and frequency that is acceptable in the electric power network. To satisfy such requirements, appropriate control schemes of a wind turbine to be connected to the power grid should be employed. This paper presents an output control strategy of a grid-connected wind power generation, which consists of a fixed-pitch wind turbine, a synchronous generator and a AC-DC-AC component with a voltage source inverter built in, and performs modelling and analysis of the strategy using PSCAD/EMTDC, an electromagnetic transient analysis software. Real power output control of the voltage source inverter is implemented to extract the maximum energy from wind speed inputted through wind blades and reactive power control, to keep the terminal voltage of WECS at a specific level. SPWM switching method is used to reduce the harmonics and maintain 60 ㎐ of the output frequency. The wind turbine performance and output corresponding to wind variation and the terminal load change is simulated and analysed.

Implementation and Control of AC-DC-AC Power Converter in a Grid-Connected Variable Speed Wind Turbine System with Synchronous Generator (동기기를 사용한 계통연계형 가변속 풍력발전 시스템의 AC-DC-AC 컨버터 구현 및 제어)

  • Song Seung-Ho;Kim Sung-Ju;Hahm Nyon-Kun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.12
    • /
    • pp.609-615
    • /
    • 2005
  • A 30kW electrical power conversion system is developed for a variable speed wind turbine. In the wind energy conversion system(WECS) a synchronous generator with field current excitation converts the mechanical energy into electrical energy. As the voltage and the frequency of the generator output vary according to the wind speed, a 6-bridge diode rectifier and a PWM boost chopper is utilized as an ac-dc converter maintaining the constant dc-link voltage with only single switch control. An input current control algorithm for maximum power generation during the variable speed operation is proposed without any usage of speed sensor. Grid connection type PWM inverter converts dc input power to ac output currents into the grid. The active power to the grid is controlled by q-axis current and the reactive power is controlled by d-axis current with appropriate decoupling. The phase angle of utility voltage is detected using software PLL(Phased Locked Loop) in d-q synchronous reference frame. Experimental results from the test of 30kW prototype wind turbine system show that the generator power can be controlled effectively during the variable speed operation without any speed sensor.

Linear Programming based Optimal Scheduling for Grid-connected Microgrid (선형계획법에 의한 계통연계형 마이크로그리드의 최적 운용에 관한 연구)

  • Park, Jae-Sae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1622-1626
    • /
    • 2011
  • Recently, interests on microgrids have been growing as clean power systems. Microgrids include small scaled distributed generation such as wind and solar power as well as diesel generators as main power sources. To operate a microgrid effectively, optimal scheduling for the microgrid is important. Especially, in the grid-connected mode, power trades between the microgrid and the power grid should be considered in optimal scheduling. In this paper, mathematic models for optimal operation of a microgrid were established based on the linear programming. In particular, the shiftable load was considered in the models to optimize it in microgrid operation. To show feasibility of the proposed models, they were applied to optimal microgrid operation and the results were discussed.

Steady-State Performance Analysis of an Integrated Wind Turbine Generating System in a DC Transmission System with Power Compensation System

  • Yamashita, Ken-Ichiro;Nishikata, Shoji
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.1
    • /
    • pp.121-127
    • /
    • 2012
  • An electric power compensation system for a DC transmission system with an integrated wind turbine generator is proposed. The proposed compensation system consists of a synchronous generator and a duplex reactor. This apparatus is connected to the sending-end circuit of the DC transmission system. A set of steady-state equations of the system is first derived. Then, the effect of the duplex reactor, which can eliminate the sending-end grid current distortion due to commutation of the converter, is explored. The relationships among power at the sending-end circuit are also revealed. It is shown that fluctuations in the sending-end grid power due to changes in wind velocities are compensated with the proposed system. Finally, the effects of the sending-end grid conditions on the steady-state characteristics of the system are studied.

Optimal unidirectional grid tied hybrid power system for peak demand management

  • Vineetha, C.P.;Babu, C.A.
    • Advances in Energy Research
    • /
    • v.4 no.1
    • /
    • pp.47-68
    • /
    • 2016
  • A well designed hybrid power system (HPS) can deliver electrical energy in a cost effective way. In this paper, model for HPS consisting of photo voltaic (PV) module and wind mill as renewable energy sources (RES) and solar lead acid battery as storage device connected to unidirectional grid is developed for peak demand reduction. Life time energy cost of the system is evaluated. One year hourly site condition and load pattern are taken into account for analysing the HPS. The optimal HPS is determined for least life time energy cost subject to the constraints like state of charge of the battery bank, dump load, renewable energy (RE) generation etc. Optimal solutions are also found out individually for PV module and wind mill. These three systems are compared to find out the most feasible combination. The results show that the HPS can deliver energy in an acceptable cost with reduced peak consumption from the grid. The proposed optimization algorithm is suitable for determining optimal HPS for desired location and load with least energy cost.

Analysis of Dynamic Characteristics for Doubly-Fed Induction Generator in Wind Turbine System based on Stiffness of Linked System (연계계통의 강인성에 따른 이중여자유도발전 풍력시스템의 동특성 해석)

  • Kim, Tae-Ho;Ro, Kyoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.458_459
    • /
    • 2009
  • This paper analyzes the dynamic characteristics for doubly-fed induction generator(DFIG) in wind turbine system. This paper presents a modeling and simulation of a grid-connected wind turbine generation system for dynamics analysis on MATLAB/Simulink, and analyzes the responses DFIG wind turbine system for stiffness of linked system. Simulation results show the variations of generator's active/reactive output, terminal voltage, fault current, etc.

  • PDF