• Title/Summary/Keyword: Grid type

Search Result 823, Processing Time 0.027 seconds

A Study on Hybrid type Grid-Connected PV Inverter using Elevator Regeneration Power (엘리베이터 회생전력을 이용한 하이브리드 태양광 연계형 인버터에 관한 연구)

  • Cho, Su-Eog
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1682-1687
    • /
    • 2016
  • Approximately 520thousand elevators are operating now in Korea, about 40% ~ 60% of the elevator power is generated. In this paper, by using the method of adding regeneration power of the elevator to the grid-tied photo voltaic inverter, PV generation that was dependant on the solar radiation was significantly improved. In order to confirm this, the regeneration power of the elevator has been simulated in 12% of the rating load, and measured the regeneration power of the elevator in the actual condition to assess the differences of it. The 5[kW] hybrid grid-tied photo voltaic invertor has been fabricated to conduct an experiment for the confirmation of the proposing method. The effectiveness of the proposing method has been reassured with the result of experiment that include the transfer interface part of the regeneration power of the elevator.

Large eddy simulation using a curvilinear coordinate system for the flow around a square cylinder

  • Ono, Yoshiyuki;Tamura, Tetsuro
    • Wind and Structures
    • /
    • v.5 no.2_3_4
    • /
    • pp.369-378
    • /
    • 2002
  • The application of Large Eddy Simulation (LES) in a curvilinear coordinate system to the flow around a square cylinder is presented. In order to obtain sufficient resolution near the side of the cylinder, we use an O-type grid. Even with a curvilinear coordinate system, it is difficult to avoid the numerical oscillation arising in high-Reynolds-number flows past a bluff body, without using an extremely fine grid used. An upwind scheme has the effect of removing the numerical oscillations, but, it is accompanied by numerical dissipation that is a kind of an additional sub-grid scale effect. Firstly, we investigate the effect of numerical dissipation on the computational results in a case where turbulent dissipation is removed in order to clarify the differences between the effect of numerical dissipation. Next, the applicability and the limitations of the present method, which combine the dynamic SGS model with acceptable numerical dissipation, are discussed.

Improved Contrast for Threshold Random-grid-based Visual Cryptography

  • Hu, Hao;Shen, Gang;Fu, Zhengxin;Yu, Bin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.7
    • /
    • pp.3401-3420
    • /
    • 2018
  • Pixel expansion and contrast are two major performance parameters for visual cryptography scheme (VCS), which is a type of secret image sharing. Random Grid (RG) is an alternative approach to solve the pixel expansion problem. Chen and Tsao proposed the first (k, n) RG-based VCS, and then Guo et al., Wu et al., Shyu, and Yan et al. significantly improved the contrast in recent years. However, the investigations on improving the contrast of threshold RG-based VCS are not sufficient. In this paper, we develop a contrast-improved algorithm for (k, n) RG-based VCS. Theoretical analysis and experimental results demonstrate that the proposed algorithm outperformers the previous threshold algorithms with better visual quality and a higher accuracy of contrast.

NUMERICAL REQUIREMENTS FOR THE SIMULATION OF DETONATION CELL STRUCTURES (기체 상 데토네이션 셀 구조 해석을 위한 수치적 요구 조건)

  • Choi, Jeong-Yeol;Cho, Deok-Rae;Lee, Su-Han
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.04a
    • /
    • pp.177-181
    • /
    • 2007
  • Present study examines the numerical issues of cell structure simulation for various regimes of detonation phenomena ranging from weakly unstable to highly unstable detonations. Inviscid fluid dynamics equations with $variable-{\gamma}$ formulation and one-step Arrhenius reaction model are solved by a MUSCL-type TVD scheme and 4th order accurate Runge-Kutta time integration scheme. A series of numerical studies are carried out for the different regimes of the detonation phenomena to investigate the computational requirements for the simulation of the detonation wave cell structure by varying the reaction constants and grid resolutions. The computational results are investigated by comparing the solution of steady ZND structure to draw out the minimum grid resolutions and the size of the computational domain for the capturing cell structures of the different regimes of the detonation phenomena.

  • PDF

Optimal Engineering of MicroGrid on the Environmental Cost and Operation Type (환경비용 및 운용방식을 고려한 마이크로그리드 최적 엔지니어링 연구)

  • Park, Jung-Sung;Shin, Hye-Kyeong;Lee, Duck-Su;Lee, Hak-Seong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.369-371
    • /
    • 2008
  • Environmental issue is one of the key factors to industry area using fossil fuels, because it accelerates the global warming. So it is supposed to reduce greenhouse gases around the developed nations of the world at times go. This issue is especially for the power industry. Under this background, CHP system that consists of Distributed Energy Resources (DER) system, such as natural power system (wind, solar) and fuel-cell, co-generation, also known as CHP (Combined heat and power), has been developed greatly during the last 10 years. This paper adopts optimal model using GAMS to develop methods for conducting an integrated assessment of MicroGrid system.

  • PDF

An unwanted facility location problem with negative influence cost and transportation cost (기피비용과 수송비용을 고려한 기피시설 입지문제)

  • Yang, Byoung-Hak
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.77-85
    • /
    • 2013
  • In the location science, environmental effect becomes a new main consideration for site selection. For the unwanted facility location selection, decision makers should consider the cost of resolving the environmental conflict. We introduced the negative influence cost for the facility which was inversely proportional to distance between the facility and residents. An unwanted facility location problem was suggested to minimize the sum of the negative influence cost and the transportation cost. The objective cost function was analyzed as nonlinear type and was neither convex nor concave. Three GRASP (Greedy Randomized adaptive Search Procedure) methods as like Random_GRASP, Epsilon_GRASP and GRID_GRASP were developed to solve the unwanted facility location problem. The Newton's method for nonlinear optimization problem was used for local search in GRASP. Experimental results showed that quality of solution of the GRID_GRASP was better than those of Random_GRASP and Epsilon_GRASP. The calculation time of Random_GRASP and Epsilon_GRASP were faster than that of Grid_GRASP.

Effect of Microstructure on Corrosion Behavior of TiN Hard Coatings Produced by Two Grid-Attached Magnetron Sputtering

  • Kim, Jung Gu;Hwang, Woon Suk
    • Corrosion Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.15-22
    • /
    • 2006
  • The introduction of two-grid inside a conventional process system produces a reactive coating deposition and increases metal ion ratio in the plasma, resulting in denser and smoother films. The corrosion behaviors of TiN coatings were investigated by electrochemical methods, such as potentiodynamic polarization test and electrochemical impedance spectroscopy (EIS) in deaerated 3.5% NaCl solution. Electrochemical tests were used to evaluate the effect of microstructure on the corrosion behavior of TiN coatings exposed to a corrosive environment. The crystal structure of the coatings was examined by X-ray diffractometry (XRD) and the microstructure of the coatings was investigated by scanning electron microscopy (SEM) and transmission electron spectroscopy (TEM). In the potentiodynamic polarization test and EIS measurement, the corrosion current density of TiN deposited by two grid-attached magnetron sputtering was lower than TiN deposited by conventional magnetron type and also presented higher Rct values during 240 h immersion time. It is attributed to the formation of a dense microstructure, which promotes the compactness of coatings and yields lower porosity.

Evaluation of Ultimate Strength of Reinforced Concrete Deep Beams Using Grid Strut-Tie Model Approach (격자 스트럿-타이 모델 방법을 이용한 철근콘크리트 깊은 보의 극한강도 평가)

  • Kim, Byung-Hun;Lee, Won-Seok;Yun, Young-Mook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.179-182
    • /
    • 2005
  • Recently, many design codes including ACI 318-02 recommend the use of a strut-tie model approach for design of structural concrete with D-region(s). However, there are several unclear problems and shortcomings in the codes' strut-tie model approach. A grid strut-tie model approach was proposed to resolve these problems. In this study, the ultimate strengths of 17 deep beams, the most familiar type of D-regions, were evaluated for the validity check of the grid strut-tie model approach. The analytical results obtained by the approach are compared with those by the strut-tie model approach presented by CEB-FIP, AASHTO LRFD, and ACI 318-02.

  • PDF

A study on sub-nanosecoand pulser characteristic of electron gun (서브 나노초의 전자총 펄서 특성에 관한 연구)

  • Son, Y.G.;Jang, S.D.;Oh, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1662-1664
    • /
    • 2003
  • An electron gun system for a nanosecond pulse linac has been built and tested. The gun grid is driven with a grid pulser, which consists of an avalanche transistor pulser and parallel triode amplifier. The amplifier is installed in an end hole of the electron gun and provided for power amplification and polarity change of the output pulses of the avalanche transistor pulser. An output pulse of 200 V and 2 ns FWHM was obtained by using the grid pulser of can type transistors. Measurements with a test bench show that the electron gun can deliver 2ns pulse with with currents larger than 3A.

  • PDF

Direct Power Control Scheme of Improved Command Tracking Capability for PMSG MV Wind turbines

  • Kwon, Gookmin;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.361-362
    • /
    • 2015
  • This paper proposes a Direct Power Control (DPC) scheme of improved command tracking capability for Permanent Magnet Synchronous Generator (PMSG) Medium Voltage (MV) Wind Turbines. Benchmarking is performed based on a neutral point clamped three-level back-to-back type voltage source converter. It is introduced to design the DPC modeling and propose DPC scheme of a three-level NPC (3L-NPC) converter. During the fault condition in wind farms, the proposed control scheme directly controls the generated output power to the command value from the hierarchical wind farm controller. The proposed control scheme is compared with conventional control scheme as respect to loss and thermal analysis. The DPC scheme of improved command tracking capability is confirmed through PLECS simulations. Simulation result shows that proposed control scheme achieves a much shorter transient time in a step response of generated output power. The proposed control scheme makes it possible to provide a good dynamic performance for PMSG MV wind turbine to generate a high quality output power under grid fault condition.

  • PDF