• Title/Summary/Keyword: Grid effects

Search Result 623, Processing Time 0.028 seconds

Hierarchical Voltage Control of a Wind Power Plant Using the Adaptive IQ-V Characteristic of a Doubly-Fed Induction Generator

  • Kim, Jinho;Park, Geon;Seok, Jul-Ki;Lee, Byongjun;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.504-510
    • /
    • 2015
  • Because wind generators (WGs) in a wind power plant (WPP) produce different active powers due to wake effects, the reactive power capability of each WG is different. This paper proposes a hierarchical voltage control scheme for a WPP that uses a WPP controller and WG controller. In the proposed scheme, the WPP controller determines a voltage error signal by using a PI controller and sends it to a doubly-fed induction generator (DFIG). Based on the reactive current-voltage ($I_Q-V$) characteristic of a DFIG, the DFIG injects an appropriate reactive power corresponding to the voltage error signal. To enhance the voltage recovery capability, the gains of the $I_Q-V$ characteristic of a DFIG are modified depending on its reactive current capability so that a DFIG with greater reactive current capability may inject more reactive power. The proposed scheme enables the WPP to recover the voltage at the point of common coupling (PCC) to the nominal value within a short time after a disturbance by using the adaptive $I_Q-V$ characteristics of a DFIG. The performance of the proposed scheme was investigated for a 100 MW WPP consisting of 20 units of 5 MW DFIGs for small and larger disturbances. The results show the proposed scheme successfully recovers the PCC voltage within a short time after a disturbance.

Assessing Climate Change Impacts on Hydrology and Water Quality using SWAT Model in the Mankyung Watershed (SWAT 모형을 이용한 기후변화에 따른 만경강 유역에서의 수문 및 수질 영향 평가)

  • Kim, Dong-Hyeon;Hwang, Syewoon;Jang, Taeil;So, Hyunchul
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.6
    • /
    • pp.83-96
    • /
    • 2018
  • The objective of this study was to estimate the climate change impact on water quantity and quality to Saemanguem watershed using SWAT (Soil and water assessment tool) model. The SWAT model was calibrated and validated using observed data from 2008 to 2017 for the study watershed. The $R^2$ (Determination coefficient), RMSE (Root mean square error), and NSE (Nash-sutcliffe efficiency coefficient) were used to evaluate the model performance. RCP scenario data were produced from 10 GCM (General circulation model) and all relevant grid data including the major observation points (Gusan, Jeonju, Buan, Jeongeup) were extracted. The systematic error evaluation of the GCM model outputs was performed as well. They showed various variations based on analysis of future climate change effects. In future periods, the MIROC5 model showed the maximum values and the CMCC-CM model presented the minimum values in the climate data. Increasing rainfall amount was from 180mm to 250mm and increasing temperature value ranged from 1.7 to $5.9^{\circ}C$, respectively, compared with the baseline (2006~2017) in 10 GCM model outputs. The future 2030s and 2070s runoff showed increasing rate of 16~29% under future climate data. The future rate of change for T-N (Total nitrogen) and T-P (Total phosphorus) loads presented from -26 to +0.13% and from +5 to 47%, respectively. The hydrologic cycle and water quality from the Saemanguem headwater were very sensitive to projected climate change scenarios so that GCM model should be carefully selected for the purpose of use and the tendency analysis of GCM model are needed if necessary.

Optimal Reserve Allocation to Maximize Kinetic Energy in a Wind Power Plant

  • Yoon, Gihwan;Lee, Hyewon;Lee, Jinsik;Yoon, Gi-Gab;Park, Jong Keun;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.1950-1957
    • /
    • 2015
  • Modern wind generators (WGs) are forced or encouraged to participate in frequency control in the form of inertial and/or primary control to improve the frequency stability of power systems. To participate in primary control, WGs should perform deloaded operation that maintains reserve power using speed and/or pitch-angle control. This paper proposes an optimization formulation that allocates the required reserve to WGs to maximize the kinetic energy (KE) stored in a wind power plant (WPP). The proposed optimization formulation considers the rotor speed margin of each WG to the maximum speed limit, which is different from each other because of the wake effects in a WPP. As a result, the proposed formulation allows a WG with a lower rotor speed to retain more KE in the WPP. The performance of the proposed formulation was investigated in a 100-MW WPP consisting of 20 units of 5-MW permanent magnet synchronous generators using an EMTP-RV simulator. The results show that the proposed formulation retains the maximum amount of KE with the same reserve and successfully increases the frequency nadir in a power system by releasing the stored KE in a WPP in the case of a disturbance.

Effect of Extremely Low Frequency Electromagnetic Fields (EMF) on Phospholipase Activity in the Cultured Cells

  • Song, Ho-Sun;Kim, Hee-Rae;Ko, Myoung-Soo;Jeong, Jae-Min;Kim, Yong-Ho;Kim, Myung-Cheul;Hwang, Yeon-Hee;Sohn, Uy-Dong;Gimm, Yoon-Myoung;Myung, Sung-Ho;Sim, Sang-Soo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.14 no.6
    • /
    • pp.427-433
    • /
    • 2010
  • This study was conducted to investigate the effects of extremely low frequency electromagnetic fields (EMF) on signal pathway in plasma membrane of cultured cells (RAW 264.7 cells and RBL 2H3 cells), by measuring the activity of phospholipase $A_2$ ($PLA_2$), phospholipase C (PLC) and phospholipase D (PLD). The cells were exposed to the EMF (60 Hz, 0.1 or 1 mT) for 4 or 16 h. The basal and $0.5\;{\mu}M$ melittin-induced arachidonic acid release was not affected by EMF in both cells. In cell-free $PLA_2$ assay, we failed to observe tbe change of $cPLA_2$ and $sPLA_2$ activity. Also both PLC and PLD activities did not show any change in the two cell lines exposed to EMF. This study suggests that the exposure condition of EMF (60 Hz, 0.1 or 1 mT) which is 2.4 fold higher than the limit of occupational exposure does not induce phospholipases-associated signal pathway in RAW 264.7 cells and RBL 2H3 cells.

An Adaptive Setting Method for the Overcurrent Relay of Distribution Feeders Considering the Interconnected Distributed Generations

  • Jang Sung-Il;Kim Kwang-Ho;Park Yong-Up;Choi Jung-Hwan;Kang Yong-Cheol;Kang Sang-Hee;Lee Seung-Jae;Oshida Hideharu;Park Jong-Keun
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.4
    • /
    • pp.357-365
    • /
    • 2005
  • This research investigates the influences of distributed generations (DG), which are interconnected to the bus by the dedicated lines, on the overcurrent relays (OCR) of the neighboring distribution feeders and also proposes a novel method to reduce the negative effects on the feeder protection. Due to the grid connected DG, the entire short-circuit capacity of the distribution networks increases, which may raise the current of the distribution feeder during normal operations as well as fault conditions. In particular, during the switching period for loop operation, the current level of the distribution feeder can be larger than the pickup value for the fault of the feeder's OCR, thereby causing the OCR to perform a mal-operation. This paper proposes the adaptive setting algorithm for the OCR of the distribution feeders having the neighboring dedicated feeders for the DG to prevent the mal-operations of the OCR under normal conditions. The proposed method changes the pickup value of the OCR by adapting the power output of the DG monitored at the relaying point in the distribution network. We tested the proposed method with the actual distribution network model of the Hoenggye substation at the Korea Electric Power Co., which is composed of five feeders supplying the power to network loads and two dedicated feeders for the wind turbine generators. The simulation results demonstrate that the proposed adaptive protection method could enhance the conventional OCR of the distribution feeders with the neighboring dedicated lines for the DG.

Design Methodology of a Three-Phase Dual Active Bridge Converter for Low Voltage Direct Current Applications

  • Lee, Won-Bin;Choi, Hyun-Jun;Cho, Young-Pyo;Ryu, Myung-Hyo;Jung, Jee-Hoon
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.482-491
    • /
    • 2018
  • The practical design methodology of a three-phase dual active bridge (3ph-DAB) converter applied to low voltage direct current (LVDC) applications is proposed by using a mathematical model based on the steady-state operation. An analysis of the small-signal model (SSM) is important for the design of a proper controller to improve the stability and dynamics of the converter. The proposed lead-lag controller for the 3ph-DAB converter is designed with a simplified SSM analysis including an equivalent series resistor (ESR) for the output capacitor. The proposed controller can compensate the effects of the ESR zero of the output capacitor in the control-to-output voltage transfer function that can cause high-frequency noises. In addition, the performance of the power converter can be improved by using a controller designed by a SSM analysis without additional cost. The accuracy of the simplified SSM including the ESR zero of the output capacitor is verified by simulation software (PSIM). The design methodology of the 3ph-DAB converter and the performance of the proposed controller are verified by experimental results obtained with a 5-kW prototype 3ph-DAB converter.

Voltage Control for a Wind Power Plant Based on the Available Reactive Current of a DFIG and Its Impacts on the Point of Interconnection (이중여자 유도형 풍력발전기 기반 풍력단지의 계통 연계점 전압제어)

  • Usman, Yasir;Kim, Jinho;Muljadi, Eduard;Kang, Yong Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.23-30
    • /
    • 2016
  • Wake effects cause wind turbine generators (WTGs) within a wind power plant (WPP) to produce different levels of active power and subsequent reactive power capabilities. Further, the impedance between a WTG and the point of interconnection (POI)-which depends on the distance between them-impacts the WPP's reactive power injection capability at the POI. This paper proposes a voltage control scheme for a WPP based on the available reactive current of the doubly-fed induction generators (DFIGs) and its impacts on the POI to improve the reactive power injection capability of the WPP. In this paper, a design strategy for modifying the gain of DFIG controller is suggested and the comprehensive properties of these control gains are investigated. In the proposed scheme, the WPP controller, which operates in a voltage control mode, sends the command signal to the DFIGs based on the voltage difference at the POI. The DFIG controllers, which operate in a voltage control mode, employ a proportional controller with a limiter. The gain of the proportional controller is adjusted depending on the available reactive current of the DFIG and the series impedance between the DFIG and the POI. The performance of the proposed scheme is validated for various disturbances such as a reactive load connection and grid fault using an EMTP-RV simulator. Simulation results demonstrate that the proposed scheme promptly recovers the POI voltage by injecting more reactive power after a disturbance than the conventional scheme.

Numerical Study on Multiphase Flows Induced by Wall Adhesion (벽면부착에 의해 야기되는 다상유동에 관한 수치적 연구)

  • Myong, Hyon-Kook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.721-730
    • /
    • 2012
  • The present paper presents a numerical study on multiphase flows induced by wall adhesion. The continuum surface force (CSF) model with the wall adhesion boundary condition model is used for calculating the surface tension force; this model is implemented in an in-house solution code (PowerCFD). The present method (code) employs an unstructured cell-centered method based on a conservative pressure-based finite-volume method with a volume capturing method (CICSAM) in a volume of fluid (VOF) scheme for phase interface capturing. The effects of wall adhesion are then numerically simulated by using the present method for a shallow pool of water located at the bottom of a cylindrical tank with no external forces such as gravity. Two different cases are computed, one in which the water wets the wall and one in which the water does not wet the wall. It is found that the present method efficiently simulates the surface tension-dominant multiphase flows induced by wall adhesion.

A Study On The Change Of Tide Due to Barrage construction At The Bays Of The Western coast Of Korea (한국서해안 해만의 방조제건설에 따른 조석변화연구)

  • Yum, Ki Dai
    • 한국해양학회지
    • /
    • v.12 no.1
    • /
    • pp.33-40
    • /
    • 1977
  • British Hydraulics research Station's Sparse Scheme was suggested for the solution of two dimensional finite difference tidal equations. 2D-numerical tidal model formed with 4.8km rectangular cells was set up to find out the barrage effects on tidal ranges of some possible areas for tidal power generation in Korea. The comparisons were made hetween spring tidal ranges with and without barrages at the entrance of Asan Bay, Garorim bay, Cheonsu bay and near Incheon Bay. Because of the coarseness of the grid, the model results could not represent the values of changes precisely. However the results show that the tidal amplitude near Incheon Bay increased by about 40cm by setting a barrage and about 50cm increase near the entrance of Asan Bay, respectively. But there were only a few centimeter changes in other areas.

  • PDF

Importance-Performance Analysis of Clinical Nutrition Management in Convalescent Hospitals in the Gyeongnam Area (경남지역 요양병원 임상영양관리에 대한 중요도와 실행도 분석)

  • Lee, Seon-Jeon;Park, Eunju
    • Journal of the Korean Dietetic Association
    • /
    • v.22 no.1
    • /
    • pp.53-69
    • /
    • 2016
  • The purpose of this study was to analyze the importance-performance of clinical nutrition management in convalescent hospitals. The research was carried out based on questionnaires administered from March to April, 2015 to 73 dietitians at 40 convalescent hospitals in the Gyeongnam area. There was a statistically significant difference between the mean scores for importance (4.01/5.00) and performance (2.95/5.00) of clinical nutrition management. The importance and performance grid analysis showed that participation in a nutritional management committee, administration of patients using a cooperation program among hospital departments, cooperation with a medical team on patient's nutrition status, nutrition initial assessment, nutrition care process for patients showing malnutrition, nutrition care process for tube feeding patients, management of a therapeutic diet, meal management using dietary slip instructions including a therapeutic diet, and explication of a therapeutic diet for patients scored high regarding importance and performance (doing great area). Medical records on patient's nutrition management, and nutrition counseling for requested patient scored low regarding the importance and high regarding performance (overdone area). Participation in medical rounds, personal nutrition education for patients, group nutrition education for patients, nutrition education for medical teams, development of a menu for therapeutic diet and standardized recipes, and provision of information on diet therapy for patients after discharge scored low regarding importance and performance (low priority area). Accreditation of convalescent hospitals and interest of medical professionals in clinical nutrition management were effective variables for the importance-performance gap of clinical nutrition management. In conclusion, the accreditation process and positive awareness of medical professionals with regard to clinical nutrition management had positive effects on reduction of the importance-performance gap in clinical nutrition management at convalescent hospitals. The strength of clinical nutrition management in the accreditation and development of an education program for increasing medical team or administrator interest in clinical nutrition management could lead to improvement of clinical nutrition management for elderly patients in convalescent hospitals.