• Title/Summary/Keyword: Grid Topology

Search Result 188, Processing Time 0.029 seconds

Double-layered Peer-to-Peer Systems in MobileAd-hoc Networks (모바일애드혹 네트워크에서의 2계층 피어-투-피어 시스템)

  • Kim, Ji-Hoon;Yang, Sung-Bong
    • The KIPS Transactions:PartC
    • /
    • v.17C no.1
    • /
    • pp.61-68
    • /
    • 2010
  • As the mobile technology advances, file searching among the mobile device users becomes more important. In this paper, we propose the uniform grid, greedy, and MIS P2P systems that have double-layered topology to search files efficiently for mobile ad-hoc networks. In these systems, peers are classified into two groups, super-peers and sub-peers, and each super-peer manages its neighboring sub-peers. In the proposed systems, each super-peer maintains the appropriate information of its sub-peers so that when a peer requests a file, the request is sent to its super-peers and then to neighboring super-peers. Hence the proposed systems could avoid multi-broadcasting and reduce network overheads. The experimental results show that the proposed systems outperform a single-layered P2P system in terms of the average number of messages to find target files. Especially the MISsystem improves by reducing the average number of messages by 48.9% while maintaining the same search accuracy.

Time Synchronization for WSN Nodes Operating on Low-Energy Sleep-Wake Cycles (저 에너지의 취침 기상 사이클로 작동하는 무선센서 네크워크 노드들을 위한 시간 동기화)

  • Yun, Ho-Jung;Yun, Joo-Sung;Lee, Sung-Gu
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.3
    • /
    • pp.331-335
    • /
    • 2010
  • Previous low-energy time synchronization methods have mainly focused on reducing the number of transmission or reception packets. However, this paper proposes a method that reduces the percentage of time a node has to be awake (the duty cycle), assuming that a periodic sleep-wake cycle is used to conserve energy. Based on our experience with actual WSN devices, a system model is proposed, and the potential performance of the proposed method, with different parameter values, is analyzed. To further demonstrate the feasibility of our method, experiments were conducted using nine WSN devices in a $3{\times}3$ grid network topology. The results show the average synchronization error is 107.57 $\mu{s}$ in duty cycle 5% and synchronization period 10 sec, and 130 $\mu{s}$ in duty cycle 2.5% and synchronization period 20 sec.

Drsign and Evaluation of a GQS-based Fog Pub/Sub System for Delay-Sensitive IoT Applications (지연 민감형 IoT 응용을 위한 GQS 기반 포그 Pub/Sub 시스템의 설계 및 평가)

  • Bae, Ihn-Han
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.8
    • /
    • pp.1369-1378
    • /
    • 2017
  • Pub/Sub (Publish/Subscribe) paradigm is a simple and easy to use model for interconnecting applications in a distributed environment. In general, subscribers register their interests in a topic or a pattern of events and then asynchronously receive events matching their interest, regardless of the events' publisher. In order to build a low latency lightweight pub/sub system for Internet of Things (IoT) services, we propose a GQSFPS (Group Quorum System-based Fog Pub/Sub) system that is a core component in the event-driven service oriented architecture framework for IoT services. The GQSFPS organizes multiple installed pub/sub brokers in the fog servers into a group quorum based P2P (peer-to-peer) topology for the efficient searching and the low latency accessing of events. Therefore, the events of IoT are cached on the basis of group quorum, and the delay-sensitive IoT applications of edge devices can effectively access the cached events from group quorum fog servers in low latency. The performance of the proposed GQSFPS is evaluated through an analytical model, and is compared to the GQPS (grid quorum-based pud/sub system).

A Design and Control of Bi-directional Non-isolated DC-DC Converter with Coupled Inductors for Rapid Electric Vehicle Charging System

  • Kang, Taewon;Kim, Changwoo;Suh, Yongsug;Park, Hyeoncheol;Kang, Byungil;Kim, Daegyun
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.429-430
    • /
    • 2011
  • This paper presents a simple and cost-effective stand-alone rapid battery charging system of 30kW for electric vehicles. The proposed system mainly consists of active front-end rectifier of neutral point clamped 3-level type and non-isolated bi-directional dc-dc converter of multi-phase interleaved half-bridge topology with coupled inductors. The charging system is designed to operate for both lithium-polymer and lithium-ion batteries. The complete charging sequence is made up of three sub-interval operating modes; pre-charging mode, constant-current mode, and constant-voltage mode. The pre-charging mode employs the staircase shaped current profile to accomplish shorter charging time while maintaining the reliable operation of the battery. The proposed system is able to reach the full-charge state within less than 16min for the battery capacity of 8kWh by supplying the charging current of 67A. The optimal discharging algorithm for Vehicle to the Grid (V2G) operation has been adopted to maintain the discharging current of 1C. Owing to the simple and compact power conversion scheme, the proposed solution has superior module-friendly mechanical structure which is absolutely required to realize flexible power expansion capability in a very high-current rapid charging system.

  • PDF

3-D Nano Topology Measurement using VCM (VCM(voice coil motor)를 이용한 3차원 나노 형상 측정 시스템)

  • Jung, Jong-Kyu;Youm, Woo-Sub;Park, Kiy-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1439-1443
    • /
    • 2007
  • In this paper, vibration reduction techniques of a voice coil motor (VCM) actuator are presented for AFM imaging system. The damping coefficient of the actuator driven by VCM with a flexure hinge is quite low and it cause the about 30dB peak amplitude response at the resonance frequency. To decrease this peak response, we design and apply elliptical band-stop filters to xy and z axis VCM actuator. Frequency response of each actuator with filter is measured to verify the effect of the filters. As a sensor, capacitive sensor is used. Vibration reduction rate of the xy actuator with the filter is also measured while real AFM scanning condition. As another method, closed loop control with the capacitive sensor is applied to the xy axis actuator to add an electrical damping effect and vibration reduction rate measured. These vibration reduction rates with each method are compared. In the case of z axis actuator, the frequency response of force (gap) control loop is measured. For comparison, the frequency response using a conventional PID controller is also obtained. Finally, the AFM image of a standard grid sample is measured with the designed controller to analyze the effect in the AFM imaging.

  • PDF

A Novel Topology Structure and Control Method of High-Voltage Converter for High-Input-Voltage Applications

  • Song, Chun-Wei;Zhao, Rong-Xiang;Zhang, Hao
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.79-84
    • /
    • 2012
  • In this paper, a three-phase high-voltage converter (HVC), in which the main structure of each phase is composed of a cascaded PWM rectifier (CPR) and cascaded inverter (CI), is studied. A high-voltage grid is the input of the HVC. In order to ensure proper operation of the HVC, the control method should achieve output voltage sharing (OVS) among the rectifiers in the CPR, OVS among the inverters in the CI, and high power factor. Master-slave direct-current control (MDCC) is used to control the CPR. The ability of the control system to prevent interference is strong when using MDCC. The CI is controlled by three-loop control, which is composed of an outer common-output-voltage loop, inner current loops and voltage sharing loops. Simulation results show low total harmonic distortion (THD) in the HVC input currents and good OVS in both the CPR and CI.

A High Efficiency Two-stage Inverter for Photovoltaic Grid-connected Generation Systems

  • Liu, Jiang;Cheng, Shanmei;Shen, Anwen
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.200-211
    • /
    • 2017
  • Conventional boost-full-bridge and boost-hybrid-bridge two-stage inverters are widely applied in order to adapt to the wide dc input voltage range of photovoltaic arrays. However, the efficiency of the conventional topology is not fully optimized because additional switching losses are generated in the voltage conversion so that the input voltage rises and then falls. Moreover, the electrolytic capacitors in a dc-link lead to a larger volume combined with increases in both weight and cost. This paper proposes a higher efficiency inverter with time-sharing synchronous modulation. The energy transmission paths, wheeling branches and switching losses for the high-frequency switches are optimized so that the overall efficiency is greatly improved. In this paper, a contrastive analysis of the component losses for the conventional and proposed inverter topologies is carried out in MATLAB. Finally, the high-efficiency under different switching frequencies and different input voltages is verified by a 3 kW prototype.

NUMERICAL SIMULATIONS OF LOW- AND HIGH-FREQUENCY BUZZ AROUND AN AXISYMMETRIC SUPERSONIC INLET (축대칭 초음속 흡입구 주위의 저주파수 및 고주파수 버즈(Buzz)에 대한 수치모사)

  • Kwak, E.;Lee, N.;Gong, H.;Lee, S.
    • Journal of computational fluids engineering
    • /
    • v.18 no.2
    • /
    • pp.78-84
    • /
    • 2013
  • In this paper, numerical simulations of both low- and high-frequency buzz phenomena at the throttle ratios (T.R.) in Nagashima's experiment are performed. The dominant frequencies of the low-and high-frequency buzz in the experiment are about 109 Hz with T.R.=0.97 and 376 Hz with T.R.=0.55, respectively. An axisymmetric solver with the S-A turbulence model is used for the simulations, and DFT(Discrete Fourier Transform) on pressure histories is conducted for the buzz frequency analysis. In the present simulations, the free-stream Mach number and the Reynolds number based on the inlet diameter are 2 and $10^7$, respectively. Both the low- and high-frequency buzz phenomena are accomplished without the changes in the grid topology. The dominant frequency of the simulation is about 125 Hz with T.R.=0.97, while it is 399 Hz with T.R.=0.55.

The Study of 3-Phase Bi-Directional DC to AC Inverter for the Bi-Model PV PCS (자립형 태양광 발전 시스템을 위한 3상 양방향 DC-AC 인버터 연구)

  • Yang, Seung-Dae;Jung, Seung-Hwan;Choi, Ju-Yeop;Choy, Ick;Lee, Young-Kwon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.319-324
    • /
    • 2012
  • This paper presents the study of 3-Phase bi-directional DC to AC inverter with unity power factor. 3-Phase bi-directional DC to AC inverter is important for the bi-modal PV PCS with an energy storage system. Both Inverting and converting are needed to connect between the grid side and boost converting side to charge and discharge the energy storage system. The paper proposes the appropriate circuit topology and proper control system for the bi-directional inverter. It also proposes the method of selecting the optimum control method considering system stability. PSIM simulation is used to validate the proposed algorithm.

  • PDF

EFFECTS OF THE FREE SURFACE ON THE FLOW PATTERN PAST A SQUARE CYLINDER (정방형 실린더 주위 유동패턴에 대한 자유수면의 영향)

  • Ahn, Hyungsu;Yang, Kyung-Soo
    • Journal of computational fluids engineering
    • /
    • v.22 no.1
    • /
    • pp.81-87
    • /
    • 2017
  • The characteristics of flow past a square cylinder submerged under the free surface have been numerically studied. An immersed boundary method was adopted for implementation of the cylinder cross-section in a Cartesian grid system. Also, a level-set method was used to capture the interface of the two fluids. The case for Reynolds number 150 was examined. At the specific Reynolds number, by varying the gap ratio(0.25, 0.40, 0.55, 0.70, 1.00, 1.50, 2.50, 5.00) the effects of the free surface on the force coefficients and Strouhal number of vortex shedding were identified. The presence of the free surface very close to the cylinder significantly affects the shedding pattern, resulting in considerable deviation of the force coefficients and Strouhal number from those of the single-phase flow. In addition, the influence of Froude number was considered in this study. By increasing Froude number(0.2-0.4), flow topology change was identified at the specific gap ratios(0.40, 0.70, 1.50, 5.00).