• Title/Summary/Keyword: Grid Connected System

검색결과 846건 처리시간 0.022초

전력 디커플링 기능을 가진 단상 계통연계 전압형 인버터 (Single Phase Grid Connected Voltage-ed Inverter Utilizing a Power Decoupling Function)

  • 이상욱;문상필;박한석
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.236-241
    • /
    • 2017
  • This paper presents a single-phase grid connected voltage-ed inverter with a power decoupling circuit. In the single-phase grid connected voltage-ed inverter, it is well known that a power pulsation with twice the grid frequency is contained in the input power. In a conventional voltage type inverter, electrolytic capacitors with large capacitance have been used in order to smooth the DC voltage. However, lifetime of those capacitors is shortened by the power pulsation with twice grid frequency. The authors have been studied a active power decoupling(APD) method that reduce the pulsating power on the input DC bus line, this enables to transfer the ripple energy appeared on the input DC capacitors into the energy in a small film capacitor on the additional circuit. Hence, extension of the lifetime of the inverter can be expected because the small film capacitor substitutes for the large electrolytic capacitors. Finally, simulation and experimental results are discussed.

비선형부하에 의해 발생하는 고조파 보상을 위한 독립형 또는 계통연계형 인버터 제어기 설계 (Controller Design of Stand-Alone or Grid-Connected Inverter to Compensate Harmonics Caused by Nonlinear Load)

  • 신찬호;임경배;;최재호
    • 전력전자학회논문지
    • /
    • 제22권5호
    • /
    • pp.440-448
    • /
    • 2017
  • This paper proposes a controller design of a distributed source inverter in stand-alone mode or grid-connected mode to compensate the current or voltage harmonics caused by local nonlinear load. The PR-based multi loop controller has been used to improve the dynamic performance of the system and to compensate the output voltage or grid current harmonics. The multi-loop controller consists of an outer current controller and an inner voltage controller for the output voltage control in stand-alone mode. In grid-connected mode, an outer current controller is added to the output voltage controller for the grid current control. The design performance of each controller is described through the Root locus and Bode plot of the transfer functions. The validity of the proposed control algorithm and design parameters has been verified through the PSiM simulation and experimental results.

2MVA급 배터리 에너지 저장시스템 개발 (A Development of 2MVA Battery Energy Storage System)

  • 김수홍;김태형;김윤현;인동석;권병기;최창호
    • 전력전자학회논문지
    • /
    • 제17권2호
    • /
    • pp.174-181
    • /
    • 2012
  • Energy storage system connected to the grid has two functions such as the surplus power of a grid is stored in batteries or the energy stored in batteries will supply to the grid when the grid needs. The battery energy storage system consist of power condition system (PCS) for power supply and battery conditioning system (BCS). Lithium-ion batteries are mainly used. In this paper, the battery energy storage system connected to the grid described. The configuration of the 2MVA class power control system using water cooling and battery system are presented. And control method for the system and the output filter design method are proposed. Experimental verification of the proposed system is provided with 2MVA PCS and 500kWh BCS.

LCL Filter Design Method for Grid-Connected PWM-VSC

  • Majic, Goran;Despalatovic, Marin;Terzic, Bozo
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1945-1954
    • /
    • 2017
  • In recent years, several LCL filter design methods for different converter topologies have been published, many of which use analytical expressions to calculate the ideal converter AC voltage harmonic spectrum. This paper presents the LCL filter design methodology but the focus is on presentation and validation of the non-iterative filter design method for a grid-connected three-phase two-level PWM-VSC. The developed method can be adapted for different converter topologies and PWM algorithms. Furthermore, as a starting point for the design procedure, only the range of PWM carrier frequencies is required instead of an exact value. System nonlinearities, usually omitted from analysis have a significant influence on VSC AC voltage harmonic spectrum. In order to achieve better accuracy of the proposed procedure, the system nonlinear model is incorporated into the method. Optimal filter parameters are determined using the novel cost function based on higher frequency losses of the filter. An example of LCL filter design for a 40 kVA grid-connected PWM-VSC has been presented. Obtained results have been used to construct the corresponding laboratory setup and measurements have been performed to verify the proposed method.

단상 계통연계형 태양광 발전 시스템의 직류링크 맥동전압 보상 (DC link Ripple Voltage Compensation of a Single-phase Grid-Connected PV System)

  • 이재근;최종우
    • 전력전자학회논문지
    • /
    • 제17권5호
    • /
    • pp.377-387
    • /
    • 2012
  • A single-phase grid-connected PV system is known as suitable for housing of less than 3 kW. The DC link voltage in a single-phase PV system has necessarily twice component of fundamental wave. It makes high THD in the grid current. According to the problem, power quality is lower. Many engineers have studied about this problem. The most simple method is to use low pass filter on DC link voltage control. However it is affected by DC link voltage control bandwidth. If cutoff frequency is reduced to increase the performance of low pass filter, it also lowers DC link voltage control bandwidth. Second method is using band stop filter, it works good on steady state but not good on transient state. This paper proposes the new method for removing ripple voltage to get an exact current reference. It improves the responses on steady state and transient state. The performance was verified through computer simulation using MATLAB and actual experiments.

병렬 연결된 계통연계형 연료전지 전력변환장치의 단독운전방지 평가 연구 (A Study on Anti-Islanding Evaluation of Grid-Connected Power Conditioning System for Fuel Cell System in Parallel Operation)

  • 최영주;오건우;김민우;이승국;박가우
    • 한국가스학회지
    • /
    • 제22권5호
    • /
    • pp.124-132
    • /
    • 2018
  • 파리협정의 체결로 신 재생에너지 보급이 활발해지고 있다. 국내의 경우 공공건물 중심으로 신 재재생에너지 보급 정책이 진행되고 있으며, 건물 내에 설치가 비교적 수월한 연료전지 시스템의 보급이 확대될 전망이여서 계통연계형 연료전지 전력변환장치의 단독운전방지 평가 연구가 중요하다. 본 연구에서는 연료전지 전력변환장치의 국내 인증기준 KGS AB934 PC53이 해외 규격과 부합하는지 검토해보고 계통연계 시 중요한 안전성능인 단독운전방지 평가에 대해 분석하였다. 또한, 병렬로 연결된 두 대의 전력변환장치의 단독운전방지 평가를 위한 시작품을 제작하고 실증 평가를 통해 여러 대의 연료전지 시스템이 설치되고 있는 상황에 맞는 안전성능 확보 방안을 연구하였다.

전력계통 고장시 계통연계형 태양광발전시스템의 영향분석 (Analysis of the Effect of the Grid-connected Photovoltaic System in Fault Case of Power System)

  • 박성훈;이용식;정성원;김재현
    • 한국태양에너지학회 논문집
    • /
    • 제39권4호
    • /
    • pp.69-77
    • /
    • 2019
  • Among the main functions of the grid-connected photovoltaic (PV) system, the anti-islanding operation function is a very important problem. Recently, due to the improvement in power generation efficiency and the maintenance advantages in PV system, the use of string inverter has increased so that the possibility of islanding operation has been raised. Generally, when a power system faults, the PV inverter must be disconnected from power system within 10 cycles by the anti-islanding operation function. However, in the real-time of power system, the output power of the PV system within 10cycles is effected. In this paper, we analyzed the effect of grid-connected PV system on power quality in a short time within 10 cycles on fault case of power system using the Matlab Simulink program.

계통 연계형 태양광 발전 시스템의 위상 동기화를 위한 디지털 PLL 제어 (Digital PLL Control for Phase-Synchronization of Grid-Connected PV System)

  • 김용균;최종우;김흥근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권9호
    • /
    • pp.562-568
    • /
    • 2004
  • The frequency and phase angle of the utility voltage are important in many industrial systems. In the three-phase system, they can be easily known by using the utility voltage vector. However, in the case of single phase system, there are some difficulties in detecting the information of utility voltage. In conventional system, the zero-crossing detection method is widely used, but could not obtain the information of utility voltage instantaneously. In this paper, the new digital PLL control using virtual two phase detector is proposed with a detailed analysis of single-phase digital PLL control for utility connected systems. The experimental results under various utility conditions are presented and demonstrate an excellent phase tracking capability in the single-phase grid-connected operation.

Improved DC Offset Error Compensation Algorithm in Phase Locked Loop System

  • Park, Chang-Seok;Jung, Tae-Uk
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1707-1713
    • /
    • 2016
  • This paper proposes a dc error compensation algorithm using dq-synchronous coordinate transform digital phase-locked-loop in single-phase grid-connected converters. The dc errors are caused by analog to digital conversion and grid voltage during measurement. If the dc offset error is included in the phase-locked-loop system, it can cause distortion in the grid angle estimation with phase-locked-loop. Accordingly, recent study has dealt with the integral technique using the synchronous reference frame phase-locked-loop method. However, dynamic response is slow because it requires to monitor one period of grid voltage. In this paper, the dc offset error compensation algorithm of the improved response characteristic is proposed by using the synchronous reference frame phase-locked-loop. The simulation and the experimental results are presented to demonstrate the effectiveness of the proposed dc offset error compensation algorithm.

태양광 시스템의 전 범위 전력점 추종을 위한 CPG 알고리즘에 관한 연구 (A Study on Constant Power Generation Algorithms for a Whole Range Power Point Tracking in Photovoltaic Systems)

  • 양형규;방태호;배선호;박정욱
    • 전력전자학회논문지
    • /
    • 제24권2호
    • /
    • pp.111-119
    • /
    • 2019
  • In this study, constant power generation (CPG) algorithms are introduced for whole range power point tracking in photovoltaic systems. Currently, maximum power point tracking (MPPT) algorithm is widely used for high-power photovoltaic systems. However, MPPT algorithm cannot flexibly control such systems according to changing grid conditions. Maintaining grid stability has become important as the capacity of grid-connected photovoltaic systems is increased. CPG algorithms are required to generate the desired power depending on grid conditions. A grid-connected photovoltaic system is configured, and CPG algorithms are implemented. The performances of the implemented algorithms are compared and analyzed by experimental results.