• Title/Summary/Keyword: Green Performance

검색결과 1,554건 처리시간 0.03초

그린팀버월 패널의 열전달 특성 (Heat transfer of green timber wall panels)

  • 김윤희;장상식;신일중
    • 농업과학연구
    • /
    • 제38권1호
    • /
    • pp.115-120
    • /
    • 2011
  • 20% of total energy use to sustain temperature of building inside. In this reasons, researchers effort to improve the thermal insulation capacity with new wall system. Using appropriate materials and consisting new wall system should considered in energy saving design. OSB(Oriented strand board), Larch lining board used to consist wall system. $2{\sim}6$ Larch lining board has tongue & groove shape for preventing moisture. Comparing with gypsum board and green timber lining board as interior sheathing material, temperature difference of Green timber wall system was bigger than temperature difference of gypsum board wall system. This aspects indicate that Green timber wall system was revealed higher thermal insulation property than gypsum board wall system. Gypsum board portion transfer heat easily because temperature difference gradient of gypsum board wall system was smaller than OSB wall system. Total temperature variation shape of G-4-S and G-6-S show similar model but, temperature variation shape in green timber wall portion assume a new aspect. The purpose of this study was that possibility of thermal insulation variation and new composition of wall system identify to improve thermal insulation performance. In the temperature case, this study shows possibility of improving thermal insulation performance. Humidity, sunshine and wind etc. should considered to determine building adiabatic properties.

사례분석을 통한 친환경 건축물 인증제도 개선방향 연구 (A Study of Case Analysis on Green Building Certification Criteria for Advanced Methods)

  • 모지선;김철;임태섭;강윤도;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.178-183
    • /
    • 2008
  • Recently, sick house syndrome caused by pollutants and contamination of buildings crops out in residential environment of buildings. According to price increase of global oil, comfort of occupants in indoor air quality is required with reduction of energy consumption and environmental load. So, building performance certification criteria come into effect for improvement of building energy efficiency and performance in environment at home and abroad. GBCC(Green Building Certification Criteria) of domestic country as a Criteria is managed Korea Green Building Council(KGBC) for green building. Thus, purpose of this study is to design a direction of Green Building Certification Criteria for improvement through analysis of GBCC application elements and selected building.

  • PDF

인공지반녹화용 멤브레인 방수 및 방근재료의 방근성능 평가 방법 제안 연구 (A Standard Test Methods of Resistance to Root Penetration for Waterproofing and Rootproofing Membrane Using Green Roof System)

  • 이정훈;선윤숙;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.141-148
    • /
    • 2009
  • The purpose of this paper is to propose a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. Green roof system is considered to be an important subject in construction industry for green growth project. At the same time, we have to consider the counterplan for protection the damage of waterproofing layer and concrete substrate from the penetration of plant root. But many kinds of materials for protection from root penetration are using in construction field. But the performance of those materials is not clear, and there is not test methods for the evaluation of performance. So in this paper, based on the research results of 4 institutes during four years and foreign cases, we made a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. This test method deals with about environmental condition of laboratory, experimental facilities, kinds of plant, specimen of test, management methods, evaluation duration and documents, etc.

  • PDF

스마트 그린인프라 기술을 활용한 도로변 미세먼지 저감장치의 성능 및 유지·관리 비용 평가 (Evaluation of Performance and Maintenance Cost for Roadside's Particulate Matter Reduction Devices Using Smart Green Infrastructure Technology)

  • 송규성;석영선;임효숙;전진형
    • 한국환경복원기술학회지
    • /
    • 제25권4호
    • /
    • pp.15-31
    • /
    • 2022
  • The Green Purification Unit System (GPUS) is a green infrastructure facility applicable to the roadside to reduce particulate matter from road traffic. This study introduces two types of GPUS (type1 and type2) and assesses the performance and maintenance costs of each of them. The GPUS's performance analysis used the data collected in November 2021 after the installation of the GPUS type1 and type2 at the study site in Suwon. The changes in the particulate matter concentration near the GPUS were measured. The maintenance cost of GPUS type1 and type2 was assessed by calculating the initial installation cost and the management and repair cost after installation. The results of the performance analysis showed that the GPUS type1, which was manufactured by combining plants and electric dust collectors, had a superior particulate matter reduction performance. In particular, type1 produced a greater effect of particulate matter reduction in the time with a high concentration (50㎍/m3 or higher) of particulate matter due to the operation of electric dust collectors. GPUS type2, which was designed in the form of a plant wall without applying an electric dust collector, showed lower reduction performance than type1 but showed sufficiently improved performance compared to the existing band green area. Meanwhile, the GPUS type1 had three times higher costs for the initial installation than GPUS type2. In terms of costs for managing and repairing, it was evaluated that type1 would be slightly more costly than type2. Finally, this study discussed the applicability of two types of GPUS based on the result of the analysis of their particulate matter performance and maintenance cost at the same time. Since GPUS type2 has a cheaper cost than type1, it could be more economical. However, in the area suffering a high concentration of particulate matter, GPUS type1 would be more effective than type2. Therefore, the choice of GPUS types should rely on the status of particulate matter concentration in the area where GPUS is being installed.

Carbon Molecular Sieve Membranes Dispersed with Nano Particles

  • H.Suda;Ha, K.raya
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2004년도 Proceedings of the second conference of aseanian membrane society
    • /
    • pp.183-186
    • /
    • 2004
  • Nano particles-containing CMS membranes were prepared by pyrolysis of polyimides dispersed uniformly with precursors and their gas separation performances were examined, to elucidate the permeation mechanism and to further improve the gas separation performance. Consequently, it was suggested that the separation performance could be controlled by doping nano-particles in the CMS membranes, and that optimization of various factors, such as the size, content, and dispersion state of the nano particles would contribute for further improvement of the gas separation performance.

  • PDF

국내 친환경 건축물 인증 제도의 유지관리 부문 개선 방안 (A study on the Improvement of the Korea Green Building Certification Criteria by Assessing the Maintenance Categories)

  • 김창성;김경아
    • KIEAE Journal
    • /
    • 제11권5호
    • /
    • pp.129-135
    • /
    • 2011
  • Many countries have carried out various policies about sustainable building to protect the earth against the global warming and environmental pollution. Korea government has also executed the Green Building Certification System. In order to keep the performances of certificated buildings sustainable, the effective building maintenance is quite necessary. Meanwhile, the foreign green building certification systems have considered the building maintenance as one of the most important items to keep the building performance effective. However, Green Building Certification Criteria(GBCC) of Korea has not had the sufficient criteria for the maintenance of green building. Therefore, The purpose of this study is to find direction for the improvement of management categories of Korea Green Building Certification Criteria. For this aim, GBCC was compared with the foreign certification systems such as LEED, BREEAM and CASBEE.

공기업 녹색성장 정책의 개선방안에 대한 연구 (An Improvement Strategy for the Green Growth Policies of Korean Public Corporations)

  • 신완선;곽채기;박연탁
    • 산업경영시스템학회지
    • /
    • 제36권3호
    • /
    • pp.25-33
    • /
    • 2013
  • This study investigates the current status of the green growth policies of Korean public corporations and proposes some potential improvement ideas. A set of twenty global green trends are first elicited by using classified macro trends of environmental changes. The green trends are categorized into four key issues based on which domestic and international research efforts are compared. The management performance reports of Korean public corporations are then throughly analyzed to evaluate the validity of their strategic green tasks in relevant to the global green trends. Finally, we suggest some potential government policies for enhancing the existing green growth businesses of public corporations.

Building Integrated Vegetation Systems into the New Sainsbury's Building Based on BIM

  • Lee, Dong-Kyu
    • 한국BIM학회 논문집
    • /
    • 제4권2호
    • /
    • pp.25-32
    • /
    • 2014
  • Today, there is a growing need of environment-friendly buildings, so-called 'green', facilities, and energy saving buildings to decrease environmental pollutants released into cities by construction activities. Green-Building Information Modeling (Green-BIM) is a purpose-built solution which supports to forecast energy consumption of 3-D model of a building by augmenting its primary 3-D measurements (width, height and depth) with many more dimensions (e.g. time, costs, social impacts and environmental consequences) throughout a series of sequential phases in the lifecycle of a building. The current study was carried out in order to integrate vegetation systems (particularly green roof and green wall systems) and investigate thermal performance of the new Sainsbury's building which will be built on Melton road, Leicester, United Kingdom. Within this scope, a 3-D building model of the news Sainsbury's building was first developed in $Autodesk^{(R)}$ $Revit^{(R)}$ and this model was then simulated in $Autodesk^{(R)}$ $Ecotect^{(R)}$once weather data of the construction site was obtained from $Autodesk^{(R)}$ Green Building $Studio^{(R)}$. This study primarily analyzed data from (1) solar radiation, (2) heat gains and losses, and (3) heating and cooling loads simulation to evaluate thermal performance of the building integrated with vegetation system or conventionally available envelops. The results showed that building integrated vegetation system can potentially reduce internal solar gains on the building rooftops by creating a 'bioshade'. Heat gains and losses through roofs and walls were markedly diminished by offering greater insulation on the building. Annual energy loads for heating and cooling were significantly reduced by vegetation more significantly through the green roof system in comparison to green wall system.

Construction of Strontium Titanate/Binary Metal Sulfide Heterojunction Photocatalysts for Enhanced Visible-Light-Driven Photocatalytic Activity

  • Yu, Yongwei;Yang, Qing;Ma, Jiangquan;Sun, Wenliang;Yin, Chong;Li, Xiazhang;Guo, Jun;Jiang, Qingyan;Lu, Zhiyuan
    • Nano
    • /
    • 제13권11호
    • /
    • pp.1850130.1-1850130.12
    • /
    • 2018
  • A novel strontium titanate/binary metal sulfide ($SrTiO_3/SnCoS_4$) heterostructure was synthesized by a simple two-step hydrothermal method. The visible-light-driven photocatalytic performance of $SrTiO_3/SnCoS_4$ composites was evaluated in the degradation of methyl orange (MO) under visible light irradiation. The photocatalytic performance of $SrTiO_3/SnCoS_4-5%$ is much higher than that of pure $SrTiO_3$, $SnCoS_4$, $SrTiO_3/SnS_2$ and $SrTiO_3/CoS_2$. The $SrTiO_3/SnCoS_4$ composite material with 5 wt.% of $SnCoS_4$ showed the highest photocatalytic efficiency for MO degradation, and the degradation rate could reach 95% after 140 min irradiation time. The enhanced photocatalytic activity was ascribed to not only the improvement of visible light absorption efficiency, but also the construction of a heterostructure which make it possible to effectively separate photoexcited electrons and holes in the two-phase interface.

녹색경영 평가지표를 적용한 국내·외 정유/화학기업의 녹색경영 비교 연구 (A Study on Green Management of Petroleum Refining and Chemical Companies Applying to Assessment Indicator of Green Management)

  • 백장현
    • 한국기후변화학회지
    • /
    • 제3권2호
    • /
    • pp.101-116
    • /
    • 2012
  • 녹색경영은 기후변화 대응이 전 세계적 이슈로 부각되면서 기존의 환경경영에 온실가스 저감, 대체에너지 개발 등 저탄소 녹색성장 요소가 추가된 확장된 개념으로 국내 외적으로 기업의 녹색경영 성과 측정에 대한 논의가 확산되고, 기업의 환경관리 수준 파악, 분석 및 평가의 중요성이 대두되면서 다양한 형태의 녹색경영 성과측정지표 체계가 개발되어 운영되고 있다. 하지만, 녹색경영에 관련한 구체적인 실행 방법론 제시는 미흡한 실정이다. 이에 본 연구에서는, 제시된 평가지표에 따라 기업간 녹색경영 수준 비교가 객관적으로 평가되게 하기 위해 가중치 산정을 위한 전문가 설문조사를 실시하였고, AHP(Analytic Hierarchy Process) 분석을 적용하였다. 국내외 10개 주요 정유/화학기업을 평가대상으로 선정하여 지속가능성 보고서 및 관련 문헌자료 등을 분석하였으며, 가중치가 부여된 세부 지표항목에 의거한 평가지표별 기업의 평가점수 도출 및 기업간 점수차이 분석을 실시 하였다.