• 제목/요약/키워드: Green Facade

검색결과 29건 처리시간 0.03초

관수조절에 의한 벽면녹화의 냉각효과 분석 연구- 아이비, 수호초를 식재한 모듈형 벽면녹화를 중심으로- (A field Study to Evaluate Cooling Effects of Green Facade under Different Irrigation Conditions - Focusing on modular green facade planted with Hedera helix L and Pachysandra terminalis -)

  • 김은섭;윤석환;박정강;전윤호;강혜원;김상혁;김지연;이용구;이동근
    • 한국환경복원기술학회지
    • /
    • 제24권6호
    • /
    • pp.121-132
    • /
    • 2021
  • Green facade has a significant impact on building's energy performance by controlling the absorption of solar radiation and improving outdoor thermal comfort through shading and evapotranspiration. In particular, since high-density building does not enough green space, green facade, and rooftop greening using artificial ground plants are highly utilized. However, the level of cooling effect according to plant traits and irrigation control is different. Therefore, in this study, the cooling effect analyzed for a total of 4 cases by controlling the irrigation condition based on hedera and spurge. Although hedera under sufficient water had the highest cooling effect(-2℃~-4℃), had the lowest cooling effect under non-irrigation(+1.1℃~+4.4℃). In addition, hedera under sufficient water had cooling effect than hedera under non-irrigation(-1℃~-8.1℃) and in the case of spurge, it had cooling effect(-0.3℃~-7.8℃) more than non-irrigation. As a result of measuring the amount of transpiration according to the light intensity (PAR) and carbon dioxide concentration conditions, transpiration of hedera was higher than the spurge (respectively 0.63204mmolm-2s-1, 0.674367mmolm-2s-1). The difference in the cooling effect of the green facade under irrigation condition was significant. But the potential cooling effect of green facade according to plants species was different. Therefore, in order to maximize and continuously provide the cooling effect of green facade in urban areas, it is necessary to consider the characteristics of plants and the control of water supply through the irrigation system.

벽면녹화의 패턴 표현방법에 따른 반복패턴 디자인 특성 분석 (An Analysis of the Repetition Pattern in Green facade focusing on the Biophilic Design)

  • 정희영;이현수
    • 한국실내디자인학회논문집
    • /
    • 제25권1호
    • /
    • pp.81-92
    • /
    • 2016
  • Within green facades, the greening side of the wall is first recognized by people, leaving a visually lasting impression. As facades play a crucial factor in forming street image, their design can be considered most important. In modern days, 'patterns,' one of the popular elements of design, has developed into becoming a method of expressing architects' emotions or images as well as ways of seeking satisfaction. As opposed to recent overseas movement where patterned green facades have been widely utilized, the domestic trend still remains in outdoor green facades without patterns. This study, focusing on overseas patterned green facades, classifies the facade pattern's expressive methods into two greater parts, and four categories. Furthermore, among the elements and properties from Biophilic pattern guidelines, we specifically focus on 'Repetition Pattern,' which corresponds to 'Complexity & Order.' Biophilic design has the notion of pursuing an environment that aids modern people's comfort and well being. Providing information on patterned green facades that have largely gained popularity, this study also presents its aesthetic directions that may be applicable domestically in the future.

일사조절 장치 적용에 따른 에너지 및 비용효과 분석 (Energy and Cost Efficiency on applying Solar Control Facade System)

  • 안기언;김승진;김동희;문현석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.98-99
    • /
    • 2013
  • Recently, solar control facade systems are highlighted due to its low cost and outstanding applicability for green remodeling. However, it has not been long time since the systems were introduced. Therefore, the application study of the solar control system also has been insufficient. In this study, simulated models were developed and three types of solar control systems(i.e., overhang, blind, and screen)are installed in the models. The efficiency of energy savings and investment payback period according to the application of solar control facade system were analyzed.

  • PDF

이중외피시스템의 차음성능 평가에 관한 연구 -전면형 이중외피시스템을 중심으로- (A Study on the Evaluation of Sound Insulation Performance of Double Skin Facade -Focus on the Multi-story type of Double Skin Facade-)

  • 석호태;차민철
    • 한국주거학회논문집
    • /
    • 제15권2호
    • /
    • pp.11-18
    • /
    • 2004
  • The purpose of this study is to evaluate the sound insulation performance and present fundamental data for sound insulation plan about open and close windows of inner facade and outer facade of Double-skin Facade system applied to multi-story type. The Headquarter of Green Building and the Energy Saving Building in the Korea Institute of Energy Research was selected for experiment. Measurement method which are specified in the Korea Standard 2235 were selected for this study. As the result of this study, 1) Sound insulation performance of Multi-layer type of Double-skin Facades is very excellent about outdoor noise. 2) Vertical level is higher, it shows that more decreases sound pressure level.

패널형 입면녹화의 시각적 만족도에 관한 연구 (A Study on the Visual Satisfaction of a Panel-type Facade Planting)

  • 한승호;김선혜;송규성
    • 한국조경학회지
    • /
    • 제36권2호
    • /
    • pp.53-59
    • /
    • 2008
  • 도시가 산업화 되어가면서 도심의 토지이용이 과밀화되고 건축물의 면적이 늘어나고 있다. 이에 건축물 녹화가 옥상 및 벽면을 중심으로 적극적으로 조성되고 있으며, 입면녹화의 경우 건물이 고층화 되면서 입면적이 넓어 벽면녹화가 도심에서 효과적인 녹화수단으로 인식되고 있다. 특히 패널타입의 녹화수법은 조기 녹화와 설치 시공의 편리함으로 점차 이용이 증가하고 있다. 그러나 패널타입에 대 한 연구는 대부분 식생 하부 시스템이나 관수시스템을 중심으로 이루어지고 있으며, 경관 중심에 대한 연구는 전무한 실정이다. 이에 본 연구에서는 패널형 입면녹화의 경관평가를 통하여 선호요소를 추출하고자 한다. 설문은 패널형 입면녹화가 설치된 장소의 이용자들을 중심으로 직접조사를 하였다 연구 결과, 자연스럽다는 형용사에서 3.80으로 가장 높은 점수를 나타났다. 이는 옹벽이나 건축물 벽면이 드러나는 것보다 녹화를 하는 것이 이용자들에게 긍정적인 반응을 보이는 것으로 사료된다. 다음으로 친근한(3.70), 편안한(3.65), 아름다운(3.65), 안정감 있는(3.50)가 긍정적인 경관이미지로 나타났다. 반면 정적인, 적막한, 소박한, 무거운, 우중충한, 어두운, 지저분한의 부정적 경관 이미지가 나타났는데, 이는 관리가 제대로 이루어지지 않기 때문으로 사료된다. 이러한 연구 결과를 통하여 패널형 입면녹화의 개발과 보급에 필요한 기초자료로 활용하고자 한다.

식생블록(그린스톤)에서의 식물생육에 관한 연구 - 관수 유무와 방향에 따른 생육비교를 중심으로 - (A Study on the Growth of Plants with Vegetation Blocks(Green Stone))

  • 김남춘;한승호;강진형
    • 한국환경복원기술학회지
    • /
    • 제6권2호
    • /
    • pp.57-70
    • /
    • 2003
  • The study was conducted to present the criteria of plant selection and planting design pattern suitable for the vegetation blocks which are becoming more popular for the facade greenery in urban areas. The main results are summarized as follows. 1. Under irrigated conditions, the plant grew better than that of unirrigated conditions and herbs grew better than shrubs. In selection of shrubs, it would be more proper to consider the size and depth of the pockets. 2. Under unirrigated conditions, Sedum middendorffianum and foreign sedums grew well, so it can be concluded that sedums can grow at low management condition. And, Hosta longipes and Aceriphyllum rossii could be survive at low management conditions only if irrigation was conducted at dry season. But, shrubs needed irrigation management for survival at vegetation blocks. 3. The results of this study, it can be concluded that greenery of walls and retaining walls might be effective for the creation of green space, improvement of urban landscapes, and the creation of diverse biotopes in urban areas with vegetation blocks.

숍 파사드 디자인 구성요소에 대한 선호도 연구 (A Study on the Preference of Design Components of Shop Facade)

  • 여미;오선애
    • 한국실내디자인학회논문집
    • /
    • 제24권2호
    • /
    • pp.171-179
    • /
    • 2015
  • The aim of this study is to figure out the preference features on design components of shop facade on the basis of the questionnaire survey on short-term memory and sensory memory of human right after an image experiment. As for a preceding research, this study examined the design features of facade into tangible elements and intangible elements, and also classified them into physical, aesthetical, marketing and symbolic components in detail. And, it extracted 5 representative elements in preceding studies including shape, material, pattern, color and sign, which is the standard of a questionnaire survey and preference analysis. The subjects of the experiment were 30 men and women who were over 20 years old majoring interior design. They were exposed to 20 images with 10 seconds respectively through a video, and were asked to respond the questionnaire promptly. The findings of preference analysis of design components of facade including shape, material, pattern, color and sign are as follows. Firstly, shape was the most interesting and attracting component, and designs applied with shape of objects such as 'web', 'drawer', 'wheel' and 'button' obtained high preference. Secondly, as for material, block, steel, exposed concrete board attracted higher preference as memorable materials than other materials. Material was affected by shape, pattern and color. Thirdly, pattern was the most lasting element. Designed pattern had higher preference than simple pattern. Fourthly, as for color, red and green with strong stimulation and attention attained priority having long lasting memory. Fifthly, when visiting a shop, sign out of 5 elements of shape, material, pattern, color and sign drew attention the most. As for the preference of location of sign, 'center top' was the most noticeable. The findings of this study could be utilized for facade design, and also could be used for commercialization considering highly preferred components, and top preference aspects of such elements. advised that to give an impression to customers is important to make a successful design for sales marketing, which, in turn, would lead customers to revisit the shop.

Facade 일체형 태양열 집열기를 갖는 태양열/지열 하이브리드 시스템의 태양열 집열시스템 작동특성 연구 (A Study on the Operating Characteristics of Solar Collecting System in Solar Thermal/Geothermal Hybrid System with Facade Integrated Solar Collector)

  • 백남춘;이진국;유창균;윤응상;윤종호
    • 한국태양에너지학회 논문집
    • /
    • 제30권5호
    • /
    • pp.69-76
    • /
    • 2010
  • In this study, the solar thermal and geo-source heat pump(GSHP) hybrid system for heating and cooling of Zero Energy Solar House(ZESH) was analyzed by experiment. The GSHP in this hybrid system works like as aback-up device for solar thermal system. This hybrid system was designed and installed for Zero Energy Solar House (KIER ZeSH) in Korea Institute of Energy Research. The purpose of this study is to find out that this system is optimized and operated normally for the heating load of ZeSH. The analysis was conducted as followings ; - the thermal performance of facade integrated solar collector - the on/off characteristics of solar system and GSHP - the contribution of solar thermal system. - the performance of solar thermal and ground source heat pump system respectively. - the meet of thermal load (space and water heating load). This experimental study could be useful for the optimization of this system as well as its application in house. This hybrid system could be commercialized for the green home if it is developed to a package type.

Case Studies on Space Zoning and Passive Façade Strategies for Green Laboratories

  • Kim, Jinho
    • Architectural research
    • /
    • 제22권2호
    • /
    • pp.41-52
    • /
    • 2020
  • Laboratory buildings with specialized equipment and ventilation systems pose challenges in terms of efficient energy use and initial construction costs. Additionally, lab spaces should have flexible and efficient layouts and provide a comfortable indoor research environment. Therefore, this study aims to identify the correlation between the facade of a building and its interior layout from case studies of energy-efficient research labs and to propose passive energy design strategies for the establishment of an optimal research environment. The case studies in this paper were selected from the American Institute of Architects Committee on the Environment Top Ten Projects and Leadership in Energy and Environmental Design (LEED) certified research lab projects. In this paper, the passive design strategies of space zoning, façade design devices to control heating and cooling loads were analyzed. Additionally, the relationships between these strategies and the interior lab layouts, lab support spaces, offices, and circulation areas were examined. The following four conclusions were drawn from the analysis of various cases: 1) space zoning for grouping areas with similar energy requirements is performed to concentrate similar heating and cooling demands to simplify the HVAC loads. 2) Public areas such as corridor, atrium, or courtyard can serve as buffer zones that employ passive solar design to minimize the mechanical energy load. 3) A balanced window-to-wall ratio (WWR), exterior shading devices, and natural ventilation systems are applied according to the space programming energy requirements to minimize the dependence on mechanical service. 4) Lastly, typical laboratory space zoning categories can be revised, reversed, and even reconfigured to minimize the energy load and adjust to the site context. This study can provide deep insights into various design strategies employed for construction of green laboratories along with intuitive arrangement of various building components such as laboratory spaces, lab support spaces, office spaces, and common public areas. The key findings of this study can contribute towards creating improved designs of laboratory facilities with reduced carbon footprint and greenhouse emissions.