• Title/Summary/Keyword: Green Capacity Coefficient

Search Result 21, Processing Time 0.019 seconds

Humidity Variation by Green Space Calculation Method (녹지의 산출방법이 습도변화에 미치는 영향)

  • Yoon, Yong-Han;Park, Heon
    • Asian Journal of Turfgrass Science
    • /
    • v.16 no.1
    • /
    • pp.41-47
    • /
    • 2002
  • For this study grasp quantitative humidity variation with planting stratification to various green space of calculation method, observed humidity distribution in the green space. with this data, coverage condition and humidity distribution, planting calculation method and humidity, planting stratification calculation method and humidity, analyzed by revolution analysis. In this result, as well as coverage condition, planting stratification effect humidity variation. increasing planting ratio (area) and planting volume (capacity) effect higher humidity. especially, if we compared between planting stratification calculation method and higher humidity, effect by a revolution coefficient and a correlation coefficient, effect relatively planting volume (capacity) higher than stratification ratio (area). today, in the index of higher humidity, planting calculation propose application of capacity method.

Analysis of Temperature Profiles by Land Use and Green Structure on Built-up Area (시가화지역 토지이용 및 녹지구조에 따른 온도변화 연구)

  • Hong Suk-Rwan;Lee Kyong-Jae;Han Bong-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.19 no.4
    • /
    • pp.375-384
    • /
    • 2005
  • This study was conducted selecting 44 places with a block unit subject to urban area in Gangnam-gu, to analyze a temperature change according to land use and green structure. In this study, it was used the broad-wide urban temperature, supported by Landset TM and ETM+ satellite image 6scene(1999${\~}$2002). The result of the research, the land use pattern has slightly influence on a temperature change of urban area. The result from correlation analysis between temperature and the factors affected by land cover type, such as building-to-land ratio(A correlation coefficient is 0.368${\~}$0.709) have positive correlation and green area ratio(a correlation coefficient is -0.551${\~}$-0.860) have negative correlation. The result from correlation analysis between temperature and green capacity of the land, crown projection area ratio, each factor have negative correlation with temperature, as showing that a correlation coefficient of green capacity of the land is -0.577(June 2006)${\~}$-0.882(June 1999) and crown projection area ratio's is -0.549(June 2001)${\~}$-0.817(June 1999). The result of the regression analysis for establishing urban area temperature change prediction model showed that green capacity of the land of the explanation variable was accepted.

Development of Model for Estimation of Green-Tourism Revenue on Rural Village by Factor Analysis (요인분석에 의한 농촌마을의 그린투어리즘 수익 추정 모형 개발)

  • Um, Dae-Ho;Kim, Tai-Cheol;Gim, Uhn-Soon
    • Journal of Korean Society of Rural Planning
    • /
    • v.12 no.4 s.33
    • /
    • pp.23-32
    • /
    • 2006
  • Recently, Owing to booming of leisure activities and national enforcement of 5-day workweek system, Korean government has been promoting rural tourism policy of which operating project's title is Green Rural Experience Village, Rural Traditional Theme Village, etc. In this study, ken investigation result on Green Rural Experience Village sites, an estimation model of returns by green-tourism activities was developed. The model was constructed through factor analysis and regression analysis method. Regression model developed can estimate green-tourism revenue by investment budget, homepage preengagement sales, homepage visitors, capacity of eating and drinking facilities, capacity of lodging facilities. The model developed was applied in sample villages. With these results, estimation revenue was recorded average 138.3% of survey revenue, and statistical significance was good(correlation coefficient $R^2$ = 0.8255, level of significance : 0.000), and the range of relative error was recorded largely from -7.1% to 158.6%, and average relative error was 38.3% and good. And, the model developed in this study have the critical point in aspects of insufficient data, but the results will be used in green-tourism policies and projects, and revenue estimation about each village in the present and future is limited, but in province or the whole country the application is good.

Axial capacity of reactive powder concrete filled steel tube columns with two load conditions

  • Wang, Qiuwei;Shi, Qingxuan;Xu, Zhaodong;He, Hanxin
    • Steel and Composite Structures
    • /
    • v.31 no.1
    • /
    • pp.13-25
    • /
    • 2019
  • Reactive powder concrete (RPC) is a type of ultra-high strength concrete that has a relatively high brittleness. However, its ductility can be improved by confinement, and the use of RPC in composite RPC filled steel tube columns has become an important subject of research in recent years. This paper aims to present an experimental study of axial capacity calculation of RPC filled circular steel tube columns. Twenty short columns under axial compression were tested and information on their failure patterns, deformation performance, confinement mechanism and load capacity were presented. The effects of load conditions, diameter-thickness ratio and compressive strength of RPC on the axial behavior were further discussed. The experimental results show that: (1) specimens display drum-shaped failure or shear failure respectively with different confinement coefficients, and the load capacity of most specimens increases after the peak load; (2) the steel tube only provides lateral confinement in the elastic-plastic stage for fully loaded specimens, while the confinement effect from steel tube initials at the set of loading for partially loaded specimens; (3) confinement increases the load capacity of specimens by 3% to 38%, and this increase is more pronounced as the confinement coefficient becomes larger; (4) the residual capacity-to-ultimate capacity ratio is larger than 0.75 for test specimens, thus identifying the composite columns have good ductility. The working mechanism and force model of the composite columns were analyzed, and based on the twin-shear unified strength theory, calculation methods of axial capacity for columns with two load conditions were established.

Improvement on Street Greenery for the Landscape Specialization and Increase of Green Volume on the Streets of Seoul (서울시 가로경관 특성화 및 녹량증진을 위한 가로녹지 개선 방안)

  • Byon, Hye-Ok;Han, Bong-Ho;Ki, Kyong-Seok;Jung, Jin-Mi
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.6
    • /
    • pp.35-46
    • /
    • 2012
  • This study attempts to specifically analyze green volume and scenery characteristics by classifying the streets in Seoul and suggest improvements accordingly. The subject streets for research were limited to those that have high occupancy ratio and are wide enough to have a big potential in improving green volume. In terms of green volume and scenery according to the types of streets, Platanus occidentalis and Ginkgo biloba were most common regardless of the street type, and the green ratio was 51.6% in residential areas, 50.4% in commercial areas, and 43.7% in business areas. Apart from the residential area, there was almost no green areas, and the ratio of green coverage was 71.0% in business areas, 64.0% in green areas, 37.3% in residential areas, and 36.2% in commercial areas, while the green volume coefficient was $1.9m^3/m^2$ on average. Based on the study results, it was set as a goal to provide the residential areas with a green community space and flowering trees throughout the year for scenery, and commercial areas with flowering trees and maples to emphasize the stores' image while not interfering with service and walking. For business areas, the goals were to improve green ratio and create streets that suit the urban image, and to set up spaces to provide habitat for wild animals with multi-layer planting and link to surrounding forests.

Development of a PTC Heater for Supplementary Heating in a Diesel Vehicle (디젤 차량의 보조 난방을 위한 PTC 히터 개발)

  • Shin, Yoon Hyuk;Kim, Sung Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.666-671
    • /
    • 2014
  • Using positive temperature coefficient (PTC) heater as supplementary heating for diesel engine vehicles with low heat source is a good method to enhance the heating performance during cold start. In this study, the PTC elements were made by using screen printing process for forming ohmic contact layer, and prototype of PTC heater was designed and made for a diesel engine vehicle. In process of designing the PTC heater, the thermal flow analysis of PTC element modules was conducted for verifying the effect of the shapes of contact surface between each of the components (cooling fin, insulator, ceramic element). We also investigated the performance characteristic (heating capacity, energy efficiency, pressure drop) of the PTC heater through the experiments. Therefore, the experimental results indicated that prototype of PTC heater had satisfactory performance. This study will be basis for improving the manufacturing process and increasing the performance of the PTC element and heater.

Performance Characteristics of Vehicle Air Conditioning System Using Internal Heat Exchanger with Inner Fin (휜 타입 내부열교환기 적용에 따른 차량용 냉방시스템 성능 특성)

  • Kim, Sung Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.69-73
    • /
    • 2013
  • Internal heat exchanger (IHX) apparatus using the temperature difference between high and low pressure lines in vehicle air conditioning system is a good method to enhance the cooling performance. In this study, we designed various double-pipe internal heat exchangers which have inner fins between the internal pipe and external pipe. We also measured the performance characteristic (pressure drop, cooling capacity, compressor work and coefficient of performance (COP)) of the modified internal heat exchangers that had the change of the fin height and the inside shape of the internal pipe. This experimental results indicated that the liner and serration type internal heat exchanger was the best cooling performance. In addition, the air conditioning system with the liner and serration type internal heat exchanger showed the improved performances of about 6.4% and 9.2%, respectively, for the cooling capacity and COP.

Ecological Characteristics and Management Program for Buffer Greens at Sinhyeon-Eup, Geoje-Si (거제시 신현읍 완충녹지의 생태적 특성 및 관리방안)

  • SaGong, Young-Bo;Lee, Soo-Dong
    • Korean Journal of Environment and Ecology
    • /
    • v.21 no.3
    • /
    • pp.243-256
    • /
    • 2007
  • The purpose of this paper is aimed at identifying the planting condition of greenbelt axis covering forests located at Sinhyeon-eup, Geoje-si and also establishing improvement plans for the ecological organization. The study was executed with buffer green space designed to mitigate noise, which is located at a halfway point linking Mt. Yukkyo(altitude of 50m) and Mt. Jungmae(altitude of 131m). The number of the biotope patterns was classified into 17 in total: the two are urbanized districts such as a townified district and streets and another 15 are greenbelts and open space such as forest biotope, inland water biotope, and landscaping tree plantations biotope. According to the analysis of biotope types, it was estimated that the making use of already established buffer greens as a linking medium with a foothold of Mt. Yukkyo and Jungmae, whose natural eco-system is well suited for habitation of living organism, is the one and only way to the influx of living organism into the downtown area. The green coverage rate of the base green area, sub-base green area and linkage green area was 160.29%, 128.37% and 44.37% respectively; the green capacity coefficient(i.e. GVZ[$Gr{\ddot{u}}nvolumezahl$]) for base green area, sub-base green area and linkage green area was $4.04m^3/m^2,\;3.95m^3/m^2\;and\;0.65m^3/m^2$ respectively. The base green area has constituted multi-layered vegetation structure and thus played a role as habitats for living organism and supply centre of species, whereas the sub-base green area has destroyed lower layer vegetation, and the linkage green area was in bad shape due to the lack of planting volume and damage of the shrub layer. Accordingly, this research paper intended to suggest detailed implementation plans for the improvement in landscape for city dwellers' use and relaxation; in other words, this paper focused on ecological build-up for the Influx of wild birds into the downtown area for the promotion of bio-diversity of species through the linkage of base green areas and the fostering of nature observing trails for citizens as well as the connecting of green areas through the build-up of roadside greens to make these green areas to be efficiently used as corridors for the influx of wild birds and bio-organism habitation and for citizens' using space.

Selection of the Most Sensitive Waveband Reflectance for Normalized Difference Vegetation Index Calculation to Predict Rice Crop Growth and Grain Yield

  • Nguyen Hung The;Lee Byun Woo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.49 no.5
    • /
    • pp.394-406
    • /
    • 2004
  • A split-plot designed experiment including four rice varieties and 10 nitrogen levels was conducted in 2003 at the Experimental Farm of Seoul National University, Suwon, Korea. Before heading, hyperspectral canopy reflectance (300-1100nm with 1.55nm step) and nine crop variables such as shoot fresh weight (SFW), leaf area index, leaf dry weight, shoot dry weight, leaf N concentration, shoot N concentration, leaf N density, shoot N density and N nutrition index were measured at 54 and 72 days after transplanting. Grain yield, total number of spikelets, number of filled spikelets and 1000-grain weight were measured at harvest. 14,635 narrow-band NDVIs as combinations of reflectances at wavelength ${\lambda}l\;and\;{\lambda}2$ were correlated to the nine crop variables. One NDVI with the highest correlation coefficient with a given crop variable was selected as the NDVI of the best fit for this crop variable. As expected, models to predict crop variables before heading using the NDVI of the best fit had higher $r^2$ (>10\%)$ than those using common broad- band NDVI red or NDVI green. The models with the narrow-band NDVI of the best fit overcame broad- band NDVI saturation at high LAI values as frequently reported. Models using NDVIs of the best fit at booting showed higher predictive capacity for yield and yield component than models using crop variables.

Developing Optimal Pre-Cooling Model Based on Statistical Analysis of BEMS Data in Air Handling Unit (BEMS 데이터의 통계적 분석에 기반한 공조기 최적 예냉운전 모델 개발)

  • Choi, Sun-Kyu;Kwak, Ro-Yeul;Goo, Sang-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.10
    • /
    • pp.467-473
    • /
    • 2014
  • Since the operating conditions of HVAC systems are different from those for which they are designed, on-going commissioning is required to optimize the energy consumed and the environment in the building. This study presents a methodology to analyze operational data and its applications. A predicted operation model is to be produced through a statistical data analysis using multiple regressions in SPSS. In this model, the dependent variable is the pre-cooling time, and the independent variables include the power output of the supply air inverter during pre-cooling, the supply air set temperature during pre-cooling, the indoor temperature-indoor set temperature just before pre-cooling, supply heat capacity, and the lowest outdoor air temperature during non-cooling/non-heating hours. The correlation coefficient R2 of the multiple regression model between the pre-cooling hour and the internal/external factors is of 0.612, and this could be used to provide information related to energy conservation and operating guidance.