• 제목/요약/키워드: Gravimetric Method

검색결과 209건 처리시간 0.031초

Correction Factors for Outdoor Concentrations of PM2.5 Measured with Portable Real-time Monitors Compared with Gravimetric Methods: Results from South Korea

  • Yun, Dong-Min;Kim, Myeong-Bok;Lee, Jun-Bok;Kim, Bo-Kyeong;Lee, Dong-Jae;Lee, Seon-Yeub;Yu, Sol;Kim, Sung-Roul
    • 한국환경과학회지
    • /
    • 제24권12호
    • /
    • pp.1559-1567
    • /
    • 2015
  • This study investigated the association between $PM_{2.5}$ concentrations obtained with portable real-time monitors and those obtained with gravimetric methods in national urban air-quality monitoring sites in Seoul, South Korea. We used the SidePak AM510 Personal Aerosol Monitor (TSI Inc., 500 Cardigan Road Shoreview, MN) and DustTrak DRX 8533 (TSI Inc., 500 Cardigan Road Shoreview, MN) as portable real-time monitors for measuring $PM_{2.5}$ concentrations and compared these values with those measured with the PMS-103 or SEQ 47/50 models operated by Federal Reference Method (FRM) or the European Committee for Standardization(ECS), respectively, in national urban air-quality monitoring sites in Seoul. Measurements were conducted every other day in the winter and spring seasons of 2014. The estimated daily mean concentrations of $PM_{2.5}$ ranged between 13.4 and $161.9{\mu}g/m^3$ using AM 510 and between 22.0 and $156.0{\mu}g/m^3$ using DustTrak. The Spearman correlation coefficient for $PM_{2.5}$ concentrations between AM 510 and gravimetric results was 0.99, and the correlation between DustTrak and gravimetric results was 0.87. The correction factor suggested was 0.42 and 0.29 for AM 510 and DustTrak, respectively. We found that $PM_{2.5}$ concentrations measured with real-time monitors could overestimate true $PM_{2.5}$ concentrations and therefore the application of a correction factor (0.43) is strongly suggested for quantification when Real-time monitors were operated of $PM_{2.5}$ levels at urban atmospheric environment of South Korea.

대기환경에서 광산란 미세먼지 측정기의 PM2.5 보정계수 산정 (Estimation of PM2.5 Correction Factor for Optical Particle Counter in Ambient Air)

  • 김종범;김단비;노수진;윤관훈;박덕신;이정주;김정호
    • 한국입자에어로졸학회지
    • /
    • 제16권2호
    • /
    • pp.49-59
    • /
    • 2020
  • Various devices have been developed to the measurement of particulate matter pollutants, and Optical Particle Counter (OPC) that can be easily and quickly measured is widely used lately. The measured value by OPC is converted to weight concentration using the correction factor (CF). The calculation of CF is very important to improve the reliability and accuracy of OPC. In this study, the CF calculation study of light scattering laser photometer (model 8533, TSI) was carried out to measure in the atmospheric environment using 2 gravimetric devices and 3 light scattering laser photometer devices. Regression analysis and Tukey tests were used to significance the test of measurement devices. Measurements were carried out twice. There was a comparative analysis of measurement data between light scattering laser photometer and gravimetric devices in 1st measurement, and then the Evaluation of PM2.5 concentration corrected by CF performed in 2nd measurement. As a result of the significance analysis between light scattering laser photometer and gravimetric devices, the correlation between the same method was high, but the correlation between different methods was low. CF was calculated as 0.4258 based on the measurement results, and it is a similar level to previous studies at home and abroad. It is expected that these results can be used as basic data in the future study for air quality measurement research using light scattering laser photometer. Also, in order to improve the accuracy of the measurement techniques and the development of technology in the atmospheric environment, CF calculation research should be conducted continuously.

대기 중 TSP와 PM10 농도의 관련성 (Relationships between TSP and PM10 Concentrations in the Ambient Atmosphere)

  • 최진수;백성옥
    • 한국대기환경학회지
    • /
    • 제14권1호
    • /
    • pp.1-10
    • /
    • 1998
  • Relationships between TSP and PM10 concentrations were evaluated using their respective data sets collected from Taegu and Kyeungsan areas during the period of December 1993 to November 1994. The collection of data was made using the gravimetric and $\beta$-ray absorption ($\beta$-MPM) methods for 7 days of every month from three urban sites in Taegu and one suburban site in Kyeungsan. Correlation coefficients between TSP and PM10 concentrations for these four sampling sites were found in the range of 0.85 $\sim$ 0.96. Correlation analysis was also conducted for $\beta$-PM concentration data that were measured only from the residential and commercial sites. The correlation coefficients between TSP and $\beta$-PM concentrations were 0.9 in the residential site and 0.8 in the commercial site. By contrast, the correlation coefficients between PM10 $\beta$-PM concentrations were almost identical for both the residential and commercial sites with a value of 0.88. The mean ratio for PM10 to TSP concentrations for all sites was appeared to be 0.68. The analysis of seasonal trends in PM10/TSP ratios showed that the contribution of PM10 to TSP concentrations was more significant during winter (0.70 $\sim$ 0.75) than during summer (0.61 $\sim$ 0.68). The results of this study may provide empirical informations on the compatability of aerosol data measured by different sampling methods.

  • PDF

선박용 4행정 디젤엔진의 정속 부하변동 운전시 매연배출특성에 대한 실험연구 (An Experimental Study on the Emission Characteristics of Smoke from the Marine Four-Stroke Diesel Engines Operated in Constant Speed and Various Load Steps)

  • 오상훈;김재민;김현규;유봉환
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.19-20
    • /
    • 2006
  • The emission of particulate matter from marine diesel engines is already restricted by regional regulations in some countries, and IMO has been preparing the regulation for particulate matter from 53rd MEPC. But confusingly, the gravimetric PM measurement methods and procedures are not established clearly yet. On the other hand, smoke measurement method is set clearly, and it can also indicate PM, though it is not direct gravimetric method. As the preparing step for regulations about PM, we measured the smote density of exhaust emission from the marine four-stroke diesel engines operated in constant speed and various load steps on the test-bed, using the filter-type smoke measuring instrument. As a result, we understood the omission characteristics of smoke from the engines. Additionally, to obtain the objective reliability of our measurement data, we carried out experimental studies about various measuring parameters that could affect the smoke density.

  • PDF

혼합 액체연료의 화학반응차수 계측에 관한 실험적 연구 (An Experimental Study on Measurement of the Reaction Order of a Liquid Fuel with Various Components)

  • 최효현;임준석;김철진;손채훈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.421-424
    • /
    • 2011
  • 본 연구에서는 열분석법을 이용하여 혼합 액체연료의 수치해석에 필요한 여러 가지 인자를 측정하였다. 이러한 열분석법에는 열중량 분석방법(TGA, Thermo-Gravimetric Analyzer)과 시차 주사열량 측정법(DSC, Differential Scanning Calorimetry)이 있다. 열중량 분석방법을 통한 비등온 실험(non-isothermal experimental) 결과를 토대로 Freeman Carroll의 수학적인 후처리 방법을 이용하여 미지의 액체연료의 구성 성분에 대한 동역학적 변수인 활성화 온도와 반응차수로 각각 6128.2 K와 1.4를 얻었다. 그 외 다양한 수학적 처리 방법에 따른 동역학적 변수의 값을 구해보았고, 계산 결과는 처리방법에 따라 약간의 차이를 보였다.

  • PDF

중성화 측정을 통한 콘크리트의 잔존수명 예측 (A Prediction of Remaining Service Life of Concrete for Irrigation Structure by Measuring Carbonation)

  • 이준구;박광수;신수균;김관호;윤성수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.773-778
    • /
    • 2002
  • The variance characteristics of the calcium carbonate contents along to the concrete cover depth takes the prediction method of remaining service life of concrete. Calcium carbonate contents were measured by the Thermo Gravimetric/Differential Thermal Analysis method at three point, depth of 0.25cm, 0.75cm, 1.25cm from the surface of concrete. This prediction method contain some assumption that the chemical protection conferred on steel is through a passive protective oxide film which forms on steel in an environment at or above a pH of 10.5$^{4)}$ .

  • PDF

Sulfa제-Cu착화합물의 형성에 관하여 II Spectrophotometry 에 의한 Copper Sulfa-Drug Complex 의 화학조성결정 (Studies on the Formation of Copper Complexes of Sulfa-Drug II.Study on Chemical Constisuent of Copper Sulfa-Drug Complex by Continuous Variation Method.)

  • 이왕규
    • 약학회지
    • /
    • 제8권4호
    • /
    • pp.96-99
    • /
    • 1964
  • In the previous study, the composition ratios of the Cu-sulfa drugs complexes determined by gravimetric and solvent extraction method reported. In this paper, the continuous variations method has been used to know whether the complexes are simple complexes or chelates, and to recertify the composition ratios of the complexes at pH 7-8. It has been certified that the ratio of $Cu^{+2}$ ion to sulfa drugs in 1:2 from the result of this experiment.

  • PDF

소포제중 실리콘 오일의 함량에 대한 분석 (Quantitative Analysis of Silicone Oil in Antifoaming Agent)

  • 김경숙;양석란;임춘식;박현주
    • 대한화학회지
    • /
    • 제44권4호
    • /
    • pp.337-342
    • /
    • 2000
  • 현재 한전의 화력발전소에서 사용되는 실리콘 오일계 소포제의 품질관리를위해 각종 실험을 실시한 결과 제조업체별로 다른 계면활성제 (예를 들면 유화제와증점제)를 사용하고 있어 가가의 소포제는 특징적인 물성을 나타냄을 확인할 수 있었다. 보다 간편하면서도 정확한 소포제의 품질관리를 위해 고안된본 실험은 소포제에 사용된 계면활성제의 종류나 양에 관계없이 소포제에 함유된 실리콘 오일의 정확한 함량을 측정하고자 시도하였다. 우선 매우 간단한 실험 기구로 행할수 있은 중량법이나 원심분리법을 사용하여 실리콘 오일의 함량을 구한 다음, FT-IR에 의한 분광법을 사용하여 비교${\cdot}$확인하였다. 원심분리법은 바탕실험과 실제 소포제에 대해 적용한 결과, 소포제 내의 실리콘 오일의 전량 회수되지 않으므로 오일 함량의 분석에는 좋은 방법이 될 수 없음을 확인하였다. 한편 일부 회사에서 제조된 소포제의 경우 이들 방법 사리에 상당한 차이를 나타내었다. 비교실험 결과, FT-IR에 의한 분광법이 적은 시료의 양으로 짧은 시간내에 손쉽게 분석이 가능하고 좋은 재현상을 나타내므로, 언급한 전처리 방법과 함께 사용할 경우 첨가된 계면활성제의 종류와 양에 관계없이 좋은 결과를 얻을 수 있다고 판단된다.

  • PDF

Sulfa제-Cu 착화합물의 형성에 관하여 (Studies on the formation of Copper Compelxes of Sulfa-Drug.)

  • 이왕규
    • 약학회지
    • /
    • 제7권1호
    • /
    • pp.13-17
    • /
    • 1963
  • The purpose of this work is to investigate the molar ratio, the precipitation condition and the color of copper sulfa-drugs complexes. The colors of the complexes are observed at every precipitation condition is obtained as pH 7-9. The determination of the molar ratio of complexes is able to be carried out by way of gravimetric method and solvent extraction method. The molar ratios of sulfa-drugs and copper in identified complexes are 2:1 when utilizing both methods.

  • PDF