• Title/Summary/Keyword: Graft occlusion

Search Result 120, Processing Time 0.023 seconds

Atrophic Alveolar Ridge Augmentation using Autogenous Block Bone Graft for Implant Placement (임플란트 식립을 위해 블록형 자가골이식을 이용한 퇴축된 치조골의 재건)

  • Chee, Young-Deok;Cho, Jin-Hyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.2
    • /
    • pp.161-171
    • /
    • 2006
  • Endosseous implants have restored normal function and dental health to many patients. When implants were introduced as an effective treatment modality, their efficacy was limited by the amount of available bone. Today, various grafting procedures can surgically create bone width and volume. Implants can be placed in more ideal locations for successful prosthetic reconstruction. The use of autogenous bone grafts represents the "gold standard" for bone augmentation procedures. Either intraoral or extraoral sites may be considered for donor sites. Alveolar ridge augmentation using autogenous bone block, can be done during implant placement or staged with implant placement, after bone graft healing. In the staged technique, a better implant positioning and the use of wide diameter implants are possible. Alveolar ridge augmentation using autogenous block graft is a predictable way of treatment, for the atrophic alveolar ridge before implant placement. The cases presented in this article clinically demonstrate the efficacy of using a autogenous block graft in generating effective new bone fill for dental implant placement.

Blood Compatibility of Artificial Blood-Contacting Surface Seeded with Cultured Bovine Endothelial Cells (소폐동맥 내피세포를 이용한 인조혈액접촉표면의 혈액 접합성)

  • 김원곤;곽영태;유세영
    • Journal of Chest Surgery
    • /
    • v.26 no.2
    • /
    • pp.80-85
    • /
    • 1993
  • Synthetic and biosynthetic vascular grafts of small diameter have long been considered to be prone to thrombosis, ultimately leading to the complete graft occlusion. Endothelial cell seeding onto synthetic blood-contacting surfaces has been suggested to be an ideal means to solve this problem. This study described a culture method of bovine endothelial cells and evaluated blood-compatibility and seeding efficiency of cultured endothelial cells. Bovine pulmonary artery endothelial cells were harvested enzymatically and grown to confluence on polystyrene culture flask surfaces using established techniques. The identification of endothelial cells was made through the demonstration of expression of factor VIII R:Ag by immunofluorescent technique. To quantitate the effect of improvement in blood-compatibility of viable endothelial cells, endothelial monolayers were exposed to blood containing $\^$111/In-oxine labeled platelets. Viable endothelial monolayers retained less labeled platelets than control surfaces. The Indium-labeled endothelial cells were seeded onto three different blood-contacting surfaces of Dacron vascular graft immobilized in specially equipped wells and incubated for specific time intervals (t=15, 30, 60, 120 minutes). Longer incubation times showed improved cell adherence in collagen-coated and fibrin-coated Dacron vascular graft groups. However in untreated Dacron grafts, no direct relationship was observed between incubation time and endothelial cell seeding efficiency. This may be due to leakage of endothelial cells through porosity of Dacron grafts in this in-vitro experimental condition.

  • PDF

Comparison of Outcomes of Hybrid and Surgical Correction for De Novo Arteriovenous Graft Occlusion

  • Ko, Dai Sik;Choi, Sang Tae;Lee, Won Suk;Chun, Yong Soon;Park, Yeon Ho;Kang, Jin Mo
    • Vascular Specialist International
    • /
    • v.34 no.4
    • /
    • pp.88-93
    • /
    • 2018
  • Purpose: This study aimed to compare surgical revisions and balloon angioplasty after surgical thrombectomy on thrombosed dialysis access as a first event. Materials and Methods: Records of patients undergoing creation of arteriovenous grafts (AVGs) at the Gachon University Gil Medical Center between March 2008 and February 2016 were reviewed. Among them, patients who underwent treatment on first-time thrombotic occlusion after AVG creation were identified. Outcomes were primary, primary-assisted, and secondary patency. The patency was generated using the Kaplan-Meier method, and patency rates were compared by log-rank test. Results: A total of 59 de novo interventions (n=26, hybrid interventions; n=33, surgical revisions) for occlusive AVGs were identified. The estimated 1-year primary patency rates were 47% and 30% in the surgery and hybrid groups, respectively. The estimated primary patency rates were not different between the two groups (log-rank test, P=0.73). The Kaplan-Meier estimates of 6 and 12 months for primary-assisted patency rates were 68% and 57% in the surgery group and 56% and 56% in the hybrid group. The Kaplan-Meier estimates of 12 and 24 months secondary patency rates were 90% and 71% in the surgery group and 79% and 62% in the hybrid group. There were no differences in the estimated primary-assisted and secondary patency rates between the two groups. Conclusion: Our results showed no significant difference between the two groups in terms of primary patency (P=0.73), primary-assisted patency (P=0.85), and secondary patency (P=0.78). However, percutaneous transluminal angioplasty can give more therapeutic options for both surgeons and patients.

Central Vein Occlusion Secondary to Hemodialysis Catheterization in Chronic Renal Failure Patient -One Case Report- (만성 신부전 환자에서 혈액투석 도관에 의한 중심정맥 폐쇄증의 수술치험 -1례 보고-)

  • Lee, Seock-Yeol;Lee, Jun-Bock;Lee, Man-Bok;Youm, Wook;Lee, Kihl-Rho
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.619-623
    • /
    • 1998
  • A 51-year-old male with chronic renal failure had marked swelling and tenderness of the right arm. Venography revealed central vein occlusion involving stenosis of right proximal subclavian vein, right internal jugular vein, and left distal innominate vein, and obstruction of right brachiocephalic vein. Multiple obstruction of these veins was thought to have resulted from repeated subclavian catheterization. Right subclavian-superior vena cava was bypassed with 10 mm Gore-tex vascular graft and then left subclavian vein with 8 mm Gore-tex vascular graft was bypassed to the 10 mm Gore-tex vascular graft. The results were excellent.

  • PDF

Effect of the Proximal Anastomosis Configuration of the Radial Artery in Patients Undergoing Coronary Artery Bypass Grafting

  • Yoon, Seung Keun;Song, Hyun;Lim, Ju Yong
    • Journal of Chest Surgery
    • /
    • v.54 no.2
    • /
    • pp.117-126
    • /
    • 2021
  • Background: Several factors, such as the degree of target vessel stenosis, are known to be associated with radial artery (RA) graft patency in coronary artery bypass grafting (CABG). There is a lack of data regarding the effect of the RA proximal configuration (aortic anastomosis versus T-anastomosis). This study evaluated the effects of the RA proximal configuration on the patency rate and clinical outcomes after CABG. Methods: We conducted a retrospective study, analyzing 328 patients who had undergone CABG with an RA graft. We divided the patients into 2 groups. The primary endpoint was RA patency and the secondary endpoints were overall mortality and major adverse cardiac and cerebrovascular events (MACCE). We performed a propensity score-matched comparison. Results: Aorta-RA anastomosis was performed in 275 patients, whereas the rest of the 53 patients received T-RA anastomosis. The mean age was 67.3±8.7 years in the T-RA anastomosis group and 63.8±9.5 years in the aorta-RA anastomosis group (p=0.02). The mean follow-up duration was 5.13±3.07 years. Target vessel stenosis ≥70% (hazard ratio [HR], 0.42; 95% confidence interval [CI], 0.20-0.91; p=0.03) and T-RA anastomosis configuration (HR, 2.34; 95% CI, 1.01-5.19; p=0.04) were significantly associated with RA occlusion in the multivariable analysis. However, T-RA anastomosis was not associated with higher risks of overall mortality and MACCE following CABG (p=0.30 and p=0.07 in the matched group, respectively). Conclusion: Aorta-RA anastomosis showed a superior patency rate compared to T-RA anastomosis. However, the RA proximal anastomosis configuration was not associated with mortality or MACCE.

Comparison of Clinical Outcomes in Patients Undergoing a Salvage Procedure for Thrombosed Hemodialysis Arteriovenous Grafts

  • Park, You Kyeong;Lim, Jae Woong;Choi, Chang Woo;Her, Keun;Shin, Hwa Kyun;Shinn, Sung Ho
    • Journal of Chest Surgery
    • /
    • v.54 no.6
    • /
    • pp.500-508
    • /
    • 2021
  • Background: The major limitation of arteriovenous graft access is the high incidence of thrombotic occlusion. This study investigated the outcomes of our salvage strategy for thrombosed hemodialysis arteriovenous grafts (including surgical thrombectomy with balloon angioplasty) and evaluated the efficacy of intragraft curettage. Methods: Salvage operations were performed for 290 thrombotic occluded arteriovenous grafts with clinical stenotic lesions from 2010 to 2018. Of these, 117 grafts received surgical thrombectomy and balloon angioplasty from 2010 to 2012 (group A), and 173 grafts received surgical thrombectomy and balloon angioplasty, with an additional salvage procedure using a curette and a graft thrombectomy catheter, from 2013 to 2018 (group B). Outcomes were described in terms of post-intervention primary patency and secondary patency rates. Results: The post-intervention primary patency rates in groups A and B were 44.2% and 66.1% at 6 months and 23.0% and 38.3% at 12 months, respectively (p=0.003). The post-intervention secondary patency rates were 87.6% and 92.6% at 6 months and 79.7% and 85.0% at 12 months, respectively (p=0.623). Multivariate Cox regression analysis demonstrated that intragraft curettage was a positive predictor of post-intervention primary patency (hazard ratio, 0.700; 95% confidence interval, 0.519-0.943; p=0.019). Conclusion: Surgical thrombectomy and balloon angioplasty showed acceptable outcomes concerning post-intervention primary and secondary patency rates. Additionally, intragraft curettage may offer better patency to salvage thrombotic occluded arteriovenous grafts with intragraft stenosis.

Changes in Bypass Flow during Temporary Occlusion of Unused Branch of Superficial Temporal Artery

  • Kim, Joon-Young;Jo, Kwang-Wook;Kim, Young-Woo;Kim, Seong-Rim;Park, Ik-Seong;Baik, Min-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.2
    • /
    • pp.105-108
    • /
    • 2010
  • Objective : Some neurosurgeons intentionally ligate the branches of the superficial temporal artery (STA) that are not used in standard STA-to-middle cerebral artery (MCA) anastomosis for the purpose of improving the flow rate in the bypass graft. We investigated changes in bypass flow during temporary occlusion of such unused branches of the STA. Methods : Bypass blood flow was measured by a quantitative microvascular ultrasonic flow probe before and after temporary occlusion of branches of the STA that were not used for anastomosis. We performed measurements on twelve subjects and statistically assessed changes in flow. We also examined all the patients with digital subtraction angiography in order to observe any post-operative changes in STA diameter. Results : Initial STA flow ranged from 15 mL/min to 85 mL/min, and the flow did not change significantly during occlusion as compared with preocclusion flow. The occlusion time was extended by 30 minutes in all cases, but this did not contribute to any significant flow change. Conclusion : The amount of bypass flow in the STA seems to be influenced not by donor vessel status but by recipient vessel demand. Ligation of the unused STA branch after completion of anastomosis does not contribute to improvement in bypass flow immediately after surgery, and furthermore, carries some risk of skin necrosis. It is better to leave the unused branch of the STA intact for use in secondary operation and to prevent donor vessel occlusion.

Evaluation of the Volume Changes of Grafted Bone Materials in Sinus Augmentation Procedure Using Dental Cone-beam CT (치과용 Cone-beam CT를 이용한 상악동 골 이식 후 나타난 골 이식재의 부피 변화평가)

  • Ohn, Byung-Hun;Seon, Hwa-Kyeong;Chee, Young-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.23-36
    • /
    • 2013
  • To evaluate the 3-dimensional features of the grafted bone with maxillary sinus augmentation and to assess the relation between the degree of bone resorption and the type of bone grafting source and implant, and the operation method. A retrospective chart review of patients receiving sinus augmentation procedures for implant positioning was conducted: radiographic analysis of the volume and area of bone grafts was performed. The volumetric remodeling.measured at 6 months after implant positioning as the percentage of residual bone graft.was correlated to type of graft materials and operation methods. 53 dental implants positioned with sinus bone graft in 15 patients at Wonkwang University Sanbon Dental Hospital. Computed tomography scans,taken implant positioning after 6 months, showed greater resorption values for the group of $Puros^{(R)}$ graft alone from the group of mixed with $Puros^{(R)}$ and various bone graft (P<0.05, respectively). And resorption values according to operation methods have statistically significant difference(P<0.05). Volume change ratio of bone graft showed greater values for the group of delayed implant position from the group of simultaneously implant placement with bone graft. Retrospective data analysis shows that the method of graft with $Puros^{(R)}$ alone may occur greater resorption of graft materials than mixed graft material with $Puros^{(R)}$ and other graft materials. The group of simultaneously implant placement with bone graft also display smaller resorption ratio of bone graft than the group of delayed implant placement.

In Situ Saphenous Vein Arterial Bypass - A case report - (자연위치의 복재정맥을 이용한 하지동맥 우회술 1례 보)

  • Lee, Hong-Seop;Park, Guk-Yang;Kim, Chang-Ho
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.187-190
    • /
    • 1987
  • The Saphenous vein is still the graft of choice for bypass of small calibered peripheral arteries, and many recent studies revealed that the "In Situ" technique had higher rate of long term patency than the conventional "reversed" one. A 71-year-old male who had atherosclerotic obstruction in the superficial femoral and popliteal trifurcation underwent In Situ saphenous vein arterial bypass. The saphenous vein is exposed by a long medial skin incision over the course of the vein. All branches of vein are ligated. A olive-tipped metal needle is introduced into the vein from above and everts the valves. The patient has been followed for 2 months after operation. The graft remained pulsatile and the gangrenous areas on the toe proceeded to heal. We think In situ vein bypass offers an excellent and safe method of revascularization of the arterial occlusion below the knee although it is technically demanding and the time consuming. time consuming.

  • PDF

골수줄기세포가 배양된 생분해성 매트릭스를 이용한 소구경 인공혈관 개발

  • Jo, Seung-U;Im, Sang-Hyeon;Kim, Il-Gwon;Hong, Yu-Seon;Yu, Gyeong-Jong;Park, Hyeon-Yeong;Choe, Cha-Yong;Kim, Byeong-Su
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.45-47
    • /
    • 2002
  • Although Dacron and ePTFE have most widely been used for artificial vascular grafts, these materials cannot be used for small-diameter grafts (l.D.<6mm) due to thrombotic occlusion. To overcome this limitation, a small-diameter vascular graft was developed with stem cell and tissue engineering method. Autologous bone marrow stem cells were cultured and seeded onto small-diameter (4mm) collagen tubular matrices. The matrices were anastomosed to carotid arteries in canine models. Prior to implantation, histological and electron microscopical examination revealed stem cell adhesion and growth on the matrices. Angiography indicated that the vascular grafts maintained patent for 8 weeks. Histological examination showed the regeneration of endothelium, media and adventitia in the grafts. This study may allow us to step forward to the development of tissue-engineered small-diameter vascular graft appropriate for clinical applications.

  • PDF