Changes in Bypass Flow during Temporary Occlusion of Unused Branch of Superficial Temporal Artery

  • Kim, Joon-Young (Department of Neurosurgery, Bucheon St. Mary's Hospital, The Catholic University of Korea Collegs of Medicine) ;
  • Jo, Kwang-Wook (Department of Neurosurgery, Bucheon St. Mary's Hospital, The Catholic University of Korea Collegs of Medicine) ;
  • Kim, Young-Woo (Department of Neurosurgery, Bucheon St. Mary's Hospital, The Catholic University of Korea Collegs of Medicine) ;
  • Kim, Seong-Rim (Department of Neurosurgery, Bucheon St. Mary's Hospital, The Catholic University of Korea Collegs of Medicine) ;
  • Park, Ik-Seong (Department of Neurosurgery, Bucheon St. Mary's Hospital, The Catholic University of Korea Collegs of Medicine) ;
  • Baik, Min-Woo (Department of Neurosurgery, Bucheon St. Mary's Hospital, The Catholic University of Korea Collegs of Medicine)
  • Received : 2010.05.19
  • Accepted : 2010.08.09
  • Published : 2010.08.28

Abstract

Objective : Some neurosurgeons intentionally ligate the branches of the superficial temporal artery (STA) that are not used in standard STA-to-middle cerebral artery (MCA) anastomosis for the purpose of improving the flow rate in the bypass graft. We investigated changes in bypass flow during temporary occlusion of such unused branches of the STA. Methods : Bypass blood flow was measured by a quantitative microvascular ultrasonic flow probe before and after temporary occlusion of branches of the STA that were not used for anastomosis. We performed measurements on twelve subjects and statistically assessed changes in flow. We also examined all the patients with digital subtraction angiography in order to observe any post-operative changes in STA diameter. Results : Initial STA flow ranged from 15 mL/min to 85 mL/min, and the flow did not change significantly during occlusion as compared with preocclusion flow. The occlusion time was extended by 30 minutes in all cases, but this did not contribute to any significant flow change. Conclusion : The amount of bypass flow in the STA seems to be influenced not by donor vessel status but by recipient vessel demand. Ligation of the unused STA branch after completion of anastomosis does not contribute to improvement in bypass flow immediately after surgery, and furthermore, carries some risk of skin necrosis. It is better to leave the unused branch of the STA intact for use in secondary operation and to prevent donor vessel occlusion.

Keywords

References

  1. Alaraj A, Ashley WW Jr, Charbel FT, Amin-Hanjani S : The superficial temporal artery trunk as a donor vessel in cerebral revascularization : benefits and pitfalls. Neurosurg Focus 24 : E7, 2008
  2. Amin-Hanjani S, Charbel FT : Flow-assisted surgical technique in cerebrovascular surgery. Surg Neurology 68 : S4-S11, 2007 https://doi.org/10.1016/j.surneu.2007.07.051
  3. Charbel FT, Hoffman WE, Misra M, Ostergren L : Ultrasonic perivascular flow probe : technique and application in neurosurgery. Neurol Res 20 : 439-442, 1998 https://doi.org/10.1080/01616412.1998.11740545
  4. Charbel FT, Meglio G, Amin-Hanjani S : Superficial temporal arteryto- middle cerebral artery bypass. Neurosurgery 56 : 186-190; discussion 186-190, 2005
  5. Failure of extracranial-intracranial arterial bypass to reduce the risk of ischemic stroke. Results of an international randomized trial. The EC/IC Bypass Study Group. N Engl J Med 313 : 1191-1200, 1985 https://doi.org/10.1056/NEJM198511073131904
  6. Ishii K, Morishige M, Anan M, Sugita K, Abe E, Kubo T, et al. : Superficial temporal artery-to-middle cerebral artery anastomosis with encephalo- duro-myo-synangiosis as a modified operative procedure for moyamoya disease. Acta Neurochir Suppl 107 : 95-99, 2010 https://doi.org/10.1007/978-3-211-99373-6_15
  7. Kang SD : Extracranial-intracranial bypass surgery : surgical techniques and perioperative management. Korea J Cerebrovasc Dis 4 : 119-123, 2002
  8. Little JR, Furlan AJ, Bryerton B : Short vein grafts for cerebral revascularization. J Neurosurg 59 : 384-388, 1983 https://doi.org/10.3171/jns.1983.59.3.0384
  9. Lundell A, Bergqvist D, Mattsson E, Nilsson B : Volume blood flow measurements with a transit time flowmeter : an in vivo and in vitro variability and validation study. Clin Physiol 13 : 547-557, 1993 https://doi.org/10.1111/j.1475-097X.1993.tb00470.x
  10. Nussbaum ES, Erickson DL : Extracranial-intracranial bypass for ischemic cerebrovascular disease refractory to maximal medical therapy. Neurosurgery 46 : 37-42; discussion 42-43, 2000 https://doi.org/10.1093/neurosurgery/46.1.37
  11. Nussbaum ES, Janjua TM, Defillo A, Lowary JL, Nussbaum LA : Emergency extracranial-intracranial bypass surgery for acute ischemic stroke. J Neurosurg 112 : 666-673, 2010 https://doi.org/10.3171/2009.5.JNS081556
  12. Onesti ST, Solomon RA, Quest DO : Cerebral revascularization : a review. Neurosurgery 25 : 618-628; discussion 628-629, 1989 https://doi.org/10.1227/00006123-198910000-00017
  13. Scharf J, Schmiedek P, Kemmling A, Gerigk L, Groden C, Horn P : Spontaneous recanalization of occluded standard extracranial-intracranial arterial bypass. Cerebrovasc Dis 23 : 175-180, 2007 https://doi.org/10.1159/000097056
  14. Schmiedek P, Piepgras A, Leinsinger G, Kirsch CM, Einhüpl K : Improvement of cerebrovascular reserve capacity by EC-IC arterial bypass surgery in patients with ICA occlusion and hemodynamic cerebral ischemia. J Neurosurg 81 : 236-244, 1994 https://doi.org/10.3171/jns.1994.81.2.0236
  15. Wanebo JE, Zabramski JM, Spetzler RF : Superficial temporal arteryto- middle cerebral artery bypass grafting for cerebral revascularization. Neurosurgery 55 : 395-398; discussion 398-399, 2004 https://doi.org/10.1227/01.NEU.0000129549.99061.94

Cited by

  1. Endovascular internal carotid artery trapping for ruptured blood blister-like aneurysms: long-term results from a single centre vol.56, pp.3, 2014, https://doi.org/10.1007/s00234-014-1317-3