• Title/Summary/Keyword: Gradual injection

Search Result 47, Processing Time 0.022 seconds

A New Snap-back Suppressed SA-LIGBT with Gradual Hole Injection (점진적인 홀의 주입을 통해 스냅백을 억제한 새로운 구조의 SA-LIGBT)

  • Jeon, Jeong-Hun;Lee, Byeong-Hun;Byeon, Dae-Seok;Lee, Won-O;Han, Min-Gu;Choe, Yeol-Ik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.2
    • /
    • pp.113-115
    • /
    • 2000
  • The gradual hole injection LIGBT (GI-LIGBT) which employs the dual gate and the p+ injector, was fabricated for eliminating a negative resistance regime and reducing a forward voltage drop in SA-LIGBT. The elimination of the negative resistance regime is successfully achieved by initiating the hole injection gradually. Furthermore, the experimental results show that the forward voltage drop of GI-LIGBT decreases by lV at the current density of 200 $A/cm^2$, when compared with that of the conventional SA-LIGBT. It is also found that the improvement in the on-state characteristics can be obtained without sacrificing the inherent fast switching characteristics of SA-LIGBT.

  • PDF

Characteristics of milk fever and mastitis following different milking method and preventive calcium injection performed during the colostrum period in dairy cattle

  • Jeon, Ryounghoon
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.35 no.3
    • /
    • pp.273-278
    • /
    • 2020
  • The milk fever and mastitis that occur during the colostrum period in dairy cattle cause great damage in the dairy industry by causing a rapid decline in the cattle's health and decreasing milk production. In order to prevent this, gradual milking (GM), calcium injection with gradual milking (CG), and calcium injection with complete milking (CC) methods are used. However, differences in effectiveness between these methods have not been established. Therefore, this study was conducted to determine the effects of each preventive method on milk fever and mastitis. The results of this study showed that while there was a significant negative correlation of GM with milk fever and mastitis (r = -0.657, p < 0.05), there was no correlation of CG and CC with milk fever and mastitis. The incidence of milk fever was significantly lower in CG and CC than in GM (p < 0.05) but no differences in the incidence of mastitis were observed between the three groups. No significant differences in the rate of recovery from milk fever and mastitis were observed between the three groups. The recurrence rate of milk fever was significantly higher in CG and CC than in GM (p < 0.05), though no differences in the recurrence rate of mastitis were observed. This study showed an inverse relationship between the incidence rates of milk fever and mastitis when calcium injection was not used during the colostrum period. When calcium injections were used, the incidence of milk fever was reduced without affecting the incidence of mastitis regardless of the milking method, but the recurrence rate of milk fever was increased. The results of this study would be useful for controlling blood calcium concentrations and establishing efficient milking strategy in order to effectively prevent milk fever and mastitis in dairy cattle during the colostrum period.

Electrokinetic Injection characteristics of Ions into Kaolinite and Sand for Bioremediation (토질에 따른 Electrokinetic 이온 주입 특성)

  • 한상재;이호창;김수삼
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.1
    • /
    • pp.15-24
    • /
    • 2002
  • Nowdays electrokinetic technique has been applied to supply nutrients and TEAs for in-situ bioremediation. However the Injection characteristics under electrical field have not been examined in various soil types. Therefore, The characteristics of electrokinetic injection into kaolinite and sand are investigated. During the 17 d of processing, There was a gradual increase in ammonium (nutrient) concentration from the anode compartment. However the ammonium concentration at the cathode increased beyond that at the anode in sand. A relatively constant profile of sulfate (TEA) was achieved specifically, the final sulfate concentration in each specimen were different. When EK injection technique is implemented in field, the most important consideration should be an assessment of the injection characteristics with respect to the soil types.

The Effects of Water Mist on the Compartment Fire

  • Ryou, Hong-Sun;Kim, Sung-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.1
    • /
    • pp.30-36
    • /
    • 2004
  • The present study investigates the fire suppression characteristics using a water mist fire suppression system. Numerical simulations of fire suppression with water mist are performed with considering the interaction of fire plume and water spray. The predicted temperature fields of smoke layer are compared with those of measured data. Numerical results agree with the experimental results within $10^{\circ}C$ in the case without water mist. In the case of fire suppression with water mist, numerical results do not predict well for temperature field in the gradual cooling region after water mist injection. But the predicted results of initial fire suppression are in good agreement with those of measured data. The reason for the discrepancy between predicted and measured data is due to the poor combustion modeling during the injection of water mist. More elaborate models for numerical simulation are required for better predictions of the fire suppression characteristics using water mist.

A Study on the Fire Suppression Characteristics Using a Water Mist (물분무에 의한 화재제어 특성에 관한 연구)

  • 김성찬;유홍선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.261-267
    • /
    • 2003
  • The present study investigates the fire suppression characteristics using a water mist fire suppression system. Numerical simulations of fire suppression with water mist are performed with considering the interaction of fire plume and water droplet, droplet evaporation, and combustion of pool fire. The predicted temperature fields of smoke layer are compared with that of measured data. Numerical results agree with the experimental results within 5$^{\circ}C$ in the case without water mist In the case of fire suppression with water mist, numerical results dose not predict well lot temperature field in the gradual cooling region after water mist injection. But the predicted results of initial fire suppression are in good agreement with that of measured data. The reason of the discrepancy between predicted and measured data is due to the variation of turning rate during the injection of water mist. The effect of burning rate on the fire suppression is left as future study.

Compound Machining of Milling and Magnetic Abrasive Polishing for Free Form Surface (자유곡면의 밀링 자기연마 복합가공에 관한 연구)

  • Kwak, Tae-Kyung;Kim, Sang-Oh;Kwak, Jae-Seob
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.4
    • /
    • pp.455-461
    • /
    • 2010
  • Automated magnetic abrasive polishing which can be applied after machining of the mold on a machine tool without unloading is very effective for finishing a complicated injection mold surface. This study aims to realize one step polishing of free form surface with the same machine tool. For this purpose, magnetic flux density according to the change of curvature radii was simulated for selecting polishing conditions and experimental verification was performed with a complicated mold of aluminum alloy. As a result, it was seen by the simulation that the magnetic flux density at a gradual curvature of the mold was higher than at a steep curvature and the higher magnetic flux density produced the better surface roughness in the experimentation. The deviation for the surface roughness of the mold decreased on the whole and the uniform mold surface was obtained after the automated magnetic abrasive polishing.

Changes in Plasma Lipid Pattern in Streptozotocin-Induced Diabetic Rats: A Time Course Study (스트렙토토신-당뇨쥐의 유병기간에 따른 혈중지질패턴의 경시적 변화)

  • 이수자
    • Journal of Nutrition and Health
    • /
    • v.32 no.7
    • /
    • pp.767-774
    • /
    • 1999
  • This study was carrid out to examine a part of the mechanism for the etiology of diabetic complications. Thirty normal and forty streptozotocin(STZ)-induced diabetic rats were used as the animal models. Animals were sacrificed at the time points of 3 days, 1, 2, 4 and 6 weeks after STZ-injection and time course in body weight and organ weight, the levels of blood glucose, plasma lipid patterns, and atherogenic index were measured during 6 weeks. The STZ-diabetic animals showed 63% survival rate and fsting blood glucose levels of the diabetic animals measured in the range of 230-410mg/dL during the experimental period. The body weigh of diabetic animals decreased significantly throughout the experimental period and the relative weights of organs to body weight were significantly higher than the normal control ones. The enlargement of the kidney in the diabetic animals was especially remarkable. Plasma triglyceride concentration in diabetic rats substancially increased from the first week of onset of diabetes mellitus and maintained higher levels than the control ones throughout the whole experimental period. The plasma total cholesterol level and atherogenic index in the diabetic rats were significantly higher than the normal ones from the third day after STZ injection and showed a gradual increase with the duration of the disease. Throughout the experiment, the diabetic rats consistently showed a slightly lower HDL-cholesterol level compared to the normal animals. From the results of this study, it appears that the significant changes in blood lipid pattern in STZ-diabetic animals start from the first week after STZ injection.

  • PDF

SOLAR MICROWAVE BURSTS AND ELECTRON KINETICS

  • LEE JEONGWOO;BONG SU-CHAN;YUN HONG SIK
    • Journal of The Korean Astronomical Society
    • /
    • v.36 no.spc1
    • /
    • pp.63-73
    • /
    • 2003
  • Solar flares present a number of radiative characteristics indicative of kinetic processes of high energy particles. Proper understanding of the kinetic processes, however, relies on how well we can separate the acceleration from transport characteristics. In this paper, we discuss microwave and hard X-ray bursts as a powerful tool in investigating the acceleration and transport of high energy electrons. After a brief review of the studies devoted to the kinetic process of solar flare particles, we cast them into a simple formulation which allows us to handle the injection, trap, and precipitation of flare electrons self-consistently. The formulation is then taken as a basis for interpreting and analyzing a set of impulsive and gradual bursts occurred on 2001 April 6 observed with the Owens Valley Solar Array, and HXT/WBS onboard Yohkoh satellite. We quantify the acceleration, trap, and precipitation processes during each burst in terms of relevant time scales, and also determine ambient density and magnetic field. Our result suggests that it should be the acceleration property, in particular, electron pitch angle distribution, rather than the trap condition, that is mainly responsible for the distinctive properties of the impulsive and gradual flares.

Case Reports of Adipose-derived Stem Cell Therapy for Nasal Skin Necrosis after Filler Injection

  • Sung, Ha-Min;Suh, In-Suck;Lee, Hoon-Bum;Tak, Kyoung-Seok;Moon, Kyung-Min;Jung, Min-Su
    • Archives of Plastic Surgery
    • /
    • v.39 no.1
    • /
    • pp.51-54
    • /
    • 2012
  • With the gradual increase of cases using fillers, cases of patients treated by non-medical professionals or inexperienced physicians resulting in complications are also increasing. We herein report 2 patients who experienced acute complications after receiving filler injections and were successfully treated with adipose-derived stem cell (ADSCs) therapy. Case 1 was a 23-year-old female patient who received a filler (Restylane) injection in her forehead, glabella, and nose by a non-medical professional. The day after her injection, inflammation was observed with a $3{\times}3cm$ skin necrosis. Case 2 was a 30-year-old woman who received a filler injection of hyaluronic acid gel (Juvederm) on her nasal dorsum and tip at a private clinic. She developed erythema and swelling in the filler-injected area A solution containing ADSCs harvested from each patient's abdominal subcutaneous tissue was injected into the lesion at the subcutaneous and dermis levels. The wounds healed without additional treatment. With continuous follow-up, both patients experienced only fine linear scars 6 months postoperatively. By using adipose-derived stem cells, we successfully treated the acute complications of skin necrosis after the filler injection, resulting in much less scarring, and more satisfactory results were achieved not only in wound healing, but also in esthetics.

2-Dimensional Film Cooling Characteristics with the Height Variation of a Stepped Slot Exit (계단형 슬롯출구의 높낮이 변화에 따른 2차원 막냉각 특성)

  • Son, Chang-Ho;Kim, Tae-Mook;Lee, Geun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.46-54
    • /
    • 2005
  • Film cooling characteristics has been examined numerically for the height variation of a stepped slot exit. In this study, the upstream wall height of the stepped slot exit varies from -2d (d = slot width) to 3d, blowing ratio ranges from 0.5 to 3, and injection angles are $15^{\circ},\;30^{\circ},\;and\;45^{\circ}$. The results showed that film cooling performance was mainly subjected to the magnitude of recirculation region near the downstream-side slot exit as well as the magnitude and the distribution region of turbulent kinetic energy due to the local velocity and momentum differences between the coolant and the main flow near the slot exit. The up-1d type slot at higher blowing ratios over 2 and the flat type slot at lower blowing ratios below 1 have the best film cooling performances, in case of the injection angles of $30^{\circ},\;and\;45^{\circ}$, respectively. Compared with the other injection angles, in case of the injection angles of $15^{\circ}$, the best film cooling performances was shown in even a higher upstream wall (up-3d) at higher blowing ratio like 3 by the gradual reduction of the coolant velocity which minimizes the local velocity differences between the coolant and the main flow near the slot exit.