• Title/Summary/Keyword: Gradient of Electrode

Search Result 53, Processing Time 0.028 seconds

Characterization of Electrical Properties and Gating Effect of Single Wall Carbon Nanotube Field Effect Transistor

  • Heo, Jin-Hee;Kim, Kyo-Hyeok;Chung, Il-Sub
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.169-172
    • /
    • 2008
  • We attempted to fabricate carbon nanotube field effect transistor (CNT-FET) using single walled carbon nanotube(SWNT) on the heavily doped Si substrate used as a bottom gate, source and drain electrode were fabricated bye-beam lithography on the 500 nm thick $SiO_2$ gate dielectric layer. We investigated electrical and physical properties of this CNT-FET using Scanning Probe Microscope(SPM) and conventional method based on tungsten probe tip technique. The gate length of CNT-FET was 600 nm and the diameter of identified SWNT was about 4 nm. We could observed gating effect and typical p-MOS property from the obtained $V_G-I_{DS}$ curve. The threshold voltage of CNT-FET is about -4.6V and transconductance is 47 nS. In the physical aspect, we could identified SWNT with phase mode of SPM which detecting phase shift by force gradient between cantilever tip and sample surface.

Effects of a Flow Guide on the Arcing History in a Thermal Puffer Plasma Chamber (유동 가이드가 열파퍼 플라즈마 챔버의 아크현상 이력에 미치는 영향)

  • Lee, Jong-Chul;Kim, Youn-Jea
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.10
    • /
    • pp.832-839
    • /
    • 2007
  • The geometry and dimensions of an expansion chamber are decisive factors in thermal puffer plasma chamber designs. Because they together dominate the temperature and speed at which the cooling gas from the chamber flows back through a flow channel to the arcing zone for the successful interruption of fault currents. In this study, we calculated the flow and mass transfer driven by arc plasma, and investigated the effects of a flow guide installed inside a thermal puffer plasma chamber. It is found that the existing cold gas of the chamber mixes with hot gases entrained from the arcing zone and is subjected to compression due to pressure build-up in the chamber. The pressure build-up with the flow guide is larger than that without due to a vortex which rotates clockwise around the chamber center. By the reverse pressure gradient, the mixing gas of the chamber flows back out for cooling down the residual plasma near current zero. In the case with the flow guide, the temperature just before current zero is lower than that without, and the Cu concentration with high electrical conductivity is also less than that without the flow guide.

Effects of an Electric Field on the Dynamic Characteristics of Bubbles in Nucleate Boiling (핵비등에서 기포의 동특성에 대한 전기장의 효과)

  • 권영철;장근선;권정태;김무환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.963-971
    • /
    • 2000
  • In order to investigate the effects of an electric field on EHD(Electro-hydrodynamic) nucleate boiling hat transfer characteristics in a nonuniform electric field under saturated pool boiling, the basic study has been performed experimentally. In the present study, the working fluid is R-113 and the plate-wire electrode system is used to generate a steep electric field gradient. Boiling parameters are investigated by using a high speed camera. The electric field distribution around a wire is obtained to understand the effect of an electric field on bubble departure/movement. The experimental results show EHD effects are much more considerable when the applied voltage increases. Bubbles depart away from the heated wire in radial direction. It is confirmed that the mechanisms of EHD nucleate boiling are closely connected with the dynamic behavior of bubbles. The boiling parameters are significantly changed by the electric field strength. With increasing applied voltages, the bubble size decreases and the nucleation site density, bubble velocity and bubble frequency increase.

  • PDF

Multi-Layered Sintered Porous Transport Layers in Alkaline Water Electrolysis (다층 소결메쉬 확산체를 이용한 알칼라인 수전해 셀)

  • YEOM, SANG HO;YUN, YOUNG HWA;CHOI, SEUNGWOOK;KWON, JIHEE;LEE, SECHAN;LEE, JAE HUN;LEE, CHANGSOO;KIM, MINJOONG;KIM, SANG-KYUNG;UM, SUKKEE;KIM, CHANG-HEE;CHO, WON CHUL;CHO, HYUN-SEOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.6
    • /
    • pp.442-454
    • /
    • 2021
  • The porous transport layer (PTL) is essential to effectively remove oxygen and hydrogen gas from the electrode surface at high current density operation conditions. In this study, the effect of PTL with different characteristics such as pore size, pore gradient, interfacial coating was investigated by multi-layered sintered mesh. A water electrolysis single cell of active area of the 34.56 cm2 was constructed, and IV performance and impedance analysis were conducted in the range of 0 to 2.0 A/cm2. It was confirmed that the multi-layered sintered mesh PTL, which have an average pore size of 25 to 57 ㎛ and a larger pore gradient, removed bubbles effectively and thus seemed to improve IV performance. Also, it was confirmed that the catalytic metals such as Ni, NiMo coating on the PTL reduced activation overpotential, but increased mass transport overpotential.

Biological Dechlorination of Chlorinated Ethylenes by Using Bioelectrochemical System (생물전기화학시스템을 이용한 염화에틸렌의 생물학적 탈염소화)

  • Yu, Jaecheul;Park, Younghyun;Seon, Jiyun;Hong, Seongsuk;Cho, Sunja;Lee, Taeho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.304-311
    • /
    • 2012
  • Chlorinated ethylenes such as perchloroethylene (PCE) and trichloroethylene (TCE) are widely used as industrial solvents and degreasing agents. Because of improper handling, these highly toxic chlorinated ethylenes have been often detected from contaminated soils and groundwater. Biological PCE dechlorination activities were tested in bacterial cultures inoculated with 10 different environmental samples from sediments, sludges, soils, and groundwater. Of these, the sediment using culture (SE 2) was selected and used for establishing an efficient PCE dechlorinating enrichment culture since it showed the highest activity of dechlorination. The cathode chamber of bioelectrochemical system (BES) was inoculated with the enrichment culture and the system with a cathode polarized at -500 mV (Vs Ag/AgCl) was operated under fed-batch mode. PCE was dechlorinated to ethylene via TCE, cis-dichloroethylene, and vinyl chloride. Microbial community analysis with polymerase chain reaction-denaturing gradient gel electrophoresis (PCR-DGGE) showed that the microbial community in the enrichment culture was significantly changed during the bio-electrochemical PCE dechlorination in the BES. The communities of suspended-growth bacteria and attached-growth bacteria on the cathode surface are also quite different from each other, indicating that there were some differences in their mechanisms receiving electrons from electrode for PCE dechlorination. Further detailed research to investigate electron transfer mechanism would make the bioelctrochemical dechlorination technique greatly useful for bioremediation of soil and groundwater contaminated with chlorinated ethylenes.

Gastroesophageal Reflux in Mechanically Ventilated Preterm Infants (기계적 환기 요법이 미숙아 위식도 역류에 미치는 영향)

  • Ku, Hye Jin;Park, Su Eun;Park, Jae Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.1
    • /
    • pp.48-53
    • /
    • 2004
  • Purpose: Besides interferencence of esophageal motor function by the nasogastric tube, a decline of the positive gastro-esophageal pressure gradient caused by intermittent positive pressure ventilation seems to have a major role in the pathogenesis of gastroesophageal reflux (GER) in mechanically ventilated preterm infants. The aim of this study was to determine the incidence of GER and associated risk factors in mechanically ventilated preterm infants. Methods: Twenty four hour esophageal pH monitorings were performed using a antimony electrode on 11 mechanically ventilated preterm infants in Neonatal Intensive Care Unit in Pusan National University Hospital. We evaluated the following reflux parameters; reflux index, reflux episodes/hour, reflux episodes ${\geq}5min/hour$, duration of longest episode, and percent episodes ${\geq}5min$. Patients were considered to have significant GER if more than 2 among 5 parameters were satisfied. Results: The mean gestational age of the patients was 30.9 weeks, mean birth weight was 1,568 g, and mean age at the time of pH monitoring was 2.8 days. Significant GER was detected in 4 patients (36.4%). There was no relationship between the incidence of GER and gestational age, birth weight, postnatal age, or the ventilator settings. Conclusion: The incidence of GER in mechanically ventilated preterm infants was similar, compared with other previous studies. Associated risk factors of GER in these patients were not detected. Therefore, mechanical ventilation in preterm infants does not seem to be the high risk factor of GER.

  • PDF

A Study on the Influence Coaxial Parallel Magnetic Field upon Plasma Jet (II) (Plasma Jet의 동축평행자계에 의한 영향에 관한 연구 2)

  • Choon Saing Jhoun
    • 전기의세계
    • /
    • v.22 no.5
    • /
    • pp.19-32
    • /
    • 1973
  • This paper treats with some of plasma jet behaviors under magnetic field for the purpose of controlling important characteristics of plasma jet in the practices of material manufacturings. Under the existence and non-existence of magnetic field, the pressure distribution, flame length, stability and noise of plasma jet are comparatively evaluated in respect of such parameters as are current, gap of electrode, quantity of argon flow, magnetic flux density, diameter and length of nozzle. The results are as follows: 1) the pressure, the length and the noise of plasma jet rise gradually with the increase of are current, and have high values under identical arc current as the diameter of nozzle increases, but reverse phenomenon tends to appear in the noise. 2) The pressure, the flame length and the noise increase with the increased quantity of argon flow, and the rising slope of noise is particularly steep. Under magnetic field, the quantity of argon flow in respect of flame length has the critical value of 80(cfh). 3) The pressure and length of flame decrease with small gradient value as the length of gap increases, but the noise tends to grow according to the increase of nozzle diameter. 4) The pressure and the length of jet flame decrease inversly with the increase of magnetic flux density, which have one critical value in the 100 amps of arc current and two values in 50 amps. The pressure of jet flame can be below atomospher pressure in strong magnetic field. 5) "The constriction length of nozzle has respectively the critical value of 6(mm) for pressure and 23(mm) for the length of flame. 6) Fluctuations in the wave form of voltage become greater with the increase of argon flow and magnetic flux density, but tends to decrease as arc current increases, having the frequency range of 3-8KHz. The wave form of noise changes almost in parallel with that of voltage and its changing value increases with argon flow, arc current and magnetic flux density, having the freuqency range of 6-8KHz. The fluctuation of jet presurre is reduced with the increase of argon flow and magnetic flux density and grows with arc current.rent.

  • PDF

The Change of Lower-limb Muscle Activity according to Gait speed when Normal and Assistive Gait of older (노인의 정상 보행과 보행보조기를 사용한 보행 시 속도변화에 따른 하지 근 활성도 변화)

  • Kim, Byung-Kon;Kim, Tae-Ho
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.60-67
    • /
    • 2008
  • Purpose : The purpose of this study is to investigate that the change of lower-limb muscle activity when normal gait and assistive gait of older. Methods : The selected subjects of this study were 11 older who be in good physical health and have not problem to gait and over 60 age to analyze the muscle activity. This study has been conducted to analyze the muscle activity of normal gait and assistive gait in unitary status without any contrast group. We have them gait condition of a gradient of 0% and velocity of 1km/h, 2km/h, 3km/h electrode were attached to the motor point of Rectus femoris, Hamstrings, Tibialis anterior, Calf muscle. When normal gait and assistive gait performs, there are meaningful differences that the muscle activity takes a small drop in Rectus femoris by 9.17% at 1km/h, 9.79% at 2km/h, 13.80% at 3km/h, hamstring by 14.78% at 1km/h, 17.82% at 2km/h, 17.26% at 3km/h, Tibialis anterior by 24.38% at 1km/h, 23.85% at 2km/h, 33.52% at 3km/h, Calf muscle by 13.68% at 1km/h, 16.70% at 2km/h, 18.37% at 3km/h(p<0.05). Results : They show the significant difference in statistical figure. We've received the significant through the comparison between normal gait and assistive gait. These results will be utilized for the preliminary date in the future.

  • PDF

Characterization of Dielectrophoretic Force for the Structural Shapes of Window in Microfluidic Dielectrophoretic Chip (미세유체칩내 electrode의 opening window형태에 따른 유전전기영동력 특성 규명)

  • Lee, Jaewoo;Kwak, Tae Joon;Yoon, Dae Sung;Lee, Sang Woo
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.4
    • /
    • pp.189-196
    • /
    • 2013
  • Dielectrophoresis(DEP) is useful in manipulation and separation of micro-sized particles including biological samples such as bacteria, blood cells, and cancer cells in a micro-fluidic device. Especially, those separation and manipulation techniques using DEP in combination of micro fabrication technique have been researched more and more. Recently, it is revealed that a window structure of insulating layer in microfluidic DEP chip is key role in trap of micro-particles around the window structure. However, the trap phenomenon-driven by DEP force gradient did not fully understand and is still illusive. In this study, we characterize the trap mechanism and efficiency with different shapes of window in a microfluidic DEP chip. To do this characterization, we fabricated 4 different windows shapes such as rhombus, circle, squares, and hexagon inside a micro-fluidic chip, and performed micro-sized particles manipulation experiments as varying the frequency and voltage of AC signal. Moreover, the numerical simulation with the same parameters that were used in the experiment was also performed in order to compare the simulation results and the experimental results. Those comparison shows that both results are closely matched. This study may be helpful in design and development of microfluidic DEP chip for trapping micro-scaled biological particle.

Microbial Enrichment and Community Analysis for Bioelectrochemical Acetate Production from Carbon Dioxide (이산화탄소로부터 생물전기화학적 아세트산 생산을 위한 미생물 농화배양 및 군집 분석)

  • Kim, Junhyung;Kim, Young-Eun;Park, Myeonghwa;Song, Young Eun;Seol, Eunhee;Kim, Jung Rae;Oh, You-Kwan
    • New & Renewable Energy
    • /
    • v.16 no.1
    • /
    • pp.58-67
    • /
    • 2020
  • Microbial electrosynthesis has recently been considered a potentially sustainable biotechnology for converting carbon dioxide (CO2) into valuable biochemicals. In this study, bioelectrochemical acetate production from CO2 was studied in an H-type two-chambered reactor system with an anaerobic microbial consortium. Metal-rich mud flat was used as the inoculum and incubated electrochemically for 90 days under a cathode potential of -1.1 V (vs. Ag/AgCl). Four consecutive batch cultivations resulted in a high acetate concentration and productivity of 93 mmol/L and 7.35 mmol/L/day, respectively. The maximal coulombic efficiency (rate of recovered acetate from supplied electrons) was estimated to be 64%. Cyclic voltammetry showed a characteristic reduction peak at -0.2~-0.4 V, implying reductive acetate generation on the cathode electrode. Furthermore, several electroactive acetate-producing microorganisms were identified based on denaturing- gradient-gel-electrophoresis (DGGE) and 16S rRNA sequence analyses. These results suggest that the mud flat can be used effectively as a microbial source for bioelectrochemical CO2 conversion.