• 제목/요약/키워드: Gradient echo image

검색결과 65건 처리시간 0.027초

Added Value of Chemical Exchange-Dependent Saturation Transfer MRI for the Diagnosis of Dementia

  • Jang-Hoon Oh;Bo Guem Choi;Hak Young Rhee;Jin San Lee;Kyung Mi Lee;Soonchan Park;Ah Rang Cho;Chang-Woo Ryu;Key Chung Park;Eui Jong Kim;Geon-Ho Jahng
    • Korean Journal of Radiology
    • /
    • 제22권5호
    • /
    • pp.770-781
    • /
    • 2021
  • Objective: Chemical exchange-dependent saturation transfer (CEST) MRI is sensitive for detecting solid-like proteins and may detect changes in the levels of mobile proteins and peptides in tissues. The objective of this study was to evaluate the characteristics of chemical exchange proton pools using the CEST MRI technique in patients with dementia. Materials and Methods: Our institutional review board approved this cross-sectional prospective study and informed consent was obtained from all participants. This study included 41 subjects (19 with dementia and 22 without dementia). Complete CEST data of the brain were obtained using a three-dimensional gradient and spin-echo sequence to map CEST indices, such as amide, amine, hydroxyl, and magnetization transfer ratio asymmetry (MTRasym) values, using six-pool Lorentzian fitting. Statistical analyses of CEST indices were performed to evaluate group comparisons, their correlations with gray matter volume (GMV) and Mini-Mental State Examination (MMSE) scores, and receiver operating characteristic (ROC) curves. Results: Amine signals (0.029 for non-dementia, 0.046 for dementia, p = 0.011 at hippocampus) and MTRasym values at 3 ppm (0.748 for non-dementia, 1.138 for dementia, p = 0.022 at hippocampus), and 3.5 ppm (0.463 for non-dementia, 0.875 for dementia, p = 0.029 at hippocampus) were significantly higher in the dementia group than in the non-dementia group. Most CEST indices were not significantly correlated with GMV; however, except amide, most indices were significantly correlated with the MMSE scores. The classification power of most CEST indices was lower than that of GMV but adding one of the CEST indices in GMV improved the classification between the subject groups. The largest improvement was seen in the MTRasym values at 2 ppm in the anterior cingulate (area under the ROC curve = 0.981), with a sensitivity of 100 and a specificity of 90.91. Conclusion: CEST MRI potentially allows noninvasive image alterations in the Alzheimer's disease brain without injecting isotopes for monitoring different disease states and may provide a new imaging biomarker in the future.

신경계 질환에 관한 정확한 진단을 위해 다양한 보완 정보를 제공하는 독특한 영상 기법으로서의 자기화율 강조 영상 (Susceptibility-Weighted Imaging as a Distinctive Imaging Technique for Providing Complementary Information for Precise Diagnosis of Neurologic Disorder)

  • 전병욱;유인규;김태건;김하연;황승배
    • 대한영상의학회지
    • /
    • 제82권1호
    • /
    • pp.99-115
    • /
    • 2021
  • 자기공명영상 기술의 개발에 따라 다양한 종류의 시퀀스가 개발되어 방사선 진단에 큰 도움이 되었다. 다양한 자기공명영상 시퀀스 중에서 자기화율 강조 영상은 고 공간 분해능 3차원 경사 에코 시퀀스를 발전시킨 것으로 국소 자기장 왜곡에 의한 디옥시헤모글로빈, 페리틴, 헤모시데린 및 골, 광물 검출에 매우 민감하다. 이러한 영상 특징으로 인해 자기화율 강조 영상은 다양한 신경 장애의 진단과 치료에 사용되어 왔으며, 영상 화질이 향상되어 방사선 전문의에게 보다 유용한 정보를 제공할 수 있게 되었다. 다양한 신경 장애에서 발생할 수 있는 자기화율 강조 영상에 나타날 수 있는 다양한 신호의 원리를 설명하고, 독특한 영상의학적 특징을 가진 질환 혹은 물질에 대해 임상적 또는 병리학적으로 진단된 환자들에 관하여 각각의 질병에 맞추어 조사하였다. 또한 자기화율 강조 영상에서 각각의 신경 장애에서 보일 수 있는 영상의학적 특징에 대해 질환의 전반적인 정보를 함께 요약하여 정리하였다. 뇌 실질 및 주변 조직에 생기는 다양한 신경계 질환들은 자기화율 강조 영상에서 뚜렷하게 구분되는 다양한 영상학적 특징을 보인다. 이에 의해 자기화율 강조 영상은 다양한 보조적 정보를 통해 적절한 진단에 도움을 준다.

Optimization of the Flip Angle and Scan Timing in Hepatobiliary Phase Imaging Using T1-Weighted, CAIPIRINHA GRE Imaging

  • Kim, Jeongjae;Kim, Bong Soo;Lee, Jeong Sub;Woo, Seung Tae;Choi, Guk Myung;Kim, Seung Hyoung;Lee, Ho Kyu;Lee, Mu Sook;Lee, Kyung Ryeol;Park, Joon Hyuk
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권1호
    • /
    • pp.1-9
    • /
    • 2018
  • Purpose: This study was designed to optimize the flip angle (FA) and scan timing of the hepatobiliary phase (HBP) using the 3D T1-weighted, gradient-echo (GRE) imaging with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique on gadoxetic acid-enhanced 3T liver MR imaging. Materials and Methods: Sixty-two patients who underwent gadoxetic acid-enhanced 3T liver MR imaging were included in this study. Four 3D T1-weighted GRE imaging studies using the CAIPIRINHA technique and FAs of $9^{\circ}$ and $13^{\circ}$ were acquired during HBP at 15 and 20 min after intravenous injection of gadoxetic acid. Two abdominal radiologists, who were blinded to the FA and the timing of image acquisition, assessed the sharpness of liver edge, hepatic vessel clarity, lesion conspicuity, artifact severity, and overall image quality using a five-point scale. Quantitative analysis was performed by another radiologist to estimate the relative liver enhancement (RLE) and the signal-to-noise ratio (SNR). Statistical analyses were performed using the Wilcoxon signed rank test and one-way analysis of variance. Results: The scores of the HBP with an FA of $13^{\circ}$ during the same delayed time were significantly higher than those of the HBP with an FA of $9^{\circ}$ in all the assessment items (P < 0.01). In terms of the delay time, images at the same FA obtained with a 20-min-HBP showed better quality than those obtained with a 15-min-HBP. There was no significant difference in qualitative scores between the 20-min-HBP and the 15-min-HBP images in the non-liver cirrhosis (LC) group except for the hepatic vessel clarity score with $9^{\circ}$ FA. In the quantitative analysis, a statistically significant difference was found in the degree of RLE in the four HBP images (P = 0.012). However, in the subgroup analysis, no significant difference in RLE was found in the four HBP images in either the LC or the non-LC groups. The SNR did not differ significantly in the four HBP images. In the subgroup analysis, 20-min-HBP imaging with a $13^{\circ}$ FA showed the highest SNR value in the LC-group, whereas 15-min-HBP imaging with a $13^{\circ}$ FA showed the best value of SNR in the non-LC group. Conclusion: The use of a moderately high FA improves the image quality and lesion conspicuity on 3D, T1-weighted GRE imaging using the CAIPIRINHA technique on gadoxetic acid, 3T liver MR imaging. In patients with normal liver function, the 15-min-HBP with a $13^{\circ}$ FA represents a feasible option without a significant decrease in image quality.

Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구 (Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm)

  • ;김태형;천송이;한용희;최기승;이광식;전재량;은충기;문치웅
    • Investigative Magnetic Resonance Imaging
    • /
    • 제12권2호
    • /
    • pp.131-141
    • /
    • 2008
  • 목적: 물체 내부의 온도를 비침습적으로 측정할 수 있는 양성자 공명 주파수 이동에 의한 MR 온도영상의 재구성에 center array-sequencing 위상펼침(PU) 기법을 적용시켜 그 성능 및 유용성을 평가하고자 하였다. 대상 및 방법: MR 온도 영상에 앞서 잡음 수준이 다른 타원형 팬텀들을 컴퓨터 모의 실험으로 제작하고 제안된 PU방 법을 적용시켜 잡음에 대한 성능을 평가하였다. MR 실험은 PU 실험과 이를 이용한 온도분포영상획득 실험으로 구분하여 수행되었다. 1.5T MR 영상장치에서 무릎코일과 $T2^*$ 경사자장에코 펄스열을 이용하여 MR 영상을 얻었다. 물통, 오렌지, 아가젤 등의 팬텀을 실험 대상으로 하였고 자체 제작된 온수펌프 장치로 팬텀의 온도를 조절하였다. T 형 열전쌍 온도측정장치로 팬텀 온도를 측정하고 MR 온도영상 결과와 비교하였다. 획득된 MR영상의 위상분포는 제안된 PU방법으로 위상을 편 후 온도분포 영상을 재구성하였다. 가열 전 후의 온도변화와 MR 영상의 위상변화 관계를 이용하여 아가젤 팬텀 내의 MR온도분포 영상을 구하였다. 결과: 제안된 center array-sequencing PU 알고리즘을 이용하여 여러 팬텀에 대한 MR 위상영상의 접힘 현상을 기존 방법보다 간편하고 빠르게 제거할 수 있었고 이를 이용하여 MR 온도영상을 획득할 수 있었다. 결론: 본 연구는 제안된 center array-sequencing 위상펼침 방법이 잡음에 강하고 처리 속도가 빠를 뿐만 아니라 양성자 공명 주파수 이동의 성질을 이용한 MR 온도 영상 획득에 성공적으로 적용될 수 있음을 보였다.

  • PDF

Keyhole 방법을 이용한 MR 온도감시영상의 시간해상도 향상기법 (Time Resolution Improvement of MRI Temperature Monitoring Using Keyhole Method)

  • 한용희;김태형;천송이;김동혁;이광식;은충기;전재량;문치웅
    • Investigative Magnetic Resonance Imaging
    • /
    • 제13권1호
    • /
    • pp.31-39
    • /
    • 2009
  • 목적 : 본 연구는 PRF(Proton Resonance Frequency)를 이용한 MR 온도감시 영상에서 시간 해상도를 keyhole방법 적용으로 향상시키고자하였다. 제시된 keyhole방법과 기존 온도영상 방법 사이의 비교를 위해 온도 값에 대한 RMS(Root Mean Square) 오차와 SNR(Signal to Noise Ratio)을 비교하였다. 대상 및 방법 : PRF 방법과 GRE(Gradient Recalled Echo)를 이용하여 MR 온도영상을 구현하였으며 장비로는 임상용 1.5T MRI 장치를 이용하였다. 인체모사 조직인 2% 한천 젤 팬텀과 돼지 근육조직으로 실험을 수행하였다. 2.45GHz대역의 마이크로파 발생장치로 MR호환 동축 슬롯 안테나를 구동하여 MRI장치 내에서 대상 조직과 팬텀을 5분간 가열하였다. 가열 직후 10분 동안에 순차적으로 MR 원 데이터를 획득하였다. 획득된 원 데이터는 PC로 전송되어 전체 위상을 부호화하여 얻은 원 데이터의 바깥영역과 K-space의 중앙 영역을 각각 128, 64, 32, 16으로 위상부호화된 데이터로 keyhole영상을 재구성하였다. 256개로 전체 부호화된 자체-참조 온도영상과 RMS 오차를 비교하였으며, zero-filling 영상과 SNR비교를 하였다. 결과 : keyhole 온도 영상에서 위상부호화 수가 128, 64, 32, 16으로 줄어들수록 RMS 오차로 산출한 온도의 차이가 0.538, 0.712, 0.786, 0.845$^{\circ}C$ 만큼 증가하였으나 SNR 값은 keyhole의 위상부호화 수가 줄어도 유지되었다. 결론 : 본 연구는 고정된 매트릭스 크기에 keyhole 방법 적용을 이용하여 온도 감시에서의 시간해상도 증가와 SNR 값을 유지하는 결과를 도출하여 성공적인 적용을 보여 주었다. 본 연구를 기반으로 한 다음 연구에서는 최적화된 변수를 이용한 keyhole 방법 적용으로 최소 온도 오차의 실시간 MR 온도 감시가 가능할 것이라 예상된다.

  • PDF