• Title/Summary/Keyword: Governor control

Search Result 151, Processing Time 0.023 seconds

A Comparison and Evaluation of New Regulation on People Credit Funds Rating in Vietnam

  • Dang, Thu Thuy
    • Asian Journal of Business Environment
    • /
    • v.8 no.1
    • /
    • pp.23-29
    • /
    • 2018
  • Purpose - The purpose of this research is to make a comparative assessment of People Credit Funds (PCFs) ranking in Vietnam between the Circular No. 42/2016/TT-NHNN dated December 20, 2016 with the Decision No. 14/2007/QD-NHNN dated 09/4/2007 issued by the Governor of the State Bank. Research design, data, and methodology - This study is mainly based on the Circular No. 42/2016/TT-NHNN dated December 20, 2016 and the Decision No. 14/2007/QD-NHNN dated 09/4/2007 issued by the Governor of the State Bank on PCFs ranking. Results - The study paper has shown positive changes in PCFs ranking in Vietnam in accordance with the Circular No. 42/2016/TT-NHNN, such as increasing Capital Adequacy Ratio (CAR), maintaining CAR, improving assets quality, developing indicators of governance, management and control capability. These changes have implications for the development and efficient performance of PCFs in Vietnam. Conclusions - The classification and evaluation of PCFs will contribute to its healthy development. These finding support PCFs to understand more about rating methodology, significance of rating system and the importance of improving their rating. PCFs in Vietnam desire to develop their business effectively, they need to understand exactly and comply fully with regulations related to their field of operations.

Feasibility Study for Application of Frequency Regulation ESS in Cuba: Technological Effects on Improving Frequency Compensation (쿠바 주파수조정 ESS 운영 전략 검토: 주파수 보상 효과 분석)

  • Kim, Soo-Yeol;Lee, Seong-eun;Kim, Jin-tae
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.123-127
    • /
    • 2020
  • KEPCO has installed Frequency Regulation ESS (FR ESS) of 376 MW since 2015. Frequency Regulation is ancillary service to support stabilizing system frequency, which is divided into governor free and automatic generation control. KEPCO operates FR ESS as governor free application and leads FR ESS market with capability of diverse demonstration and operation experiences. To expand FR ESS role during transient states of power system, KEPCO has extended operating time of charging and discharging. KEPCO has also changed speed droop lower than before to improve contribution on frequency compensation, and acquired much experiences of differentiating bad cells from others. Based on these technologies and know-hows, KEPCO Research Institutes received request of feasibility study and technical cooperation for overseas FR ESS business. This paper suggests the simple and practical method for making technological feasibility study of FR ESS.

A simulation module to practice hydraulic mechanical governors and its adjustment characteristics for stability (유압기계식 거버너의 실습용 시뮬레이션 모듈과 안정도의 조정 특성)

  • Choi, Soon-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.533-540
    • /
    • 2013
  • Prime movers in engine rooms inherently are much affected by the adjustment of their governors for the steady state and transient properties, consequently requiring that marine engineers shall be well familiar with the way to manage governor dials for normal operation. The hydro-mechanical governors basically have different control characteristics and adjustment parameters of stability from digital governors. The former include compensation mechanism using dash pot while the control algorithm of the latter is usually based on the PID action. This study is for configuring a simulation module to let trainees practice how to adjust dials for stability on hydraulic governors in the view that the practice by real governors and engines is time consuming and high cost for operation. The governor module includes the adjusting points such as speed set, speed droop, needle valve and compensation pointer with engine module of $2^{nd}$ order coupled. The results of simulation showed satisfactory responses as a training tool for the adjustment of control parameters.

Permanent magnet excitation generator Voltage fluctuation suppression control method (영구자석 여자기형 발전기의 전압변동 억제 제어방식)

  • Jo, YeongJun;Kwak, YunChang;Lee, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.74-75
    • /
    • 2017
  • This paper proposes a control scheme of the voltage ripple suppression for the permanent magnet exciter generator. The output voltage of the permanent magnet excitation generator is affected by the field current, load current and the engine speed. The engine speed can be controlled by the governor. But, the actual frequency is changed at the starting and a sudden load variation. As a result, output voltage overshoot and undershoot can decrease the power quality in the grid system. The proposed control scheme uses a frequency factor to control the field current of the generator for the voltage ripple reduction. Because of the linkage flux is proportional to the frequency, the instantaneous frequency can consider the linkage flux. The proposed control method shows the improved control performance for the permanent magnet excitation generator through simulation.

  • PDF

A method of constructing fuzzy control rules for electric power systems

  • Ueda, Tomoyuki;Ishigame, Atsushi;Kawamoto, Shunji;Taniguchi, Tsuneo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1371-1376
    • /
    • 1990
  • The paper presents a method of constructing simple fuzzy control rules for the determination of stabilizing signals of automatic voltage regulator and governor, which are controllers of electric power systems. Fuzzy control rules are simplified by considering a coordinate transformation with the rotation angle .theta. on the phase plane, and by expanding the range of membership functions. Also, two rotation angles .theta. $_{1}$ and .theta. $_{2}$ are selected for the linearizable region and the nonlinear one of the system, respectively. Here, .theta. $_{1}$ is chosen by the pole assignment method, and .theta. $_{2}$ by a performance index. Fuzzy inference is applied to the connection of two rotation angles .theta. $_{1}$ and .theta. $_{1}$ by regarding the distance from the desired equilibrium point as a variable of condition parts. The control effect is demonstrated by an application of the proposed method to one-machine infinite-bus power system.

  • PDF

Steam Generator Modeling for CANDU Transient Simulation (CANDU 시뮬레이션을 위한 증기발생기 모델링)

  • Seung, Seo-Jae;Cheon, Im-Jae;Park, Ji-Won;Sik, Jeong-U
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.05a
    • /
    • pp.138-143
    • /
    • 1994
  • A simplified steam generator model has been developed for the simulation of the operational transients of CANDU nuclear power plant. For the analysis of the secondary side, a control volume approach is used and the flow conservation equations are applied for each control volume. The typical steam generator control logic such as the level control and the pressure control are incorporated into the steam generator model with appropriate interface conditions. The steam line including ASDV, CSDV, and governor valve also has been modeled. Test results for typical operational transient case show reasonable transient behavior of steam generator in a real time basis, which is promising for a CANDU engineering simulator.

  • PDF

A Study on Tuning Method of Turbine Speed Controller Using Fuzzy Inference (퍼지추론을 이용한 수차 속도제어기 동조기법에 관한 연구)

  • Lee, J.H.;Kim, W.H.;Paik, D.H.;Sung, K.M.;Shin, G.W.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.316-318
    • /
    • 1993
  • In order to estimation the optimum PID parameter of the turbine speed controller, the response cure of the object plant was compared with the reference pattern and then the magnitude peak value error and peak time error was calculated. With the calculated errors as input into the Fuzzy inference Method was introduced to propose the tuning method for each parameter. And the computer simulation was performed with the above Fuzzy inference method in which the Chunju hydro power plant turbine governor system was used as a model. This Study also aims to develop the exclusive tuner for govenor using industrial computer.

  • PDF

Development of automatic backup systems for turbine speed signal (터빈 속도신호의 자동백업 시스템 개발)

  • Kim, Kwan-Haeng;Kim, Ho-Chan
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.844-846
    • /
    • 1999
  • A speed signal of governor, which control the output and speed of a generator, is important because a signal failure can be causing the shutdown of a power plant. thus, it is necessary to introduce switching method with two complementary signal. This paper presents a comparative study of speed signal switching methods. One of the Proposed methods has been tested at a power plant in Pukcheju and the approach described here is expected to be of wide applicability.

  • PDF

A study on characteristic of servovalve control for steam turbine governor (증기터빈 조속기용 서보밸브 제어특성에 대한 연구)

  • Kim, Byoung-Chul;Kim, Jong-An;Woo, Joo-Hee;Choi, In-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2263-2265
    • /
    • 2004
  • 발전소 증기터빈 밸브제어의 핵심을 이루고 있는 서보밸브 제어특성을 파악하고, 조속기 개조에 필요한 제어루프 구성방법 및 각종 제어상수를 시험을 통해 미리 파악하여 교체 적응 시에 발생될 문제점을 해결하고자 시험한 내용을 서술하고자 한다.

  • PDF