• 제목/요약/키워드: Goniometer

검색결과 252건 처리시간 0.022초

엉덩관절 수술 환자에서 스마트폰을 이용한 관절가동범위 측정의 신뢰도 및 타당도 연구 (The Reliability and Validity of Hip Range of Motion Measurement using a Smart phone Operative Patient)

  • 박선욱;김명수;배효선;차용호
    • 대한물리의학회지
    • /
    • 제10권2호
    • /
    • pp.1-7
    • /
    • 2015
  • PURPOSE: The aims of this study were to assess the intra-tester and inter-tester reliability and validity of hip range of motion using a smart phone in hip operative patients. METHODS: Twenty-five patients (eight total hip arthroplasty and seventeen femur neck fracture) participated in this study. The range of motions in active and passive hip flexion, abduction and external rotation were measured with a goniometer and smart phone over two times by two observers. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC2,1). The validity was measured by Pearson's correlation coefficient RESULTS: The intra-observer reliability was good in all measured items (ICC>0.78). The inter-observer reliability was high with ICC (>0.90). All correlation coefficients of smart phone and goniometer was greater than 0.85 and showed a significant positive correlation (p<0.01). CONCLUSION: The range of motion measurement with a smart phone showed acceptable reliability. Therefore, it could be convenient and have economical benefits to measure the range of motion of the hip joint using a smart phone.

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • 한국결정학회:학술대회논문집
    • /
    • 한국결정학회 2002년도 정기총회 및 추계학술연구발표회
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

한국인 20대 청년의 팔 관절 동작범위 측정 연구 (A Study of Measurement on Range of Arm Joint Motion of Korean Male in Twenties)

  • 이영신;이석기;박세진;김철중
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1995년도 춘계학술대회논문집
    • /
    • pp.62-71
    • /
    • 1995
  • This paper measured the range of arm joint motion for Korean 54 male in twenties. The subjects are measured directly using Goniometer and angle gauge. The static measurement variables are seven and the dynamic measurement variables are thirteen. The anthropometric datum are analyzed by basic statistical analysis, correlation analysis and regression analysis using commercial SAS program. The results of analysis are compared with American students anthropometric data by Laubach, 1978.

  • PDF

세탁기의 사용자 인터페이스에 대한 노인의 사용편의성 평가 및 디자인 개선에 관한 연구 (Old People′s Usability Testing and Design for the User Interface of Washing Machine)

  • 정광태;송복희
    • 디자인학연구
    • /
    • 제16권2호
    • /
    • pp.49-56
    • /
    • 2003
  • 노인들도 사용하기 편한 제품을 디자인하기 위해서는 기존 제품에 대한 노인들을 대상으로 한 실험과정을 통하여 불편한 점을 파악하고, 그러한 불편요소가 해소될 수 있는 방향으로 해당제품이 디자인되어야 한다. 이러한 필요성에 의하여, 본 연구에서는 노인들의 일상생활에서 가장 자주 사용하고 일반적인 제품인 세탁기를 대상으로 디자인과정과 평가과정에 대한 연구를 수행하였다. 특히, 측각기와 같은 인간공학 장비를 사용하여 제품의 특정 부분에 대한 조작 편의성 평가를 수행할 수 있는 방법과 그 결과를 디자인에서 어떻게 활용할 수 있는지도 제시 하였다. 또한, 인간공학적 측면에서의 이론과 실험을 통한 디자인 방향과 컨셉의 결정, 디자인안 개발, 디자인안의 평가를 위한 실험, 실제 모델 제작, 사용편의성 측면에서 기존 모델과의 비교평가를 위한 실험 등에 대한 과정이 설명되었다. 연구의 결과는 노인을 위한 세탁기 개발에서의 중요 자료로 활용될 수 있고, 적용된 방법론은 세탁기 뿐만 아니라 다른 가전제품의 노인을 위한 디자인 개발에서도 활용될 수 있을 것이다.

  • PDF

에폭시/폴리우레탄 블렌드 시스템의 표면 자유에너지 변화가 기계적 특성에 미치는 영향 (Effect of Surface Free Energies on Mechanical Properties of Epoxy/Polyurethane Blend System)

  • 박수진;진중성;이재락;박병기
    • 폴리머
    • /
    • 제24권2호
    • /
    • pp.245-251
    • /
    • 2000
  • 에폭시 (EP) 수지와 폴리우레탄(PU) 으로 제조된 블렌드 시스템의 접촉각과 기계적 특성을 연구하였다. EP의 경화제로 20 phr의 DDM (4,4'-diamino diphenyl methane)이 사용되었으며 EP/PU의 함량은 100/0~100/60까지 변화시켰다. 접촉각은 Rame-Hart goniometer를 사용 하였으며 젖음액으로는 증류수와 diiodomethane을 사용하였다. 본 연구에서는 geometric 방법을 사용한 Owens-Wendt와 Wu's model이 블렌드 시스템의 표면 자유에너지를 알아보는데 사용되었다. 시편의 기계적 성질과 강인성은 임계 응력 세기 인자(critical stress intensity factor, $K_{IC}$)와 충격 강도 시험을 통하여 알아보았다. 그리고 특히 충격 강도는 상온과 극저온에서 알아보았다. 그 결과로서, 블렌드 시스템에 있어서 표면 자유에너지의 극성 요소는 저온에서 충격 강도를 증가시키는 PU의 함량에 크게 영향을 주었음을 알 수 있었다.

  • PDF

Intra-Rater Test-Retest Reliability of Ely's Test Using Smartphone in Patients With Lumbar Extension-Rotation Syndrome

  • Park, Kyue-Nam;Ha, Sung-Min;Chung, Sung-Dae;Kim, Si-Hyun;Jang, Jun-Hyeok
    • 한국전문물리치료학회지
    • /
    • 제19권4호
    • /
    • pp.46-54
    • /
    • 2012
  • Ely's test is commonly used to assess rectus femoris muscle flexibility. however, a reliability limit of this test was demonstrated by a previous study. In this study, we present an alternative method using an application for a digital horizontal level in a smartphone (DHLS) to complement the reliability limit of Ely's test. The aim of this study was to examine the reliability of Ely's test using DHLS on the pelvis, compared to using visual observation (VO) of pelvic and hip motions. Nineteen patients with lumbar extension-rotation syndrome were recruited for this study. An examiner examined the rectus femoris flexibility (both pass/fail and goniometer scoring) through Ely's test using both DHLS and VO. A retest session was completed two hours later for within-day reliability and seven days later for between-day intra-rater test-retest reliability. Results showed higher Kappa values for pass/fail scoring and higher intraclass correlation coefficient values for goniometer scoring in Ely's test using DHLS, compared to using VO. Measurement error and Bland and Altman plots further demonstrated the degree of intra-rater variance during Ely's test using DHLS in a clinical setting, compared to using VO. These results demonstrated that Ely's test using DHLS showed acceptable reliability compared to using VO. Ely's test using DHLS could be widely used for measuring the rectus femoris muscle flexibility in patients with lumbar extension-rotation syndrome, although the inter-rater reliability needs to be established first.

관절염질환자의 관절가동범위에 대응한 착탈의 동작평가 (The Motion Evaluation of Arthritis Patients' Dressing and Undressing Corresponding to their Joint Range of Motion)

  • 한승희;최미성
    • 한국의상디자인학회지
    • /
    • 제14권2호
    • /
    • pp.75-87
    • /
    • 2012
  • This study aims at measuring and comparing the joint range of motion(ROM) of the elderly, quantitatively understanding the joint ROM and duration for their dressing and undressing of pants with 3D motion analysis equipment, and thereby providing basic data necessary for the future development of clothes carrying functional designs. The findings are as follows. As for the study method, the 9-item joint ROM measurements were conducted with goniometer, and the questionnaire analyses were carried out for t-test, ANOVA, and regression analysis with spss12.0 program. The 3D motion analyses were handled with 3D Motion Analysis Package Version 3.1 Program. The findings are as follows. First, the ROM was shown to be significantly low, as the arthritis-pain consciousness level was felt higher by the subject than the average one. Seven ROM variables, such as hip flexion, hip adduction, hip internal rotation, hip external rotation, knee flexion, ankle dorsiflexion, and ankle plantar flexion, were shown to significantly affect the discomfort level experienced at the time of dressing or undressing. Second, in the motion of inserting the remaining leg into the pant crotch part(3e), the difference of angles in the hip joint and knee joint was the largest between the women in their 20s and the elderly women with arthritis. Third.

  • PDF

Study of an Optical Goniometer Using a Multi-Photodiode Sensor

  • Kim, Ji-Sun;Kim, A-Hee;Oh, Han-Byeol;Kim, Jun-Sik;Goh, Bong-Jun;Lee, Eun-Suk;Choi, Ju-Hyeon;Baek, Jin-Young;Jun, Jae-Hoon
    • Journal of the Optical Society of Korea
    • /
    • 제20권1호
    • /
    • pp.22-28
    • /
    • 2016
  • The monitoring and measurement of the motion of a human joint is very important in screening for degenerative brain diseases and tracking the rehabilitation process. Since there are various medical fields to benefit from angular motion measurement, the necessity for monitoring of human joint movement is increasing. In this study, the optical sensor is composed of a light emission unit with a red LED and an optical fiber, and a reception unit with an arrangement of three photodiodes. The angular detection range was widened with the use of multiple photodiodes and the developed algorithm. The result will be useful for designing an effective angular sensor with low cost and small size.

다양한 발목각도에 따른 스쿼트 시 오른쪽 다리의 근 활성도 비교 (The Comparison of Muscle Activities in the Right Leg during Squatting According to Various Ankle Angles)

  • 안수홍;이수경;이광준;박진성;황제웅
    • PNF and Movement
    • /
    • 제15권3호
    • /
    • pp.259-266
    • /
    • 2017
  • Purpose: This study aimed to compare muscle activities in the right leg during squatting on an angle-adjustable inclined wooden plate at three different angles. Methods: The subjects were 19 healthy adult men and women. An angle-adjustable inclined wooden plate was used for the experiment, and the subjects performed squatting at three adjusted angles of $0^{\circ}$ ankle angle, $10^{\circ}$ ankle flexion, and $10^{\circ}$ plantar flexion. Squatting was randomly performed without a sequence. The knee angle was set at $45^{\circ}$, and a goniometer was used to measure the angles accurately. Electromyography was employed to measure and compare muscle activity in the right leg in each condition. The measured data were converted to root mean square values to calculate the muscle activities. Results: This study showed no statistically significant difference at a $0^{\circ}$ ankle angle, but a statistically significant difference was found in the vastus medialis at $10^{\circ}$ of ankle flexion. Moreover, statistically significant differences were observed in the vastus medialis and lateralis at $10^{\circ}$ of plantar flexion. Conclusion: This study showed a statistically significant difference in the vastus medialis at $10^{\circ}$ of ankle flexion and statistically significant differences in the vastus medialis and lateralis at $10^{\circ}$ of plantar flexion. Therefore, it may be effective to perform squatting at $10^{\circ}$ of ankle flexion when intending to selectively strengthen the vastus medialis and at $10^{\circ}$ of plantar flexion when intending to strengthen both the vastus medialis and lateralis.

성인의 주관절 굴곡 각도가 파악력과 핀치력에 미치는 영향 (The Effect on grasp and pinch strength according to degree of elbow flexion in normal adult)

  • 이규리;김근조;김본원
    • 대한정형도수물리치료학회지
    • /
    • 제14권2호
    • /
    • pp.25-33
    • /
    • 2008
  • Purpose : This study was investigated the effect on grasp and pinch strength according to degree of flexion in elbow joint. Methods : Thirty male and thirty female students, aged 20 to 31 years were tested for using opened positioning with their shoulder abduction at $55^{\circ}$ and shoulder horizontal adduction at $30^{\circ}$ in four elbow flexion($0^{\circ}$, $45^{\circ}$, $90^{\circ}$, $135^{\circ}$). An electronic dynamometer(E-LINK V900s Evaluation System)and goniometer were used to measure grasp and pinch strength. Results : The average grasp strength of the dominant hand was strongest at elbow $45^{\circ}$ however, weakest at elbow $135^{\circ}$ flexion in both of male and female. The average pinch strength of the dominant hand was strongest at elbow $135^{\circ}$ flexion in both of male and female. The average pinch strength of dominant hand was weakest at elbow $45^{\circ}$ flexion in both of male and female. According to degree of elbow flexion in both of male and female, grasp and pinch strength was no significant statistically. In analyzing correlations, the grasp strength of male showed the most significant difference at elbow $45^{\circ}$ & $90^{\circ}$ flexion, and the pinch strength was most significant difference at elbow $0^{\circ}$ & $45^{\circ}$ flexion. Conclusion : In analyzing correlations, the grasp strength of female showed the most significant difference at elbow $90^{\circ}$ & $135^{\circ}$ flexion, and the pinch strength was most significant difference at elbow $45^{\circ}$ & $90^{\circ}$ flexion.

  • PDF