• 제목/요약/키워드: Gold section

검색결과 54건 처리시간 0.024초

3차원 LIGA 미세구조물 제작을 위한 마이크로 액추에이터 내장형 X-선 마스크 (Deep X-ray Mask with Integrated Micro-Actuator for 3D Microfabrication via LIGA Process)

  • 이광철;이승섭
    • 대한기계학회논문집A
    • /
    • 제26권10호
    • /
    • pp.2187-2193
    • /
    • 2002
  • We present a novel method for 3D microfabrication with LIGA process that utilizes a deep X-ray mask in which a micro-actuator is integrated. The integrated micro-actuator oscillates the X-ray absorber, which is formed on the shuttle mass of the micro-actuator, during X-ray exposures to modify the absorbed dose profile in X-ray resist, typically PMMA. 3D PMMA microstructures according to the modulated dose contour are revealed after GG development. An X-ray mask with integrated comb drive actuator is fabricated using deep reactive ion etching, absorber electroplating, and bulk micromachining with silicon-on-insulator (SOI) wafer. 1mm $\times$ 1 mm, 20 $\mu$m thick silicon shuttle mass as a mask blank is supported by four 1 mm long suspension beams and is driven by the comb electrodes. A 10 $\mu$m thick, 50 $\mu$m line and spaced gold absorber pattern is electroplated on the shuttle mass before the release step. The fundamental frequency and amplitude are around 3.6 kHz and 20 $\mu$m, respectively, for a do bias of 100 V and an ac bias of 20 $V_{p-p}$ (peak-peak). Fabricated PMMA microstructure shows 15.4 $\mu$m deep, S-shaped cross section in the case of 1.6 kJ $cm^{-3}$ surface dose and GG development at 35$^{\circ}C$ for 40 minutes.

The influence of different scan resolutions on the detection of proximal caries lesions

  • Ferreira, Liana Matos;Queiroz, Polyane Mazucatto;Santaella, Gustavo Machado;Wenzel, Ann;Groppo, Francisco Carlos;Haiter-Neto, Francisco
    • Imaging Science in Dentistry
    • /
    • 제49권2호
    • /
    • pp.97-102
    • /
    • 2019
  • Purpose: This study was conducted to evaluate the effect of different spatial resolutions of a photostimulable phosphor plate (PSP) radiography system on the detection of proximal caries lesions. Materials and Methods: Forty-five extracted human permanent teeth were radiographed using a PSP system (VistaScan Perio Plus) and scanned at the 4 resolutions (10 lp/mm, 20 lp/mm, 25 lp/mm, and 40 lp/mm) available in the system. Three independent examiners scored the images for the presence and absence of proximal caries lesions using a 5-point scale. The presence or absence of caries was confirmed by histological sections of the examined teeth (defined as the gold standard). Intra- and inter-observer reproducibility was calculated by the weighted kappa test. One-way analysis of variance with the post hoc Tukey test was used to compare the area under the receiver operating characteristic curve for the classifications made with each resolution. Results: For the detection of enamel lesions, the spatial resolution of 10 lp/mm was significantly superior to the other resolutions. However, the spatial resolution did not affect the detection of caries lesions in dentin (P>0.05). Conclusion: Spatial resolution may influence the accuracy of the detection of incipient caries lesions in radiographs with PSP plates. Images with low spatial resolution seem to be more appropriate for this purpose.

총담관결찰후 집토끼 Paneth세포의 변화에 대한 면역전자현미경적 연구 (Immunoelectron Microscopic Study on the Paneth Cell of Rabbit after the Common Bile Duct Ligation)

  • 박경호;조휘동;양남길;안의태;고정식;김진국
    • Applied Microscopy
    • /
    • 제24권2호
    • /
    • pp.78-92
    • /
    • 1994
  • Lysozyme has been reported to be present in the secretory granules of the Paneth cell, and lysozyme immunoreactivity has been detected by immunogold method in Paneth cells of the intestine of human, mouse and rat. The present study was aimed at clarifying the intracellular distribution and changes of the lysozyme immunoreactivity in rabbit Paneth cell after common bile duct ligation of rabbit, using the electron microscope immunogold technique. Healthy adult rabbits weighing about 2kg body weight were divided into normal and bile duct ligated groups. Common bile duct ligation was performed aseptically under ether anesthesia. Experimental animals were sacrificed on the 1st, the 3rd, the 5th, the 7th and the 14th day after the operation. Mucosal specimens from the intestinal gland of ileum were fixed in 2.5% glutaraldehyde-1.5% paraformaldehyde, followed by 1% osmium tetroxide, embedded in araldite mixture, cut with LKB-V ultratome. Ultrathin sections were placed on parlodion coated nickel grids (200mesh). The section-bearing grids were floated upside down on the added substance in a moist chamber at room temperature except for the primary antibody step, which was at $4^{\circ}C$. Sections were etched with a saturated solution of sodium m-periodate for 60min. After etching, sections were pretreated with 0.02M tris buffered saline (TBS), pH 8.4, with 1% bovine serum albumin (BSA, Sigma) for 60min, then treated polyclonal rabbit anti-human lysozyme (Dakipatts) diluted 1 : 50 in TBS with 0.1% BSA for 20hr. Subsequently, grids were incubated 60min in biotinylated goat anti rabbit IgG (Amersham) diluted 1 : 100 in TBS with 0.1% BSA. After this, sections were incubated 60min on streptavidin gold G10 (Amersham) diluted 1 : 50 in TBS with 0.1% BSA. After each step, the grids were briefly rinsed with TBS with 0.1% BSA. After the strepavidin gold step, the sections were jet washed with distilled water. Counterstain of the sections performed by uranyl acetate and lead citrate, and observed with JEM 100 CX II electron microscope. Observed results were as follow; 1. Secretory granules of mouse Paneth cells have a lysozyme immunoreactivity and also eosinophil leucocyte of rabbit applied for the positive-control stain, are well labeld with gold particles. 2. Normal rabbit Paneth cells have a lysozyme immunoreactivity restricted on the secretory granules. 3. Amount lysosomes containing myelin figures in the Paneth cells were significantly increased from 5th day after the common bile duct ligation. 4. Immunoreactivity of Paneth cell secretory granules were more activated on the 3rd day after the common bile duct ligation as compared with those of the normal animal. But the lysozyme immunoreactivity were decreased from the 5th day after the common bile duct ligation. 5. Considering the above finding, lysozyme contained Paneth cell are affected following of common bile duct ligation, whereas lysosomes containing myelin-figure do not exhibit any immunoreactive relationship with those of secretory granules.

  • PDF

3T 자기공명영상 Fast Spin Echo (FSE)와 Ultra Short Time Echo (UTE) 펄스 시퀀스에서 가돌리늄 조영제 희석농도와 신호강도 비교 -팬텀 연구 (A Comparison Study of Signal Intensity of Gadolinium Contrast Media on Fast Spin echo and Ultra Short Time Echo Pulse Sequence at 3T MRI-Phantom Study)

  • 이석준;유승만
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권3호
    • /
    • pp.253-259
    • /
    • 2015
  • 본 연구에서는 가돌리늄 조영제를 다양한 몰농도로 희석하여 T1 효과를 나타내는 펄스 시퀀스 중 고속스핀에코와 에코타임이 극도로 짧은 ultra short time echo에서 최대 신호 강도 분포를 나타내는 조영제 희석 몰농도를 3.0T에서 각각 알아보고자 하였다. T1 조영제인 gadoxetic acid 와 완충용액으로는 증류수, 2% agarose gel을 이용하여 다양한 몰농도로 조영제 팬텀을 제작하였다. 팬텀 제작의 정확성을 측정하기 위해 T1 이완시간 측정의 표준방식인 2D inversion recovery spine-echo 펄스시퀀스를 이용하였으며 팬텀의 중간 부의 한 개의 관상면 영상을 획득하여 T1 이완 시간을 계산하였다. 스핀에코에서는 1-2 mmol/L 조영제 몰농도에서 가장 높은 신호를 나타냈으며, ultra short time echo에서는 7 mmol/L에서 가장 큰 신호를 나타냈다. ultra short time echo 펄스 시퀀스를 이용한 조영증강 효과를 보기 위해서는 고속스핀에코 기법 보다 2-3배의 조영제 농도가 목적 장기에 유지하여야 하며 이와 관련된 조영제량 및 투여 방법의 연구가 이루어져야 한다.

IV형의 골질로 재생된 골내에 식립된 원통형 임플란트의 유한요소법적 연구 (FINITE ELEMENT ANALYSIS OF CYLINDER TYPE IMPLANT PLACED INTO REGENERATED BONE WITH TYPE IV BONE QUALITY)

  • 김병옥;홍국선;김수관
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권4호
    • /
    • pp.331-338
    • /
    • 2004
  • Stress transfer to the surrounding tissues is one of the factors involved in the design of dental implants. Unfortunately, insufficient data are available for stress transfer within the regenerated bone surrounding dental implants. The purpose of this study was to investigate the concentration of stresses within the regenerated bone surrounding the implant using three-dimensional finite element stress analysis method. Stress magnitude and contours within the regenerated bone were calculated. The $3.75{\times}10-mm$ implant (3i, USA) was used for this study and was assumed to be 100% osseointegrated, and was placed in mandibular bone and restored with a cast gold crown. Using ANSYS software revision 6.0, a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The present study used a fine grid model incorporating elements between 165,148 and 253,604 and nodal points between 31,616 and 48,877. This study was simulated loads of 200N at the central fossa (A), at the outside point of the central fossa with resin filling into screw hole (B), and at the buccal cusp (C), in a vertical and $30^{\circ}$ lateral loading, respectively. The results were as follows; 1. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were increased from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, concentrated on the top of the cylindrical collar loading point B and C in vertical loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were increase from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in vertical loading. 2. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were decreased from loading point A to C in lateral loading. Stresses according to the depth of regenerated bone were concentrated on the top of the cylindrical collar in loading point A and B, distributed along the implant evenly in loading point C in lateral loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were decreased from loading point A to C in lateral loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in lateral loading. In summary, these data indicate that both bone quality surrounding the regenerated bone adjacent to implant fixture and load direction applied on the prosthesis could influence concentration of stress within the regenerated bone surrounding the cylindrical type implant fixture.

Optical Coherence Tomography를 이용한 초기 치아우식 검사 (Assessment of Early Dental Caries by Using Optical Coherence Tomography)

  • 민지현
    • 치위생과학회지
    • /
    • 제16권4호
    • /
    • pp.257-262
    • /
    • 2016
  • TMR은 초기우식 평가의 gold standard로 여겨지나 시편을 파괴하여야만 시편의 무기질 밀도를 확인할 수 있는 실험법이다. 그러나 OCT는 비파괴적인 검사법으로 임상에서도 초기우식을 확인하는 데 사용하므로 본 연구에서는 $200{\mu}m$ 이상의 깊은 법랑질 초기우식에서의 OCT와 TMR에서 구한 integrated mineral loss값 간의 상관성을 확인하고자 하였다. $200{\mu}m$ 이상의 깊이를 갖는 인공 초기우식병소를 제작하여 TMR (${\Delta}Z_{TMR}$)과 OCT (${\Delta}R_{OCT}$)에서 구한 integrated mineral loss를 각각 구하여 상관성 분석을 시행하였으며 Bland-Altman plot을 그려 두 값 간의 오차 분석을 시행하였다. ${\Delta}R_{OCT}$${\Delta}Z_{TMR}$ 간에는 유의한 상관성이 확인되었으며(r=0.491, p=0.003), Bland-Altman plot 상에서도 ${\Delta}Z_{TMR}$${\Delta}R_{OCT}$값 간의 차이가 거의 대부분 오차 구간 내에 있는 것이 확인되어 두 측정 방법 간의 오차가 적은 것으로 확인되었다. 따라서 치과임상에서 OCT를 활용하면 초기우식병소의 탐지 및 모니터링 그리고 초기우식병소의 심도 파악이 가능할 것으로 여겨진다.

상악 중절치 근관치료후 수복 방법에 따른 응력 분포의 유한 요소 분석 (FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION ACCORDING TO THE METHOD OF RESTORATION AFTER ROOT CANAL THERAPY)

  • 이재영;이정식
    • Restorative Dentistry and Endodontics
    • /
    • 제19권2호
    • /
    • pp.549-567
    • /
    • 1994
  • Restoration of severly damaged teeth after endodontic treatment had been an interest to many dentists, and it is a fact that there have been lots of studies about it. In these days, although we have used Para-Post, pins, threaded steel post, cast gold post and core, and so on, as a method of restoration frequently, it has been in controversy with the influence of them on the teeth and surrounding periodontal tissue. In this study, we assume that the crown of the upper incisor have severly damaged, so, after the root canal therapy, 4 types of restoration had been carried out; 1) coronal-radicular amalgam restoration, 2) after setting up the Para-Post, restore with composite resin core only, 3) after setting up the Para-Post; restore with amalgam core, then cover with the PPM crown 4) after setting up the Para-Post, restore with composite core, then cover with the PPM crown. After restoration, in order to observe the concentration of stress at internal portion of the teeth and the sourrounding periodontal tissue, developing a 2-dimensional finite element model of labiopalatal section, then loading forces from 3 direction - direction of 45 degrees from lingual side near the incisal edge, horizontal direction from labial height of contour, vertical direction at the incisal edge-were applied. The analyzed results were as follows: 1. Stress of the normal central incisor was concentrated on the dentin aroundpulp chamber, labiocervical portion of a tooth and root apex, but with the alveolar bone, in the case of load from the direction of 45 degrees from lingual side near the incisal edge showed remarkable concentration of stress: 2. Coronal-radicular amalgam technique -showed less concentration of stress on the root and surrounding periodontal tissue than the restoration with the Para-Post. 3. The von Mises equivalent stress on the Para-Post showed maximum value at root-core junction rather than both ends and model with PPM restoration with amalgam core showed the least concentration of stress. Only the force from horizontal direction showed large shear stress on internal portion of the root, root apex and alveolar bone. 4. PPM crown with composite core rarely showed the concentration of stress on root and periodontal tissue. 5. As for alveolar bone, remarkable shear stress was concentrated on labial and palatal side by horizontal load.

  • PDF

재생된 골에 식립한 넓은 직경의 나사형 임플란트에 대한 유한요소법적 분석 (FINITE ELEMENT ANALYSIS OF WIDE DIAMETER SCREW IMPLANT PLACED INTO REGENERATED BONE)

  • 김수관;김재덕;김종관;김병옥
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권3호
    • /
    • pp.248-254
    • /
    • 2005
  • The purpose of this study was to investigate the distribution of stress within the regenerated bone surrounding the implant using three dimensional finite element stress analysis method. Using ANSYS software revision 6.0 (IronCAD LLC, USA), a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The $5.0{\times}11.5-mm$ screw implant (3i, USA) was used for this study, and was assumed to be 100% osseointegrated. And it was restored with gold crown with resin filling at the central fossa area. The implant was surrounded by the regenerated type IV bone, with 4 mm in width and 7 mm apical to the platform of implant in length. And the regenerated bone was surrounded by type I, type II, and type III bone, respectively. The present study used a fine grid model incorporating elements between 250,820 and 352,494 and nodal points between 47,978 and 67,471. A load of 200N was applied at the 3 points on occlusal surfaces of the restoration, the central fossa, outside point of the central fossa with resin filling into screw hole, and the functional cusp, at a 0 degree angle to the vertical axis of the implant, respectively. The results were as follows: 1. The stress distribution in the regenerated bone-implant interface was highly dependent on both the density of the native bone surrounding the regenerated bone and the loading point. 2. A load of 200N at the buccal cusp produced 5-fold increase in the stress concentration at the neck of the implant and apex of regenerated bone irrespective of surrounding bone density compared to a load of 200N at the central fossa. 3. It was found that stress was more homogeneously distributed along the side of implant when the implant was surrounded by both regenerated bone and native type III bone. In summary, these data indicate that concentration of stress on the implant-regenerated bone interface depends on both the native bone quality surrounding the regenerated bone adjacent to implant and the load direction applied on the prosthesis.

수동과 엔진구동형 기구를 이용한 난원형 근관의 형성에 관한 주사전자현미경적 관찰 (A SEM OBSERVATION ON THE EFFICIENCY PREPARATION OF OVAL CANALS USING HAND AND ENGINE-DRIVEN INSTRUMENTS)

  • 송욱;허복;이희주
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.141-146
    • /
    • 2004
  • The purpose of this study was to evaluate the efficiency of the preparation of oval canals using hand and engine-driven instruments with SEM observation. Thirty single-rooted teeth with oval canal were used in this study. The teeth were divided into 3 groups. In group A the teeth were instrumented up to a size 35 K-file using RC-prep and irrigated with 5% NaOCl between each file size. In group B. the teeth were instrumented with Profile according to the manufacture's instructions using RC-Prep and irrigated with 5% NaOCl between each file size. In group C. the teeth were instrumented with GT file according to the manufacture's instructions using RC-prep and irrigated with 5% NaOCl between each file size. Then. in all teeth. a final flush of 5ml of distilled water delivered for 30s. Canals were dried with sterile standardized paper points. After preparing the canals, the teeth were sectioned along their mesial and diatal surfaces by using low-speed diamond disc. chisel and mallet. Each root section was then dehydrated in graded concentration of alcohol (70, 80, 90, 100%). mounted on an aluminum stub. sputter-coated with gold-palladium and observed with scanning electron microscope (HITACHI S-4200) in middle and apical area. The results of this study were as follows: 1. In the middle area. group B and group C showed less smear layer than group A and it was statistically significant (p < 0.05). 2. In the middle area. group B showed greater smear layer than group C. but it was not statistically significant (p > 0.05). 3. In the apical area, group C showed less smear layer than group A. and it was statistically significant (p < 0.05). 4. In the apical area. group A showed greater smear layer than group B. but it was not statistically significant (p > 0.05). 5. In the apical area. group B showed greater smear layer than group C. but it was not statistically significant (p > 0.05). 6. In all groups. the middle area was less smear layer than the apical area. and it was statistically significant (p < 0.05).

보물 제1752호 고창 선운사 소조비로자나삼불좌상 재질특성 및 제작기법 연구(1): 소조불상 주요 구성재료 분석 (Study on the Characteristics of Materials and Production Techniques of Clay Seated Vairocana Buddha Triad of Seonunsa Temple, Gochang)

  • 이화수;이한형;한규성
    • 보존과학회지
    • /
    • 제36권6호
    • /
    • pp.562-577
    • /
    • 2020
  • 보물 제1752호 고창 선운사 소조비로자나삼불좌상 보존을 위해 불상을 구성하는 주요 재질에 대한 과학적 분석을 실시하였다. 소조불상을 구성하는 토양층 분석결과 중립사 이상의 모래와 세립사 이하의 토양이 3:7의 비율로 쓰인 것으로 나타났으며, 닥나무의 인피섬유도 함께 확인되었다. 따라서 소조토는 모래와 풍화토를 혼합하고 분산방지를 위해 닥지를 섬유질로 첨가한 것을 알 수 있다. 수종분석 결과, 아미타여래, 비로자나불, 약사여래의 좌대 및 팔 부위를 구성하는 목재는 모두 경송류(Hard pines)로 식별되었으며, 개금층 분석 결과, 시료 단면에서 3개의 층위가 확인되었다. 불상의 나발은 석영, 조장석, 미사장석, 운모, 자철석 등 토양성 물질로 구성되었으며, 나발의 표면은 자철석이 함유된 흑색물질을 이용하여 표면을 채색한 것으로 판단된다.