• 제목/요약/키워드: Goggle

검색결과 30건 처리시간 0.019초

시각장애인 의약품 정보 안내를 위한 RFID 고글 개발 (Development of an RFID Goggle to Deliver Medication Information to the Blinds)

  • 김진영;강준희
    • 센서학회지
    • /
    • 제23권2호
    • /
    • pp.122-126
    • /
    • 2014
  • Recent development of ubiquitous technology prompted its application for the blinds. In this work, we developed an RFID goggle equipped with a voice guide for the blinds who have difficulties in obtaining medication informations. When a blind, wearing our RFID goggle, tags the RFID tag attached to a drug, the RFID goggle announces the already saved medication information. We used STM32 as MCU and MFRC523 for RFID chipset in the reader. Our miniaturized hardware supported ISO 14443A protocol, and the standardized conformance test was performed. When the blinds wear our RFID goggle, they can conveniently access to the medication informations, and thus the drug misuse cases may decrease.

고글 및 선글라스의 판매에 대한 판매인의 안경 지식에 관한 연구 (Study and Research of Seller's Optical Knowledge About Sale of Goggle or Sun-glasses)

  • 이지민;조현래;장우영
    • 한국안광학회지
    • /
    • 제14권4호
    • /
    • pp.1-10
    • /
    • 2009
  • 목적: 이 연구는 최근 고글 및 선글라스가 공산품으로 규정되어 있어 안경원 외의 장소에서 비전문가가 판매하고 있는데, 그에 따라 안경사가 아닌 비전문가가 판매하므로써 안경테 및 안경 렌즈의 재질과 커브, A/S 사항이 현실적으로 체크가 불가능하여 국민의 안보건을 위협하고 있다. 따라서 안경원을 제외한 고글 및 선글라스의 판매인들이 얼마나 안경에 대한 지식이 있고 어떠한 서비스를 할 수 있는지 알아보기 위하여 조사연구를 하였다. 방법: 연령에 상관없이 안경원 근무자, 안경사를 제외한 고글 및 선글라스 판매인 100명과 안경원을 제외한 판매점에서 고 글 및 선글라스를 구매한 208명을 대상으로 설문 조사하였다. 결과: 대다수의 판매인들은 안경에 대한 지식 없이 판매를 하고 안경에 대한 지식이 있더라도 많이 부족한 현실이었다. 결론: 안경 렌즈와 관련된 모든 것은 안경원에서 전문적인 지식이 있는 안경사가 직접 판매하고 관리하는 방식이 필요하다. 그래서 하루 빨리 공산품으로 되어있는 고글 및 선글라스가 의료용구로 변환시키는 대책이 필요하다.

  • PDF

중재적 방사선 분야 방호용구 차폐효과 (Shielding Effect of Radiation Protector for Interventional Procedure)

  • 고신관;강병삼;임청환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권3호
    • /
    • pp.213-219
    • /
    • 2007
  • 중재적 시술의 시술자를 대상으로 방사선 방호용구의 안과 밖의 실제 방사선량을 측정하여 이를 바탕으로 방사선 방호용구의 방사선 차폐율을 비교 분석하는 것이다. 2005년 5월부터 9월까지 중재적 시술 중에서 시행 빈도가 높은 TACE, PTBD를 시행하는 중재적 시술자 4인에게 방사선 방호용구의 착용 시 피폭선량 감쇄효과를 측정하기 위해 각 신체부위별 방호용구 안과 밖에 TLD를 부착하여 피폭선량을 측정하였다. TLD 부착부위는 Goggle inside, Goggle outside, Thyroid protector inside, Thyroid protector outside, Apron inside(waist level), Apron outside(upper chest level), Hand 4th finger(ring type TLD)와 환경방사선을 측정하기 위해 TLD 10개를 Control room 여러 곳에 위치시켰다. TACE 검사시 0.07 mmPb Goggle의 사용으로 연속투시방식에서는 평균 53.8%의 선량율감쇄를 보였으며 펄스투시방식에서는 77.6%의 감쇄효과를 보였고, 0.5 mmPb Thyroid protector의 사용에서는 연속투시방식에서는 평균 88.9%의 선량율감쇄를 보였으며 펄스투시방식에서는 92.8%로 선량율감쇄에서는 유의한 차이가 없었다. PTBD 검사시 0.07 mmPb Goggle의 사용으로 평균 62.7%의 선량율감쇄를 보였으며, 0.5 mmPb Thyroid protector의 사용에서는 평균 89.1% 선량율이 감쇄 되었고 0.5 mmPb Apron의 사용에서도 평균 87.9%의 감쇄효과가 있었다. PTBD 시술은 TACE 시술에 비해 평균 투시시간은 6.14 min이나 적었으나 피폭선량은 체부에서 약 3배, 손에서는 40배 이상 피폭되었다. 납당량이 두꺼운 방호용구를 착용하거나 최소한 권고되어지는 0.5 mmPb 이상의 것을 착용하여야 하며, 시술시 눈을 보호하는 Goggle의 착용을 생활화해야 한다. 테이블 아래쪽에 납커튼을 장착하면 복부의 피폭선량율은 평균 38.4% 감쇄하므로 납커튼을 장착하여 산란선을 차폐하여야 한다. 펄스투시방식을 이용하면 연속투시에 비해 피폭선량율이 평균 59.0% 감쇄되므로 연속투시보다 펄스투시방식을 선택하여 피폭선량을 감소시켜야 한다.

  • PDF

항공기 야간투시경 운용 (Operation of Night Vision Goggle for Aircraft)

  • 권종광;김환우
    • 한국군사과학기술학회지
    • /
    • 제9권2호
    • /
    • pp.34-41
    • /
    • 2006
  • This paper describes the general considerations and operational applications of aircraft night vision goggle(NVG). The operators should recognize the NVG characteristics, natural night light sources and interoperability between them. And they have to keep attention to the method to take steps to avoid misperceptions, illusions during flight, and the negative impact on the effectiveness and safety of the mission. The considerations based on the interoperability between NVG and night operation suggest the evaluation items of NVG field test and flight test.

시각유발전위 검사상 후-시신경교차부위병변을 보인 환자들의 뇌 영상 결과와의 연관성 (Visual Evoked Potentials in Retrochiasmal Lesion; Correlation with Neuroimaging Study)

  • 김성훈;조용진;김호진;이광우
    • Annals of Clinical Neurophysiology
    • /
    • 제2권1호
    • /
    • pp.13-20
    • /
    • 2000
  • Background and Objective : Visual evoked potentials(VEPs) is considered to be a reliable diagnostic procedure for examining patients with anterior visual pathways. Some abnormalities in the recordings on monocular stimulation have been said to indicate retrochiasmal lesion, but less consistent results have been reported. This study is to evaluate the positive predictability of VEP for the detection of retrochiasmal lesion. Methods : We reviewed VEPs that could be interpreted as indicative of a retrochiasmal lesions, based on amplitude or latency asymmetry recorded on the left(O1) and right(O2) occipital regions. Bilateral absent VEPs on both recording(O1 and O2) without evidence of prechiasmal lesion were included. During 5 years, we identified 31 patients who met the above criteria and who had undergone magnetic resonance imaging(MRI) of brain(one patient underwent computerized tomography). Twenty three patients underwent pattern reversal VEPs and others underwent flash goggle VEPs. Results : Brain imagings were abnormal in 29 and were normal in 2. Of the 29 abnormal scans, lesions in posterior visual pathway were detected in 21 scans(predictive value=68%). The predictive value was not significantly different between flash goggle VEP(75%) and pattern reversal VEP(68%). The predictive value was higher in patient with visual field defect(100%) than those without visual field defect(25%). The pathologic nature of lesion also showed close relations to the predictive value. VEPs is usually paradoxically lateralized(78%), but not in all patients. Conclusion : VEPs abnormalities suggesting retrochiasmal lesion were usually corresponded with brain MRI findings. Diagnostic reliability could be increased when considering the visual field defect and nature of lesion. Therefore, the authors suggest that VEPs studies could be useful in evaluating the patients with the retrochismal lesion.

  • PDF

Occupational factors affecting the decline in pulmonary function among male farmers using occupational pesticide in Gyeonggi-do, South Korea

  • Sooyeon Lee;Jiyoung Han;Seung Hee Woo;Soo-Jin Lee
    • Annals of Occupational and Environmental Medicine
    • /
    • 제34권
    • /
    • pp.42.1-42.11
    • /
    • 2022
  • Background: Occupational pesticide exposure is a potential risk for respiratory health effects. Most clinical studies on pesticide exposure were related to acute exposure, and only a few studies on chronic exposure have been conducted. This study investigated the chronic respiratory health status and the chronic effects of occupational pesticide exposures of farmers in Gyeonggi-do. Methods: Surveys and pulmonary function tests were conducted on 1,697 farmers in 16 regions of Gyeonggi-do. The structured questionnaire included demographic characteristics, medical history, recent respiratory symptoms and diseases, and work-related conditions, and was conducted through one-on-one interviews. The prevalence of respiratory diseases was compared by the odds ratios (ORs) at 95% confidence intervals (CIs) estimated by logistic regression analysis. Additional multivariate logistic regression analysis was also conducted. Results: Pesticide work groups showed significant association with an obstructive pattern in the lung function test (unadjusted OR, 2.38; 95% CI, 1.17-5.52). Selected work-related variables of pesticide exposure were 'start age,' 'cumulative duration,' 'mixing pesticides,' and 'protection(goggle).' The obstructive pattern of lung function test showed significant associations with mixing pesticides (OR, 2.30; 95% CI,1.07-5.46), and protection (goggle) use (OR, 0.34; 95% CI, 0.12-0.79). Conclusions: Mixing two or more pesticides showed a significant association. Wearing goggles can be seen as an indicator of awareness of the protective equipment and proper wearing of protective equipment, and loss of pulmonary function can be prevented when appropriate protection is worn.

야간산불진화 헬기 운영과 항공안전 (Night fire fighting helicopters operations and Aviation Safety)

  • 최연철
    • 한국항공운항학회지
    • /
    • 제22권1호
    • /
    • pp.145-151
    • /
    • 2014
  • Not only in Korea, but also in other countries, most helicopter accidents occur at low altitude. Analysis on accidents data collected both in Korea and other countries has brought two conclusions. Firstly, helicopter operations during the night hours carries a high risk. Secondly, the most common cause of night hour operations is loss of control due to the flight illusion. As an operation relying on a night vision in particular has a very high accident hazard, accompanying instruments such as NVG are ought to be provided. Hence, a thorough preparation and inspection on missions for night forest fire extinguishing should be required and perfect guidelines/road maps and enough training programs for the operation should be provided before the engagement in missions.

운동기반의 실시간 2D-3D 영상 변환 방법 (A motion-based real time 2D to 3D image conversion method)

  • 고윤호;최철호;권병헌;최명렬
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2003년도 춘계학술발표논문집 (상)
    • /
    • pp.659-662
    • /
    • 2003
  • 본 논문에서는 2차원 영상 사이에 움직임 변위를 검출하여 영상내의 원근 깊이를 생성하였으며 양 시차(positive) parallax처리를 하여 입체 영상을 생성한 방법을 제안했다. 이 방식은 2 차원 영상내의 사물의 운동 방향과 속도에 관계없이 3차원 효과를 느낄 수 있다. 제안한 방법은 다양한 영상원에 대해서 실시간으로 입체 영상 변환이 가능하며 LCD shutter goggle 방식의 입체 영상 장치를 통해 실제 시각적인 검증을 수행하였다.

  • PDF