• Title/Summary/Keyword: Goggle

Search Result 30, Processing Time 0.032 seconds

Development of an RFID Goggle to Deliver Medication Information to the Blinds (시각장애인 의약품 정보 안내를 위한 RFID 고글 개발)

  • Kim, Jin Young;Kang, Joonhee
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.122-126
    • /
    • 2014
  • Recent development of ubiquitous technology prompted its application for the blinds. In this work, we developed an RFID goggle equipped with a voice guide for the blinds who have difficulties in obtaining medication informations. When a blind, wearing our RFID goggle, tags the RFID tag attached to a drug, the RFID goggle announces the already saved medication information. We used STM32 as MCU and MFRC523 for RFID chipset in the reader. Our miniaturized hardware supported ISO 14443A protocol, and the standardized conformance test was performed. When the blinds wear our RFID goggle, they can conveniently access to the medication informations, and thus the drug misuse cases may decrease.

Study and Research of Seller's Optical Knowledge About Sale of Goggle or Sun-glasses (고글 및 선글라스의 판매에 대한 판매인의 안경 지식에 관한 연구)

  • Lee, Ji-Min;Jo, Hyun-Rae;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.1-10
    • /
    • 2009
  • Purpose: Recently because goggle and sunglasses is industrial products, unprofessional is selling in store what is not optical store. Due to layman's sale, check of frames or lens, the quality, curve, A/S, is impossible. Therefore layman's sale threated national eye-health. So we investigated in order to know them, merchant of goggle and sunglasses except for optician, about "how many they have optical knowledge?" and "What can they give a service us?" Methods: Regardless age, we get a survey of 208 person who purchased goggle and sunglasses in a store that it is not optical store and 100 of goggle and sunglasses except for optician. Results: Most merchant who haven it knowledge about glasses sells goggle or sunglasses. Even though merchant has knowledge about glasses, It was very littles, now. Conclusions: Optician who have expert knowledge need method that it was very littles. So goggle and sunglasses that it is registered industrial products need method to transform into health instrument.

  • PDF

Shielding Effect of Radiation Protector for Interventional Procedure (중재적 방사선 분야 방호용구 차폐효과)

  • Ko, Shin-Kwan;Kang, Byung-Sam;Lim, Chung-Hwang
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.213-219
    • /
    • 2007
  • The purpose of this study is to evaluate shielding effect of radiation protector for interventional radiologists in procedures by measuring inside and outside of radiation protector. In this study, we measured the radiation dose of 4 interventional radiologists during TACE and PTBD procedure for 4 month(2005.05-2005.09). Absorbed dose were measured by TLD placed underneath and over radiation protector such as Goggle, Thyroid protector, Apron and placed on the 4th finger of Hand. In addition, we measured background radiation dose in the control room using TLD. During TACE procedure, using 0.07 mmPb Goggle decreased average 53.8% of radiation dose rate in continuous fluoroscopic mode and decreased average 77.6% of radiation dose rate in pulse fluoroscopic mode. Using 0.5 mmPb Thyroid protector decreased average 88.9% of radiation dose rate in continuous fluoroscopic mode and decreased average 92.8% in pulse fluoroscopic mode. During PTBD procedure, using 0.07 mmPb Goggle decreased radiation dose rate average 62.7%, 87.9% by 0.5 mmPb Thyroid protector, 90.5% by 0.5 mmPb Apron. The average fluoroscopic time of PTBD was 6.14 min. shorter than TACE procedure, but radiation exposure dose rate of PTBD was 3 times higher in total body dose, and 40 times higher in hand dose rate than TACE. Interventional radiologists must wear thicker protector recommended over 0.5 mmPb. Also, they must use lead Goggle during interventional procedure. Abdomen dose decreased average 38.4% by drawing a lead curtain under the patient's table, therefore, they must draw a lead curtain to shield scattering ray. Radiation exposure dose decreased average 59.0% by using pulse fluoroscopic mode. So radiologists would better use pulse fluoroscopic mode than continuous fluoroscopic mode to decrease exposure dose.

  • PDF

Operation of Night Vision Goggle for Aircraft (항공기 야간투시경 운용)

  • Kwon, Jong-Kwang;Kim, Whan-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.34-41
    • /
    • 2006
  • This paper describes the general considerations and operational applications of aircraft night vision goggle(NVG). The operators should recognize the NVG characteristics, natural night light sources and interoperability between them. And they have to keep attention to the method to take steps to avoid misperceptions, illusions during flight, and the negative impact on the effectiveness and safety of the mission. The considerations based on the interoperability between NVG and night operation suggest the evaluation items of NVG field test and flight test.

Visual Evoked Potentials in Retrochiasmal Lesion; Correlation with Neuroimaging Study (시각유발전위 검사상 후-시신경교차부위병변을 보인 환자들의 뇌 영상 결과와의 연관성)

  • Kim, Sung Hun;Cho, Yong-Jin;Kim, Ho-Jin;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.2 no.1
    • /
    • pp.13-20
    • /
    • 2000
  • Background and Objective : Visual evoked potentials(VEPs) is considered to be a reliable diagnostic procedure for examining patients with anterior visual pathways. Some abnormalities in the recordings on monocular stimulation have been said to indicate retrochiasmal lesion, but less consistent results have been reported. This study is to evaluate the positive predictability of VEP for the detection of retrochiasmal lesion. Methods : We reviewed VEPs that could be interpreted as indicative of a retrochiasmal lesions, based on amplitude or latency asymmetry recorded on the left(O1) and right(O2) occipital regions. Bilateral absent VEPs on both recording(O1 and O2) without evidence of prechiasmal lesion were included. During 5 years, we identified 31 patients who met the above criteria and who had undergone magnetic resonance imaging(MRI) of brain(one patient underwent computerized tomography). Twenty three patients underwent pattern reversal VEPs and others underwent flash goggle VEPs. Results : Brain imagings were abnormal in 29 and were normal in 2. Of the 29 abnormal scans, lesions in posterior visual pathway were detected in 21 scans(predictive value=68%). The predictive value was not significantly different between flash goggle VEP(75%) and pattern reversal VEP(68%). The predictive value was higher in patient with visual field defect(100%) than those without visual field defect(25%). The pathologic nature of lesion also showed close relations to the predictive value. VEPs is usually paradoxically lateralized(78%), but not in all patients. Conclusion : VEPs abnormalities suggesting retrochiasmal lesion were usually corresponded with brain MRI findings. Diagnostic reliability could be increased when considering the visual field defect and nature of lesion. Therefore, the authors suggest that VEPs studies could be useful in evaluating the patients with the retrochismal lesion.

  • PDF

Occupational factors affecting the decline in pulmonary function among male farmers using occupational pesticide in Gyeonggi-do, South Korea

  • Sooyeon Lee;Jiyoung Han;Seung Hee Woo;Soo-Jin Lee
    • Annals of Occupational and Environmental Medicine
    • /
    • v.34
    • /
    • pp.42.1-42.11
    • /
    • 2022
  • Background: Occupational pesticide exposure is a potential risk for respiratory health effects. Most clinical studies on pesticide exposure were related to acute exposure, and only a few studies on chronic exposure have been conducted. This study investigated the chronic respiratory health status and the chronic effects of occupational pesticide exposures of farmers in Gyeonggi-do. Methods: Surveys and pulmonary function tests were conducted on 1,697 farmers in 16 regions of Gyeonggi-do. The structured questionnaire included demographic characteristics, medical history, recent respiratory symptoms and diseases, and work-related conditions, and was conducted through one-on-one interviews. The prevalence of respiratory diseases was compared by the odds ratios (ORs) at 95% confidence intervals (CIs) estimated by logistic regression analysis. Additional multivariate logistic regression analysis was also conducted. Results: Pesticide work groups showed significant association with an obstructive pattern in the lung function test (unadjusted OR, 2.38; 95% CI, 1.17-5.52). Selected work-related variables of pesticide exposure were 'start age,' 'cumulative duration,' 'mixing pesticides,' and 'protection(goggle).' The obstructive pattern of lung function test showed significant associations with mixing pesticides (OR, 2.30; 95% CI,1.07-5.46), and protection (goggle) use (OR, 0.34; 95% CI, 0.12-0.79). Conclusions: Mixing two or more pesticides showed a significant association. Wearing goggles can be seen as an indicator of awareness of the protective equipment and proper wearing of protective equipment, and loss of pulmonary function can be prevented when appropriate protection is worn.

Night fire fighting helicopters operations and Aviation Safety (야간산불진화 헬기 운영과 항공안전)

  • Choi, Youn-Chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.22 no.1
    • /
    • pp.145-151
    • /
    • 2014
  • Not only in Korea, but also in other countries, most helicopter accidents occur at low altitude. Analysis on accidents data collected both in Korea and other countries has brought two conclusions. Firstly, helicopter operations during the night hours carries a high risk. Secondly, the most common cause of night hour operations is loss of control due to the flight illusion. As an operation relying on a night vision in particular has a very high accident hazard, accompanying instruments such as NVG are ought to be provided. Hence, a thorough preparation and inspection on missions for night forest fire extinguishing should be required and perfect guidelines/road maps and enough training programs for the operation should be provided before the engagement in missions.

A motion-based real time 2D to 3D image conversion method (운동기반의 실시간 2D-3D 영상 변환 방법)

  • Ko, Yoon-Ho;Choi, Chyul-Ho;Kwon, Byong-Heon;Choi, Myung-Ryul
    • Annual Conference of KIPS
    • /
    • 2003.05a
    • /
    • pp.659-662
    • /
    • 2003
  • 본 논문에서는 2차원 영상 사이에 움직임 변위를 검출하여 영상내의 원근 깊이를 생성하였으며 양 시차(positive) parallax처리를 하여 입체 영상을 생성한 방법을 제안했다. 이 방식은 2 차원 영상내의 사물의 운동 방향과 속도에 관계없이 3차원 효과를 느낄 수 있다. 제안한 방법은 다양한 영상원에 대해서 실시간으로 입체 영상 변환이 가능하며 LCD shutter goggle 방식의 입체 영상 장치를 통해 실제 시각적인 검증을 수행하였다.

  • PDF