• 제목/요약/키워드: Gluma

검색결과 34건 처리시간 0.03초

상아질 표면처리후 복합레진 수복시 온도변화가 결합에 미치는 영향 (EFFECT OF THERMOCYCLING ON BONDING OF COMPOSITE RESIN AFTER DENTIN SURFACE TREATMENTS)

  • 이용우;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제16권2호
    • /
    • pp.126-142
    • /
    • 1991
  • The purpose of this study was to evaluate the effect of various dentin surface treatments on shear bond strength, microhardness and fracture mode before and after thermocycling. Recently extracted 75 human molars were used. The teeth were sagittal sectioned faciolingually to obtain 150 specimens. They were randomly divided into six groups. Mesial and distal dentinal surfaces of specimens were exposed by grinding and treated respectively with GC-DENTIN CONDITIONER. 10-3 solution of 4-Meta, Cleansar and Primer of GLUMA, Scotchprep of Scotchbond 2, DENTIN CONDITIONER and PRIMER A, B of ALL BOND according to the manufacturers directions. Specimens of one group were not treated. Adhesive agent of Scotchbond 2, were applied and cured on the treated dentin surfaces. After P-50 were cured on them, specimens were stored in 31c water for 24 hours before shear bond strength measurement Shear bond strength was measured in 10 specimens of each group. 10 specimens of each group were thermocycled in $20^{\circ}C$, $60^{\circ}C$,$20^{\circ}C$, $4^{\circ}C$, $20^{\circ}C$ water in order, for 30 seconds respectively, 100 times a day for 7 days. After thermocycling shear bond strength was measured. Microhardness was checked on treated dentin surface and fractured dentin surface in 10 specimens respectievly. Francture modes were observed with SEM The following results were obtained. 1. Before thermocycling. shear bond strengths in the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND were significantly higher than those in other specimens(P<0.01). 2. After thermocycling. shear bond strengths in the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2 and DENTIN CONDITIONER and PRIMER A, B of AIL BOND were significantly higher than those in specimens not: treated, treated with GC-DENTIN CONDITIONER and 10-3 solution of 4-Meta(P<0.01). Shear bond strengths in the specimens treated with GC-DENTIN CONDITIONER and PRIMER A, B of ALL BOND were significantly higher than those in other specimens except those treated with Scotchprep of Srotchbond 2(P<0.01). 3. Shear bond strengths after thermocycling were reduced in the specimens not treated, treated with GC-DENTIN CONDITIONER and 10-3 solution of 4-Meta and were increased in the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2, without significance, compared with those before thermocycling. In the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND, shear bond strengths after thermocycling were significantly increased, compared with those before thermocycling(P<0.01). 4. Microhardnesses in the fractured surfaces after shear bond strength measurement were significantly increased in the specimens treated with 10-3 solution of 4-Meta and significantly decreased in the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND, compared with those in the treated dentin surfaces(P<0.01). 5. In the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2 and DENTIN CONDITIONER and PRIMER A, B of ALL BOND, cohesive fracture modes were observed more than adhesive fracture modes.

  • PDF

DENTIN BONDING AGENTS들의 상아세관 밀봉 효과에 관한 연구 (STUDY ON DENTINAL TUBULES SEALING EFFECTS OF DENTIN BONDING AGENTS)

  • 권오택;박동수
    • Restorative Dentistry and Endodontics
    • /
    • 제18권2호
    • /
    • pp.483-496
    • /
    • 1993
  • Dentin hypersensitivity medicaments such as Gluma, Scotchbond 2, All-Bond 2, which are resin adhesives, were used to compare the sealing effects of dentinal tubule under mechanical stress. Topical application of above medicaments on the dentin surfaces of extracted teeth followed by artificial tooth brushing for 6 weeks was performed for the comparison. The following conclusions on the degree of dentinal tubule exposure versus time by were reached by using polyvinyl siloxane impression material for taking the impression, epoxy resin for the duplication and SEM for observing the surface. 1. SEM was used to compare the accuracy of the duplicated surface, but no differences were found when teeth samples and the duplicated surfaces were observed. 2. After comparing the degree of dentinal tubules exposure with varnish applied contrast group, resin adhesive materials showed much less exposure as time went by. 3. The results indicated that AU-Bond 2 adhesive, under mechanical stress, showed lesser exposure of dentinal tubules comparing with Gluma and Scotchbond 2 adhesives After the results were put together, it was demonstrated that resin replica method is an useful way to evaluate the treatment effects of the dentinal tubule hypersensitivity medicaments. Also, it was noticed that under mechanical stress, All-Bond 2, classified as fourth generation, illustrated the best dentinal tubules sealing effects.

  • PDF

Bonding of a resin-modified glass ionomer cement to dentin using universal adhesives

  • Ugurlu, Muhittin
    • Restorative Dentistry and Endodontics
    • /
    • 제45권3호
    • /
    • pp.36.1-36.10
    • /
    • 2020
  • Objectives: This study aims to assess the effect of universal adhesives pretreatment on the bond strength of resin-modified glass ionomer cement to dentin. Materials and Methods: Fifty caries-free human third molars were employed. The teeth were randomly assigned into five groups (n = 10) based on dentin surface pretreatments: Single Bond Universal (3M Oral Care), Gluma Bond Universal (Heraeus Kulzer), Prime&Bond Elect (Dentsply), Cavity Conditioner (GC) and control (no surface treatment). After Fuji II LC (GC) was bonded to the dentin surfaces, the specimens were stored for 7 days at 37℃. The specimens were segmented into microspecimens, and the microspecimens were subjugated to microtensile bond strength testing (1.0 mm/min). The modes of failure analyzed using a stereomicroscope and scanning electron microscopy. Data were statistically analyzed with one-way analysis of variance and Duncan tests (p = 0.05). Results: The surface pretreatments with the universal adhesives and conditioner increased the bond strength of Fuji II LC to dentin (p < 0.05). Single Bond Universal and Gluma Bond Universal provided higher bond strength to Fuji II LC than Cavity Conditioner (p < 0.05). The bond strengths obtained from Prime&Bond Elect and Cavity Conditioner were not statistically different (p > 0.05). Conclusions: The universal adhesives and polyacrylic acid conditioner could increase the bond strength of resin-modified glass ionomer cement (RMGIC) to dentin. The use of universal adhesives before the application of RMGIC may be more beneficial in improving bond strength.

상아질 접착제의 상아세관 밀봉지속효과에 관한 연구 (A STUDY OF THE DURABILITY OF DENTINAL TUBULE SEALING EFFECTS OF DENTIN BONDING AGENTS)

  • 김의성;박동수
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.180-193
    • /
    • 1994
  • The purpose of this study was to observe the sealing ability and durability of All-Bond 2, Gluma Bonding System, Scotch bond 2 and Superbond D-liner which are dentin bonding agents used as desensitizing agents. The durability of the sealing ability of the materials were compared after 0, 140, 420, 840 tooth brushing strokes. 120 extracted teeth were divided into 5 groups and the agents were applied to the exposed dentin. No agents was applied on group I, the control group. Each specimen went through thermocycling from $5^{\circ}$ to $55^{\circ}C$, 200 times. Each group was devide into 4 subgroups and artificial tooth brushing strokes were done for 0, 140, 420, 840 times. Finally the specimens were stored in 0.5 % methylene blue solution for 24 hours in a incubator set at $37^{\circ}C$. The tooth were sectioned perpendicular to the long axis and the dye penetration ratio to the pulp was measured. The following results were obtained. 1. All four dentin bonding agents initially showed excellent sealing ability. 2. All-bond 2, Gluma Bonding System and Superbond D-liner showed durability of dentinal tubule sealing effect after 840 strokes(6-week) artificial tooth brushing. 3. Scotchbond 2 showed a significant decrease in sealing ability after 420 strokes(3-week) artificial tooth brushing. (P<0.05).

  • PDF

상아세관 폐쇄에 대한 2종의 상아질 지각 과민 체치제와 Er,Cr:YSGG 레이저의 효과 (Effect of two dentin desensitizers and Er,Cr:YSGG laser for dentinal tubule occlusion)

  • 김나송;강정경;류재준
    • 대한치과의사협회지
    • /
    • 제48권6호
    • /
    • pp.469-477
    • /
    • 2010
  • The purpose of this study was to evaluate the effect of two dentin desensitizers and Er,Cr:YSGG laser for dentinal tubule occlusion. Twenty recently extracted single-rooted human teeth were used to obtain root dentinal fragments. The crowns were cut approximately 1mm below the cementum enamel junction(CEJ). A second cut was used to remove the apex of the root. Subsequently, a longitudinal cut was made in order to obtain 2 fragments from each root sample. The cementum from the cervical portion was removed using a high-speed diamond-coated bur in order to expose the dentin. To open dentinal tubules, forty samples were treated with 50% citric acid for 2 min and then rinsed under distilled water for 1 min. These were divided into four groups of ten samples each. The first group served as a control group. In group 2, the samples were irradiated with the Er,Cr:YSGG laser(Waterlase MD, Biolase, USA). In group 3, the samples were treated with Bisblock and ONE-STEP PLUS(Bisco, USA). In group 4, the samples were treated with Gluma comfort bond & Desensitizer(Heraeus Kulzer, Germany). All the samples were examined using Scanning electron microscopy(Hitachi, S-4700, Japan) with two different magnifications(X2000, X5000). These images were assessed by one examiner who was blind to the experimental procedure, using the index of smear layer removal. The distribution of smear layer removal grades was tested using Fisher's exact test. On the order hand, in order to evaluate the occluding effect of two dentin desensitizers and Er,Cr:YSGG laser, the number of exposed dentinal tubules was counted in each group. These were evaluated using the Kruskal-Wallis test with significance predetermined $\alpha$=0.05. There were statistically significant differences between the three groups(Er,Cr:YSGG laser, Bisblock+ONE-STEP PLUS, Gluma comfort bond & Desensitizer) and control group.

Effect of rewetting agent on dentinal microtensile bond strength

  • Kang, Hee-Young;Cho, Young-Gon
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.568-568
    • /
    • 2003
  • I. Objectives This study investigated the effect of rewetting agent on dentinal microtensile bond strengths(${\mu}TBS$), using one bottle adhesives. II. Materials and Methods Non caries human molars were sectioned to exposed the superficial dentin surfaces, etched 15 seconds using 32% phosphoric acid and 10 seconds rinsed. Samples were randomly divided into two groups according to adhesives (Single Bond, One-Step) used. Each group were subdivided into five groups by different dentin surface treatment:15 second dry(D), blot dry(BD) or 15 second dry and rewetted with distrilled water(DW), Gluma Desensitizer(GD) and Aqua-Prep(AP) during 30 second, respectively.(omitted)

  • PDF

상아질 지각과민 측정 도구로서의 전기치수검사에 대한 평가 (Evaluation of Electric Pulp Test (EPT) as a Tool for Measurement of Dentinal Hypersensitivity)

  • 김영성
    • Journal of Periodontal and Implant Science
    • /
    • 제32권2호
    • /
    • pp.371-378
    • /
    • 2002
  • 이번 연구에서는 19명 환자의 40개 상아질 지각과민 치아를 조사하였다. 지각과민증을 평가하기 위하여 기계, 온도 및 전기적 자극을 사용하였다. 상아질 지각과민증의 치료제로는 Gluma(R) Desensitizer (Heraeus Kulzer GmbH & Co., Germany)를 사용 하였다. 연구 방법은 다음과 같다: 지각과민증의 치료 전에 협면의 치관 $\frac{1}{3}$ 부위에서 전기치수검사를 시행하여 치수 생활력을 조사하였고, 그 측정치를 기록하였다. 그리고 기계 및 온도 자극을 이용한 검사를 시행하여 지각과민증의 유무를 확인하였다. 지각과민증이 존재함을 확인한 후에 지각과민증의 마모부에서 전기치수검사를 실시하였다. 치약을 전해질로 사용하였고 반응시의 숫자를 기록하였다. 이후 Gluma(R) Desensitizer를 이용하여 지각과민증을 치료하였다. 치료 후 마모 부위에서 기계, 온도 및 전기 검사를 다시 실시하고 그 결과를 기록하였다. 기계 및 온도 자극에 대해 40개 치아 모두에서 지각과민증 치료 전에는 반응을 보였으며 치료 후에는 반응을 보이지 않았다. 치관 $\frac{1}{3}$ 부위에서 전기치수검사를 실시하였을 때 모든 치아는 31에서 65 (48.9${\pm}$7.2)의 범위에서 반응하였다. 상아질 지각과민증의 치료 전에 전기치수검사를 실시하였을 때 34개의 치아는 2에서 반응하였고 나머지 6개의 치아는 17에서 25 범위에서 반응하였다. 치료 후에는 40개 치아 모두가 12에서 27 (19.6${\pm}$3.5)의 범위에서 반응하였다. 치료 전에 2보다 큰 숫자에서 반응을 보인 여섯개의 치아는 18에서 23의 범위에서 반응하였다. 이번 연구의 범위 내에서 다음과 같은 결론을 도출할 수 있다. 상아질 지각과민증을 보이는 치아가 기계 및 온도 자극에 반응을 보인다면 그 치아는 마모된 면에서 낮은 전기저항을 보인다. 반면 상아질 지각과민증을 치료하여 기계 및 온도 자극에 반응하지 않는다면 그 치아는 마모면에서 증가된 전기저항을 보인다. 전기치수검사는 상아질 지각과민의 진단에 활용될 수 있다. 나아가 전기치수검사는 상아질 지각과민증의 치료 결과를 평가하는 데 유용할 것이다. 하지만 전기치수검사는 상아질 지각과민을 측정하는 데에는 적절하지 못하다.

수종 상아질 접착제의 상아질과의 접합양상에 관한 주사 전자현미경적 연구 (ADAPTATION OF COMPOSITE RESIN TO DENTINAL WALL USING DENTIN BONDING AGENTS)

  • 오원만;양규호;레치 오쿠다;히로미 사사자키;마사 코마츠
    • Restorative Dentistry and Endodontics
    • /
    • 제19권2호
    • /
    • pp.641-654
    • /
    • 1994
  • This study was executed to evaluate adaptability of dentin bonding agents to dentinal wall with measuring contraction gap on interface between cavity wall and composite resin by SEM study. 6 kinds of dentin bonding agents were investigated for this study : Gluma, Super Bond C & B, All bond 2, Scotchbond multipurpose, Scotchbond 2 and Clearfil photo bond. 30 of fresh extracted teeth were randomly selected and divided into 6 groups with each 5. The round shaped cavities with 3mm dia. and 1.5mm depth were prepared on cementoenamel junction of buccal surface of teeth. Dentin bonding agents were applied to cavity wall and then the composite resin was filled in the cavity. Specimens were sectioned longitudinally on buccal surface. Sectioned aspects of specimens were impressioned with rubber base materials and finally precise replica were made of epoxy resin poured in negative impression. Contraction gaps were examined on interface between cavity wall and composite resin under condition of 200 and 2000 magnification of SEM. The results were as follows. 1. There were no gap on interface between enamel and composite resin in all specimens, but gaps were mainly exhibited on apical side of lateral wall of dentin of cavity. 2. In Gluma, 2 cases of 5 specimens exhibited excellent adaptation to the cavity wall, indicating no gaps on interface between cavity wall and composite resin. The other specimens showed gaps with range of $0{\sim}15{\mu}m$ width. 3. In Super Bond C & B, gaps with range of $0{\sim}10{\mu}m$ width were mainly exhibited on apical side of lateral wall of dentin of cavity. 4. In All bond 2, all specimens showed the most exellent adaptation to cavity wall when compared to the other materials, indicating no gap interface between cavity wall and composite resin. 5. In Scotchbond multipurpose, gaps with range of $0{\sim}10{\mu}m$ width were locally located on cavity wall. 6. In Scotchbond 2, all specimens showed great amount of gap with range of $5{\sim}25{\mu}m$, indicating the worst adaptation to cavity wall compared to the other materials. 7. In Clearfil photo bond, 2 case of 5 specimens exhibited exellent adaptation to cavity wall, indicating no gap. the other specimens showed gap with range of $0{\sim}15{\mu}m$ width on inferface between cavity wall and composite resin.

  • PDF

상아질 지각과민 처치제의 적용 중에 일어나는 상아세관액 유동의 실시간 측정 (Real-time measurement of dentinal fluid flow during desensitizing agent application)

  • 김선영;김은주;이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제35권5호
    • /
    • pp.313-320
    • /
    • 2010
  • 연구목적: 본 연구의 목적은 미세 유체 흐름 측정장치를 이용해서 각 상아질 지각과민 처치제의 적용 과정 중 발생하는 상아 세관액 흐름의 유동을 관찰하고, 상아질 지각과민 처치제 간 적용 후 투과도 감소의 차이를 비교하고자 하는 것이다. 연구 재료 및 방법: CEJ 5 mm 하방에서 절단한 소구치를 미세 흐름 측정장치에 연결하여 20 cm $H_2O$의 정수압을 가하였다. 치경부에 상하 3 mm, 근원심 4 mm, 깊이 2 mm의 V자 형태의 5급 와동을 형성하고 smear layer를 제거하기 위해 15초 동안 산 부식한 후 상아질 지각과민 처치제를 적용하였다. 사용된 상아질 지각과민 처치제는 Seal&Protect (SP), SuperSeal (SS), BisBlock (BB), Gluma desensitizer (GL), Bifluoride 12 (BF) 이다. 상아세관액의 흐름은 지각과민 처치제 도포 전부터 도포 후 5분까지 실시간으로 측정되었다. 결과: 실험에 사용한 모든 상아질 지각과민 처치제는 적용 후의 상아세관액 흐름율이 적용 전에 비해 유의하게 감소하였다(p < 0.05). SP는 GL과 BF에 비해 유의하게 투과도 감소가 나타났다 (p < 0.05). SS와 BB는 BF에 비해 유의하게 투과도 감소를 보였다 (p < 0.05). 결론: 지각과민 처치제의 도포 과정 동안 각 처치제의 특징적인 상아세관액의 유동을 미세 유체 흐름 측정장치를 통해 관찰 할 수 있었다.

상아질 결합제의 L929 세포 독성에 관한 연구 (CYTOTOXICITY OF DENTIN BONDING SYSTEM ON L929 CELLS)

  • 임미경;지정호;김상섭
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.209-219
    • /
    • 1997
  • The research of the dentin bonding system was mainly on the chemistry and bonding strength. And in vitro assessement of biocompatibility of dentin bonding system was not completely developed. The purpose of this study was to evaluate the cytotoxic effect of several dentin primers. Scotchbond Multi-Purpose (3M Dental Products. USA). Gluma (BayerDental. Germany). All-Bond (Bisco. USA). ProBond (CaulkDensply, USA) and VeridonFil (Dongyang Nylon. Korea) were included. Cytotoxicity was tested using MTT cell viability test. 0.5 ul. 1 ul. 2 ul and 10 ul of each primer were added to the 96 well plate of incubated L929 cell lines. After 30-minute. 1. 4. 24 and 72-hour exposures. absorbance of L929 cells was observed with ELISA reader. All data were analyzed using t-test. All primers showed cytotoxicity on L929 cells under every conditions used in this study. Absorbance of L929 cells was decreased by time. Scotch bond group exhibited the lowest absorbance value in all exposure time and value.

  • PDF