• Title/Summary/Keyword: Glow Curve

Search Result 91, Processing Time 0.027 seconds

Luminescence properties and compositions of contaminating inorganic minerals separated from gamma-irradiated fresh and white ginsengs from different areas

  • Ahn, Jae-Jun;Akram, Kashif;Jeong, Mi-Seon;Kwak, Ji-Young;Park, Eun-Joo;Kwon, Joong-Ho
    • Journal of Ginseng Research
    • /
    • v.37 no.4
    • /
    • pp.483-490
    • /
    • 2013
  • Gamma-irradiation (0-7 kGy) of ginseng is permitted in Korea for the purpose of microbial decontamination; with strict labeling, traceability and monitoring requirements. An identification study was conducted to determine the photostimulated-luminescence (PSL) and thermoluminescence (TL) properties of gamma-irradiated fresh and white ginsengs cultivated in different areas. Dose- dependent PSL-based screening was possible for white ginseng samples; however, inappropriate results from non-irradiated fresh ginseng samples were obtained, showing intermediate (700 to 5,000) or positive ($T_2$ >5,000, irradiated) PSL counts due to the abundance of minerals on the surfaces of the samples. TL analysis of separated minerals from all non-irradiated samples gave TL glow curves of low intensity with a maximum peak after $300^{\circ}C$. However, well-defined irradiation-specific (high intensity with a maximum peak at about $200^{\circ}C$) glow curves were observed for all the irradiated samples, regardless of their type and origins. TL ratios (first glow curve /second glow curve) were also determined to confirm the irradiated (>0.1) and non-irradiated (<0.1) results. SEM-EDX (scanning electron microscope-energy dispersive X-ray) and XRD (X-ray diffraction) spectroscopic analyses showed that feldspar and quartz minerals were the main source for the typical radiation-specific luminescence properties.

The Use of Pulsed Photostimulated Luminescence (PPSL) and Thermoluminescence (TL) for the Detection of Irradiated Perilla and Sesame Seeds

  • Yi, Sang-Duk;Woo, Si-Ho;Yang, Jae-Seung
    • Preventive Nutrition and Food Science
    • /
    • v.5 no.3
    • /
    • pp.142-147
    • /
    • 2000
  • To establish a detection method of irradiated perilla and sesame seeds, studies were performed with pulsed photostimulated luminescence (PPSL) and thermoluminescence (TL). The PPSL photon counts of the mineral separated from irradiated sesame and perilla seeds were higher than unirradiated one and exhibited an increase with increasing irradiation dose and mineral content. Also TL intensities of minerals separated from irradiated sesame and perilla seeds increased with increasing irradiation dose. In all samples, detection was possible with shapes and maximum TL temperatures of the second glow curves showing lower regions than those of the first glow curves and correctly classified as irradiated samples. Glow curve ratios of irradiated samples were higher than 0.5. These results suggest that PPSL and TL are applicable methods for the detection of irradiated perilla and sesame seeds.

  • PDF

Thermoluminescence Kinetics of LYGBO Crystal (LYGBO 단결정의 열형광 전자포획준위 인자)

  • Sunghwan, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.17-23
    • /
    • 2023
  • In this study, the thermoluminescence kinetics of electron trap in Li6Y0.5Gd0.5(BO3)3 (LY0.5G0.5BO) scintillator for neutron detection composed of Li, Gd, and B with a high neutron response cross-section were investigated. The thermoluminescence glow curve of the LY0.5G0.5BO scintillation single crystal was measured and analyzed using the peak shape method, the initial rise method, and the machine learning algorithm to evaluate the physical parameters of the electron trap. The glow curve of the LY0.5G0.5BO scintillation single crystal consisted of a single peak. As a result of analyzing this peak, the activation energy, emission order, and frequency factor of the electron trap were 0.61 eV, 1.1, and 1.7×107 s-1, respectively. In addition, the possibility of thermoluminescence analysis of scintillators using machine learning was confirmed.

A Study on Fabrication and Characteristics of $CaSO_4:Tb$ TLD ($CaSO_4:Tb$ TLD의 제작과 특성에 관한 연구)

  • Park, Myeong-Hwan
    • Journal of radiological science and technology
    • /
    • v.22 no.1
    • /
    • pp.55-60
    • /
    • 1999
  • In this study, the highly sensitive $CaSO_4:Tb$ glass capsule type TLDs are fabricated and their trap parameters are determined. The optimum conditions of fabricating of $CaSO_4:Tb$ phosphor was obtained to be in impurity concentration of Tb 1.0 mol% and sintering of $600^{\circ}C$, 2 hr. The glow curve of $CaSO_4:Tb$ consists of three glow peaks and these peaks are isolated by thermal bleaching method. Activation energy of the three glow peaks measured by the initial rise, the peak shape and the heating rate method are 0.70, 0.87, and 1.03 eV. The frequency factors are $1.76{\times}10^9,\;1.74{\times}10^9$, and $9.77{\times}10^8\;s^{-1}$, and the kinetic orders are 1.12, 1.46, and 1.34, respectively. The isolated glow peaks are fitted by least square method and optimum temperature range of the main peak for radiation dosimetry is $230{\sim}295^{\circ}C$.

  • PDF

TLD's Glow Curve and Radiation Exposure Amount Analysis at Environment with/without Magnetic Field Exposure as Time Passing (시간 경과에 따른 자기장 노출 유·무 환경에서 열형광선량계의 글로우 곡선 및 피폭 방사선량 분석)

  • Lee, Jae-Heon;Ko, Seong-Jin;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.419-426
    • /
    • 2016
  • The research is done to analyze the change of personal dosimeter according to the elapsed times(24 hours, 1 week, 2 weeks, 3 weeks, 4 weeks) and magnetic field and find out the effective exposure treatment for radiation workers. At first, research the heat treatment and radiation of grouped TLD and keep them in different environments-exposed separately to observe the consequences of glow curve and the level of radiation exposure. As a result, we could find that 24 hours passing TLD group showed the difference in glow curve and the level of radiation. This can be considered as the change caused by magnetic exposure. Also the average radiation exposure level of TLD group, unexposed to the magnetic field, was 15.41 mSv. And the average radiation exposure level of TLD group, exposed to the magnetic field, was 14.83 mSv which decreased the biggest amount(3.80%) among the other groups. If a radiation worker, who works in PET-MRI room, uses TLD as a personal dosimeter, the level of real radiation exposure caused by exposure to the magnetic field won't change significantly as recorded at a regular record cycle but with not regular record but interim record, the lower exposure dose will be appeared than the real level of radiation.

Defect center of $Li^{+}$ ion implanted $Al_2O_3$ ($Li^{+}$ 이온 주입된 $Al_2O_3$의 결함 특성)

  • Kim, Tae-Kyu
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.13-20
    • /
    • 1994
  • The thermoluminescence(TL) glow curves and the optical absorption of $Al_2O_3$ irradiated with ${\gamma}$-ray, electron, and $Li^{+}$ ion followed by electron irradiation have been investigated to determine the relation of TL peak to its defect type. The TL glow curve of $Al_2O_3$ irradiated with ${\gamma}$-ray shows TL peaks at 380 K, 415 K, and 475 K. The UV photobleached TL glow curve of $Al_2O_3$ irradiated with ${\gamma}$-ray shows that the 380 K and 475 K TL peaks completely disappear while the 415 K TL peak still exists. The electron beam induced TL glow curve of $Al_2O_3$ after $Li^{+}$ ion implantation shows that the TL peak at 440 K is enhanced by a factor of 2 over the TL intensity of unimplanted $Al_2O_3$ while the TL peak at 380 K evidently disappears The implanted $Li^{+}$ ions are assumed to form singly charged interstitial cations and then recombine with electron trapped in F centers to produce F+ centers. The 380 K and 475 K TL peaks are proposed to be associated with F center, while the 415 K and 440 K TL peak are connected with F$^{+}$ center.

  • PDF

Analyzing a Physical Marker to Identify Irradiated Dried Garlic and Cabbage (건마늘과 건양배추의 방사선 조사여부 확인을 위한 물리적 마커 분석)

  • Kim, Dong-Gil;Ahn, Jae-Jun;Jin, Qiong-Wen;Lee, Ho-Cheon;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.136-140
    • /
    • 2009
  • The verification of irradiation treatments, using dried garlic and cabbage treated at 0-20 kGy, was investigated by analyzing the photostimulated luminescence (PSL), electron spin resonance (ESR) and thermoluminescence (TL) characteristics of the samples. The PSL results showed that the photon counts/60 sec of the non-irradiated dried garlic and cabbage were 287-337, corresponding to negative, while those of the irradiated samples were 7511-54063 photon counts/ 60 sec, corresponding to positive, making it possible to discriminate the non-irradiated from the irradiated samples. In ESR analysis, the dried garlic irradiated at 20 kGy exhibited cellulose radicals, whereas the irradiated dried cabbage showed crystalline sugar-induced multi-component signals, which were not found in the non-irradiated samples. The ESR signal intensity significantly increased as the irradiation dose increase ($R^2$= 0.9369 - 0.9926). The TL glow curves of the irradiated samples appeared at a temperature interval of 150-250, which were significantly different from those of non-irradiated samples, showing a significant increase in TL signal intensity with irradiation dose ($R^2$= 0.9670 - 0.9768). To enhance the reliability of the results, the first glow curve ($TL_1$) was compared with the second glow curve ($TL_2$) obtained after a re-irradiation step at 1 kGy. The TL ratio ($TL_1/TL_2$) was in good agreement with the reported TL threshold values for both the non-irradiated (<0.1) and irradiated (> 0.1) samples.

Application of PSL and TL Detection Method by Irradiation doses on the Foods Approved to Irradiation in Korea (조사 선량에 따른 품목별 PSL과 TL 시험법 적용 가능성 검증)

  • Cho, Joon-Il;Lee, Ji-Ae;Chung, Hyung-Wook;Lee, Soon-Ho;Hwang, In-Gyun
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.1
    • /
    • pp.43-48
    • /
    • 2010
  • This research was conducted to know application of Photostimulated luminescence (PSL) and Thermoluminesce(TL) methods by irradiation dose for leaching tea, sauces and starch approved in Korea. Leaching tea, sauces and starch powder were treated with $^{60}Co$ gamma ray at dose 0~10 kGy for detection trial whether they are irradiated or not by measuring PSL and TL for whole samples. PSL values were less than threshold value 700 and were, negative for non-irradiated samples but more than 5,000 and were positive for irradiated ones. PSL results of leaching tea and sauces showed the correct identification for non-irradiated and irradiated samples, respectively except starch samples. To enhance the reliability of the TL result, the first glow curve (TL1) was compared with the second glove curve (TL2) obtained after a re-irradiation step at 1 kGy. The TL ratio ($TL_1/TL_2$) was in good agreement with the reported TL threshold for both the non-irradiated (< 0.1) and irradiated (> 0.1) samples. TL results of leaching tea, sauces, starch showed the correct identification for non-irradiated and irradiated samples, respectively. This study was performed to know application of PSL and TL methods for leaching tea, sauces and starch, and the methods were able to detect the irradiation products.

A Study on Composition and Dosimetry of the $CaSO_4$ Phosphors ($CaSO_4$ 열형광체의 조성과 선량측정에 관한 연구)

  • Lee, Duek-Kyu
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.59-64
    • /
    • 1998
  • [ $CaSO_4$ ] thermoluminescent phosphors was made by sintring the $CaSO_4$ after doping the transition elements Tm, Pd, Dy, V, Mo, Zr. The maximum Peaks are found in the measured $CaSO_4$(Tm, Pd, Dy, V, Mo, Zr) TL glow curve at $130^{\circ}C,\;110^{\circ}C,\;140^{\circ}C,\;100^{\circ}C$, and $120^{\circ}C$ when the heating rate is $5^{\circ}C/sec$. The activation energy of the main peak has been estimated by the peak shape method. The estimated activation energies are 1.02eV, 1.32eV, 1.12eV, 0.80eV, and 1.17eV, respectively. The thermoluminescence process in $CaSO_4$(Tm, Pd, Dy, V, Mo, Zr)are found to the 2nd order when the main peak of the glow curve is analyzed by peak shape method. The dose responses of $CaSO_4$(Tm, Pd, Dy, V, Mo, Zr) phosphors are linear within $4{\times}10^{-4}{\sim}1Gy$ of X-rays.

  • PDF

The Electron Trap Analysis in Thermoluminescent LiF Crystal

  • Park, Dae-Yoon;Ko, Chung-Duck;Lee, Sang-Soo
    • Nuclear Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.214-222
    • /
    • 1972
  • In the optic,11 grade LiF crystal, the electron traps corresponding to the thermoluminescence(abbreviated to TL) glow peak develop as irradiation dose is increased. Originally the electron trap of the crystal has two levels but as the dose reaches to the order of 10$^4$rontgen, it attains five levels as observed in the TL glow curves. The five trap depths are determined from the glow peak temperatures for two different heating rates, $\theta$=6.6$^{\circ}C$/sec and 3.4$^{\circ}C$/sec. The electron trap depths have the following values E$_1$=0.79 eV, E$_2$=0.93 eV, E$_3$=1.02 eV, E$_4$=1.35 eV, E$_{5}$=1.69eV. The special feature of thermoluminescence of optical grade LiF is that the traps, except E$_1$and E$_2$corresponding to 12$0^{\circ}C$ glow peak and 15$0^{\circ}C$ glow peak for $\theta$=6.6$^{\circ}C$/sec, have severe thermal instability, namely E$_3$, E$_4$and E$_{5}$ levels disappear during bleaching process. These defects in the optical grade LiF crystal seem annealed out during the course of TL measurement. The fresh or long time unused LiF(Mg) crystal shows only two glow peaks at 17$0^{\circ}C$ and 23$0^{\circ}C$ for $\theta$=6.6$^{\circ}C$/sec, but upon sensitization with r-ray irradiation, it converts to the six glow peak state. The four electron traps, E$_1$, E$_2$, E$_3$, and E$_{6}$ created by r-ray irradiation and corresponding to the glow peaks at T=10$0^{\circ}C$ 13$0^{\circ}C$, 15$0^{\circ}C$ and 29$0^{\circ}C$ are stable and not easily annealed out thermally, The sensitization essentially required to LiF(Mg) dosimeter is to give the crystal the stable six levels in the electron trap. In optical grade LiF, the plot between logarithm of total TL output versus logarithm of r-ray dose gives more supra-linear feature than that of LiF(Mg). However, if one takes the height of 12$0^{\circ}C$ glow peak(S=6.6$^{\circ}C$/sec), instead of the total TL output, the curve becomes close to that of LiF(Mg).

  • PDF