• Title/Summary/Keyword: Glomerular Filtration Rate (GFR) test

Search Result 19, Processing Time 0.022 seconds

Comparative analysis of Glomerular Filtration Rate measurement and estimated glomerular filtration rate using 99mTc-DTPA in kidney transplant donors. (신장이식 공여자에서 99mTc-DTPA를 이용한 Glomerular Filtration Rate 측정과 추정사구체여과율의 비교분석)

  • Cheon, Jun Hong;Yoo, Nam Ho;Lee, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.35-40
    • /
    • 2021
  • Purpose Glomerular filtration rate(GFR) is an important indicator for the diagnosis, treatment, and follow-up of kidney disease and is also used by healthy individuals for drug use and evaluating kidney function in donors. The gold standard method of the GFR test is to measure by continuously injecting the inulin which is extrinsic marker, but it takes a long time and the test method is complicated. so, the method of measuring the serum concentration of creatinine is used. Estimated glomerular filtration rate (eGFR) is used instead. However, creatinine is known to be affected by age, gender, muscle mass, etc. eGFR formulas that are currently used include the Cockroft-Gault formula, the modification of diet in renal disease (MDRD) formula, and the chronic kidney disease epidemilogy collaboration (CKD-EPI) formula for adults. For children, the Schwartz formula is used. Measurement of GFR using 51Cr-EDTA (diethylenetriamine tetraacetic acid), 99mTc-DTPA (diethylenetriamine pentaacetic acid) can replace inulin and is currently in use. Therefore, We compared the GFR measured using 99mTc-DTPA with the eGFR using CKD-EPI formula. Materials and Methods For 200 kidney transplant donors who visited Asan medical center.(96 males, 104 females, 47.3 years ± 12.7 years old) GFR was measured using plasma(Two-plasma-sample-method, TPSM) obtained by intravenous administration of 99mTc-DTPA(0.5mCi, 18.5 MBq). eGFR was derived using CKD-EPI formula based on serum creatinine concentration. Results GFR average measured using 99mTc-DTPA for 200 kidney transplant donors is 97.27±19.46(ml/min/1.73m2), and the eGFR average value using the CKD-EPI formula is 96.84±17.74(ml/min/1.73m2), The concentration of serum creatinine is 0.84±0.39(mg/dL). Regression formula of 99mTc-DTPA GFR for serum creatinine-based eGFR was Y = 0.5073X + 48.186, and the correlation coefficient was 0.698 (P<0.01). Difference (%) was 1.52±18.28. Conclusion The correlation coefficient between the 99mTc-DTPA and the eGFR derived on serum creatinine concentration was confirmed to be moderate. This is estimated that eGFR is affected by external factors such as age, gender, and muscle mass and use of formulas made for kidney disease patients. By using 99mTc-DTPA, we can provide reliable GFR results, which is used for diagnosis, treatment and observation of kidney disease, and kidney evaluation of kidney transplant patients.

Glomerular Filtration Rate Test Methods and Guidelines (Glomerular Filtration Rate 검사방법 및 가이드라인)

  • Park, Min-Ho;Lee, Ha-Young;Ryu, Hwa-Jin;Yoo, Tae-Min;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.97-100
    • /
    • 2018
  • Purpose The glomerular filtration rate (GFR) test is an important indicator of glomerular filtration and has been used to test renal function and the extent of its function. The GFR test is performed by intravenous injection of radioactive medicines made of $^{51}Cr$-EDTA, and blood concentration is measured by taking blood according to the elapsed time. also, PET-CT, bone scan, transfusion and so on will affect the outcome. Therefore, we will improve the quality of the test by providing guidelines for the GFR test for more accurate testing. Materials and Methods 5 mL of physiological saline solution and 2 mL of $^{51}Cr$-EDTA solution are used to make 5 mL of the radiopharmaceutical solution to be injected into the patient. First, the syringe weight is measured before the injection, and then the radioactive medicine is injected into the patient's vein and the syringe weight is measured after the injection. Blood sampling is performed twice in total. In adults, blood is collected 3 hours / 5 hours after injection and in children 2 hours / 5 hours after injection. The blood sample is centrifuged at 3300 rpm for 5 minutes. Standard solution is prepared by filling diluent water up to the scale indicated in the 200-mL volumetric flask, discarding $500{\mu}L$, injecting $500{\mu}L$ of GFR reagent and mixing well. $500{\mu}L$ each of the standard solution is dispensed into two test tubes, and $500{\mu}L$ of each of the plasma samples collected in time is dispensed into two test tubes and measured with a Cobra Counter. Results At present, the reference range applied in this study is $119.5{\pm}30.3ml/min/1.73m2$ for males and $125.2{\pm}28.2ml/min/1.73m^2$ for females. Conclusion The GFR test is conducted using radioactive medical products. GFR testing is performed as a scheduled test, but PET-CT, dialysis and transfusion, which may affect GFR testing, may be scheduled during GFR testing. Therefore, we could get accurate GFR test results by notifying the ward and department beforehand when booking.

Evaluation of Validity Glomerular Filtration Rate Measured by Gates Method according Region of Interest (관심 영역 설정에 따른 Gates법 토리여과율의 유효성 평가)

  • Su-Young Park;Sung-Min Ahn
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.417-425
    • /
    • 2023
  • The glomerular filtration rate (GFR) has been the subject of much research as a key indicator for diagnosing, treating, and monitoring kidney function. The gamma camera method (Gates method) is simple and allows simultaneous acquisition of GFR and renal scintigraphy for each kidney, however its accuracy is inferior. This study aimed to investigate changes in GFR depending on how region of interest (ROI) are set up, which is one of many factors influencing accuracy. GFR was calculated by setting the ROI for each phase of the image acquisition time (Gates-1: 0~1 minutes, Gates-2: 1~3 minutes, Gates-3: 3~27 minutes), and statistical significance was verified based on probability value 0.05 through ANOVA analysis. While there was no statistically significant difference among results from Gates-1, 2, 3 (p=0.481>0.05), overall results from the Gates method tended to overestimate compared to those from the multiple blood sampling-dual exponential (MBSDE) method. When comparing averages between phases, results from Gates-2 were most similar to those from the MBSDE method. Moreover, paired t-test p-values between MBSDE method and phases were as follows Gates-1: 0.021 (p<0.05), Gates-2: 0.280 (p>0.05), and Gates-3: 0.164 (p>0.05) indicating that only Gates-1 had statistically significant differences compared with MBSDE method. Thus, setting ROI around 2~3 minutes is calculated can aid in accurately determining GFR when Gates Method.

A Study on How Height and Weight Affects Glomerular Filtration Rate (신장과 체중의 변화가 사구체 여과율에 미치는 영향)

  • Park, A Rang;Choi, Jong Sook;Lee, Young Hee;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.40-44
    • /
    • 2019
  • Purpose Glomerular filtration rate (GFR) is an important index for evaluation of renal function, renal disease diagnosis and progress monitoring. Therefore, accurate measurement of GFR is clinically important. Among the factors that affect the GFR result, there have been many discussions on the methods such as the correction of the kidney depth, net syringe count, and the method of setting the ROI. However there has been no consideration of counting in the most basic factors like height and weight measurement. In this study, we investigate how height and weight changes affects the result of GFR and review the importance of standardized body measurements. Materials and Methods Fifty patients who underwent GFR test were randomly sampled and examined for changes in height and body weight within one month. From the normal patients without renal disease to the patients with severely decreased GFR, we applied the GFR formula of Gate with varying height and weight. Results: The result showed variation of the height at maximum three centimeters and six kilograms of weight. The first calculation of GFR was done with fixed height value and control variable as weight. Weight was incremented by one kilogram each time up to six kilograms. The GFR showed increased result with increasing weight. The result of GFR showed ten percent increase with six kilograms of weight increase. On the other hand, when height value was incremented by one centimeter up to three centimeters showed decreased GFR result with fixed weight value. Up to three centimeters of height increase showed two percent of decreased GFR with fixed weight. Conclusion This study showed varying GFR result when height and weight changes. Therefore it is clinically crucial not only to maintain and manage body measuring instrument but also to have a standardized measurement methods to derive accurate measured values and to achieve reproducibility.

Relationship between the Estimated Glomerular Filtration Rate and the Urine Microalbumin/Creatinine Ratio and Ferritin in Korean Adults (한국 성인에서 사구체여과율 및 요 중 미세알부빈/크레아티닌 비율과 페리틴의 관련성)

  • Yoon, Hyun;Lee, Jun Ho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.145-154
    • /
    • 2019
  • This study examined the relationship between the estimated glomerular filtration rate (eGFR) and urine microalbumin/creatinine ratio (uACR) with ferritin in Korean adults. This study included 4,948 adults aged ${\geq}20years$ from the 2012 Korea National Health and Nutrition Examination Survey (KNHANES) data. A covariance test adjusted for covariates was performed for the ferritin levels in relation to the decreased eGFR (eGFR<$60ml/min/1.73m^2$) and elevated uACR ($uACR{\geq}30mg/g$). Several key findings were made in the present study. First, after adjusting for the related variables, the ferritin level was higher in the decreased eGFR group [$103.04{\pm}6.59mL/min/1.73m^2$; 95% confidence interval (CI), 90.12~115.96] than in the normal eGFR group ($84.87{\pm}1.16mL/min/1.73m^2$; 95% CI, 82.59~87.14; P=0.007). Second, after adjusting for the related variables, the ferritin level ($M{\pm}SE$) was similar in the normal uACR group ($85.70{\pm}1.20mg/g$; 95% CI, 83.35~88.05) and elevated uACR group ($82.72{\pm}4.09mg/g$; 95% CI, 74.71~90.73) (P=0.487). Chronic kidney disease was positively associated with the ferritin level in Korean adults but albuminuria was not.

Risk Factors for Cardiac Implantable Electronic Device-Related Infections (이식형 심장 모니터링 장치 관련 감염의 위험요인)

  • Park, Jin Yeong;Choi, Hye-Ran
    • Journal of Korean Biological Nursing Science
    • /
    • v.23 no.4
    • /
    • pp.298-307
    • /
    • 2021
  • Purpose: This study aimed to investigate the risk factors for cardiac implantable electronic device (CIED)-related infections within the first post-procedural year after CIED insertion. Methods: This study included 509 adult patients undergoing CIED implantation procedures between January 1, 2011 and December 31, 2015. The data were analyzed by t-test, chi-square test, Fisher's exact test, and logistic regression analysis using SPSS/WIN 23.0. Results: Fifteen infections and 494 non-infections were examined. The CIED-related infection rate was 2.9%; patients with 14 pocket infections and one bacteremia were included in the CIED-related infection. The risk factors of CIED-related infections were the estimated glomerular filtration rate (eGFR) of ≤ 45 mL/min/1.73 m2 (Odds ratio [OR]= 4.03, 95% confidence interval [CI],1.15-14.10) and taking a new oral anticoagulant (NOAC) (OR = 4.50, 95% CI 1.09-18.55). Conclusion: These results identified the CIED infection rate and risk factors of CIED-related infection. It is necessary to consider these risk factors before the CIED implantation procedure and to establish the relevant nursing interventions.

Risk of Fracture Prevalence and Glycemic Control in Korean Older and Middle-aged Patients with Diabetes: A Retrospective Analysis of a Cohort Derived from the Korean National Health Insurance Sharing Service Database, 2009-2013 (노인과 중년 당뇨병 환자의 골절의 발생 빈도 위험과 혈당조절의 관계)

  • Sin, Hye Yeon
    • Korean Journal of Clinical Pharmacy
    • /
    • v.28 no.3
    • /
    • pp.194-203
    • /
    • 2018
  • Background: Bone fractures are high in elderly patients with type 2 diabetes mellitus (T2DM). Hyperglycemia and chronic kidney disease may increase the risk of fracture prevalence via altered bone metabolism, but whether glycemic control and kidney function are associated with the risk of fracture prevalence remains unclear. This study evaluated the relationship between glycemic control and baseline estimated glomerular filtration rate (eGFR) and risk of fracture prevalence in older and middle-aged patients with T2DM. Methods: Patients who underwent a general medical check-up between 2009 and 2013 were selected from the Korean National Health Insurance Sharing Service records. Chi-square test and multiple logistic regression analysis were used to assess the relationship between glycemic control and eGFR and risk of fracture prevalence. Results: Cumulative fracture prevalence were higher in patients with T2DM, irrespective of whether they had tight or less stringent glycemic control (fasting blood glucose [FBG] ${\geq}110mg/dL$). After adjustment for baseline age and FBG, tight and less stringent glycemic control was significantly associated with increased adjusted risk of fracture prevalence in middle-aged patients with T2DM (OR=1.13, 95% CI, 1.05-1.21, p=0.0005 vs OR=1.13, 95% CI, 1.06-1.20, p=0.0001), but not in older patients. Baseline eGFR was not significantly related to fracture prevalence in either older or middle-aged patients. Conclusion: Less stringent glycemic control significantly increased the adjusted risk of fracture prevalence in middle-aged patients with T2DM. Further studies are needed to confirm the effect of tight glycemic control on fracture prevalence.

Optimization of GFR value according to Kidney Depth Measurement Methods (신장 Depth 측정 방법에 따른 GFR 값의 최적화)

  • Kwon, Hyeong-Jin;Moon, Il-Sang;Noh, Gyeong Woon;Kang, Keon Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.25-28
    • /
    • 2019
  • Purpose In patients with unusual kidney position after $^{99m}Tc-DTPA$ renal dynamic imaging study, the GFR(Glomerular Filtration Rate) values are significantly different according to the depth of the kidney. Thus, we tried to compare the difference of the GFR values between the depth measurement methods and in-vitro test. 30 adult patients who were subjected to renal study. 27 patients were in usual position and 3 patients were in unusual. $555{\pm}37MBq$ of $^{99m}Tc-DTPA$ was administrated to all patients. GE infinia gamma camera was used. GFR values were obtained in-vivo(gates method) and in-vitro(blood). The kidney depth in-vivo was calculated by three methods(tonnensen, manual, taylor). In-vitro, GFR was performed by blood test. Differences in the mean values of GFR and correlation between depth and GFR values were evaluated using the SPSS 12.0 statistical program. The GFR values for 27 patients with kidney in the usual position are as follows(1.tonnensen 2.manual 3.taylor 4.invitro); $69.3{\pm}4.2$, $88.2{\pm}5.6$, $77.8{\pm}4.3$, $82.2{\pm}5.8ml/min$. The three unusual cases are as follows, first(congenital renal anomaly): 66.4, 101.24, 69.07, 94.8 ml/min. second(transplantation kidney): 12.22, 29.99, 19.36, 23.5 ml/min. third(horseshoe kidney): 37.37, 93.54, 35.9, 92.5 ml/min. There was a difference between tonnensen and manual in the usual position of the kidney(p<0.05). There was no significant difference between the other methods. However, there was a significant difference in case of the unusual position of the kidneys. Correlation analysis between both kidney depth and GFR value shows person correlation as follows; Rt kidney: 0.298, Lt kidney: 0.322. When compared with the GFR values in-vitro test, it was useful to calculate the GFR value by measuring the kidney depth using a manual formula in the unusual position of the kidneys. GFR values and kidney depth were significantly related.

The Evaluation of Predose Counts in the GFR Test Using $^{99m}Tc$-DTPA ($^{99m}Tc$-DTPA를 이용한 사구체 여과율 측정에서 주사 전선량계수치의 평가)

  • Yeon, Joon-Ho;Lee, Hyuk;Chi, Yong-Ki;Kim, Soo-Yung;Lee, Kyoo-Bok;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.94-100
    • /
    • 2010
  • Purpose: We can evaluate function of kidney by Glomerular Filtration Rate (GFR) test using $^{99m}Tc$-DTPA which is simple. This test is influenced by several parameter such as net syringe count, kidney depth, corrected kidney count, acquisition time and characters of gamma camera. In this study, we evaluated predose count according to matrix size in the GFR test using $^{99m}Tc$-DTPA. Materials and Methods: Gamma camera of Infinia in GE was used, and LEGP collimator, three types of matrix size ($64{\times}64$, $128{\times}128$, $256{\times}256$) and 1.0 of zoom factor were applied. We increased radioactivity concentration from 222 (6), 296 (8), 370 (10), 444 (12) up to 518 MBq (14 mCi) respectively and acquired images according to matrix size at 30 cm distance from detector. Lastly, we evaluated these values and then substituted them for GFR formula. Results: In $64{\times}64$, $128{\times}128$ and $256{\times}256$ of matrix size, counts per second was 26.8, 34.5, 41.5, 49.1 and 55.3 kcps, 25.3, 33.4, 41.0, 48.4 and 54.3 kcps and 25.5, 33.7, 40.8, 48.1 and 54.7 kcps respectively. Total counts for 5 second were 134, 172, 208, 245 and 276 kcounts from $64{\times}64$, 127, 172, 205, 242, 271 kcounts from $128{\times}128$, and 137, 168, 204, 240 and 273 kcounts from $256{\times}256$, and total counts for 60 seconds were 1,503, 1,866, 2,093, 2,280, 2,321 kcounts, 1,511, 1,994, 2,453, 2,890 and 3,244 kcounts, and 1,524, 2,011, 2,439, 2,869 and 3,268 kcounts respectively. It is different from 0 to 30.02 % of percentage difference in $64{\times}64$ of matrix size. But in $128{\times}128$ and $256{\times}256$, it is showed 0.60 and 0.69 % of maximum value each. GFR of percentage difference in $64{\times}64$ represented 6.77% of 222 MBq (6 mCi), 42.89 % of 518 MBq (14 mCi) at 60 seconds respectively. However it is represented 0.60 and 0.63 % each in $128{\times}128$ and $256{\times}256$. Conclusion: There was no big difference in total counts of percentage difference and GFR values acquiring from $128{\times}128$ and $256{\times}256$ of matrix size. But in $64{\times}64$ of matrix size when the total count exceeded 1,500 kcounts, the overflow phenomenon was appeared differently according to predose radioactivity of concentration and acquisition time. Therefore, we must optimize matrix size and net syringe count considering the total count of predose to get accurate GFR results.

  • PDF

Suitability of Measuring a Kidney Depth with Assessment of Glomerular Filtration Rateusing 99mTc-DTPA in the Ectopic Kidney and Pediatric Patients (99mTc-DTPA를 이용한 사구체여과율 검사에서 이소성 신장과 소아 환자의 신장 깊이 측정방법의 적절성)

  • Choi, Jae Min;Lee, Young Hee;Shim, Dong Oh
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.62-67
    • /
    • 2014
  • A glomerular filtration rate (GFR) study is a test that uses radioactive materials or tracers (radiopharmaceuticals) and a computer to see how well the kidneys are working. Asan Medical Center analyzed and compared data between kidney depth, acquired from kidney donors' CT image and acquired from Gates method's GFR value that are calculated by Tonnesen equation. This study was able to confirm that kidney depth measured from CT image was higher than the Gates Method's GFR value, which was calculated by Tonnessen equation; the direct relationship among pathologic results is confirmed. Particularly, kidney donor whose kidney was at the pelvic area had direct relationship with other clinical results. During the GFR test, it is necessary to confirm the location of kidney has no change with reference of CT image. If kidney depth is manually corrected using CT image when we measures GFR of deformed or horse-shoe kidney, it would be possible to acquire the compatible value which is equivalent to clinical result. There would be a possible issue of appropriateness that whether the applied GFR using CT image's kidney depth has clinical validity. In case of a pediatric patient, the GFR derived from Tonnesen was quiet underestimated while manual method and Gordon stay in normal range. Which results may be correct among them? There have been many reports about kidney depth, to be an accurate index of GFR in children. As one of the study performers, we should contemplate what the best option for pediatric patients would be.

  • PDF