• Title/Summary/Keyword: Glomerular Filtration Rate

Search Result 225, Processing Time 0.024 seconds

Action of serot9ninon the renal function in the dog. (개의 신장기능(腎臟機能)에 대(對)한 Serotonin의 작용(作用))

  • Sub, Byoung-Chul
    • The Korean Journal of Pharmacology
    • /
    • v.2 no.1 s.2
    • /
    • pp.13-16
    • /
    • 1966
  • The action of serotonin (5-Hydroxytryptamine) on the excretory function of the kidney was investigated in the dog, utilizing the clearance method and the stop-flow technique. It was shown that serotonin, $10{\mu}g/kg/min$, i. v., exerts a marked antidiuretic effects and elicits a marked hemodynamic changes in the kidney: a highly significant decrease of the glomerular filtration rate and a tendency of decrement in the renal plasma flow. Little change in the systemic blood pressure was noted, and the participation of the antidiuretic hormone in the antidiuretic action was ruled out by adding vasopressin to the infusion fluid. The stop-flow analysis showed that there is no evidence of altered activity in the tubules by serotonin. It was thus concluded that serotonin elicits anti diuresis in the dog by decreasing glomerular filtration rate, which results from the constriction of Vas afferens in the glomeruli.

  • PDF

Effects of Sin Bee Tang Water Extract on the Renal Function, Arterial Blood Pressure and Plasma Cortisol Concentration in the Rabbit (신비탕(神秘湯) 전탕액(煎湯液)이 가토(家兎)의 신장기능(腎臟機能), 혈압(血壓) 및 혈장(血漿) Cortisol농도(濃度)에 미치는 영향(影響))

  • Chung, Jae-Woo;Han, Sang-Whan
    • The Journal of Internal Korean Medicine
    • /
    • v.10 no.1
    • /
    • pp.125-136
    • /
    • 1989
  • This study was investigated to clarify the effect of Sin Bee Tang (神秘湯) on the renal function, arterial blood pressure and plasma cortisol. The results obtained were follows; 1. Urine volume and glomerular filtration rate were decreased significantly after Sin Bee Tang water extract, 0.1ml/kg, administration. 2. Glomerular filtration rate, renal plasma flow and urinary excretion of electrolytes were increased significantly after Sin Bee Tang water extract, 0.25ml/kg, administration. 3. Plasma cortisol concentration increased significantly after Sin Bee Tang water extract, 0.25ml/kg, administration. These results suggest that the therapeutic action of Sin Bee Tang for 'Su Chun (水喘)' has a relation with the increase of plasma cortisol and renal hemodynamic effect.

  • PDF

Influence of Intraventricular Bethanidine on the Renal Function of the Rabbit (가토의 신장 기능에 미치는 측뇌실내 Bethanidine의 영향)

  • 고석태
    • YAKHAK HOEJI
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 1979
  • Bethanidine was administered into the lateral ventricle of the rabbit brain for the investigation of the effect on the renal function in doses ranging from 0.1 to 1.0mg/kg. In a dose of 0.1 mg/kg, bethanidine did not exhibit significant changes on the renal function of the rabbit, on the other hand, in the doses of 0.3 and 1.0mg/kg bethanidine elicited the reduction of renal plasma flow and glomerular filtration rate with a marked antidiuresis, at the same time bethanidine produced the decrement of urinary sodium and potassium excretion. After intravenous pretreatment of phentolamine, intraventricular bethanidine in a dose of 0.3mg/kg did not produced the antidiuresis and the decrement of urinary sodium and potassium excretion, wherease renal plasma flow and glomerular filtration rate reduced as before of phentolamine pretreatment although the durations of their reduction were shortened. These observations suggest that bethanidine induces the antidiuresis through the centrally mediated mechanism which interposed other factors in addition to sympathetic stimulation affected by phentolamine, alpha adrenergic blocking agent.

  • PDF

Evaluation of Validity Glomerular Filtration Rate Measured by Gates Method according Region of Interest (관심 영역 설정에 따른 Gates법 토리여과율의 유효성 평가)

  • Su-Young Park;Sung-Min Ahn
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.417-425
    • /
    • 2023
  • The glomerular filtration rate (GFR) has been the subject of much research as a key indicator for diagnosing, treating, and monitoring kidney function. The gamma camera method (Gates method) is simple and allows simultaneous acquisition of GFR and renal scintigraphy for each kidney, however its accuracy is inferior. This study aimed to investigate changes in GFR depending on how region of interest (ROI) are set up, which is one of many factors influencing accuracy. GFR was calculated by setting the ROI for each phase of the image acquisition time (Gates-1: 0~1 minutes, Gates-2: 1~3 minutes, Gates-3: 3~27 minutes), and statistical significance was verified based on probability value 0.05 through ANOVA analysis. While there was no statistically significant difference among results from Gates-1, 2, 3 (p=0.481>0.05), overall results from the Gates method tended to overestimate compared to those from the multiple blood sampling-dual exponential (MBSDE) method. When comparing averages between phases, results from Gates-2 were most similar to those from the MBSDE method. Moreover, paired t-test p-values between MBSDE method and phases were as follows Gates-1: 0.021 (p<0.05), Gates-2: 0.280 (p>0.05), and Gates-3: 0.164 (p>0.05) indicating that only Gates-1 had statistically significant differences compared with MBSDE method. Thus, setting ROI around 2~3 minutes is calculated can aid in accurately determining GFR when Gates Method.

Immortalization of Rat Kidney Glomerular Mesangial Cell and Its Coculture with Glomerular Epithelial Cell

  • Toshinobu Kida;Sachi Fujishima;Masatoshi Matsumra;Wang, Pi-Chao
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.2
    • /
    • pp.92-98
    • /
    • 2000
  • Mesangial cell has several key roles in thee control of glomerular function: it partocipates in the regulation of glomerular filtration rate, macromolecular clearance, and as both a source and target of numerous hormones and autocrines. Many of these insights into mesangial cell function have been obtained by studying mesangial cells in culture. However, no suitble cell lines have established yet. We here reported the immortalization of rat kidney glomeruar mesangial cell by transfection of E6 and E7 genes of human papillomavirus type 16 (HPV-16) via electroporation and lipofection. The reslts showed that only electroporation could transfect the genes to mesangial cells and the transfected cells maintained the viability for longer than 6 months. Fluorescence microscopic observation showed that cellular contractility and phagocytosis, which are the two main phenotypes of mesangial cells with rat glomerular epithelial cells showed that the growth of mesangial dells was suppressed by epithelial cell, but the growth of epithelisl cells was enhanced by mesangial cells. Moreover, Such results may imply that the glomerular cell-cell interaction plays an important role in the regulation of cell proliferation and differentiation.

  • PDF

Diagnosis of Chronic Kidney Disease using Sonography (초음파 영상을 이용한 만성 콩팥병의 진단)

  • Ahn, Yu-Ji;Ye, Soo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.153-159
    • /
    • 2017
  • Chronic kidney disease can be treated if it is detected early, but as the disease progresses, it becomes impossible to recover. Finally, renal replacement therapy such as transplantation or dialysis should be used. Ultrasonography is used to diagnose kidney cancer, inflammatory disease, nodular disease, and chronic kidney disease. It is used to identify information about degree of inflammation using information such as kidney size, internal echo characteristics. Currently, the degree of disease in the clinic uses the value of glomerular filtration rate. However, even in ultrasound, changes in the degree of inflammation and disease can be observed. In this study, we used ultrasound images to quantify the changes in brightness, size, cortex, and subclinical changes of the kidney with progression of the disease, and compared them with the glomerular filtration rate used in clinical practice. In 105 cases, we performed 35 cases of normal kidney, 35 cases of early kidney disease, and 35 cases of terminal kidney. The brightness of the cortex of the image was obtained and the difference in brightness between the cortex and the proximal portion was obtained by the slope. The graph of the portion which was not smooth due to the ultrasonic characteristics was used as the function regrass. The size reduction was obtained from the original data. The results were as follows: It was proportional to the glomerular filtration rate. It is considered that the algorithm can be applied to the disease if the algorithm study continues.

Associations between Anemia and Glomerular Filtration Rate and Albuminuria in Korean Adults by Metabolic Syndrome Status: Analysis of KNHNES V-3 Data (대한민국 성인의 대사증후군 유무에 따른 빈혈과 사구체 여과율 및 알부민뇨의 연관성: 국민건강영양조사 V-3 분석)

  • Hyun YOON
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.56 no.2
    • /
    • pp.125-134
    • /
    • 2024
  • The present study was conducted to explore relationships between anemia and estimated glomerular filtration rate (eGFR) and urine microalbumin/creatinine ratio (uACR) in Korean adults with or without metabolic syndrome (MetS). The data of 4,943 adults aged ≥20 years who participated in KNHNES V-3 (2012) were analyzed. In the non-MetS group, the odds ratio (OR) for anemia of those with a decreased eGFR {eGFR<60 mL/min/1.73 m2, 3.85 (95% confidence interval [CI], 2.03~7.30)} was significant as was the OR of those with decreased eGFR plus elevated uACR (eGFR<60 mL/min/1.73 m2 and uACR≥30 mg/g, 5.81 [95% CI, 2.60~13.02]). In the MetS group, ORs for anemia for those with an elevated uACR (2.18 [95% CI, 1.11~4.27]), a decreased eGFR (3.74 [95% CI, 1.11~12.55]), or a decreased eGFR plus an elevated uACR (16.79 [95% CI, 5.93~47.57]) were significant. In conclusion, in non-MetS, anemia was associated with a low eGFR, whereas in MetS, anemia was associated with a low eGFR and an elevated uACR. In addition, the OR for anemia was greatly increased when eGFR was diminished and uACR was elevated regardless of MetS and MetS status.

Glomerular Filtration Rate Test Methods and Guidelines (Glomerular Filtration Rate 검사방법 및 가이드라인)

  • Park, Min-Ho;Lee, Ha-Young;Ryu, Hwa-Jin;Yoo, Tae-Min;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.97-100
    • /
    • 2018
  • Purpose The glomerular filtration rate (GFR) test is an important indicator of glomerular filtration and has been used to test renal function and the extent of its function. The GFR test is performed by intravenous injection of radioactive medicines made of $^{51}Cr$-EDTA, and blood concentration is measured by taking blood according to the elapsed time. also, PET-CT, bone scan, transfusion and so on will affect the outcome. Therefore, we will improve the quality of the test by providing guidelines for the GFR test for more accurate testing. Materials and Methods 5 mL of physiological saline solution and 2 mL of $^{51}Cr$-EDTA solution are used to make 5 mL of the radiopharmaceutical solution to be injected into the patient. First, the syringe weight is measured before the injection, and then the radioactive medicine is injected into the patient's vein and the syringe weight is measured after the injection. Blood sampling is performed twice in total. In adults, blood is collected 3 hours / 5 hours after injection and in children 2 hours / 5 hours after injection. The blood sample is centrifuged at 3300 rpm for 5 minutes. Standard solution is prepared by filling diluent water up to the scale indicated in the 200-mL volumetric flask, discarding $500{\mu}L$, injecting $500{\mu}L$ of GFR reagent and mixing well. $500{\mu}L$ each of the standard solution is dispensed into two test tubes, and $500{\mu}L$ of each of the plasma samples collected in time is dispensed into two test tubes and measured with a Cobra Counter. Results At present, the reference range applied in this study is $119.5{\pm}30.3ml/min/1.73m2$ for males and $125.2{\pm}28.2ml/min/1.73m^2$ for females. Conclusion The GFR test is conducted using radioactive medical products. GFR testing is performed as a scheduled test, but PET-CT, dialysis and transfusion, which may affect GFR testing, may be scheduled during GFR testing. Therefore, we could get accurate GFR test results by notifying the ward and department beforehand when booking.

Risk Factors for Cardiac Implantable Electronic Device-Related Infections (이식형 심장 모니터링 장치 관련 감염의 위험요인)

  • Park, Jin Yeong;Choi, Hye-Ran
    • Journal of Korean Biological Nursing Science
    • /
    • v.23 no.4
    • /
    • pp.298-307
    • /
    • 2021
  • Purpose: This study aimed to investigate the risk factors for cardiac implantable electronic device (CIED)-related infections within the first post-procedural year after CIED insertion. Methods: This study included 509 adult patients undergoing CIED implantation procedures between January 1, 2011 and December 31, 2015. The data were analyzed by t-test, chi-square test, Fisher's exact test, and logistic regression analysis using SPSS/WIN 23.0. Results: Fifteen infections and 494 non-infections were examined. The CIED-related infection rate was 2.9%; patients with 14 pocket infections and one bacteremia were included in the CIED-related infection. The risk factors of CIED-related infections were the estimated glomerular filtration rate (eGFR) of ≤ 45 mL/min/1.73 m2 (Odds ratio [OR]= 4.03, 95% confidence interval [CI],1.15-14.10) and taking a new oral anticoagulant (NOAC) (OR = 4.50, 95% CI 1.09-18.55). Conclusion: These results identified the CIED infection rate and risk factors of CIED-related infection. It is necessary to consider these risk factors before the CIED implantation procedure and to establish the relevant nursing interventions.

A Study on Glomerular Filtration Rate Comparisons between Gates Method and Modified Gates Method used in Dynamic Renal Scintigraphy (동적 신장 신티그래피 검사 시 사용되는 Gates 법과 Modified Gates 법의 사구체 여과율 비교에 관한 고찰)

  • Ham, Jun-Cheol;Bahn, Young-Kag;Park, Min-Soo;Cho, Seok-Won;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.96-101
    • /
    • 2012
  • Purpose: Glomerular filtration rate is an important index for assessment of renal function, early discovery of renal disease, and progress observation of chronic renal disease patients. In the present study, the objective is to conduct a comparative analysis of differences between Gates and Modified Gates method in dynamic renal scintigraphy based on MDRD (Modification of Diet Renal Disease) formula using blood collection. Materials and Methods: Renal scintigraphy was performed for 45 patients who visited our hospital between November 2010 and August 2011. For 20 patients of those tested, glomerular filtration rates from Gates method and MDRD formula using AGUS equipment, were compared. For the other 20 patients, glomerular filtration rates from Modified Gates method and MDRD formula using INFINIA equipment. Finally, Gates and Modified Gates method were compared for 5 patients who indicated no change in glomerular filtration rates from MDRD formula during progress observation. Results: Glomerular filtration rates from both Gates and Modified Gates method showed a high correlation with those from MDRD formula ($p$<0.01, r=0.903, r=0.867), with a paired difference mean for Gates method of $2.05{\pm}2.54mL/min/1.73m$, and that for Modified Gates method of $25.2{\pm}3.71mL/min/1.73m$. Finally, the values for Gates method and those for Modified Gates method showed a high correlation for the five patients ($p$<0.05, r=0.949), with a paired difference mean of $20.4{\pm}8.84mL/min/1.73m$. Conclusion: Glomerular filtration rates from Gates method, Modified Gates method and MDRD formula showed mutually high correlations. If the tests are performed with recognition for the correlations between Gates and Modified Gates method used in a dynamic renal scintigraphy, then an accurate assessment of renal function is considered possible with an improved diagnostic ability.

  • PDF