• 제목/요약/키워드: Glenoid angles

검색결과 6건 처리시간 0.025초

악안면 골격부조화와 관절와위치간의 상관관계에 관한 연구 (A STUDY ON THE RELATIONSHIP BETWEEN THE GLENOID FOSSA POSITRON AND VARIOUS SKELETAL DISCREPANCIES)

  • 김철수;양원식
    • 대한치과교정학회지
    • /
    • 제17권1호
    • /
    • pp.47-54
    • /
    • 1987
  • This study was designed to compare extreme variations in facial growth in order to examine the relationships between the glenoid fossa position and skeletal malocclusions. It was hypothesized that patients with large mandibular plane-sella nasion angles would have a more superior fossa position than patients with small mandibular plane-sella nasion angles. It was also hypothesized that patients with large ANB angles would have a more posterior fossa position than patients with small ANB angle. For this study, the data from lateral roentgenocephaloprams of 72 Females and 72 males aged from 10 to 18 years were used. The results were as follows 1. In the case of large ANB angle, glenoid fossa position was relatively posterior than that of small ANB angle in Female, but it was not significant in male. 2. In the case of large APDI, glenoid fossa position was relatively anterior in female, but it was not significant in male. 3. In the case of large SN-Go Gn angle, glenoid fossa position was relatively superior in both male and female. 4. In the case of large ODI, glenoid fossa position was relatively inferior in both male and female.

  • PDF

Another Glenoid Measurements for Shoulder Surgery

  • Jeong, Yeon-Seok;Yum, Jae-Kwang;Lee, Jun-Seok
    • Clinics in Shoulder and Elbow
    • /
    • 제21권4호
    • /
    • pp.179-185
    • /
    • 2018
  • Background: We analyzed the angle between the glenoid anterior surface and glenoid axis, the range of the glenoid apex and the location of the glenoid apex for assistance during shoulder surgery. Methods: Sixty-two patients underwent a computed tomography of the shoulder with a proximal humerus fracture. In the range of the glenoid apex, the ratios of the distribution of triangles with a Constant anterior and posterior area of the glenoid were measured. The location of glenoid apex was confirmed as the percentage of the position with respect to the upper part of the glenoid with the center of the part, analyzed the angle between the glenoid anterior surface and glenoid axis was measured. Results: The angle between the glenoid anterior surface and glenoid axis was $19.80^{\circ}{\pm}3.88^{\circ}$. The location of the glenoid apex is $60.36%{\pm}9.31%$, with the upper end of the glenoid as the reference. The range of the glenoid apex was $21.16%{\pm}4.98%$. When the height of the glenoid becomes smaller, the range of the glenoid apex tends to become larger (p=0.001) and the range of the glenoid apex becomes wider (p=0.001) as the glenoid width narrows. Conclusions: We believe the anatomical measurements of the glenoid will be helpful for a more accurate insertion in glenoid component. It is thought that more accurate insertion is possible if we can set other anatomical measurements using computed tomography imaging of the glenoid which can develop into the study of other anatomical measurements.

Patient-specific Guides Using 3-dimensional Reconstruction Provide Accuracy and Reproducibility in Reverse Total Shoulder Arthroplasty

  • Yoon, Jong Pil;Kim, Dong Hyun;Jung, Jae Wook;Lee, Chang-Hwa;Min, Seunggi;Lee, Hyun Joo;Kim, Hee-June
    • Clinics in Shoulder and Elbow
    • /
    • 제22권1호
    • /
    • pp.16-23
    • /
    • 2019
  • Background: We aimed to evaluate whether the use of our novel patient-specific guide (PSG) with 3-dimensional reconstruction in reverse total shoulder arthroplasty (RTSA) would allow accurate and reliable implantation of the glenoid and humeral components. Methods: 20 fresh-frozen cadaveric shoulders were used. The PSG group (n=10) and conventional group (n=10) was evaluated the accuracy and reproducibility of implant positioning between before and after surgery on the computed tomography image. Results: The superoinferior and anteroposterior offset in the glenoid component were $0.42{\pm}0.07$, $0.50{\pm}0.08$ in the conventional group and $0.45{\pm}0.03$, $0.46{\pm}0.02$ in the PSG group. The inclination and version angles were $-1.93^{\circ}{\pm}4.31^{\circ}$, $2.27^{\circ}{\pm}5.91^{\circ}$ and $0.46^{\circ}{\pm}0.02^{\circ}$, $3.38^{\circ}{\pm}2.79^{\circ}$. The standard deviation showed a smaller difference in the PSG group. The anteroposterior and lateromedial humeral canal center offset in the humeral component were $0.45{\pm}0.12$, $0.48{\pm}0.15$ in the conventional group and $0.46{\pm}0.59$ (p=0.794), $0.46{\pm}0.06$ (p=0.702) in the PSG group. The PSG showed significantly better humeral stem alignment. Conclusions: The use of PSGs with 3-dimensional reconstruction reduces variabilities in glenoid and humerus component positions and prevents extreme positioning errors in RTSA.

Ten technical aspects of baseplate fixation in reverse total shoulder arthroplasty for patients without glenoid bone loss: a systematic review

  • Reinier W.A. Spek;Lotje A. Hoogervorst;Rob C. Brink;Jan W. Schoones;Derek F.P. van Deurzen;Michel P.J. van den Bekerom
    • Clinics in Shoulder and Elbow
    • /
    • 제27권1호
    • /
    • pp.88-107
    • /
    • 2024
  • The aim of this systematic review was to collect evidence on the following 10 technical aspects of glenoid baseplate fixation in reverse total shoulder arthroplasty (rTSA): screw insertion angles; screw orientation; screw quantity; screw length; screw type; baseplate tilt; baseplate position; baseplate version and rotation; baseplate design; and anatomical safe zones. Five literature libraries were searched for eligible clinical, cadaver, biomechanical, virtual planning, and finite element analysis studies. Studies including patients >16 years old in which at least one of the ten abovementioned technical aspects was assessed were suitable for analysis. We excluded studies of patients with: glenoid bone loss; bony increased offset-reversed shoulder arthroplasty; rTSA with bone grafts; and augmented baseplates. Quality assessment was performed for each included study. Sixty-two studies were included, of which 41 were experimental studies (13 cadaver, 10 virtual planning, 11 biomechanical, and 7 finite element studies) and 21 were clinical studies (12 retrospective cohorts and 9 case-control studies). Overall, the quality of included studies was moderate or high. The majority of studies agreed upon the use of a divergent screw fixation pattern, fixation with four screws (to reduce micromotions), and inferior positioning in neutral or anteversion. A general consensus was not reached on the other technical aspects. Most surgical aspects of baseplate fixation can be decided without affecting fixation strength. There is not a single strategy that provides the best outcome. Therefore, guidelines should cover multiple surgical options that can achieve adequate baseplate fixation.

견갑골 두께의 전산화 단층 촬영을 이용한 기하학적 모델 (Geometric Assessment of Scapular Thickness by Computed Tomography)

  • 유정현;정수태;박상준;장준희;백두진
    • Clinics in Shoulder and Elbow
    • /
    • 제15권2호
    • /
    • pp.73-78
    • /
    • 2012
  • 목적: 견갑골의 수술적 치료에 있어서 해부학적 및 형태학적인 이해는 매우 중요하다고 할 수 있다. 전산화 단층촬영을 이용하여 견갑골의 정확한 두께를 측정하고, 기하학적인 형태를 재구성함으로써 견갑골의 정확한 해부학적 및 형태학적인 정보를 제공하고자 하였다. 대상 및 방법: 총 51개의 해부용 시체에서 적출한 102개의 견갑골을 대상으로 하였으며, 일반적인 견갑골의 형태를 얻기 위해 8개의 평균적인 길이와 2개의 각을 측정하였다. 또한 견갑골의 두께를 측정하기 위해 각각의 견갑골에서 동일한 위치의 시상면을 얻고, 각각의 시상면에서 견갑골의 두께를 전산화 단층 촬영을 이용하여 측정하였다. 견갑골의 두께에 대한 실측치를 토대로 평균값을 계산하였으며, 성별에 따른 견갑골 두께의 차이를 Student t-test 를 이용하여 비교하였다. 결과: 견갑골 관절와의 평균 두께는 22.4 mm, 외측연의 평균 두께는 13.83 mm, 내측연의 평균 두께는 4.44 mm, 견갑골 체부의 중간 1/3 위치의 평균 두께는 2.06 mm 로 측정되었으며, 남성의 견갑골이 여성의 견갑골 보다 더 두껍게 측정되었다. 측정된 실측치를 참고로 하여 견갑골들의 두께에 대한 3차원적인 기하학적인 모델을 재구성하였다. 결론: 측정 수치의 분석 결과 견갑골의 두께가 가장 두꺼운 부분은 관절와 부위 및 외측연 부위이며, 반대로 두께가 가장 얇은 부분은 견갑골 체부의 중간 1/3 지점이 견갑골에서 가장 얇은 부위로 나타났다.

Novel condylar repositioning method for 3D-printed models

  • Sugahara, Keisuke;Katsumi, Yoshiharu;Koyachi, Masahide;Koyama, Yu;Matsunaga, Satoru;Odaka, Kento;Abe, Shinichi;Takano, Masayuki;Katakura, Akira
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제40권
    • /
    • pp.4.1-4.4
    • /
    • 2018
  • Background: Along with the advances in technology of three-dimensional (3D) printer, it became a possible to make more precise patient-specific 3D model in the various fields including oral and maxillofacial surgery. When creating 3D models of the mandible and maxilla, it is easier to make a single unit with a fused temporomandibular joint, though this results in poor operability of the model. However, while models created with a separate mandible and maxilla have operability, it can be difficult to fully restore the position of the condylar after simulation. The purpose of this study is to introduce and asses the novel condylar repositioning method in 3D model preoperational simulation. Methods: Our novel condylar repositioning method is simple to apply two irregularities in 3D models. Three oral surgeons measured and evaluated one linear distance and two angles in 3D models. Results: This study included two patients who underwent sagittal split ramus osteotomy (SSRO) and two benign tumor patients who underwent segmental mandibulectomy and immediate reconstruction. For each SSRO case, the mandibular condyles were designed to be convex and the glenoid cavities were designed to be concave. For the benign tumor cases, the margins on the resection side, including the joint portions, were designed to be convex, and the resection margin was designed to be concave. The distance from the mandibular ramus to the tip of the maxillary canine, the angle created by joining the inferior edge of the orbit to the tip of the maxillary canine and the ramus, the angle created by the lines from the base of the mentum to the endpoint of the condyle, and the angle between the most lateral point of the condyle and the most medial point of the condyle were measured before and after simulations. Near-complete matches were observed for all items measured before and after model simulations of surgery in all jaw deformity and reconstruction cases. Conclusions: We demonstrated that 3D models manufactured using our method can be applied to simulations and fully restore the position of the condyle without the need for special devices.