• Title/Summary/Keyword: Glasses frame

Search Result 37, Processing Time 0.021 seconds

Product Analysis and Development of Amblyopia Eye Patch for Children

  • Lim, Hosun;Sung, Juyoung
    • Fashion, Industry and Education
    • /
    • v.14 no.2
    • /
    • pp.1-10
    • /
    • 2016
  • In the present study, the materials, sizes, and designs of blind eye patch products of skin-adhesive type and glass-attachment type currently available in the market will be analyzed and ergonomically appropriate blind eye patches will be developed. Although these skin-adhesive type eye patches were easy to use, they had shortcomings such as skin troubles due to the adhesive used on the weak and sensitive skin of children and the fact that eyebrows are pulled out and the skin is irritated when the eye patches are detached after being attached. The non-adhesive type eye patches were blind patches to be worn by putting into glasses. These products were made using diverse materials such as neoprene, non-woven fabrics, and felt and showed differences in tactile impressions and irritation to the skin depending on material characteristics. In addition, most products were efficient in blocking light with three-dimensional oval designs comprising darts. In the present study, blind eye patches were designed to reduce skin troubles by using sweat-absorbing and quick-drying functional materials with soft tactile impressions. In addition, to increase the effect to block light and the degree of tight contact with the skin when the blind eye patches are worn compared to existing eye patch designs, the sides of the wings of the blind eye patches were widened, glass frame fixing plates were added, and the darts were made to be curved thereby making an ergonomic design reflecting the shape of the face. The non-adhesive type blind eye patches developed in the present study are considered to enhance the wearing sensation with the use of the material without skin irritation but with cushioning feelings and the ergonomic design reflecting the contour of the face.

Head Motion Detection and Alarm System during MRI scanning (MRI 영상획득 중의 피험자 움직임 감지 및 알림 시스템)

  • Pae, Chong-Won;Park, Hae-Jeong;Kim, Dae-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.55-66
    • /
    • 2012
  • Purpose : During brain MRI scanning, subject's head motion can adversely affect MRI images. To minimize MR image distortion by head movement, we developed an optical tracking system to detect the 3-D movement of subjects. Materials and Methods: The system consisted of 2 CCD cameras, two infrared illuminators, reflective sphere-type markers, and frame grabber with desktop PC. Using calibration which is the procedure to calculate intrinsic/extrinsic parameters of each camera and triangulation, the system was desiged to detect 3-D coordinates of subject's head movement. We evaluated the accuracy of 3-D position of reflective markers on both test board and the real MRI scans. Results: The stereo system computed the 3-D position of markers accurately for the test board and for the subject with glasses with attached optical reflective marker, required to make regular head motion during MRI scanning. This head motion tracking didn't affect the resulting MR images even in the environment varying magnetic gradient and several RF pulses. Conclusion: This system has an advantage to detect subject's head motion in real-time. Using the developed system, MRI operator is able to determine whether he/she should stop or intervene in MRI acquisition to prevent more image distortions.

Back-Propagation Neural Network Based Face Detection and Pose Estimation (오류-역전파 신경망 기반의 얼굴 검출 및 포즈 추정)

  • Lee, Jae-Hoon;Jun, In-Ja;Lee, Jung-Hoon;Rhee, Phill-Kyu
    • The KIPS Transactions:PartB
    • /
    • v.9B no.6
    • /
    • pp.853-862
    • /
    • 2002
  • Face Detection can be defined as follows : Given a digitalized arbitrary or image sequence, the goal of face detection is to determine whether or not there is any human face in the image, and if present, return its location, direction, size, and so on. This technique is based on many applications such face recognition facial expression, head gesture and so on, and is one of important qualify factors. But face in an given image is considerably difficult because facial expression, pose, facial size, light conditions and so on change the overall appearance of faces, thereby making it difficult to detect them rapidly and exactly. Therefore, this paper proposes fast and exact face detection which overcomes some restrictions by using neural network. The proposed system can be face detection irrelevant to facial expression, background and pose rapidily. For this. face detection is performed by neural network and detection response time is shortened by reducing search region and decreasing calculation time of neural network. Reduced search region is accomplished by using skin color segment and frame difference. And neural network calculation time is decreased by reducing input vector sire of neural network. Principle Component Analysis (PCA) can reduce the dimension of data. Also, pose estimates in extracted facial image and eye region is located. This result enables to us more informations about face. The experiment measured success rate and process time using the Squared Mahalanobis distance. Both of still images and sequence images was experimented and in case of skin color segment, the result shows different success rate whether or not camera setting. Pose estimation experiments was carried out under same conditions and existence or nonexistence glasses shows different result in eye region detection. The experiment results show satisfactory detection rate and process time for real time system.

The Clinical Study on Spectacle Wearers of Highschool Students (고등학생 안경착용자의 착용상태에 관안 임상적 연구)

  • Kim, Sang-Kyun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.19-27
    • /
    • 2004
  • The purpose of this study is to survey spectacle wearers's way of thinking through the questionaire and to investigate their wearing conditions through fitting conditions, the pantascopic angle, vertex distance, the coincidence of vertical and horizontal distance between optical center of the lens and pupillary distance of the eye in random selected 150 ametropic corrective wearers in the age of 17 to 19. The results are as follows : 1. The most popular causes of physical complaints in the ex-wearing spectacle are frame pressure(34.0%), slipping forward(30.0%) and most popular visual complaints are blur vision(30.0%) and asthenopia(20.0%). 2. The most common physical or visual complaints in the present wearing spectacle are slipping forward(30.0%), pressure (50.0%), color(10.0%). 3. Myopic glasses wearers accounted for 56.7% of the subjects, the others were compound myopic astigmatism. In 60% of the subjects' binocular diopter did not coincide. 4. In the pantascopic angle of the both eyes coincide in 66.7% of the subjects. The average of pantascopic angle is $10.07^{\circ}$. 5. In the vertex distance of the both eyes coincided in 65.3% of the subjects. the he average of vertex distance is 13.6 mm. 6. Among 150 eyes with monocular, the vertical distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG 915 that is tolerance of ophthalmic dispensing in German Standards in 82 eyes (54.6%). 7. Among 150 eyes with monocular, the horizontal distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG915 that is tolerance of ophthalmic dispensing in German Standards in 86 eyes(57.3 %).

  • PDF

An Input/Output Technology for 3-Dimensional Moving Image Processing (3차원 동영상 정보처리용 영상 입출력 기술)

  • Son, Jung-Young;Chun, You-Seek
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.8
    • /
    • pp.1-11
    • /
    • 1998
  • One of the desired features for the realizations of high quality Information and Telecommunication services in future is "the Sensation of Reality". This will be achieved only with the visual communication based on the 3- dimensional (3-D) moving images. The main difficulties in realizing 3-D moving image communication are that there is no developed data transmission technology for the hugh amount of data involved in 3-D images and no established technologies for 3-D image recording and displaying in real time. The currently known stereoscopic imaging technologies can only present depth, no moving parallax, so they are not effective in creating the sensation of the reality without taking eye glasses. The more effective 3-D imaging technologies for achieving the sensation of reality are those based on the multiview 3-D images which provides the object image changes as the eyes move to different directions. In this paper, a multiview 3-D imaging system composed of 8 CCD cameras in a case, a RGB(Red, Green, Blue) beam projector, and a holographic screen is introduced. In this system, the 8 view images are recorded by the 8 CCD cameras and the images are transmitted to the beam projector in sequence by a signal converter. This signal converter converts each camera signal into 3 different color signals, i.e., RGB signals, combines each color signal from the 8 cameras into a serial signal train by multiplexing and drives the corresponding color channel of the beam projector to 480Hz frame rate. The beam projector projects images to the holographic screen through a LCD shutter. The LCD shutter consists of 8 LCD strips. The image of each LCD strip, created by the holographic screen, forms as sub-viewing zone. Since the ON period and sequence of the LCD strips are synchronized with those of the camera image sampling adn the beam projector image projection, the multiview 3-D moving images are viewed at the viewing zone.

  • PDF

Evaluation of Reliability for Combined Refractive Power of Lenses in an Automatic Phoropter (자동포롭터 내부렌즈의 합성굴절력에 대한 신뢰도 평가)

  • Lee, Hyung Kyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.501-509
    • /
    • 2015
  • Purpose: To evaluate the reliability of refractive power by comparing the marked refractive power in an automatic phoropter and actually measured spherical/cylindrical refractive power. Methods: Actual refractive power of minus spherical lens and cylindrical lens in an automatic phoropter was measured by a manual lensmeter and compared with the accuracy of marked refractive power. Furthermore, combined refractive power and spherical equivalent refractive power of two overlapped lenses were compared and evaluated with the refractive power of trial lens. Results: An error of 0.125 D and more against the marked degree was observed in 70.6% of spherical refractive power of spherical lens which is built in phoropter, and the higher error was shown with increasing refractive power. Single cylindrical refractive power of cylindrical lens is almost equivalent to the marked degree. Combined spherical refractive power was equivalent to spherical refractive power of single lens when spherical lens and cylindrical lens were overlapped in a phoropter. Thus, there was no change in spherical refractive power by lens overlapping. However, there was a great difference, which suggest the effect induced by overlapping between cylindrical refractive power and the marked degree when spherical lens and cylindrical lens were overlapped. Spherical equivalent refractive power measured by using a phoropter was lower than that estimated by trial glasses frame and marked degree. The difference was bigger with higher refractive power. Conclusions: When assessment of visual acuity is made by using an automatic phoropter for high myopes or myopic astigmatism, some difference against the marked degree may be produced and they may be overcorrected which suggests that improvement is required.

Changes of Visual Acuity and Ophthalmic Symptoms in Female Workers examining Silver Plating Products (은도금제품 검사실 여성근로자들의 시력변화 및 안증상)

  • Ryu, Seung-Ho;Son, Jeong-Il;Lee, Soo-Jin;Song, Jae-Cheol
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.3 s.58
    • /
    • pp.567-576
    • /
    • 1997
  • To evaluate the effects of reflected glare on eyes, authors assessed the periodic health examination(1991-1996) & self-administered questionnaire data of a semiconductor producing company. The 13 lead frame(LF) department workers have been exposed to high reflected glare in the process for examining the silver plating products. We compared the data of connector(14) and clerical(12) workers as the non-exposed ones. Among LF department workers, 100% felt their visual acuity worsened(connector:81.8%, clerical:85.7%), and 70% had worn the glasses o. contact lenses(connector : 14.3%, clerical :40%) since working at the company. Major ophthalmic symptoms of the LF workers are asthenopia, tearing, decreased visual acuity, congestion and glare. Decrease of visual acuity by Hahn's line change of the LF workers is significantly high during a 5-year follow-up(p<0.05 by simple regression) compared with connector clerical workers.

  • PDF