• 제목/요약/키워드: Glass detector

Search Result 90, Processing Time 0.346 seconds

Evaluation of Thermography Camera Using Molded Optical Lens for Medical Applications (몰드성형 광학렌즈를 이용한 의료기기용 열화상카메라 체열진단의 적용도 평가)

  • Ryu, Seong Mi;Kim, Hye-Jeong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.8
    • /
    • pp.624-628
    • /
    • 2013
  • With the recent development of less-costly uncooled detector technology, expensive optics are among the remaining significant cost drivers in the thermography camera. As a potential solution to this problem, the fabrication of IR lenses using chalcogenide glass has been studied in recent years. We report on the molding and evaluation of a ultra-precision chalcogenide-glass lens for the thermography camera for body-temperature monitoring. In addition, we fabricated prototype thermography camera using the chalcogenide-glass lens and obtained the thermal image from the camera. In this work, it was found out that thermography camera discerned body-temperature between 20 and $50^{\circ}C$ through the analysis of thermal image. It is confirmed that thermography camera using the chalcogenide-glass lens is applicable to the body-temperature monitoring system.

Development of in-situ Analysis System for Radwaste Glass Using Laser Induced Breakdown Spectroscopy (레이저유도 플라즈마분광법을 이용한 방사성폐기물 유리의 현장분석 시스템 개발)

  • 김천우;박종길;신상운;하종현;송명재;이계호
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.137-146
    • /
    • 2004
  • Laser Induced Breakdown Spectroscopy(LIBS) system is being developed as an in-situ analysis system for the radioactive waste glass in the cold crucible melter. In order to complete the LIBS system, a spectrometer, a detector, and a laser were structured. An ESA 3000 (LLA Instruments GmbH, Germany) including a calibrated Kodak KAF-1001 CCD detector was selected as the spectrometer. A Q-switched Nd-YAG Brilliant(Quantel, France) laser was selected as an energy source. As the first research stage, the excitation temperatures of Fe(I) as a function of the detector's delay intervals(500, 1000, 1500, 2000ns) were evaluated using the Einstein-Boltzmann equation. The optimized excitation temperature of Fe (I) was 7820k at the delay time of 1500㎱ using the 532nm Nd-YAG laser pulse. This LIBS system will be optimized under the real environment vitrification facility in the near future and then used to be in-situ analyzed the glass compositions in the melter qualitatively.

  • PDF

Determination of Output Factors for the Gamma Knife using a Radiophotoluminescent Glass Rod Detector (유리선량계를 이용한 감마나이프의 출력인자 결정)

  • Rah, Jeong-Eun;Suh, Won-Seop;Shin, Dong-Oh;Kim, Hee-Sun;Suh, Tea-Suk
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.13-19
    • /
    • 2007
  • The purpose of study Is to Investigate whether glass rod detector (GRD) would be suitable for dosimeter of radiotherapy units. A GRD Is used for the measurement of the ou4put factors and x-axis beam profiles from Gamma Knife. The output factors measured with GRD from the 14, 8 and 4mm collimators relative to the 18mm collimator are $0.980{\pm}0.013,\;0.949{\pm}0.013\;and\;0.872{\pm}0.012$, respectively. The output factors obtained with a GRD are within 1.0% In good agreement with the values recommended by the manufacture. The full width at half maximum (FWHM) of x-axis beam profiles measured with GRD are 5.9mm at a 4mm collimator.

  • PDF

Comparative Study of the Effective Dose from Panoramic Radiography in Dentistry Measured Using a Radiophotoluminescent Glass Dosimeter and an Optically Stimulated Luminescence Detector

  • Lee, Kyeong Hee;Kim, Myeong Seong;Kweon, Dae Cheol;Choi, Jiwon
    • Journal of the Korean Physical Society
    • /
    • v.73 no.9
    • /
    • pp.1377-1384
    • /
    • 2018
  • Accurate measurement of the absorbed dose and the effective dose is required in dental panoramic radiography involving relatively low energy with a rotational X-ray tube system using long exposures. To determine the effectiveness of measuring the irradiation by using passive dosimetry, we compared the entrance skin doses by using a radiophotoluminescent glass dosimeter (RPL) and an optically stimulated luminescence detector (OSL) in a phantom model consisting of nine and 31 transverse sections. The parameters of the panoramic device were set to 80 kV, 4 mA, and 12 s in the standard program mode. The X-ray spectrum was applied in the same manner as the panoramic dose by using the SpekCalc Software. The results indicated a mass attenuation coefficient of $0.008226cm^2/g$, and an effective energy of 34 keV. The equivalent dose between the RPL and the OSL was calculated based on a product of the absorbed doses. The density of the aluminum attenuators was $2.699g/cm^3$. During the panoramic examination, tissue absorption doses with regard to the RPL were a surface dose of $75.33{\mu}Gy$ and a depth dose of $71.77{\mu}Gy$, those with regard to the OSL were surface dose of $9.2{\mu}Gy$ a depth dose of $70.39{\mu}Gy$ and a mean dose of $74.79{\mu}Gy$. The effective dose based on the International Commission on Radiological Protection Publication 103 tissue weighting factor for the RPL were $0.742{\mu}Sv$, $8.9{\mu}Sv$, $2.96{\mu}Sv$ and those for the OSL were $0.754{\mu}Sv$, $9.05{\mu}Sv$, and $3.018{\mu}Sv$ in the parotid and sublingual glands, orbit, and thyroid gland, respectively. The RPL was more effective than the OSL for measuring the absorbed radiation dose in low-energy systems with a rotational X-ray tube.

A study on medium-low pressure gauge for domestic production (중.저기압 압력계의 국산화에 관한 연구)

  • 백용현
    • 전기의세계
    • /
    • v.29 no.8
    • /
    • pp.519-523
    • /
    • 1980
  • The traditional mechanical manometer is improved to develop more convenient and precise manometer in continuous measurement of the gas pressure in medium-low vacuum range (1x10$^{-1}$ -10 Torr.) Glass (solid) is used as a detector material of the improved manometer. Using the strain gauge adhered to thin glass board, mechanical strain corresponding to variation of pressure in measurement system is converted into quantity of electricity, and the quantity of electricity is amplified. Experiments have also shown that the improved manometer have more advantages in reproducibility, measured sensibility, and responsible velocity than taditional one.

  • PDF

Study on Dosimetric Properties of Radiophotoluminescent Glass Rod Detector (유리선량계의 선량 특성에 관한 연구)

  • Rah, Jeong-Eun;Shin, Dong-Oh;Hong, Ju-Young;Kim, Hee-Sun;Lim, Chun-Il;Jeong, Hee-Gyo;Suh, Tea-Suk
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.181-186
    • /
    • 2006
  • A radiophotoluminescent glass rod detector (GRD) system has recently become commercially available. We investigate the dosimetric properties of the GRD regarding the reproducibility of signal, dose linearity and energy dependence. The reproducibility of five measurements for 50 GRDs is presented by an average of one standard deviation of each GRD and it is ${\pm}1.2%$. It is found to be linear in response to doses of $^{60}Co$ beam in the range 0.5 to 50 Gy with a coefficient of linearity of 0.9998. The energy dependence of the GRD is determined by comparing the dose obtained using cylindrical chamber to that by using the GRD. The GRD response for each beam is normalized to the response for a $^{60}Co$ beam. The responses for 6 and 15 MV x-ray beams are within ${\pm}1.5%$ (1SD). The energy response of GRD for high-energy photon is almost the same as the energy dependence of LiF:Mg:Ti (TLD-100)and shows little energy dependence unlike p-type silicon diode detector. The GRDs have advantages over other detectors such diode detector, and TLD: linearity, reproducibility and energy dependency. It has been verified to be an effective device for small field dosimetry for stereotactic radiosurgery.

In situ Stress Measurements with Submonolayer Sensitivity As a Probe of Coherent-to-incoherent Matching at an Interface in Ultrathin Magnetic Films

  • Jeong, Jong-Ryul;Kim, Young-Seok;Shin, Sung-Chul
    • Journal of Magnetics
    • /
    • v.7 no.4
    • /
    • pp.151-155
    • /
    • 2002
  • In situ stress changes at interfaces of ultrathin magnetic films were measured by means of a non-contact optical fiber bundle displacement detector. A bending of the substrate due to stress of a deposited film was detected in cantilever geometry. The highest sensitivity of 134 mV/$\mu$m for the displacement detector was realized with a help of computer simulation. The detector was applied to in situ stress measurements of Co/Pt and Ni/Pd magnetic multilayer films prepared on the glass substrates by dc magnetron sputtering. The detector turned out to have a submonolayer sensitivity that enables to observe coherent-to-incoherent transition in these mismatched multilayers and even detect the stress changes within the monoatomic coverage. This highly sensitive detector paves new way to probe the stress relaxation at an interface in ultrathin films.

The characteristic study of hybrid X-ray detector using ZnS:Ag phosphor (ZnS:Ag phosphor를 이용한 hybrid 형 X-ray detector 특성 연구)

  • Park, Ji-Koon;Gang, Sang-Sik;Lee, Dong-Gil;Cha, Byeong-Yeol;Nam, Sang-Hee;Choi, Heung-Kook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.27-30
    • /
    • 2002
  • Photoconductor for direct detection flat-panel imager present a great materials challenge, since their requirements include high X -ray absorption, ionization and charge collection, low leakage current and large area deposition. Selenium is practical material. But it needs high thickness and high voltage in selenium for high ionization rate. We report comparative studies of detector sensitivity. One is an a-Se with $70{\mu}m$ thickness on glass. The other has hybrid layer of depositting ZnS phosphor with $100{\mu}m$ on a-Se. The leakage current of hybrid is similar to it of a-Se, but photocurrent is lager than a-Se. Both of them have high spatial resolution, but hybrid has higher sensitivity than a-Se at comparable bias voltage.

  • PDF

IN SITU STRESS MEASUREMENTS OF Co-BASED MULTILAYER FILMS

  • Kim, Young-Suk;Shin, Sung-Chul
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.470-473
    • /
    • 1995
  • We have constructed an apparatus for in sity measurement of stress of the film prepared by sputtering using an optical noncontact displacement detector. A Change of the gap distance between the detector and the substrate, caused by stress of a deposited film, was detected by a corresponding change of the reflectivity. The sensitivity of the displacement detector was $5.9\;{\mu}V/{\AA}$ and thus, it was turned out to be good enough to detect stress caused by deposition of a monoatomic layer. The apparatus was applied to in situ stress measurements of Co/X(X=Pd or Pt) multilayer thin films prepared on the glass substrates by dc magnetron sputtering. At the very beginning of the deposition, both Co and X sublayers have subjected to their own intrinsic stresses. However, when the film was thicker than about $100{\AA}$, constant tensile stress in the Co sublayer and compressive stress in the X sublayer were observed, which is believed to be related to a lattice mismatch between the matching planes of Co and X.

  • PDF