• Title/Summary/Keyword: Glass Fiber Optic System

Search Result 12, Processing Time 0.026 seconds

Design and characteristics of a fiber-optic pressure sensor (광압력 센서의 설계 및 특성)

  • Kim, Young-Soo;Kim, Yo-Hee;Strigalev, V. E.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.508-510
    • /
    • 1995
  • A fiber-optic pressure sensor is fabricated with a photoelastic glass material. To remove the influence of external pertubation along the optical fiber, a new referencing technique is proposed by using two light sources. LED with 870nm wavelength is used as light source for reference signal, and LED with 660nm wavelength is used as light source for modulation signal. The fiber-optic pressure sensor system shows good linearity within the pressure range of 0 to 5 $kg/cm^2$.

  • PDF

Design of Algorithm for maximum Signal Sensing by Optical System (광시스템에서 maximum 신호 Sensing을 위한 Algorithm 설계)

  • Choi, Do-Sun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.4
    • /
    • pp.70-75
    • /
    • 2010
  • In this paper, was designed Algorithm Brent. this Algorithm can be used in the medical optical system. Optical signals are transmitted using optical fibers and integrated Optic. Developed Algorithm finds the maximum of the transmitted signal intensity. Optical system is made for Laser-Diode, HeNe-Laseer, controller for stepping motor, glass fiber and integrated Optic, etc. In this paper, two algorithms were investigated.

  • PDF

불포화 토양내에서 가스상 오존 측정을 위한 광섬유센서의 적용

  • 정해룡;최희철
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.111-114
    • /
    • 2003
  • A new monitoring system has been developed for in-situ and realtime measurement of ozone transport in unsaturated porous media using a fiber optic sensor. The calibration of the fiber optic transflection dip probe (FOTDP) system was successfully carried out at various ozone concentrations using a column with length of 30 cm and diameter of 5 cm packed with glass beads, which don't react with gaseous ozone. The breakthrough curves (BTCs) of ozone was obtained by converting the normalized intensity into ozone concentration. The FOTDP system reflected the ideal transport phenomena of gas phase ozone at various flow rates. The FOTDP system worked well for in-situ monitoring of gas phase ozone at various water saturations and in presence of SOM. However, the FOTDP system did not measure the ozone concentration at more than 70% water saturation.

  • PDF

FIBER OPTIC SENSOR FOR IN-SITU AND REALTIME MONITORING OF TRANSPORT OF GAS PHASE OZONE IN UNSATURATED POROUS MEDIA

  • Jung, Hae-Ryong;Park, Hee-Chul
    • Environmental Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.71-78
    • /
    • 2005
  • A series of column experiments was conducted to develop a monitoring system for in-situ and realtime measurement of ozone transport in unsaturated porous media using a fiber optic sensor. The calibration of the fiber optic transflection dip probe (FOTDP) system was successfully carried out at various ozone concentrations using a column with length of 30 cm and diameter of 5 cm packed with glass beads, which don't react with gaseous ozone. The breakthrough curves (BTCs) of ozone were obtained by converting the normalized intensity into ozone concentration. The FOTDP system worked well for in-situ monitoring of gas phase ozone at various water saturations and in presence of soil organic matter (SOM). However, the FOTDP system did not measure the ozone concentration at more than 70% water saturation.

A Study on the Magnetooptic Current Measurement System Using SF-4 Flint Glass (SF-4 Flint Glass를 이용한 자기광학적 전류측정시스템에 관한 연구)

  • Jo, In-Sik;Kim, Eun-Su;Yang, In-Eung
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.3
    • /
    • pp.43-47
    • /
    • 1985
  • This paper describes fiber-optic current sensor using SF-4 flint glass for the first time, ails the flint glass has been theoretically analyzed by jones matrix and experimentally verified. Verdet constant of SF-4 flint glass, which determines the sensitivity of current sensor, has been experimentally found as 0.0606(min/g.cm). It is relatively lower value than currently used faraday rotators such as FR-5, SF-6 flint glasses and YIG. The fiber.optic current sensor system was established and the current measurement was performed in the range of 100-600 (A) and 100- 500 (G). It has beenfhown by the experi-mental results that the detector output linearly increased in proportion to the current. Since these experimental results were in good agreement with theoretical results, it has been shown that SF-4 flint glass can be used for the magnetooptic current sensor.

  • PDF

The Optimal Design of POF Optical Connector for Medical Image Transmission System (의료영상전송시스템을 위한 POF 광커넥터의 최적 설계)

  • Cheon, Min-Woo;Cho, Kyung-Jae;Park, Yong-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.12
    • /
    • pp.978-982
    • /
    • 2010
  • For mass information transfer, the optical communication using optic fiber has been widely used. Especially, in the field of medical image, the large data is digitalized based on the standard image and it is used for telemedicine with this method. Therefore, to transfer the large amount of data fast and effectively POF (Plastic Optical Fiber) can be used and the development of optic connector for connection between POFs is very important. In this study, for stable optical coupling of POF optic fiber Ferrule and Sleeve were designed and produced by considering the bond stability and the insertion loss according to the physical contact and roughness profile was evaluated. As a result of examining the insertion loss by physical contact method of two optic fibers, it showed the loss was about 1.895dB. According to the results from studying the condition of grinding section for POF mass production, the mass production condition was established as POF profile roughness of 6nm and the loss of 0.2dB or lower by controlling the film size and time step by step.

Development of laser thermal printing device

  • Park, Ill-Hyun;Kwon, Jin-Hyuk;Yi, Jong-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.919-921
    • /
    • 2007
  • A laser thermal printing system was developed to fabricate OLED. A single mode fiber laser beam was diffracted by an acousto-optic modulator. The diffracted beam was sent to a galvanometer to print organic film on ITO glass with resolution of $30\;{\mu}m$.

  • PDF

Fiber-optic Mach-Zehnder Interferometer for the Detection of Small AC Magnetic Field (미소 교류 자기장 측정을 위한 Mach-Zehnder 광섬유 간섭계 자기센서 특성분석)

  • 김대연;안준태;공홍진;김병윤
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.139-148
    • /
    • 1991
  • A fiber-optic magnetic sensor system for the detection of small ac magnetic field(200Hz-2 kHz) was constructed. Magnetic field sensing part was fabricated by bonding a section of optical fiber to amorphous metallic glass(2605SC) having large magnetostriction effect. And with the directional coupler, all fiber type Mach-Zehnder interferometer was constructed to measure the variation of the external magnetic field by translating it into the optical phase shift in the interferometer. The signal fading problem of the interferometer, which is due to random phase drifts originated from the environment, i.e., temperature fluctuation, vibrations, etc., was elliminated by feedback phase compensation. This allows the sensitivity to be maintained at the maximum by keeping the interferometer in quadrature phase condition. The frequency response of metallic glass was found to be nearly flat in the range of 90 Hz-2 kHz and dc bias field for the maximum ac response was 3.5 Oe. The interferometer output showed good linearity over the range $\pm$0.5 Oe. For 1 kHz ac magnetic field the scale factor S and the minimum detectable magnetic field were measured to be 8.0 rad/Oe and $3X10^{-6} Oe/\sqrt{Hz}$at 1 Hz detection bandwidth respectively.

  • PDF

Study for Application of Daylighting using Reflector (반사경을 이용한 자연채광 적용 연구)

  • Han, JungHun;Ryu, SeongChan;Yoon, JunHo;Kim, JungHwan;Cho, DooYoung;Park, SunKyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.40.2-40.2
    • /
    • 2010
  • The Solar Daylighting Technology is considered with the plan that will be able to embody the energy technology which is possible to continue. Daylighting has an considerable advantage of the high effectiveness and the various use because daylighting can use the infrared ray, the visible ray and the ultraviolet rays without energy transformation. In this study, the experiment is tried of making the shape and an arrangement of the reflector different After establishing the reflector in the height(10m) which is fixed. It's also researched on the shape of the efficient reflector using the program(Trace Pro) at the time of the autumnal equinox and the winter solstice at fixed hours.

  • PDF