• Title/Summary/Keyword: Geometric standard deviation

Search Result 101, Processing Time 0.027 seconds

Measurement of Normal Gastric Emptying Rate Using Chicken Liver Labeled with $^{99m}Tc-Colloid$ (정상인의 Gastric Emptying Rate 측정)

  • Lee, Cheorl-Woo;Kim, Chahng-Guhn;Kim, Byung-Chan;Won, Jong-Jin;Nah, Yong-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.22 no.2
    • /
    • pp.193-197
    • /
    • 1988
  • Measurement of gastric emptying rate has been performed by a variety of techniques. Nuclear medicine method is a major advance in the quantitative evaluation of gastric function and also of pharmacologic intervention. Normal gastric emptying rate was measured in 48 healthy volunteers using live chicken liver labeled with $^{99m}Tc-Tin$ Colloid as a solid phase marker. In vitro studies were performed to evaluate the labeling efficiency and stability in hydrochloric acid and in human gastric juice of intracellularly labeled chicken liver. Anterior image counts only were compared with the geometric mean of anterior and posterior counts in 12 healthy volunteers who were studied by both anterior count and posterior count. The results were as follows: 1) The labeling efficiency in gastric juice and hydrochloric acid were $95.5{\pm}1.23%,\;95.7{\pm}1.15%$, respectively. 2) Half gastric emptying time by anterior count only was $126{\pm}21$ minutes 3) Although standard deviation of geometric mean method was smaller than anterior count method, gastric emptying curves from both method were similar. In daily practice, anterior count method may be useful alternative to geometric mean method in evaluation of gastric emptying rate.

  • PDF

Comparison of Composite Methods of Satellite Chlorophyll-a Concentration Data in the East Sea

  • Park, Kyung-Ae;Park, Ji-Eun;Lee, Min-Sun;Kang, Chang-Keun
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.6
    • /
    • pp.635-651
    • /
    • 2012
  • To produce a level-3 monthly composite image from daily level-2 Sea-viewing Wide Field-of-view Sensor (SeaWiFS) chlorophyll-a concentration data set in the East Sea, we applied four average methods such as the simple average method, the geometric mean method, the maximum likelihood average method, and the weighted averaging method. Prior to performing each averaging method, we classified all pixels into normal pixels and abnormal speckles with anomalously high chlorophyll-a concentrations to eliminate speckles from the following procedure for composite methods. As a result, all composite maps did not contain the erratic effect of speckles. The geometric mean method tended to underestimate chlorophyll-a concentration values all the time as compared with other methods. The weighted averaging method was quite similar to the simple average method, however, it had a tendency to be overestimated at high-value range of chlorophyll-a concentration. Maximum likelihood method was almost similar to the simple average method by demonstrating small variance and high correlation (r=0.9962) of the differences between the two. However, it still had the disadvantage that it was very sensitive in the presence of speckles within a bin. The geometric mean was most significantly deviated from the remaining methods regardless of the magnitude of chlorophyll-a concentration values. Its bias error tended to be large when the standard deviation within a bin increased with less uniformity. It was more biased when data uniformity became small. All the methods exhibited large errors as chlorophyll-a concentration values dominantly scatter in terms of time and space. This study emphasizes the importance of the speckle removal process and proper selection of average methods to reduce composite errors for diverse scientific applications of satellite-derived chlorophyll-a concentration data.

A Study of Uniformity Test in PET/CT (PET/CT 장치의 uniformitly측정에 관한 연구)

  • Kim, Su-Keun;Jung, Hee-Il;Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • The PET scanner can detect the photon pair arriving from the source in phantom. The number of light photons released by the crystal(scintillator-BGO or LSO). In recent scintillation crystals in block structures were incorporated into full ring systems, and their resulted marked improvement in spatial resolution and increase in a sensitivity to annihilations. The uniformity of the crystal sensitivity is very important to makes correct information of abnormal states in organs. These factors influenced by the dection efficiency of the scintillators. We have study about the uniformity of crystals to the annihilation, And study about the standard deviation to average counts. The relative standard deviation in central detector groups more uniformed than circumferenced detector groups. It is caused detected quanta of gamma ray by the geometrical factors of PET detector. PET cameras are available with different geometric arrangement and several parallel rings oriented in the axial direction. The center groups from 7th to 40th groups are comparatively uniform and sensitive. But at the circumferenced detectors decreased the sensitivity and uniformity.

  • PDF

Effects of Ethyl Acetate Extracts of Folium Mori on Cadmium Inhalation Toxicity (상엽 Ethyl Acetate 추출물이 카드뮴의 흡입독성에 미치는 영향)

  • Jeung Jaeyeal;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.3
    • /
    • pp.700-710
    • /
    • 2003
  • For the experiment of the effects between cadmium aerosol inhalation toxicity and ethyl acetate extracts of Folium Mori, 4 inhalation exposure groups of rat were exposed to cadmium aerosol in air by whole-body inhalation exposure for 6 hours/day, 5 days/week, and 4 weeks. Cadmium concentration in the air was 0.96㎎/㎥ and mass median diameter (MMD) was 2.48㎛ with 1.85 of geometric standard deviation(GSD). Intraperitoneal injections of ethyl acetate extracts of Folium Mori to inhalation exposure groups were performed for 4 weeks and the results were as follows: The highest body weight gain for 4 weeks and food intake per day were 159.29/4 weeks in treated group III and 18.45g/day in treated group I, respectively. The highest lung and liver weights were 1.31 g in treated group I and 9.42g in treated group III, respectively. The highest kidney weight was 2.21g from treated group I. The lowest cadmium content in lung was 86.39㎍/g from treated group III and the lowest cadmium concentration in blood was 2.72㎍/㎗ from treated group II. Cadmium concentrations of 22.09㎍/g in liver and 24.82㎍/g in kidney were the lowest from inhalation exposure group I and III, respectively. For weekly cadmium concentration in urine, the value of the fourth week from treated group III was the highest, 1.35㎍/㎖. For weekly cadmium concentration in feces, the values of the second and fourth week from treated group I were the highest, 1.11㎍/g. The highest metallothionein concentration in lung was 31.85㎍/g from treated group III and the highest metallothionein concentration in liver was 205.77㎍/g from treated group III. The highest metallothionein concentration in kidney was 206.55㎍/g from treated group III. The highest Hct and Hb values were 38.26% and 11.63g/㎗ from treated group III, respectively. The highest RBC and WBC values were 7.68×106/㎣ and 9.85×10³/㎣ from treated group I, respectively.

Evaluation of EGM2008 earth geopotential model using GPS/leveling data (GPS/leveling 데이터에 의한 EGM2008 지구중력장모델의 평가)

  • Lee, Suk-Bae;Kim, Jin-Soo;Kim, Cheol-Young
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.16 no.3
    • /
    • pp.117-126
    • /
    • 2008
  • Earth geopotential models were used to determine the reference surface in geoid modelling and many global geopotential models were developed after 1980's. Nowadays, EGM96 and EIGEN-GL04C geopotential models have been most widely used in the world, but what so called EGM2008 earth geopotential model were developed in 2008 by NGA. In this paper, we intended to compare the results of spherical harmonic analyses using the three geopotential model, EGM96, EIGEN-GL04C and EGM2008. So, the spherical harmonic analyses were performed up to degree and order 360(in case of EGM2008, up to degree and order 720, 1440, 2190 in addition), on each $1'{\times}1'$grid point in and around Korean peninsula. Geometric geoid were calculated at 464 GPS/leveling points for accuracy evaluation and then the results of three geopotential models were compared to geometric geoid. The results show that the accuracy of EGM2008 is improved considerablely compared to EGM96 and EIGEN-GL04C and it is possible to calculate geoidal heights within 14cm standard deviation and 5.5cm standard deviation after LSC fitting in and around Korean peninsula using EGM2008 geopotential model.

  • PDF

Comparison of Recognition and Fit Factors according to Education Actual Condition and Employment Type of Small and Medium Enterprises (중소규모 사업장의 교육 환경과 고용형태에 따른 호흡보호구 인식도 및 밀착계수 비교)

  • Eoh, Won Souk;Choi, Youngbo;Shin, Chang Sub
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.28-36
    • /
    • 2018
  • There was a difference in recognition of respirators according to the educational performance environment. they were showed higher recognition of respirators of group by internal and external mix trainer, less than 6 months, over 1hour, more than 5 times, variety of education. To identify the relationship between types of job classification(typical and atypical)and the levels of recognition of respirators, a total of 153 workers in a business workplace. mainly, typical workers showed higher recognition of respirators than atypical workers. Training of correct wearing showed high demands both typical and atypical workers. Descriptive statistics(SAS ver 9.2)was performed. the results of recognition of respirators were analyzed the mean and standard deviation by t-test, and anova, fit factor is used geometric means(geometric standard deviation), paired t-test, Wilcoxon analysis(P=0.05). Particulate filtering facepiece respirators (PFFR) is one of the most widely used items of personal protective equipments, and a tight fit of the respirators on the wearers is critical for the protection effectiveness. In order to effectively protect the workers through the respirators, it is important to find and evaluate the ways that can be readily applicable at the workplace to improve the fit of the respirators. This study was designed to evaluate effects of mask style (cup or foldable type) and donning training on fit factors (FF) of the respirators, since these are available at various workplace, especially at small business workplace. A total of 40 study subjects, comprised of employment type workers in metalworking industries, were enrolled in this study. The FF were quantitatively measured before and after training related to the proper donning and use of cup or foldable-type respirators. The pass/fail criterion of FF was set at 100. After the donning training for the cup-type mask, fit test were increased by 769%. but foldable-type mask was also increased after the donning training, the GM of FF for the foldable-type mask and it's increase rate were smaller as compared to the cup-type mask. Furthermore, the differences of the increase rates of the GM of FF in employment type of the subjects were not significantly for the foldable-type mask. These results imply that the raining on the donning and use of PFFR can enhance the protection effectiveness of cup or foldable-type mask, and that the training effects for the foldable-type mask is less significant than that for the cup-type mask. Therefore, it is recommended that the donning training and fit tests should be conducted before the use of the PFFR, and listening to workers opinion regularly.

A Study on the Factors Affecting Asbestos Exposure Level from Asbestos Abatement in Building Demolition Sites (석면 해체·제거시 공기 중 노출수준과 영향요인)

  • Kim, Ji-Yeong;Lee, Song-Kwon;Lee, Jeong Hee;Lim, Mu Heok;Kang, Sungwook;Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.1
    • /
    • pp.8-15
    • /
    • 2009
  • This study was examined to find out asbestos exposure level the factors which affected the level at asbestos abatement sites. We visited a total of thirteen building demolition sites(3 apartments, 3 schools, 4 stores, and 3 houses) were visited to collect samples and related data from August to November, 2006. The results of this study were as follows 1. The results of an analysis of bulk samples to identify types of asbestos at the asbestos abatement sites showed that the kinds of the asbestos detected were chrysotile by 50.0%, were tremolite by 2.6%, and were the contents of chrysotile by 3 to 20%. 2. The geometric mean concentration of asbestos was 0.007 f/cc(range 0.001-0.34 f/cc) and its geometric standard deviation was 5.83. Of the samples, however, 12 exceeded the Korean Occupational Exposure Limit(0.1f/cc). 3. Of the materials, textile material had the highest concentration with geometric mean of 0.016 f/cc. When asbestos-containing materials were removed using T type tools, the geometric mean concentration of asbestos was 0.061 f/cc. The level by this method was much higher than by other removal methods. In analysis by the type of building, the geometric mean concentration of asbestos in stores was 0.042 f/cc and was higher than in other buildings. 4. The Poisson regression analysis was applied to find out the factors that affect the airborne asbestos concentration. As a result of the analysis, removal using a T type tool was the most important factor affecting the asbestos concentration(p<0.01). In conclusion, the airborne asbestos concentration(geometric mean) in asbestos abatement sites was 0.007 f/cc(0.001~0.34 f/cc), and 12(14.6%) of all samples were over the 0.1 f/cc. These results showed that asbestos abatement workers have been exposed to the high level of airborne asbestos because they have not been keeping asbestos removal rule. In accordance with increases of the number of building demolition sites, the better government regulation on asbestos abatement methods should be made and be performed well at building demolition sites.

Asbestos Content in Friable Sprayed-on Surface Material and Airborne Fiber Concentrations in Commercial Buildings (대형건물내 비고형 석면함유 건축자재에 의한 기중 석면오염 및 관리실태)

  • Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.137-146
    • /
    • 1995
  • Twenty(20) large commercial buildings located in Seoul with friable sprayed-on surface insulation material on ceilings were investigated for asbestos content in bulk material by polarized light microscopy and for airborne fiber concentrations in buildings by phase contrast microscopy. In addition, such building-related variables as building age, numbers of traffic, airflow, surface conditions of the ceiling, temperature, and humidity were studied for any correlation with airborne fiber concentrations. The results were as follows: 1. Chrysotile asbestos was found in two bulk samples with 3-5% content and with <1%in one sample out of total 20 bulk samples collected. Glass fiber and mineral wool were the two major constituents of the bulk samples. 2. The ceiling surfaces were very friable in 16 buildings and were relatively hard in 4 buildings. The friability of the surface material was dependent upon the type and the amount of binder that had been mixed with the sprayed-on surface material. 3. Airborne fiber concentrations were log-normally distributed and the geometric mean(geometric standard deviation) fiber concentrations in the underground parking lots, inside buildings, and outdoor ambient air were 0.0063(1.97)f/cc, 0.0068(2.29)f/cc, and 0.0033(2.36)f/cc, respectively. 4. No significant relationship of airborne fiber concentrations and all building-related variables studied except humidity was found. The results of this study suggest that the sprayed-on surface insulation material found in some commercial buildings may possibly be contaminated with asbestos. Since most of the ceiling surfaces surveyed were very friable and poorly maintained and the airborne fiber concentrations were relatively high, there is a possibility of asbestos fiber contamination in these buildings, particularly at those buildings with asbestos-contaminated surface material. Since poorly maintained surface conditions were thought to be a source of high airborne fiber concentrations, there is a urgent need of a systematic operation and maintenance program. Further study of non-occupational asbestos exposure in general population utilizing advanced analytical technique such as transmission electron microscopy is highly recommended.

  • PDF

Experiment on Collection Characteristics of Sub micron Particles in Two-Stage Parallel-Plate Electrostatic Precipitators (2단 평행판 전기집진기의 서브마이크론 입자 포집특성 실험)

  • Oh, M.D.;Yoo, K.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.237-246
    • /
    • 1994
  • Experimental data are reported for charging and collection of NaCl aerosols in the 0.03- to $0.2{\mu}m$-geometric-mean-diameter range in 2-stage parallel-plate electrostatic precipitators. The NaCl aerosols are generated with geometric standard deviation of about 1.74 and particle generation rate of about 10^9 particles/see by the constant output atomizer and injected into the air flow in the clean wind-tunnel. The 2-stage parallel-plate electrostatic precipitator installed in the test section of the wind-tunnel is operated with a positive corona discharge. The NaCl aerosols in the channel flow are sampled and transported to the aerosol particle number concentration measurement system by using the isoaxial sampling and transport system constructed based on the Okazaki and Willeke design. The aerosol particle number concentration measurement system measures the size distribution of submicrometer aerosols by an electrical mobility detection technique. It is confirmed from comparing the measured collection efficiencies in this study and the predicted ones by our previous theoretical analysis that the predicted collection efficiencies agree well with the experimental ones. It is also found from the comparison that below about $0.02{\mu}m$ all particles are not charged and the uncharged particles are not collected, and consequently 2-stage parallel-plate electrostatic precipitators are not suitable for that particle size range.

  • PDF

Airborne Nicotine Concentrations in the Workplaces of Tobacco Farmers

  • Yoo, Seok-Ju;Park, Sung-Jun;Kim, Byoung-Seok;Lee, Kwan;Lim, Hyun-Sul;Kim, Jik-Su;Kim, In-Shik
    • Journal of Preventive Medicine and Public Health
    • /
    • v.47 no.3
    • /
    • pp.144-149
    • /
    • 2014
  • Objectives: Nicotine is a natural alkaloid and insecticide in tobacco leaves. Green tobacco sickness (GTS) is known as a disease of acute nicotine intoxication among tobacco farmers. Until now, GTS has been recognized globally as a disease that results from nicotine absorption through the skin. However, we assumed that GTS might also result from nicotine inhalation as well as absorption. We aimed to measure the airborne nicotine concentrations in various work environments of Korean tobacco farmers. Methods: We measured the nicotine concentrations in the tobacco fields, private curing barns, and joint curing barns of farmers from July to October 2010. All sampling and analyses of airborne nicotine were conducted according to the National Institute for Occupational Safety and Health manual of analytic methods. Results: The airborne nicotine concentrations (geometric mean [geometric standard deviation]) in the tobacco field were $83.4mg/m^3$ (1.2) in the upper region and $93.3mg/m^3$(1.2) in the lower region. In addition, the nicotine concentration by personal sampling was $150.1mg/m^3$. Similarly, the nicotine concentrations in the private curing barn, workers in curing barns, the front yard of the curing barn, and in the joint curing barn were $323.7mg/m^3$(2.0), $121.0mg/m^3$(1.5), $73.7mg/m^3$(1.7), and $610.3mg/m^3$(1.0), respectively. Conclusions: The nicotine concentration in the workplaces of tobacco farmers was very high. Future studies should measure the environmental concentration of nicotine that is inhaled by tobacco farmers.