• Title/Summary/Keyword: Geometric aberration

Search Result 5, Processing Time 0.022 seconds

Airborne Infrared Scanning Imaging System with Rotating Drum for Fire Detection

  • Song, c;Chang, Jun;Cao, Jiao;Zhang, Lifei;Wen, Yao;Wei, Aman;Li, Jiang
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.340-344
    • /
    • 2011
  • Airborne infrared techniques have been used in wild land fire management for decades. This paper describes a kind of infrared scanning system based on a rotating drum with a tilted porthole underside the plane nose. This design increases the stability of the mechanism system, reduces air resistance and protects inner parts. Aberration characteristics of a tilted ellipsoid porthole are analyzed and an effective solution is invented which makes the system achieve $30^{\circ}$ field of regard. The system's ultimate value of modulation transfer function is near the diffraction limit, which indicates that the performance of the rotating optical system meets the imaging requirements.

Characteristic Evaluation of Optical Design Using Dimensionless Design Parameters (무차원의 설계변수를 이용한 광학설계의 특성 평가)

  • Lee, Jong-Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.1
    • /
    • pp.35-44
    • /
    • 2022
  • Since optical systems are used for various applications, there are many designs, depending on the purpose and optical specifications, even though they have similar formations. Optical aberrations of a system are affected by both structure and specifications. Thus, it is very difficult to find the special characteristics of an optical design by using aberration analysis only. Regardless of specifications, a new method to investigate the aberration characteristics of an optical design is presented, using dimensionless design parameters. Four kinds of triplet designs with different applications and specifications are analyzed as examples.

Transparent Plate Thickness Measurement Approach Using a Chromatic Confocal Sensor Based on a Geometric Phase Lens (기하 위상 렌즈 기반의 색공초점 센서를 이용한 투명 물질 두께 측정 연구)

  • Song, Min Kwan;Park, Hyo Mi;Joo, Ki-Nam
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.317-323
    • /
    • 2022
  • In this investigation, we describe a chromatic confocal sensor based on a geometric phase lens for measuring the thicknesses of transparent plates. In order to design a compact sensor, a geometric phase lens, which has diffractive and polarizing characteristics, is used as a device to generate chromatic aberration, and a fiber optic module is adopted. The systematic error of the sensor is reduced with wavelength peak detection by Gaussian curve fitting and the common error compensation obtained by the repeatedly consecutive experimental results. An approach to calculate the plate thickness is derived and verified with sapphire and BK7 plates. Because of the simple and compact design of the proposed sensor with rapid measurement capability, it is expected to be widely used in thickness measurements of transparent plates as an alternative to traditional approaches.

Evaluation of Genotoxicity of CP Pharmacopuncture Using an In Vitro Chromosome Aberration Test in Chinese Hamster Lung Cell (Chinese Hamster Lung 세포를 이용한 염색체이상 시험을 이용한 CP약침의 유전독성평가)

  • Hwang, Ji Hye;Jung, Chul;Ku, Jaseung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.34 no.6
    • /
    • pp.355-361
    • /
    • 2020
  • This study was designed to assess the toxicity of capsaicin-containing (CP) pharmacopunture using an in vitro chromosomal aberrations in Chinese hamster lung (CHL/IU) cells. In order to determine the high dose level in the main study of this study, a dose range finding study was conducted first. The high dose was selected at 10.0% of CP pharmacopuncture extract, and then diluted sequentially to produce lower dose levels of 5.00, 2.50, 1.25, 0.625 and 0.313% by applying a geometric ratio of 2. As a result, the cytotoxicity and precipitation of the CP pharmacopuncture as a test substance were not evident at any dose level during short-time treatment with and without metabolic activation and continuous treatment without metabolic activation. Therefore, the dose levels for this study were chosen as 10.0, 5.0, and 2.5%., and the treatment volume was 1.3 mL. In addition, negative and positive controls were set. In main study, the frequency of cells with chromosome aberrations in CP treated groups was less than 5% in short-time treatment with and without metabolic activation and continuous treatment without metabolic activation. In addition, there was no statistically significant difference when compared to the negative control group. The frequency of cells with structural chromosomal aberrations in the positive control group was more than 10% compared to the negative control group, and it increased statistically significantly. In conclusion, under the conditions of this study, CP pharmacopuncture did not show the possibility of causing chromosome aberrations.

Large-view-volume Multi-view Ball-lens Display using Optical Module Array (광학 모듈 어레이를 이용한 넓은 시야 부피의 다시점 볼 렌즈 디스플레이)

  • Gunhee Lee;Daerak Heo;Jeonghyuk Park;Minwoo Jung;Joonku Hahn
    • Journal of Broadcast Engineering
    • /
    • v.28 no.1
    • /
    • pp.79-89
    • /
    • 2023
  • A multi-view display is regarded as the most practical technology to provide a three-dimensional effect to a viewer because it can provide an appropriate viewpoint according to the observer's position. But, most multi-view displays with flat shapes have a disadvantage in that a viewer watches 3D images only within a limited front viewing angle. In this paper, we proposed a spherical display using a ball lens with spherical symmetry that provides perfect parallax by extending the viewing zone to 360 degrees. In the proposed system, each projection lens is designed to be packaged into a small modular array, and the module array is arranged in a spherical shape around a ball lens to provide vertical and horizontal parallax. Through the applied optical module, the image is formed in the center of the ball lens, and 3D contents are clearly imaged with the size of about 0.65 times the diameter of the ball lens when the viewer watches them within the viewing window. Therefore, the feasibility of a 360-degree full parallax display that overcomes the spherical aberration of a ball lens and provides a wide field of view is confirmed experimentally.