• Title/Summary/Keyword: Geometric Characteristics

Search Result 1,375, Processing Time 0.029 seconds

Methacholine and adenosine 5'-monophosphate challenge tests in children with atopic asthma and with nonatopic asthma, and their relationships to blood eosinophil markers. (아토피성 천식 환아와 비아토피성 천식 환아에서 메타콜린과 아데노신 기관지 유발 검사의 비교 및 혈중 호산구 염증 지표와의 관련성)

  • Lee, Sun Hee;Kim, Do Kyun;Choi, Sun Hee;Koh, Young Yull
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.11
    • /
    • pp.1216-1222
    • /
    • 2006
  • Purpose : Though atopic and nonatopic asthma have different clinical manifestations, bronchial hyperresponsiveness (BHR) and airway inflammations are common characteristics of them. We investigated BHR to both methacholine and adenosine 5'-monophosphate (AMP), and their relationships with blood eosinophil markers in nonatopic asthma as well as atopic asthma. Methods : We studied 116 children (82 atopics; 34 nonatopics) with mild to moderate asthma. Methacholine and AMP challenge tests were performed and bronchial responsiveness was expressed as $PC_{20}$ (provocative concentration causing a 20 percent fall in $FEV_1$); blood eosinopil counts (ETCs) and serum eosinophil cationic protein (ECP) levels were gauged. Results : In atopics, 95.1 percent and 90.2 percent showed hyperreactivity to methacholine ($PC_{20}$<16 mg/mL) and AMP ($PC_{20}$<200 mg/mL), respectively. Meanwhile, in nonatopics, 94.1 percent and 52.9 percent displayed hyperreactivity to methacholine and AMP, respectively. The geometric mean of AMP $PC_{20}$ was lower in atopics (31.6 mg/mL) than in nonatopics (125.9 mg/mL); that of methacholine $PC_{20}$ was similar in the two groups. AMP $PC_{20}$ correlated with blood ETCs in both atopics(r=-0.30, P<0.01) and nonatopics (r=-0.57, P<0.01), and correlated with serum ECP levels (r=-0.23, P<0.01) in atopics, but not in nonatopics. Apart from AMP, methacholine $PC_{20}$ was not associated with blood eosinophil markers in either group. Conclusion : Atopics more frequently displayed BHR to AMP than nonatopics. Furthermore, BHR to AMP was associated with not only blood ETCs, but serum ECP levels in atopics but was correlated with only blood ETCs in nonatopics. Those results suggest that BHR to AMP reflects airway inflammation in asthma and is more related to atopy.

Comparison of Electrical Signal Properties about Top Electrode Size on Photoconductor Film (광도전체 필름 상부 전극크기에 따른 전기적 신호 특성 비교)

  • Kang, Sang-Sik;Jung, Bong-Jae;Noh, Si-Cheul;Cho, Chang-Hoon;Yoon, Ju-Sun;Jeon, Sung-Pyo;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.93-96
    • /
    • 2011
  • Currently, the development of direct conversion radiation detector using photoconductor materials is progressing in widely. Among of theses photoconductor materials, mercuric iodide compound than amorphous selenium has excellent absorption and sensitivity of high energy radiation. Also, the detection efficiency of signal generated in photoconductor film varies by electric filed and geometric distribution according to top-bottom electrode size. Therefore, in this work, the x-ray detection characteristics are investigated about the size of top electrode in $HgI_2$ photoconductor film. For sample fabrication, to solve the problem that is difficult to make a large area film, we used the spatial paste screen-print method. And the sample thickness is $150{\mu}m$ and an film area size is $3cm{\times}3cm$ on ITO-coated glass substrate. ITO(Indium-Tin-Oxide) electrode was used as top electrode using a magnetron sputtering system and each area is $3cm{\times}3cm$, $2cm{\times}2cm$ and $1cm{\times}1cm$. From experimental measurement, the dark current, sensitivity and SNR of the $HgI_2$ film are obtained from I-V test. From the experimental results, it shows that the sensitivity increases in accordance with the area of the electrode but the SNR is decreased because of the high dark current. Therefore, the optimized size of electrode is importance for the development of photoconductor based x-ray imaging detector.

A Study on the Concentration of Nanoparticles and Heavy Metals in Indoor/Outdoor Air in a University Administrative Public Office (대학교 행정실 실내 외 공기 중 나노입자와 중금속 농도에 관한 연구)

  • Choi, Su-Hyeon;Im, Ji-Young;Park, Hee-Jin;Chung, Eun-Kyung;Kim, Jong-Oh;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.6
    • /
    • pp.493-502
    • /
    • 2012
  • Objectives: The purpose of this study is to investigate the mass concentration of nanoparticles and understand the characteristics of elements of heavy metal concentrations within nanoparticles in the air using Micro-Orifice Uniform Deposit Impactor Model-110 (MOUDI-110), based on indoor and outdoor air. Methods: This Study sampled nanoparticles using MOUDI-110 indoors (office) and outdoors at S University in Asan, Korea in order to reveal the concentration of nanoparticles in the air. Sampling continued for nine months (10 times indoors and 14 times outdoors) from March to November 2010. Mass concentrations of nanoparticle and concentrations of heavy metals (Al, Mn, Zn, Ni, Cu, Cr, Pb) were analyzed. Results: Indoors, geometric mean concentration of nanoparticles ranged in size from 0.056 ${\mu}m$ to 0.10 ${\mu}m$ and those of 0.056 ${\mu}m$ or less recorded 0.929 ${\mu}g/m^3$ and 1.002 ${\mu}g/m^3$, respectively. On the other hand, the levels were lower outdoors with 0.819 ${\mu}g/m^3$ and 0.597 ${\mu}g/m^3$. Mann-Whitney U tests showed that the difference between the indoors and the outdoors was statistically meaningful in terms of particles of 0.056 ${\mu}m$ or less (p<0.05) in size. These results are possibly influenced by the use of printers and duplicators as the factor that increased the concentration of nanoparticles. In seasonal concentration distribution, the level was higher during the summer compared to in the autumn. Those of 0.056 ${\mu}m$ or less in size presented a statistically meaningful difference during the summer (p<0.05). These results may be influenced by photochemical event as the factor that makes the levels high. Regarding zinc, among the other heavy metals, the fine particles ranged in size from 0.056 ${\mu}m$ to 0.10 ${\mu}m$ and those of 0.056 ${\mu}m$ or less recorded 1.699 $ng/m^3$ and 1.189 $ng/m^3$ in the outdoors. In the indoors, the levels were lower, with 0.745 $ng/m^3$ and 0.617 $ng/m^3$. Cr and Ni at the size of 0.056 ${\mu}m$ or less, both of which have been known to pose severe health effects, recorded higher concentrations indoors with 0.736 $ng/m^3$ and 0.177 $ng/m^3$, compared to 0.444 $ng/m^3$ and 0.091 $ng/m^3$ outdoors. By season, Zn, Ni, Cu and Pb posted a high level of indoor concentration during the fall. As for Cr, the level of concentration indoors was higher than outdoors both during the summer and the autumn. Conclusion: This study indicates the result of an examination of nano-sized particles and heavy metal concentrations. It will provide useful data for the determination of basic nanoparticle standards in the future.

A Review on Ultimate Lateral Capacity Prediction of Rigid Drilled Shafts Installed in Sand (사질토에 설치된 강성현장타설말뚝의 극한수평지지력 예측에 관한 재고)

  • Cho Nam Jun;Kulhawy F.H
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.2
    • /
    • pp.113-120
    • /
    • 2005
  • An understanding of soil-structure interaction is the key to rational and economical design for laterally loaded drilled shafts. It is very difficult to formulate the ultimate lateral capacity into a general equation because of the inherent soil nonlincarity, nonhomogeneity, and complexity enhanced by the three dimensional and asymmetric nature of the problem though extensive research works on the behavior of deep foundations subjected to lateral loads have been conducted for several decades. This study reviews the four most well known methods (i.e., Reese, Broms, Hansen, and Davidson) among many design methods according to the specific site conditions, the drilled shaft geometric characteristics (D/B ratios), and the loading conditions. And the hyperbolic lateral capacities (H$_h$) interpreted by the hyperbolic transformation of the load-displacement curves obtained from model tests carried out as a part of this research have been compared with the ultimate lateral capacities (Hu) predicted by the four methods. The H$_u$ / H$_h$ ratios from Reese's and Hansen's methods are 0.966 and 1.015, respectively, which shows both the two methods yield results very close to the test results. Whereas the H$_u$ predicted by Davidson's method is larger than H$_h$ by about $30\%$, the C.0.V. of the predicted lateral capacities by Davidson is the smallest among the four. Broms' method, the simplest among the few methods, gives H$_u$ / H$_h$ : 0.896, which estimates the ultimate lateral capacity smaller than the others because some other resisting sources against lateral loading are neglected in this method. But it results in one of the most reliable methods with the smallest S.D. in predicting the ultimate lateral capacity. Conclusively, none of the four can be superior to the others in a sense of the accuracy of predicting the ultimate lateral capacity. Also, regardless of how sophisticated or complicated the calculating procedures are, the reliability in the lateral capacity predictions seems to be a different issue.

Relationship Between Airway Inflammation Assessed by Induced Sputum and Airway Hyperresponsiveness in Asthmatic Patient (기관지천식 환자에서 유도객담으로 평가한 기도염증과 기관지 과민성과의 관계)

  • Chung, Lee-Young;Kim, Hyun-Jin;Jeong, Gyeong-Won;Kang, Mi-Jeong;Kim, Hwi-Jong;Chung, Hyo-Young;Lee, Jong-Deog;Hwang, Young-Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.4
    • /
    • pp.517-524
    • /
    • 1999
  • Background : Airway inflammation and hyperresponsiveness are recognized as major characteristics of bronchial asthma. Airway inflammation has usually been assessed by invasive methods, e.g. BAL or bronchial biopsy, but recent studies proposed induced sputum as another reliable and non-invasive tool to investigate airway inflammation in asthmatic patients. Thus, the relationship between airway inflammation assessed by induced sputum and airway hyperresponsiveness was investigated in asthmatic patient. Method : Airway responsiveness was determined by the concentration that caused a 20% decrease in $FEV_1$($PC_{20}$) after inhaling incremental concentrations of methacholine. The numbers of inflammatory cells and the concentration of eosinophilic cationic protein(ECP) were assessed in induced sputum obtained by inhalation of hypertonic saline(3%). Result: We analyzed sputum induced in 15 stable asthmatic patients. The differential cell count(%) of macrophages, neutrophils, eosinophils and lymphocytes in induced sputum were $39.1{\pm}27.0%$, $29.6{\pm}21.0%$, $28.8{\pm}18.8%$, $1.3{\pm}3.1%$ respectively. The mean value of baseline FEV1(predicted) and ECP were $76.3{\pm}30.3%$ and $1,101{\pm}833{\mu}g/L$ respectively. The geometric mean value of $PC_{20}$ was 0.56 mg/mL. The relationships between the sputum eosinophil and ECP in induced sputum, and between sputum eosinophil and degree of airway responsiveness($PC_{20}$) were found to be significantly correlated (r=0.81, p<0.05 and r=-0.78, p<0.05, respectively). Sputum neutrophils and $PC_{20}$ were not correlated to each other (r=0.11, p=0.69) and a significant negative correlation was found between ECP and baseline $FEV_1$(predicted)(r=-0.62, p<0.05). Conclusion : The results of this study suggest that an induced sputum via a inhalation of hypertonic saline is useful to determine a patient's status of airway inflammation, and airway inflammation is one of the major causal factors in the development of bronchial hyperresponsiveness in asthmatic patients.

  • PDF

Manufacturing and Establishment of the 2nd National Standard for Varicella Vaccine (수두생바이러스백신 국가표준품 (2차) 제조 및 확립에 관한 연구)

  • Kim, Yeon-Hee;Kim, Do-Keun;Sohn, Yeo-Won;Han, Eui-Ri;Kim, Seok-Hwan;Lim, Jong-Mi;Won, Yun-Jung;Yoon, Heui-Seong;Jo, Moon-Hee;Kim, Kwan-Soo;Kim, Jae-Ok
    • KSBB Journal
    • /
    • v.25 no.6
    • /
    • pp.572-576
    • /
    • 2010
  • Biological products, such as live varicella vaccine, are composed of biological substances derived from biological organisms. It is very difficult to identify these biologics' characteristics by analysis of simple physical and chemical methods alone. So the reference material is essential in order to evaluate the quality of bilogics. The 1'st national standard for varicella live vaccine was manufactured, established in 2002 and 2003, and have been used for the manufacturer's quality control and national lot release since then. As the lack of its availability and the decrease of its stability, this study was initiated by National Institute of Food and Drug Safety Evaluation (NiFDS) in 2008 to manufacture and establish the 2nd national standard for varicella live vaccine. The candidate material was manufactured from one of domestic manufacterers and the joint research of the NiFDS and manufacturers of varicella live vaccine was conducted to estimate of the reliable virus content. In the collaborative study, 3 laboratories including NiFDS performed the virus content test more than 7 times and all assay results were statistically analyzed. The mean coefficient of variation (CV) was 1.24%, and the geometric mean titre (GMT) variation range of each laboratory was low. On the basis of the results of this study, the candidate material of 2nd national standard for varicella live vaccine was assigned a potency of 4.26 log10 pfu/0.5 mL, when reconstituted in 0.7 mL.

Development of KD- Propeller Series using a New Blade Section (새로운 날개단면을 이용한 KD-프로펠러 씨리즈 개발)

  • J.T. Lee;M.C. Kim;J.W. Ahn;H.C. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.28 no.2
    • /
    • pp.52-68
    • /
    • 1991
  • A new propeller series is developed using the newly developed blade section(KH18 section) which behaves better cavitation characteristics and higher lift-drag ratio at wide range of angle-of-attack. The pitch and camber distributions are disigned in order to have the same radial and chordwise loading distribution with the selected circumferentially averaged wake input. Since the geometries of the series propeller, such as chord length, thickness, skew and rate distribations, are selected by regression of the recent full scale propeller geometric data, the performance prediction of a propeller at preliminary design stage can be mure realistic. Number of blades of the series propellers is 4 and the expanded blade area ratios are 0.3, 0.45, 0.6 and 0.75. Mean pitch ratios are selected as 0.5, 0.65, 0.8, 0.75 and 1.1 for each expanded area ratio. The new propeller series is composed of 20 propellers and is named as KD(KRISO-DAEWOO) propeller series. Propeller open water tests are performed at the experimental towing tank, and the cavitation observation tests and fluctuating pressure measurements are carried out at the cavitation tunnel of KRISO. $B_{P}-\delta$ curves, which can be used to select the optimum propeller diameter at the preliminary design stage, are derived from a regression analysis of the propeller often water test results. The KD-cavitation chart is derived from the cavitation observation test results by choosing the local maximum lift coefficient and the local cavitation number as parameters. The caviy extent of a propeller can be predicted more accurately by using the KD-cavitation chart at a preliminary design stage, since it is derived from the results of the cavitation observation tests in the selected ship's wake, whereas the existing cavitation charts, such as the Burrill's cavitation chart, are derived from the test results in uniform flow.

  • PDF

Comparison of the SNR in the MR images on dental implant material (치아 임플란트 재료에 따른 자기공명영상의 SNR 비교)

  • Kim, Dong-Hyun;Ko, Seong-Jin;Ye, Soo-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.4
    • /
    • pp.149-155
    • /
    • 2015
  • Tooth implant is located in oral cavity and affects neck, skull base, and facail image. These magnetic inhomogeneities are usually frequency encoding direction which cause artifacts due to change of signal strength and geometric distortion. First, to evaluate signal to noise ratio (SNR) of magnetic resonance image caused by tooth implant this study uses meat phantom which is similar to human body and is consisted with fat, muscle, and water to measure signal to noise ratio. Second, signal to noise ratio by using custom-made fixed phantom is measured, and then signal to noise ratio size of different tooth implant types is compared and analyzed. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for meat phantom were 2.76, 2.22, 1.88, and 1.57 on T1 SE, 1.88, 1.78, 1.65, and 1.79 on T2 FLAIR, 2.28, 2.25, 2.88, and 2.05 on T2 FSE, and 2.74, 1.94, 1.67, and 1.48 on T2 GRE. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for fixed water phantom were 1.2, 1.06, 1.12, and 1.22 on DWI, 1.93, 1.87, 1.93, and 2.06 T1 SE, 1.83, 1.76, 1.82, and 1.92 on T2 FLAIR, 1.85, 1.79, 7.86, and 1.97 on T2 FSE, and 1.97, 1.93, 1.99, and 2.06 on T2 GRE. By considering through the results, patients and dentists need to consider some impacts from testing many aspects although their main purpose of having tooth implants is a dental restoration. Moreover, depending on the tooth implant characteristics of individual patients this study results can be used as baseline data when choosing test protocol.

Investigation of Intertidal Zone using TerraSAR-X (TerraSAR-X를 이용한 조간대 관측)

  • Park, Jeong-Won;Lee, Yoon-Kyung;Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.4
    • /
    • pp.383-389
    • /
    • 2009
  • The main objective of the research is a feasibility study on the intertidal zone using a X-band radar satellite, TerraSAR-X. The TerraSAR-X data have been acquired in the west coast of Korea where large tidal flats, Ganghwa and Yeongjong tidal flats, are developed. Investigations include: 1) waterline and backscattering characteristics of the high resolution X-band images in tidal flats; 2) polarimetric signature of halophytes (or salt marsh plants), specifically Suaeda japonica; and 3) phase and coherence of interferometric pairs. Waterlines from TerraSAR-X data satisfy the requirement of horizontal accuracy of 60 m that corresponds to 20 cm in average height difference while current other spaceborne SAR systems could not meet the requirement. HH-polarization was the best for extraction of waterline, and its geometric position is reliable due to the short wavelength and accurate orbit control of the TerraSAR-X. A halophyte or salt marsh plant, Suaeda japonica, is an indicator of local sea level change. From X-band ground radar measurements, a dual polarization of VV/VH-pol. is anticipated to be the best for detection of the plant with about 9 dB difference at 35 degree incidence angle. However, TerraSAR-X HH/TV dual polarization was turned to be more effective for salt marsh monitoring. The HH-HV value was the maximum of about 7.9 dB at 31.6 degree incidence angle, which is fairly consistent with the results of X-band ground radar measurement. The boundary of salt marsh is effectively traceable specifically by TerraSAR-X cross-polarization data. While interferometric phase is not coherent within normal tidal flat, areas of salt marsh where the landization is preceded show coherent interferometric phases regardless of seasons or tide conditions. Although TerraSAR-X interferometry may not be effective to directly measure height or changes in tidal flat surface, TanDEM-X or other future X-band SAR tandem missions within one-day interval would be useful for mapping tidal flat topography.

Research on Earthquake Occurrence Characteristics Through the Comparison of the Yangsan-ulsan Fault System and the Futagawa-Hinagu Fault System (양산-울산 단층계와 후타가와-히나구 단층계의 비교를 통한 지진발생특성 연구)

  • Lee, Jinhyun;Gwon, Sehyeon;Kim, Young-Seog
    • The Journal of the Petrological Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.195-209
    • /
    • 2016
  • The understanding of geometric complexity of strike-slip Fault system can be an important factor to control fault reactivation and surface rupture propagation under the regional stress regime. The Kumamoto earthquake was caused by dextral reactivation of the Futagawa-Hinagu Fault system under the E-W maximum horizontal principal stress. The earthquakes are a set of earthquakes, including a foreshock earthquake with a magnitude 6.2 at the northern tip of the Hinagu Fault on April 14, 2016 and a magnitude 7.0 mainshock which generated at the intersection of the two faults on April 16, 2016. The hypocenters of the main shock and aftershocks have moved toward NE direction along the Futagawa Fault and terminated at Mt. Aso area. The intersection of the two faults has a similar configuration of ${\lambda}$-fault. The geometries and kinematics, of these faults were comparable to the Yansan-Ulsan Fault system in SE Korea. But slip rate is little different. The results of age dating show that the Quaternary faults distributed along the northern segment of the Yangsan Fault and the Ulsan Fault are younger than those along the southern segment of the Yansan Fault. This result is well consistent with the previous study with Column stress model. Thus, the seismic activity along the middle and northern segment of the Yangsan Fault and the Ulsan Fault might be relatively active compared with that of the southern segment of the Yangsan Fault. Therefore, more detailed seismic hazard and paleoseismic studies should be carried out in this area.