• Title/Summary/Keyword: Generators

Search Result 1,904, Processing Time 0.028 seconds

The Evaluation of Usefulness of Two Times Elution a Day of $^{99m}Tc$ Using $^{99}Mo$-$^{99m}Tc$ Generator ($^{99m}Tc$ 발생기의 24시간 내 2회 용출의 유용성 평가)

  • Kim, Jeong-Ho;Seo, Han-Kyung;Jeong, Yeong-Hwan;Kim, Yeong-Su;Kim, Byung-Cheol;Gwon, Yong-Ju;Lee, Jeong-Ok;Park, Yeong-Sun;Kim, Dong-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.83-86
    • /
    • 2010
  • Purpose: The Molybdenum which is the raw material of $^{99}Mo$-$^{99m}Tc$ generator (generator) is produced from the nuclear reactor. However, output has dwindled as the two nuclear reactors supplying the bulk of radioactive material-one in Chalk River, Ontario and the other in Petten, the Netherlands-have been closed for repairs or maintenance. This resulted in the enhancement of its price. Therefore we have tried to seek the new method which could run generator to increase activity of $^{99m}Tc$ in this study. Materials and Methods: The $^{99m}Tc$ activity obtained from 5 times elution for 5 days from Monday to Friday using two generators was compared with 10 times elution. Appearance test, pH test, LAL test, sterility test, chemical impurity(Al) test, radio chemical purity test, ratio of $^{99}Mo$/$^{99m}Tc$ activity test have been done to check the stability of $^{99m}Tc$ eluting from generator respectively. Results: The $^{99m}Tc$ activity obtained from 5 times elution for 5 days was 168.2 GBq (4545 mCi) and 10 times was 230.5 GBq (6230 mCi). All quality control tests were within normal limit. Conclusion: We got to know that 2 times elution a day obtained more $^{99m}Tc$ activity than one time elution in this study.

  • PDF

A Study on the Power Supply and Demand Policy to Minimize Social Cost in Competitive Market (경쟁시장 하에서 사회적 비용을 고려한 전력수급정책 방향에 관한 연구)

  • Kwon, Byung-Hun;Song, Byung Gun;Kang, Seung-Jin
    • Environmental and Resource Economics Review
    • /
    • v.14 no.4
    • /
    • pp.817-838
    • /
    • 2005
  • In this paper, the resource adequacy as well as the optimum fuel mix is obtained by the following procedures. First, the regulation body, the government agency, determine the reliability index as well as the optimum portfolio of the fuel mix during the planning horizon. Here, the resources with the characteristics of public goods such as demand-side management, renewable resources are assigned in advance. Also, the optimum portfolio is determined by reflecting the economics, environmental characteristics, public acceptance, regional supply and demand, etc. Second, the government announces the required amount of each fuel-type new resources during the planning horizon and the market participants bid to the government based on their own estimated fixed cost. Here, the government announces the winners of the each auction by plant type and the guaranteed fixed cost is determined by the marginal auction price by plant type. Third, the energy market is run and the surplus of each plant except their cost (guaranteed fixed cost and operating cost) is withdrew by the regulatory body. Here, to induce the generators to reduce their operating cost some incentives for each generator is given based on their performance. The performance is determined by the mechanism of the performance-based regulation (PBR). Here the free-riding performance should be subtracted to guarantee the transparent competition. Although the suggested mechanism looks like very regulated one, it provides two mechanism of the competition. That is, one is in the resource construction auction and the other is in the energy spot market. Also the advantages of the proposed method are it guarantee the proper resource adequacy as well as the desired fuel mix. However, this mechanism should be sustained during the transient period of the deregulation only. Therefore, generation resource planning procedure and market mechanisms are suggested to minimize possible stranded costs.

  • PDF

Effects of Contrast Improvement on High Voltage Rectification Type of X-ray Diagnostic Apparatus (X선 진단장치의 고압정류방식이 대조도 향상에 미치는 영향)

  • Lee, Hoo-Min;Yoon, Joon;Kim, Hyun-Ju
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.187-193
    • /
    • 2014
  • The purpose of this study was to analyze the effect on the selectivity on of high-voltage rectification device that measured the performance of the grid, and the contrast improvement ability (K factor) by measuring the scattered radiation content of the transmitted X-rays. The scattered radiation generated when the X-ray flux comes from the diagnostic X-ray generator that passes through an object. Targeting four different rectifications of X-ray generators, the mean value of the tube voltage and the tube current was measured in order to maximize the accuracy of the generating power dose within the same exposure condition. Using fluorescence meter, the content of the scattered rays that are transmitted through the acrylic was measured depending on the grid usage. When grid is not used, the content of the scattered rays was the lowest (34.158%) with the single-phase rectifier, was increased with the inverter rectifier (37.043%) and the three-phase 24-peak rectification method (37.447%). The difference of the scattered radiation content of each device was significant from the lowest 0.404% to the highest 3.289% while using 8:1 grid, the content of the scattered ray was the lowest with the single content of the scattered ray was the lowest with the single-phase rectifier (18.258%), was increased with the rectifier (25.502%) and the 24-peaks rectification (24.217%). Furthermore, there was difference up to content 7.244% to the lowest content 1.285% within three-phase 24-peaks rectification, inverter rectifications, and single-phase rectifier depending on the selectivity of the grid. Drawn from the statistical analysis, there was a similar relationship between the contrast improvement factor and the K factor. As a result, the grid selectivity and the contrast were increased within the single-phase rectifier rather than the constant voltage rectifier.

Dynamic Economic Load Dispatch Problem Applying Valve-Point Balance and Swap Optimization Method (밸브지점 균형과 교환 최적화 방법을 적용한 동적경제급전문제)

  • Lee, Sang-Un
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.253-262
    • /
    • 2016
  • This paper proposes a balance-swap method for the dynamic economic load dispatch problem. Based on the premise that all generators shall be operated at valve-points, the proposed algorithm initially sets the maximum generation power at $P_i{\leftarrow}P_i^{max}$. As for generator i with $_{max}c_i$, which is the maximum operating cost $c_i=\frac{F(P_i)-F(P_{iv_k})}{(P_i-P_{iv_k})}$ produced when the generation power of each generator is reduced to the valve-point $v_k$, the algorithm reduces i's generation power down to $P_{iv_k}$, the valve-point operating cost. When ${\Sigma}P_i-P_d$ > 0, it reduces the generation power of a generator with $_{max}c_i$ of $c_i=F(P_i)-F(P_i-1)$ to $P_i{\leftarrow}P_i-1$ so as to restore the equilibrium ${\Sigma}P_i=P_d$. The algorithm subsequently optimizes by employing an adult-step method in which power in the range of $_{min}\{_{max}(P_i-P_i^{min}),\;_{max}(P_i^{max}-P_i)\}$>${\alpha}{\geq}10$ is reduced by 10; a baby step method in which power in the range of 10>${\alpha}{\geq}1$ is reduced by 1; and a swap method for $_{max}[F(P_i)-F(P_i-{\alpha})]$>$_{min}[F(P_j+{\alpha})-F(P_j)]$, $i{\neq}j$ of $P_i=P_i{\pm}{\alpha}$, in which power is swapped to $P_i=P_i-{\alpha}$, $P_j=P_j+{\alpha}$. It finally executes minute swap process for ${\alpha}=\text{0.1, 0.01, 0.001, 0.0001}$. When applied to various experimental cases of the dynamic economic load dispatch problems, the proposed algorithm has proved to maximize economic benefits by significantly reducing the optimal operating cost of the extant Heuristic algorithm.

A Study on the Utilization of Diagnostic Equipments and Patient Dose for Diagnostic Radiological Procedures in Korea (진단방사선영역에서 방사선장치의 이용실태 및 환자피폭선량에 관한 조사연구)

  • Kim Youhyun;Choi Jonghak;Kim Sungsoo;Lee Chanhyeup;Cho Pyongkon;Lee Youngbae;Kim Chelmin
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.10-15
    • /
    • 2005
  • IAEA's guidance levels have been provided for western people to the end. Guidance levels lower than the IAEA'S will be necessary in view of Korean people's proportions. Therefore, we need to develope the standard doses for Korean people. And we conducted a nationwide survey of patient dose from x-ray examinations in Korea. In this study, the 278 institutions were selected from Members Book of Korean Hospital Association. The valid response rate was approximately 57.9%. Doses were calculated from the questionnaires by NDD method. We obtained the results were as follows; 1) General radiographic equipments were distributed for 42.0%, fluoroscopic equipments 29.4%, dental equipments 13.2%, CT units 8.1 % and mamographic units 7.2%. 2) According to classification by rectification, three-phase equipments were 29.9%, inverter-type generators 29.5%, single-phase equipments 25.5%, constant voltage units 9.0% and unknown units 6.0%. 3) According to classification by receptor system, film-screen types were 46.8%, CR types 26.8%, DR types 17.7% and unknown types 8.9%. 4) The number of examinations were chest 49.2%, spine 16.8% and abdomen 12.7%. 5) Patient doses were head AP 3.44 mGy, abdomen AP 4.25 mGy and chest PA 0.39 mGy.

  • PDF

Analysis of source localization of P300 in college students with schizotypal traits (조현형 인격 성향을 가진 대학생의 P300 국소화 분석)

  • Jang, Kyoung-Mi;Kim, Bo-Mi;Na, Eun-Chan;An, Eun-Ji;Kim, Myung-Sun
    • Korean Journal of Cognitive Science
    • /
    • v.28 no.1
    • /
    • pp.1-26
    • /
    • 2017
  • This study investigated the cortical generators of P300 in college students with schizotypal traits by using an auditory oddball paradigm, event-related potentials (ERPs) and standardized low resolution brain electromagnetic tomography (sLORETA) model. We also investigated the relationship between the current density of P300 and the clinical symptoms of schizophrenia. Based on the scores of Schizotypal Personality Questionnaire(SPQ), schizotypal trait (n=37) and control (n=42) groups were selected. For the measurement of P300, an auditory oddball paradigm, in which frequent standard tones (1000Hz) and rare target tones (1500Hz) were presented randomly, was used. Participants were required to count the number of the target tones during the task and report this at the end of the experiment. The two groups did not differ significantly in the accuracy of the oddball task. The schizotypal trait group showed significantly smaller P300 amplitudes than control group. In terms of source localization, both groups showed the P300 current density over bilateral frontal, parietal, temporal and occipital lobes. However, the schizotypal trait group showed significantly reduced activations in the left superior temporal gyrus and the right middle temporal gyrus, but increased activations in both left inferior frontal gyrus and right superior frontal gyrus compared to the control group. Furthermore, a negative correlation between the current density of the right superior frontal gyrus and SPQ disorganization score was found in the schizotypal trait group. These findings indicate that the individuals with schizotypal traits have dysfunctions of frontal and temporal areas, which are known to be the source of P300, as observed in patients with schizophrenia. In addition, the present results indicate that the disorganization score, rather than total score, of the SPQ is useful in predicting the risk of future schizophrenia.

A Study on the Environmental Condition and Safety in Dental Radiography Room (치과방사선 촬영실의 환경 및 안전성에 관한 연구)

  • Park, Il-Soon;Lee, Kyung-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.49-64
    • /
    • 2004
  • This study is designed to conduct a questionnaire research into the safety control and the actual condition of radiography by working with dentistry belonging to university hospitals, dental hospitals and dental clinics for three months ranging from August, 2003 to October, 2003. The researcher came to the following conclusions. 1. The research on the current condition of possessed radiational equipment shows that 61.2 percent of the subjects had one intraoral radiation medicine and that 70.1 percent of the subjects had more than one extraoral radiation medicine and that 37.3 percent of the subjects had more than one digital radiation medicine. 2. Most of intraoral radiography (82.1%) was conducted by dental hygienists, and 7.5 percent of intraoral radiography was conducted by nurse aids. On the other hand, most of extraoral radiography (76.6%) was conducted by dental hygienists and digital radiography was conducted by dental hygienists(60.6%), dentists(32.0%) and radiographer(80.0%). 3. The less-than 1-meter-long distance between cone and the radiographer accounted for 44.8 percent. And the more-than 1.6-meter-long distance accounted for no more than 13.4 percent. The exposure time per standard film which was adjusted to each part accounted for 71.6 percent. Fixing the film on the part of healthy patients accounted for 76.1 percent. Fixing the film of elderly patients and children patients by the radiographer accounted for 43.3 percent. 4. The average daily photographing frequency of standard films stood at six to ten pieces(31.3%), and the average weekly photographing frequency of bitewing films stood at less than one piece(47.8%), and the dentistries where bitewing films were not employed accounted for 25.4%. The subjects whose average weekly photographing freqeuncy of occlusal films stood at less than a piece accounted for 59.7 percent. The dentistries whose average weekly photographing frequency of pediatric films stood at one to five pieces accounted for 41.8 percent. In case of panorama & cephalo, one to five pieces on a weekly average accounted for 36.2 percent. The dentistries whose average daily photographing frequency of digital radiation medicine stood at less than 1 piece accounted for 40.0 percent. 5. The research on the use of protective clothes shows that pregnant ·women only accounted for 31.3 percent. In regard to the use of protective clothes in case of the radiographers fixing films, the cases where no protective clothes were employed accounted for 88.1 percent. The reason was said to he attributable to the trouble related to wearing the clothes(54.2%). 6. The survey on the measurement of exposure dose shows that the cases where no measurement was made accounted for 76.1 percent. As far as the measurement methods of exposure dose was concerned, the employment of film badge accounted for 68.8 percent. The subjects turned out to conduct measurement of exposure dose every third month, which accounted for 43.8 percent. The barriers to the measurement of measurement of exposure dose were attributable to the recognition that a little amount of exposure dose need not be measured(29.9%). 7. The survey on the distinction of radiation rooms and clinic rooms reveals that the cases where radiation rooms exclusively existed accounted for 67.2 percent. 43.3 percent of the subjects turned out to have only one protective garment, and 49.3 percent of the subjects proved to conduct a periodical checkup of radiational equipment. The survey on the examination certificates of radiational generators and protective facilities indicates that 80.6 percent of the subjects had the certificates. The research also shows that the subjects with the marks indicating the radiational areas accounted for 70.1 percent. And trustees turned out to handle developing solutions and fixing solutions.

  • PDF

Free Radical Scavenging Effect and Oxidative Stress Protective Activity of Domestic Processed Polygoni Multiflori Radix (국내산 법제 하수오의 라디칼 소거능 및 산화적 스트레스 개선 효과)

  • Kim, Hyun Young;Kim, Jun Young;Cho, Eun Ju;Choi, Ji Myung;Hwang, Chung Eun;Lee, Hee Yul;Ahn, Min Ju;Lee, Jin Hwan;Kim, Yun-Geun;Ko, Keon Hee;Goo, Young-Min;Oh, Kyeong Yeol;Cho, Kye Man
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.6
    • /
    • pp.809-815
    • /
    • 2015
  • In this study, we confirmed biological compounds from methanol (MeOH) extract of processed Polygoni Multiflori Radix (PPMR), and the radical scavenging effect and oxidative stress protective activity of MeOH extract of PPMR were investigated under in vitro conditions using LLC-$PK_1$ renal epithelial cells. In HPLC analysis, MeOH extract of PPMR contained four species of biological compounds named 2,3,5,4'-tetrahydroxystilbene 2-O-${\beta}$-D-glucoside, emodin, chrysophanol, and rhein. 2,3,5,4'-Tetrahydroxystilbene 2-O-${\beta}$-D-glucoside was detected as the main compound in PPMR as 115.02 mg/kg. MeOH extract of PPMR showed 2,2-diphenyl-1-picrylhydrazyl (DPPH), 2,2'-azino-bis (3-ethylbenzthiazoline-6-sulphonic acid) diammonium salt (ABTS), and hydroxyl radical scavenging activities in a concentration- dependent manner. In particular, upon $50{\mu}g/mL$ of PPMR extract treatment, DPPH, ABTS, and hydroxyl radical scavenging activities were approximately 48.4%, 57.9%, and 81.2%, respectively. LLC-$PK_1$ cell viability declined in response to oxidative stress induced by pyrogallol, sodium nitroprusside (SNP), and morpholinosydnonimine (SIN-1) generators of NO, $O_2{^-}$, and $ONOO^-$, respectively. However, MeOH extract of PPMR significantly and dose-dependently inhibited oxidative-stressed LLC-$PK_1$ cell cytotoxicity. In fact, upon $50{\mu}g/mL$ of PPMR extract treatment, LLC-$PK_1$ cell viabilities were approximately 82.1%, 89.1%, and 77.6% compared to stress levels induced by pyrogallol, SNP, and SIN-1, respectively.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 - (공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 -)

  • Chung Kwang-Seop;Kim Min Soo;Kim Yongchan;Park Kyoung Kuhn;Park Byung-Yoon;Cho Keumnam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.

Design and Implementation of Transmission Scheduler for Terrestrial UHD Contents (지상파 UHD 콘텐츠 전송 스케줄러 설계 및 구현)

  • Paik, Jong-Ho;Seo, Minjae;Yu, Kyung-A
    • Journal of Broadcast Engineering
    • /
    • v.24 no.1
    • /
    • pp.118-131
    • /
    • 2019
  • In order to provide 8K UHD contents of terrestrial broadcasting with a large capacity, the terrestrial broadcasting system has various problems such as limited bandwidth and so on. To solve these problems, UHD contents transmission technology has been actively studied, and an 8K UHD broadcasting system using terrestrial broadcasting network and communication network has been proposed. The proposed technique is to solve the limited bandwidth problem of terrestrial broadcasting network by segmenting 8K UHD contents and transmitting them to heterogeneous networks through hierarchical separation. Through the terrestrial broadcasting network, the base layer corresponding to FHD and the additional enhancement layer data for 4K UHD are transmitted, and the additional enhancement layer data corresponding to 8K UHD is transmitted through the communication network. When 8K UHD contents are provided in such a way, user can receive up to 4K UHD broadcasting by terrestrial channels, and also can receive up to 8K UHD additional communication networks. However, in order to transmit the 4K UHD contents within the allocated bit rate of the domestic terrestrial UHD broadcasting, the compression rate is increased, so a certain level of image deterioration occurs inevitably. Due to the nature of UHD contents, video quality should be considered as a top priority over other factors, so that video quality should be guaranteed even within a limited bit rate. This requires packet scheduling of content generators in the broadcasting system. Since the multiplexer sends out the packets received from the content generator in order, it is very important to make the transmission time and the transmission rate of the process from the content generator to the multiplexer constant and accurate. Therefore, we propose a variable transmission scheduler between the content generator and the multiplexer to guarantee the image quality of a certain level of UHD contents in this paper.