• Title/Summary/Keyword: Generator stator windings

Search Result 106, Processing Time 0.797 seconds

Computations of Losses and Temperatures in the Core Ends of a High Voltage Turbo-generator

  • Liu Yujing;Hjarne Stig
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.299-305
    • /
    • 2005
  • The work described in this paper is to investigate the additional iron losses and consequent temperatures in core ends of a turbo-generator wound with high voltage cables. Electromagnetic calculations are made with 3D FE models, which include the lamination material with anisotropic properties both in magnetic permeability and electric conductivity. The models also include the geometry of the stator teeth and eventually the axial steps designated to reduce the core end losses. The 3D model of the rotor consists of field windings with straight in-slot parts and end windings. The thermal models are simplified into two dimensions and include the heat sources dumped from the 3D electromagnetic solutions. The influences of power factor on additional iron losses are studied for this cable wound machine and conventional machines. The calculation results show that the additional iron losses can be reduced to about $15\%$ by introducing some small steps around the airgap corner of core ends.

Electrical characteristics of class-F groundwall insulation tapes for stator windings (고정자 권선용 F종 주절연 테이프의 전기적 특성)

  • Kim, Tae-Hee;Kang, Myung-Guk;Lee, Jai-Kwun;Son, Sam-Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1679-1681
    • /
    • 2004
  • Class-F and B resin-rich type insulating tapes are generally used for the ground wall insulations of respective air-cooled and water-cooled stator windings in larger turbine generators. In this paper, their electrical properties coupled with aging times in higher temperature than designed one in normal condition were experimentally investigated and the results of two comparative tests were presented on the existing class-F resin-rich type tape and a developed one after curing. The resin-rich tapes currently used arc composed of six and a half 3-layer sheets that arc structured with mica paper, the top and bottom supports of it respectively, and the epoxy resin to bind them tightly. The results for breakdown voltage and strength on the cured specimens were presented, which were composed of the unaged, the aged accelerated for one, two, and three thousand hours at 180 $^{\circ}C$. The surface and volume resistivities on them were measured and the results are also presented to make a comparative test for the initial electrical characteristics.

  • PDF

Mechanical characteristics of class-F groundwall insulation tapes for stator windings (고정자 권선용 F종 주절연테이프의 기계적 특성)

  • Kim, Tae-Hee;Kang, Myung-Guk;Lee, Jai-Kwun;Son, Sam-Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1676-1678
    • /
    • 2004
  • Class-F resin-rich type insulating tapes are generally used for the groundwall insulations of the large turbine generators with air-cooled and hydrogen-cooled stator windings. In this paper, mechanical strength properties degraded over aging time in higher temperature than designed one in normal condition were experimentally investigated and the results of comparative tests were presented on the existing class-F resin-rich type tape and a developed one after curing. The resin-rich insulating tapes with composite material of Mica/Epoxy/support currently were used in this test. The tests for tensile and flexural strength properties were conducted with the specimens which were composed of unaged and the aged specimens accelerated for one, two, and three thousand hours at 180 $^{\circ}C$. The tensional strength was only measured for the unaged specimens and the results are also presented to make a comparative test for their initial mechanical characteristics.

  • PDF

Insulation Properties of Unaged Stator Winding Bars for Turbine Generators (터빈 발전기용 비열화 고정자 권선 바의 절연 특성)

  • Kim, Tae-Hee;Kang, Myung-Guk;Lee, Jai-Kwun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2097-2099
    • /
    • 2005
  • Class-F and class-B insulating materials based on the resin rich type mica-epoxy composites for the stator windings in large turbine generators have been developed by DHIC. In recent, stator winding bars applied with prototype insulation tapes and commercially available resin rich groundwall tapes were produced through the same manufacturing processes as the real bars. Comparative tests to obtain the insulation properties of both bars were carried out such as IR/PI. dissipation factor and partial discharge at room temperature. In this paper, the manufacturing processes and the insulation properties of the bars which were not aged are presented.

  • PDF

Study of Shorted-turn for Cylindrical Synchronous Generator Rotor (원통형 동기발전기 회전자의 층간단락에 관한 연구)

  • Kim, Young-Jun;Kim, Jang-Mok;Lee, Sang-Hyuk;Ahn, Jin-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.2 s.74
    • /
    • pp.52-56
    • /
    • 2006
  • This paper describes the methods for the detection of shorted-turn in the rotor of a cylindrical synchronous generator. A search coil is installed in the air-gap to detect the shorted-turn. The occurrence of a fault in the rotor winding results in a decrease of the induced voltages in the stator. And the magnitude of the rotor flux can be estimated by using the search coil and the estimated stator voltages respectively. And the magnitude of the estimated rotor flux is used for discriminating the rotor windings short or not by detecting the magnitude of the rotor flux. The method using a search coil located in the air-gap can detect not only the occurrence of a turn fault but also its position in the rotor winding. But the method using the estimated stator voltages gives the magnitude of the rotor flux, and only the number of a short-turn.

Analysis of Parameters on Partial Discharges from Insulation Defects of used Hydro Generator Stator Windings (수력발전기 고정자 노후권선의 모의결함 시편에 대한 부분방전 파라미터 변화 분석)

  • Oh, Bong-Keun;Kim, Hyun-Il;Kang, Seong-Hwa;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.7
    • /
    • pp.645-649
    • /
    • 2007
  • Partial discharge(PD) test for simulated insulation defects of used hydro generator stator winding was conducted to analyze the PD Parameters. Simulated insulation defects are classified by 5 types corona, slot, internal, multi and aging defect. Phase resolved partial discharge, statistical parameter (skewness, kurtosis), PD magnitude as a function of the test voltage(Q-V curve) and PD magnitude change under test voltage for 2 minutes are used as PD parameters. The analysis of PD parameters by 4 types are proved to be useful methods. In particular, PD parameter characteristics of aging defect could help to assess the aging condition of stator winding because aging defect has more weak insulation strength than other insulation defects : PD distribution is wide and flat, PD rises rapidly near $0^{\circ}\;and\;180^{\circ}$ and Q-V curve rises sharply and then gently drops.

A Study of The Deterioration Characteristics due to Heat Cycle of Generator Stator Windings (발전기 고정자권선의 히트사이클에 의한 열화특성에 관한 연구)

  • Kim, H.G.;Kim, T.S.;Park, M.S.;Park, C.H.;Song, U.C.;Park, Y.G.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.379-381
    • /
    • 1995
  • Many generating stations in korea are 25 years or more old, and are nearing the end of their planned life. Financial conditions and Site, Environment problems have made approval for construction of new stations increasingly difficult, and extending the life of an existing older plant may be a palatable alternative. Therefore, To determine whether generator rewinds are necessary to achieve an extended life, and Methods are required to estimate the proable remaining life of existing winding, here, We are going to estimate insolation condition through Nondestructive diagonostic test and Aging history tests of generator Stator winding and winding conditions through deterioration characteristics due to Heat cycle.

  • PDF

Feature Extraction for Fault Signals of High Voltage Motor Stator Windings (고압전동기 결함신호의 특징추출에 관한 연구)

  • Park, Jae-Jun;Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1154-1157
    • /
    • 2004
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in imitation stator winding of high voltage motors. The motor was energized to 4.47kV, 6.67, respectively. Applied voltage to Imitation winding was used two voltage level, 4.47[KV]and 6.67[KV]. Motors having imitation stator winding were installed with 80pF capacitive couplers at the terminal box Case of PD Pattern regarding applied voltage phase angel, the PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). As the result, we could discrimidate using TGA the difference of internal and surface discharge for imitation stator winding. We have used the other technique, in order to feature extraction of faulty signals on stator winding, Daubechies Discrete wavelet transform and Harmonics analysis(FFT) about faulty signals.

  • PDF

Assessment of Insulation Condition in Large Turbine Generator Stator Windings (대용량 터빈발전기 고정자 권선의 절연상태 평가)

  • Kim, Hee-Dong;Lee, Young-Jun;Park, Deok-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2093-2096
    • /
    • 1999
  • This paper describes to access the insulation deterioration condition of the stator windings in three large turbine generators. Nondestructive tests have been carried out on stand-still generators which have been in service for 2 to 30 years. In most cases these tests include ac current increase rate($\Delta$I), delta tan delta( ${\Delta}tan{\delta}$), and maximum partial discharge(Qm). Gen. 2 show that the $tan{\delta}$ is higher than other two generators in the $tan{\delta}$-voltage curve. Partial discharge(PD) patterns were observed internal, corona and treeing discharges in large turbine generators. The PD tests were confirmed the correlation between discharge patterns and the kinds of defects.

  • PDF