The field-test for single line-to-ground fault by an artificial fault generator (인공고장 발생장치(AFG)를 이용한 지락고장 실증시험)

  • Choi, Sun-Kyu;Kim, Dong-Myung;Kang, Moon-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.97-100
    • /
    • 2004
  • This paper introduced an artificial fault generator which was operated in the Go-Chang field-test center and explained the result of single line-to-ground fault by AFG. The AFG can basically experiment line-to-line and line-to-ground faults. This facility directly connected distribution transmission lines, so the test results are very useful for power system analysis and protection. Using the function of the AFG, we briefly said the test methods ud results for the 22.9[kV-v] and $6.6[kV-{\Delta}]$ system.

  • PDF

An Analysis and Comparison of Steam Turbine Overspeed Protectors (증기터빈 과속도 보호장치의 비교분석)

  • Choi, In-Kyu;Jeong, Chang-Ki;Kim, Jong-An
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2260-2262
    • /
    • 2004
  • After steam turbines in power plant drives generator and maintains it at rated speed using high temperature and high pressure steam energy, they regulate the output of generator when synchronized in parallel with the power system. By the way, as the steam flow into turbine can not be reduced fast even though the electrical load is lost, the turbine gets into dangerous situation due to the increase of its speed. At this time, the duty of the turbine governor is "how to limit the speed within its overspeed trip setpoint and escape from danger." For the purpose of it, there are various ways known. Some overspeed protection methods for steam turbines now being operating in korea are introduced in this paper.

  • PDF

Prevention of Oil Contamination in the Excitation System of a Power Plant Generator (발전용 발전기 여자설비의 오일 오염방지)

  • Choi, Jae-Gyu;Yoo, Ho-Seon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.7 no.2
    • /
    • pp.30-38
    • /
    • 2011
  • The purpose of this paper is to review the understanding of pollution causes in the excitation system and how to solve the problem. The cause of the problem was in-leakage of bearing lubricant oil through the gap between rotor and outer in the air deflector, which was triggered by a negative pressure with respect to the operation of a collector ring fan in the collector house. In order to prevent exciting current transmission equipment pollutant, the reduction of the negative gage pressure of the inside of collector house is required. The protection in-leakage of bearing lubricant oil through the gap between rotor and outer of the air deflector are necessary. The reduction of the inside diameter of air deflector and the expansion of inlet filter of collector house are inevitable.

  • PDF

A Study on Overspeed Control and Valve Position Control for Steam Turbine in Power Plants (증기터빈 밸브제어방식에 따른 과속도 제어 고찰)

  • Choi, In-Kyu;Woo, Joo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1661-1662
    • /
    • 2008
  • After steam turbines in power plant drives generator and maintains it at rated speed using high temperature and high pressure steam energy, they regulate the output of generator when synchronized in parallel with the power system. By the way, as the steam flow into turbine can not be reduced fast even though the electrical load is lost, the turbine gets into dangerous situation due to the increase of its speed. At this time, the duty of the turbine governor is "how to limit the speed within its overspeed trip setpoint and escape from danger." In order to implement this purpose, there are various ways different from valve position control. So, in this paper, the various methods for overspeed protection are introduced in comparison with valve position control.

  • PDF

Application of IMCS MBC Logic for Thermal Power Plant (발전소 통합감시제어시스템의 MBC 개발 로직 실계통 적용)

  • Shin, Man-Su;Yoo, Kwang-Myeng;Byun, Seung-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.845-851
    • /
    • 2013
  • Because the existing control system has been operating for about 20 years, it is necessary to upgrade the system for stable and efficient operation. But, there is a difficulty in maintenance by difference of manufacturer of each main control systems for boiler, turbine and generator. This developed IMCS(Integrated Monitoring and Control System) consists of more than 10,000 inputs and outputs for large scale thermal power plant. This paper consists of the development journey of IMCS MBC(mill and burner control) ; core binary protection & monitoring logic including prevention circuit of boiler explosion & implosion. In this project, the IMCS for boiler, turbine and generator was developed on basis of one communications platform. In this paper, the whole journey of development of IMCS MBC is dealt with designing software and hardware, coding application software, and validating software and hardware.

Analysis of the System Impact of Distributed Generation using EMTP

  • Yeo, Sang-Min;Kim, Il-Dong;Kim, Chul-Hwan;Aggarwal, Raj
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.4
    • /
    • pp.201-206
    • /
    • 2004
  • With the advent of distributed generation, power systems in general are impacted in regards to stability and power quality. Distributed generation has positive impacts on system restoration following a fault, higher reliability, and mitigation of effect due to voltage sag. However, distributed generation also has negative impacts on the decrease of reliability such as changes of protective device setting and mal-operation. Because bulk power systems consist of various sources and loads, it is complicated to analyze power systems that have distributed generation. The types of distributed generation usually are classified as the rotating machinery system and the inverter-based system. In this paper, distributed generation is designed as a synchronous generator, and the distribution system with its distributed generation model is simulated using EMTP. In addition, this paper shows the simulation results according to the types of distributed generation

Estimation of the Generating Power for Distributed Generations Interconnected with Distribution Networks (배전 계통에 연계된 분산전원의 발전량 예측 알고리즘)

  • Choi, Don-Man;Jang, Sung-Il;Kim, Kwang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.327-330
    • /
    • 2003
  • This paper proposes an estimation algorithm for the generating power of distributed generations(DG) interconnected with distribution networks. These days, DG are rapidly increasing and most of them are interconnected with distribution networks. The DG can supply power into the distribution network, which may make significant impact on fault current and the protection scheme of the interconnected distribution networks. Generally these influences of DG is proportioned as the distributed generator's power. Therefore, it is important to forecast the output power of distributed generator in PCC(point of common coupling). This paper presents the prediction method of DG's power by monitoring the current and phase difference.

  • PDF

Solid State Pulsed Power Modulator and Its Application (반도체 스위치기반 펄스전원 기술 개발 및 응용)

  • Ryoo, Hong-Je;Jang, Sung-Roc
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.193-194
    • /
    • 2015
  • In this paper, the solid state pulsed power modulator developed in KERI, which is based on IGBT technologies are overviewed. During last ten years, several kinds of solid state modulators were developed in KERI such as IGBT stacks with step up transformer, full IGBT stack based marx generator, modified IGBT marx generator and high repetitive solid state modulator. Basic principle of the design is described and each pros and cons are compared. KERI's solid state pulsed power modulators has lot of advantages for industrial pulsed power application focused on everlasting life cycle and high repetitive, and shows superior arching protection ability.

  • PDF

The study of the complete protection for ground-fault of the generator stator winding based on the sihwa tidal power plant's hydraulic turbine generator (시화호조력발전소 수차발전기를 모델로 한 발전기 고정자권선 지락사고에 대한 100%보호방안 고찰)

  • Kang, Dong-Hyung;Park, Sung-Ho;Kim, Jong-Deug;Nam, Jin-Geuk;Choi, Hyeong-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.184-186
    • /
    • 2007
  • 절연물의 열화가 진행되면 최초로 1선 지락사고가 발생할 가능성이 많고 1선 지락사고는 2선 지락 및 단락사고로 파급되어 설비에 심각한 손상으로 이어지게 된다. 따라서, 1선지 락 사고에 대한 완전한 보호방식의 적용은 설비 신뢰성 증대라는 측면에서 매우 중요한 사항이라고 판단된다. 이에 시화호조력 발전소에 설치될 수차발전기는 고정자권선의 지락사고에 대한 100%보호방식을 적용하였으며 이 설계사례를 토대로 실제적으로 적용가능한 발전기 고정자권선의 지락보호증대방식을 공유코자 한다.

  • PDF

Investigation of Response of Several Neutron Surveymeters by a DT Neutron Generator (DT 중성자 발생기에 의한 중성자 검출기 반응도 조사)

  • Kim, Sang-In;Jang, In-Su;Kim, Jang-Lyul;Lee, Jung-Il;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.35-40
    • /
    • 2012
  • Several neutron measuring devices were tested under the neutron fields characterized with two distinct kinds of thermal and fast neutron spectrum. These neutron fields were constructed by the mixing of both thermal neutron fields and fast neutron fields. The thermal neutron field was constructed using by a graphite pile with eight AmBe neutron sources. The fast neutron field of 14 MeV was made by a DT neutron generator. In order to change the fraction of fast neutron fluence rate in each neutron fields, a neutron generator was placed in the thermal neutron field at 50 cm and 150 cm from the reference position. The polyethylene neutron collimator was used to make moderated 14 MeV neutron field. These neutron spectra were measured by using a Bonner sphere system with an LiI scintillator, and dosimetric quantities delivered to neutron surveymeters were determined from these measurement results.