• Title/Summary/Keyword: Generator output

Search Result 1,049, Processing Time 0.029 seconds

Output Voltage Control Method of Switched Reluctance Generator using PID Control (PID 제어를 이용한 Switched Reluctance Generator의 출력 전압제어)

  • 김영조
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.701-704
    • /
    • 2000
  • A SRG(Switched Reluctance Generator) has many advantages such as efficiency simple controllability low cost and robustness compared with outer machines. But the theories that have been adopted as SRG control methods up to the present are complicated. This paper proposes a simple control methods using PID which controls only a turn-off angle while making turn-on angle signals of SRG constant. controlling the voltage differences between the reference and the real value and calculating the proper turn-off angle of the load variations can implement to keep the output voltage constant. the control method suggested in this paper enhances the efficiency of this system and simplifies the hardware and software by using only the voltage and speed sensors. The proposed method is verified by experiment

  • PDF

Output Voltage Control Method of a Switched Reluctance Generator using Turn-off Angle Control (소호각 제어를 이용한 Switched Reluctance Generator의 출력 전압 제어)

  • 김영조;전형우;김영석
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.7
    • /
    • pp.356-363
    • /
    • 2001
  • A SRG (Switched Reluctance Generator) has many advantages such as high efficiency, low cost, high-speed capability and robustness compared with other of machine. But the control methods that have been adopted for SRGs are complicated. This paper proposes a simple control method using the PID controller which only controls turn-off angles while keeping turn-on angles of SRG constant. In order to keep the output voltage constant, the turn-off angle for load variations is controlled by using linearity between the generated current and turn-off angle since the reference generated current can be led through the voltage errors between the reference and the actual voltage. The suggested control method enhances the robustness of this system and simplifies the hardware and software by using only the voltage and the speed sensors. The proposed method is verified by experiments.

  • PDF

Characterization and Performance Evaluation of Advanced Aircraft Electric Power Systems

  • Eid, Ahmad;El-Kishky, Hassan;Abdel-Salam, Mazen;El-Mohandes, Mohamed T.
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.563-571
    • /
    • 2010
  • A model of an advanced aircraft electric power system is developed and studied under variable-speed constant-frequency (VSCF) operation. The frequency of the generator's output voltage is varied from 400-Hz to 800-Hz for different loading scenarios. Power conversions are obtained using 12-pulse power converters. To reduce the harmonic contents of the generator output waveforms, two high-pass passive filters are designed and installed one at a time at the generator terminals. The performance of the two passive filters is compared according to their losses and effectiveness. The power quality characteristics of the studied VSCF aircraft electric power system are presented and the effectiveness of the proposed filter is demonstrated through compliance with the newly published aircraft electrical standards MIL-STD-704F.

Speed Estimation of Diesel-Generator Systems Based on Multiple SOGI-FLLs (다중 SOGI-FLL 기반 엔진-발전기 시스템의 속도 추정)

  • Dao, Ngoc Dat;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.63-64
    • /
    • 2017
  • This paper proposes a speed estimator for sensorless control of diesel-generator (genset) systems, where the speed of the genset is calculated from the back-EMF frequency of the generator. The back-EMF frequency is extracted from a phase output current by using multiple second-order generalized integrators (SOGIs) connected in parallel and series and separated frequency-locked loops. The proposed method (PS-SOGI-FLL) is able to estimate the fundamental frequency in the distorted output current with high accuracy and strong robustness. Simulation results are shown to verify the validity of the proposed method.

  • PDF

An Operating Characteristics of Surface Permanent Magnetic Synchronous Generator for 5-Phase 5kW (5상 5kW 표면부착형 영구자석 동기발전기 운전특성)

  • Jung, Hyung-Woo;Kim, Min-Huei;Song, Hyun-Jik;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.9-16
    • /
    • 2013
  • This paper presents an operating characteristics of the 5-phase 5kW with developed the surface permanent magnetic synchronous generato (SPMSG) in order to make a study of a polyphase ac motors keeping hold of more advantages. There are shown a amplitude and waveform of the generated electromotive force, in FFT analysis of harmonics, within output voltages, and reviewing a experiment results in no-load test, resistive load, and inductive load using 5-phase induction motor by variable output frequency. The operating characteristics of the developed manufacturing generator include voltage regulation, efficiency, power factor, THD, and so on at rated load.

The Output Power Control in the Sea-Wave Input Generation System by the Secondary Excited System (이차여자시스템에 의한 파력발전시스템의 출력제어)

  • 김문환
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.5
    • /
    • pp.1013-1018
    • /
    • 2003
  • This paper deals with the secondary excited induction generator applied to random energy input generation system. As it is preferred to stabilize the output voltage and frequency in the constant level, microcomputer controlled inverter connected to the secondary windings supplies the secondary current with slip frequency. For testing the appropriateness of this paper, the input torque simulator, which generate the statistically varied wave power input torque in the laboratory to drive the secondary excited induction generator, are constructed. The experimental and numerical results show the advantage of secondary excited induction generator system for the random input wave generation system.

Comparison of Ripple of High Voltage X-ray Generator by Rectification type (X선 고전압 장치의 정류형태에 따른 리플 비교)

  • Kim, Young-Pyo;Kim, Tae-Gon;Cheon, Min-Woo;Lee, Ho-Shik;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.128-128
    • /
    • 2010
  • The high-voltage X-ray generator recently used is very popular, because that can be miniaturized, increased in generating efficiency, elaborated in output control. All these features are available with high-frequency made by using an inverter, the fast switching semiconductor device. In this paper to identify the differences among types of rectification, we compared output ripple with full-wave rectification and dual-voltage rectification methods.

  • PDF

Motor speed and revolution angle detection using a sinusoidal AC tacho-generator (정현파 교류 타코제너레이터를 이용한 전동기 속도 및 회전각 검출)

  • 최정수;유완식;조규민
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.6
    • /
    • pp.94-103
    • /
    • 1997
  • This paper presents motor speed and revolution angle detection method using a sinusoidal AC tacho-generator. The 2-phase or 3-phase output tacho-generator can be adopted, and its' output voltages must have sinusoidal waveforms. Because the detection algorithm is simple, the proosed method can be implemented with analog devices or microprocessor conveniently. And the proposed method has a very short detection delay time. Especially in the analog implementation, there is no delay time without the settling time of analog devices. With the experimental results, it is verified that the proposed method can acculately detect the instantaneous motor speed and revolution angle over the wide ranges.

  • PDF

Buck-Boost DC to DC Converter for Thermoelectric Generator with Constant Output Voltage (열전 모듈의 정전압 출력 시스템을 위한 벅-부스트 DC-DC 변환기)

  • Cho, Sung-Kyu;Park, Soon-Seo;Kim, Ji-Gon;Nam, Ki-Hun;Kim, Shi-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1845-1849
    • /
    • 2010
  • We have proposed and fabricated a Buck-Boost DC to DC Converter for Thermoelectric generator (TEG) with constant output voltage suitable for battery chargers or constant voltage supplies in the range of several watt. The experimental and simulation results have shown that the proposed method allows stable operation with maximum 86% power transfer efficiency. The proposed circuit has a merit in cost and miniaturization of a system compared to conventional MPPT algorithms, because the proposed method adopts only analog circuit without DSP or micro controller unit for calculating peak power point by iterative methods.

Study for the Design and Measurement of the High Voltage Pulse Generator Using Transformers (트랜스포머를 이용한 고전압 펄스 발생 장치의 설계와 측정평가에 관한 연구)

  • Kim, Young-Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.82-86
    • /
    • 2012
  • High-capacity high-voltage pulse generator that can be used for environmental clean-up was developed using transformers. High-voltage pulse is consists of the primary wave and the harmonic wave which are increased as a series circuit using transformers to make pulses. Each transformer has a band-pass characteristics. The output voltage of the pulse width 50[%] was decided. The output voltage of high-voltage pulse generator device was measured as 1.4[kV] (Peak-to-Peak).