• Title/Summary/Keyword: Generator mode

Search Result 482, Processing Time 0.023 seconds

바이오 가스 이륜차 기관의 성능 특성 연구 (An Investigation of Performance Characteristics of A Biogas-Fueled Motorcycle Engine)

  • 현탄 콩;치엠트란 람;부티김 차우
    • 한국수소및신에너지학회논문집
    • /
    • 제23권4호
    • /
    • pp.373-381
    • /
    • 2012
  • To determine the performance characteristics of motorcycle engine using biogas for practical use, the intake system of a 110 cc motorcycle engine is properly modified to operate with biogas as a fuel. Biogas is a potentially renewable fuel for replacing gasoline in future, but it has high percentage of $CO_2$ that could lead to slow the burning rate of biogas-air mixture and cause instability in combustion. Thus, the performance characteristics of biogas-fueled motorcycle engines could be different from those of gasoline motorcycle engines. In this paper, the important parameters of performance characteristics (such as: power output, thermal efficiency, fuel consumption, exhaust emission,${\cdots}$) of biogas-fueled motorcycle engine are studied and estimated with change of engine speed and load. The obtained results when operating with biogas are used to compare with that of gasoline fuel under the same operating conditions. Engine speed in the experimental is changed from 1500 rpm (idle-mode) up to 3500 rpm by a step of 500 rpm. Engine load is changed from zero to maximum load with the help of an exciting voltage device from generator-type dynamometer. The experimental results show that the tested engine operated with richer biogas-air mixture than that of gasoline-air mixture under the same test conditions. Biogas-fueled engine gives a higher fuel consumption and lower thermal efficiency under the same power output. Brake thermal efficiency of biogas engine is found to be about 3% lower than gasoline-fueled motorcycle engine for whole range of speed. Exhaust emission of biogas-fueled motorcycle engine (such as: CO, HC) is found to be lower than the limitation level of the emission standards of Vietnam for motorcycle engines (CO <4.5% HC <1200 ppm).

추력 제어를 고려한 액체로켓 엔진시스템 과도해석 (Transient Analysis of a Liquid Rocket Engine System Considering Thrust Control)

  • 박순영;최환석;설우석
    • 한국추진공학회지
    • /
    • 제8권4호
    • /
    • pp.67-75
    • /
    • 2004
  • 액체로켓 엔진시스템에 있어서 과도 해석은 시스템 시험 항목이나 시험 횟수의 선정과 개발 기간 등의 단축을 위해 반드시 필요한 항목이다. 본 연구에서는 터보펌프 공급식 로켓 엔진의 수학적 모델을 구성하였으며. 이를 이용하여 추력 제어 밸브의 개도 변화에 따른 엔진의 작동 모드 변화에 대한 과도해석을 수행하였다. 검증을 위하여 AnaSyn을 이용한 모드 해석 결과와 비교하여 2% 범위 내로 일치하는 것을 확인하였다. 또한 로켓 엔진 시스템의 과도해석 모델을 이용하여 엔진 구성품에 대한 시스템 차원의 설계 변수 결정이 가능함을 보였다. 압력안정기(pressure stabilizer)는 가스발생기 혼합비를 균일하게 유지시켜주는 장치로서, 이에 대한 감쇠 강제진동 모델을 세워 고유진동수와 감쇠비의 함수로 안정 영역을 구하였다.

Hard PZT IDE 유니몰프 캔틸레버의 압전 에너지 하베스팅 특성 (Piezoelectric Energy Harvesting Characteristics of Hard PZT Interdigitated Electrode (IDE) Unimorph Cantilever)

  • 이민선;김창일;윤지선;박운익;홍연우;조정호;백종후;박용호;장용호;최범진;정영훈
    • 한국전기전자재료학회논문지
    • /
    • 제30권8호
    • /
    • pp.501-507
    • /
    • 2017
  • A unimorph piezoelectric cantilever generator with an interdigitated electrode (IDE) was developed for vibration energy harvester applications driven in the longitudinal mode. Hard lead zirconate titanate (PZT) ceramic with a high $Q_m$ of 1,280 was used as the piezoelectric active material. Ten PZT sheets produced by tape casting were laminated and co-fired with an Ag/Pd IDE at $1,050^{\circ}C$ for 2 h. The approximately $280{\mu}m$-thick co-fired PZT laminate with the IDE was attached to a stainless steel substrate with an adhesive epoxy for the fabrication of an IDE unimorph cantilever. Its energy harvesting characteristics were evaluated: an output power of $1.1{\mu}W$ at 120 Hz across the resistive load of $700k{\Omega}$ was obtained, corresponding to a normalized power factor of $4.1{\mu}W/(G^2{\cdot}cm^3)$.

Back to bock 컨버터를 갖는 가변속 풍력터빈 시스템의 모델링과 해석 (Modeling and Analysis of Variable Wind Speed Turbine System Using Back to Back Converter)

  • 김일환;강경보;김재홍;문상호;오성보;김세호
    • 조명전기설비학회논문지
    • /
    • 제19권8호
    • /
    • pp.150-157
    • /
    • 2005
  • 본 논문에서는 이중여자 유도발전기의 회전자에 back to back 컨버터가 채용된 가변속 풍력터빈 시스템의 모델링과 해석을 나타내었다. 제어시스템의 특성을 파악하기 위해서 시뮬레이션에서는 Psim 프로그램을 사용하여 660[kW] 의 출력정격을 갖는 시스템을 모델로 하였다. 모델링에서는 블레이드 제어 시스템 모델과 회전자와 계통선에 연결된 컨버터 시스템을 모델링 하였다. 풍속의 변화에 따라 원하는 출력을 얻을 수 있도록 피치각을 제어하여 정격풍속 이하에서도 최대출력이 발생하도록 하였고, 정격풍속 이상에서는 회전자 속도를 일정하게 하여 정격출력을 유지할 수 있도록 하였다. 또한 무효전력을 제어하여 출력의 역률을 제어하였다. 제안한 해석방법의 타당성을 검증하기 위하여 풍속변화에 따른 모델 시스템의 시뮬레이션 결과 값들과 제주행원 풍력발전 단지에서 운용되고 있는 V47 660[kW] 시스템의 실측 결과들과 서로 비교 검증하여 제안한 해석 방법의 타당성을 입증하였다.

최대 전압 강하에 비례하는 무효전류 공급 루프를 이용한 DFIG 풍력단지의 계층전압제어 (Hierarchical Voltage Regulation of a DFIG-based Wind Power Plant Using a Reactive Current Injection Loop with the Maximum Voltage Dip for a Grid Fault)

  • 박건;김진호;강용철
    • 전기학회논문지
    • /
    • 제65권8호
    • /
    • pp.1334-1339
    • /
    • 2016
  • In a power grid that has a high wind power penetration, the fast voltage support of a wind power plant (WPP) during the grid fault is required to stabilize the grid voltage. This paper proposes a voltage control scheme of a doubly-fed induction generator (DFIG)-based WPP that can promptly support the voltage of the point of common coupling (PCC) of a WPP during the grid fault. In the proposed scheme, the WPP and DFIG controllers operate in a voltage control mode. The DFIG controller employs two control loops: a maximum voltage dip-dependent reactive current injection loop and a reactive power to voltage loop. The former injects the reactive power in proportion to the maximum voltage dip; the latter injects the reactive power in proportion to the available reactive power capability of a DFIG. The former improves the performance of the conventional voltage control scheme, which uses the latter only, by increasing the reactive power as a function of the maximum voltage dip. The performance of the proposed scheme was investigated for a 100-MW WPP consisting of 20 units of a 5-MW DFIG under various grid fault scenarios using an EMTP-RV simulator. The simulation results indicate that the proposed scheme promptly supports the PCC voltage during the fault under various fault conditions by increasing the reactive current with the maximum voltage dip.

Mercuric iodide 기반의 디지털 X-선 검출기의 특성 연구 (Characterization studies of digital x-ray detector based on mercuric iodide)

  • 조성호;박지군;최장용;석대우;차병열;남상회;이범종
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.392-395
    • /
    • 2003
  • For the purpose of digital x-ray imaging, many materials such as $PbI_2$, $HgI_2$, TlBr, CdTe and CdZnTe have been under development for servaral years as direct converter layer. $Hgl_2$ film detector have recently been shown as one of the most promising semiconductor materials to be used as direct converters in x-ray digital radiography. This paper, the $HgI_2$ films are deposited on conductive-coated glass by screen printing, in which $HgI_2$ powder is embedded in a binder and solvent, and the slurry is used to coat the conductive-coated glass. We investigated electrical characteristic of the fabricated $HgI_2$ films. The x-ray response to radiological x-ray generator of 70Kvp using the current integration mode will be reported for screen printing films. These results indicate that $HgI_2$ detectors have high potential as new digital x-ray imaging devices for radiography.

  • PDF

Development of Large-Area RF Ion Source for Neutral Beam Injector in Fusion Devices

  • Chang, Doo-Hee;Jeong, Seung Ho;Kim, Tae-Seong;Park, Min;Lee, Kwang Won;In, Sang Ryul
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.179.2-179.2
    • /
    • 2013
  • A large-area RF-driven ion source is being developed at Germany for the heating and current drive of ITER device. Negative hydrogen ion sources are major components of neutral beam injection (NBI) systems in future large-scale fusion experiments such as ITER and DEMO. The RF sources for the production of positive hydrogen ions have been successfully developed at IPP (Max-Planck-Institute for Plasma Physics), Garching, for the ASDEX-U and W7-AS neutral beam heating systems. Ion sources of the first NBI system (NBI-1) for the KSTAR tokamak have been developed successfully with a bucket plasma generator based on the filament arc discharge, which have contributed to achieve a good plasma performance such as 15 sec H-mode operation with an injection of 3.5 MW NB power. There is a development plan of RF ion source at the KAERI to extract the positive ions, which can be used for the second NBI system (NBI-2) of the KSTAR and to extract the negative ions for future fusion devices such as Fusion Neutron Source and Korea-DEMO. The development progresses of RF ion source at the KAERI are described in this presentation.

  • PDF

Diamond-Like Carbon Films Deposited by Pulsed Magnetron Sputtering System with Rotating Cathode

  • Chun, Hui-Gon;You, Yong-Zoo;Nikolay S. Sochugov;Sergey V. Rabotkin
    • 한국표면공학회지
    • /
    • 제36권4호
    • /
    • pp.296-300
    • /
    • 2003
  • Extended cylindrical magnetron sputtering system with rotating 600-mm long and 90-mm diameter graphite cathode and pulsed power supply voltage generator were developed and fabricated. Time-dependent Langmuir probe characteristics as well as carbon films thickness were measured. It was shown that ratio of ions flux to carbon atoms flux for pulsed magnetron discharge mode was equal to $\Phi_{i}$ $\Phi$sub C/ = 0.2. It did not depend on the discharge current in the range of $I_{d}$ / = 10∼60 A since both the plasma density and the film deposition rate were found approximately proportional to the discharge current. In spite of this fact carbon film structure was found to be strongly dependent on the discharge current. Grain size increased from 100 nm at $I_{d}$ = 10∼20 A to 500 nm at $I_{d}$ = 40∼60 A. To deposit fine-grained hard nanocrystalline or amorphous carbon coating current regime with $I_{d}$ = 20 A was chosen. Pulsed negative bias voltage ($\tau$= 40 ${\mu}\textrm{s}$, $U_{b}$ = 0∼10 ㎸) synchronized with magnetron discharge pulses was applied to a substrate and voltage of $U_{b}$ = 3.4 ㎸ was shown to be optimum for a hard carbon film deposition. Lower voltages were not sufficient for amorphization of a growing graphite film, while higher voltages led to excessive ion bombardment and effects of recrystalization and graphitization.

지능형 OCR 시스템을 위한 한글 필기체 생성 및 분류 모델에 관한 연구 (A Study on Hangul Handwriting Generation and Classification Mode for Intelligent OCR System)

  • 백진성;서지윤;정상중;정도운
    • 융합신호처리학회논문지
    • /
    • 제23권4호
    • /
    • pp.222-227
    • /
    • 2022
  • 본 논문에서는 다양한 산업분야에 적용 가능한 딥러닝 알고리즘 기반의 한글 필기체 생성 및 분류 모델을 구현하였다. 구현된 GAN 기반의 한글 필기체 생성 모델과 CNN 기반의 한글 필기체 분류 모델 2가지로 구성되어 있다. GAN 모델은 가짜 한글 필기체 데이터를 생성하기 위한 생성자 모델과 가짜 필기체 데이터를 판별하기 위한 판별자 모델로 구성된다. CNN 모델의 경우 'PHD08' 데이터세트를 활용하여 모델의 학습을 수행하였으며, 학습 결과 92.45% 정확도로 한글 필기체를 분류하는 것을 확인하였다. 구현된 GAN 모델을 통해 생성된 한글 필기체 데이터를 기존 CNN 모델의 학습 데이터세트와 통합하여 분류 모델의 성능평가를 진행한 결과 96.86%로 기존 분류 성능보다 우수하게 나타남을 확인하였다.

만성폐쇄성 폐질환 환자에서 M-mode 초음파로 측정한 횡격막 운동 (M-mode Ultrasound Assessment of Diaphragmatic Excursions in Chronic Obstructive Pulmonary Disease : Relation to Pulmonary Function Test and Mouth Pressure)

  • 임성철;장일권;박형관;황준화;강유호;김영철;박경욱
    • Tuberculosis and Respiratory Diseases
    • /
    • 제45권4호
    • /
    • pp.736-745
    • /
    • 1998
  • 연구배경: 횡격막의 운동은 흉부 단순 촬영과 fluoroscopy로 관찰해 왔으나 근래 초음파에 의해서 횡격막의 운동거리와 두께를 측정하는 연구들이 있어왔다. 초음파 검사의 장점을 살펴보면 간편하고 비침습적이며 방사선조사가 없고 재현성과 정확성이 있다는 점을 들 수 있다. 본 연구에서는 이러한 횡격막 운동 측정에 대한 초음파의 장점을 이용하여 정상인과 만성폐쇄성 폐질환 환자에서 횡격막 운동을 조사하고 그 결과를 폐기능 지표들과 비교하였다. 연구방법: 정상 성인 28례(의과대학생 16례, 나이를 고려한 대조군 12례)와 만성폐쇄성 폐질환 환자 17례를 대상으로 각각에서 폐기능 검사, 최대 흡기압, 최대 호기압과 초음파상 횡격막의 이동 거리를 측정하여 비교하였다. 초음파는 Aloka 사의 KEC-620 모델을 이용하였으며 앙와위 상태에서 환자의 쇄골 중심선에 해당하는 부위의 우상복부에 횡으로 3.5MHz 탐촉자를 대고 간을 에코창으로 이용하여 M-mode 상에서 평상 호흡시와 폐활량 호흡 또는 최대 호흡시의 횡격막 이동 거리를 3회 측정하여 그 평균값을 얻었으며 최대 흡기압과 최대호기압은 Chest사의 Vitalopower KH-101을 이용하여 3회 측정하여 그 평균값을 얻었다. 결 과: 정상인에서의 횡격막 이동거리는 평상호흡에는 1.5cm-1.7cm를 보였고 최대호흡시에는 5.7cm-6.7cm를 보였다. 정상인에서의 최대호흡시에 횡격막 이동거리는 $FEV_1$ $FEV_1/FVC$, PEF, PIF, 신장과 유의한 상관관계를 보였으나 다중 희귀분석에서는 $FEV_1$ 만이 유용한 예측지표로 계산되었다. 만성폐쇄성 폐질환 환자에서의 횡격막 이용거리는 평상호흡시에는 $1.5{\pm}0.6cm$로 정상인과 유의한 차이가 없었으나 최대호흡시에는 $3.7{\pm}1.3cm$로 대조군에 비해 유의하게 감소되어 있었다. 만성폐쇄성 폐질환 환자군의 각 병기에 따라 횡격막 이동거리를 비교해 본 결과 최대호흡시 횡격막의 이동거리는 $FEV_1$이 감소할수록 짧은 경향을 보였으나 통계적 의의는 없었다. 만성폐쇄성 폐질환 환자에서의 최대호흡시에 횡격막 이동거리는 연령, PEmax, %FVC와 유의한 상관관계를 보였으나 다중 회귀분석에서는 최대호기압(PEmax)과 연령이 유의한 예측인자로 계산되었다. 결 론: 만성폐쇄성 폐질환 환자의 횡격막 이동거리는 정상인에 비해 유의하게 감소하였으며 최대호기압과 가장 좋은 상관관계를 보였다. 그러나 만성폐쇄성 폐질환 환자에서 횡격막 이동거리는 $FEV_1$과 유의한 상관관계를 발견할 수 없어서 초음파를 통한 횡격막 운동검사가 폐기능 평가의 또다른 생리적 지표로 이용될 수 있음을 시사하였다.

  • PDF