Vibration Analysis of Pump/Turbine and Generator/Motor Rotor System for Pumped Storage Power Stations (양수발전소용 펌프수차${\cdot}$발전기 전동기 축계의 진동해석)

  • Yang, Bo-Suk;Choi, Byung-Gun;Kim, Young-Han;Ha, Hyun-Cheon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.2 s.3
    • /
    • pp.39-45
    • /
    • 1999
  • Pumped-storage power plants pumps the water from the lower reservoir to the upper reservoir using the extra electric power at night and generates electric power in the daytime. Currently it tends to be a high-head large-capacity machine. In this paper, we developed the computer programs for vibration analysis of the pump/turbine and generator/motor rotor system considering electromagnetic force, hydrodynamic unbalance force, dynamic characteristics of guide bearings and add mass of water. This program was verified by applying it to the real model and calculating the critical speed, natural mode and unbalance response.

  • PDF

A Development of Real-time Monitoring Techniques for Synchronous Electric Generator Systems (동기 발전기 시스템의 실시간 모니터링 기술 개발)

  • Cho, Hyun Cheol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.182-187
    • /
    • 2017
  • Synchronous generators have been significantly applied in large-scale power plants and its monitoring systems are additionally established to sequentially observe states and outputs. We develop a computer based monitoring device for three-phase synchronous power generators in this paper. First, a test-bed of such generator system is created and then a interface board is constructed to transfer electric signals including the output voltage and the current from generators into a computer system via a data acquisition device. Its RMS(root-mean-square) values are continuously shown on a screen of computer systems and its time-histories graphs are additionally illustrated under a graphic user interface(GUI) mode. Lastly, we carry out real-time experiments using the generator system with the monitoring device to demonstrate its reliability and superiority by comparing results of a generic power analyzer which is well-used in measuring various power systems practically.

Diesel Generator-Wind Turbine-Battery Modeling Design and Analysis in Synchronous Condenser mode (Diesel Generator-Wind Turbine-Battery 모델링에 관한 설계 및 분석)

  • Kim, Jae-Kyung;Lee, Ji-Young;Lim, Song-Woon;Kim, Yong-Seon;Kim, Jae-Eon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1100_1101
    • /
    • 2009
  • 본 논문은 대표적인 신재생에너지인 풍력발전에 관한 연구의 일환으로 RPM-Sim을 이용한 독립형 하이브리드 발전시스템의 시뮬레이션을 분석하였다. 시뮬레이션에서는 Wind Turbine, Diesel Generator, Rotary Converter, Village Load, Dump Load, PCC를 포함한 독립형 하이브리드 발전시스템을 구현하고, 이 하이브리드 시스템은 신재생에너지 자원인 풍력을 최대한 이용한 발전 시스템으로써 디젤 발전기의 사용을 최소한으로 줄여 부하를 충당할 수 있는 시스템을 구현하여 분석했다.

  • PDF

Operating Characteristics of High Speed PM Synchronous Generator for Microturbine (마이크로터빈용 고속 영구자석 동기발전기 운전 특성)

  • Ahn J. B.;Jeong Y. H.;Kang D. H.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.141-143
    • /
    • 2004
  • Distributed generation(DG) using microturbine will be adopted widely because of its various usages and merits such as high heat efficiency, environmental-friendliness. Commercialized DG using microtubine that rotates up to $60,000\~100,000[rpm]$ converters mechanical power to electricity by permanent magnet synchronous machine. This paper presents comparative test and simulation results of PMSM as generator. Test was done by diode rectifier and inverter. Parameters used in the simulation are driven from FEM analysis. Under various speed and load conditions, V-I characteristics matches well and it suggests the possibility of high speed PMSM as generator. DG operating at stand alone and grid connection mode will be developed.

  • PDF

Switching Characteristics Analysis of Bypass SCR for Series Transformer in 3-phase Voltage Disturbance Generator (3상 전압변동발생기의 직렬변압기 바이패스용 SCR의 스위칭 특성해석)

  • Song, W.H.;Park, H.Y.;Nho, E.C.;Kim, I.D.;Kim, H.G.;Chun, T.W.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.71-72
    • /
    • 2010
  • This paper deals with the SCR thyristor switching characteristics of a 3-phase voltage disturbance generator. The series transformers of the generator require bypass SCR thyristors to provide the source voltage to the output terminal in normal operating mode. The SCR thyristor switching characteristics is quite different according to the connection point to the series transformer. The switching characteristics is analysed and verified through simulation results.

  • PDF

Switching Characteristics Analysis of Bypass SCR for Series Transformer in 3-phase Voltage Disturbance Generator (3상 전압변동발생기의 직렬변압기 바이패스용 SCR의 스위칭 특성해석)

  • Song, W.H.;Park, H.Y.;Nho, E.C.;Kim, I.D.;Kim, H.G.;Chun, T.W.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.532-533
    • /
    • 2010
  • This paper deals with the SCR thyristor switching characteristics of a 3-phase voltage disturbance generator. The series transformers of the generator require bypass SCR thyristors to provide the source voltage to the output terminal in normal operating mode. The SCR thyristor switching characteristics is quite different according to the connection point to the series transformer. The switching characteristics is analysed and verified through simulation results.

  • PDF

Adaptive Sliding Mode Observer for DC-Link Voltage Control of Switched Reluctance Generator without Position Sensor (적응 슬라이딩 모드 관측기를 이용한 Switched Reluctance Generator의 위치 센서 없는 구동에 관한 연구)

  • Choi, Yang-Kwang;Kim, Young-Seok;Kim, Young-Jo;Choi, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.179-182
    • /
    • 2002
  • The position information of the rotor are required while the SRG(Switched Reluctance Generator) is drived. The position information is generally provided by shaft encoder or resolver. But it is weak in the dusty, high temperator and EMI environment. Therefore, the sensor is able to required to eliminated from the SRG. In this paper, a estimation algorithm for the rotor position of the SRG is introducted and a constant DC-link voltage is controled by PID controller. The estimation algorithm is implemened by the adaptive sliding observer and that it is able to estimate the rotor position well is proved by the simulation.

  • PDF

A Study on the Equivalent Dynamic Stiffness of Bearing-pedestal (베어링 대의 등가 동강성에 관한 고찰)

  • Kim, Hee-Soo;Bae, Yong-Chae;Lee, Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.5 s.110
    • /
    • pp.452-456
    • /
    • 2006
  • The critical speeds and mode shapes are most important to determine the behaviors of rotor in designing rotating machinery. As the capacity and span of turbine-generator increases, the turbine-generator system is composed of many components such as bearings, pedestal, turbine and hood and so on. Also, it is getting flexible and has many critical speeds. Especially, as the characteristics of bearing-pedestal are very complicated, they affect the entire vibration characteristics of turbine-generator system. In this paper, it is observed how to determine the equivalent dynamic stiffness of bearing-pedestal by analytical and experimental method.

On-Line and Off-Line Partial Discharge Properties in the Pumped Storage Generator Stator Windings (양수발전기 고정자 권선에서 운전중 및 정지중 부분방전 특성)

  • Kim, Hee-Dong;Ju, Young-Ho;Yoon, Dea-Hen
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2089-2092
    • /
    • 1999
  • Partial discharge(PD) tests were performed both when the pumped storage generator(rated 13.8kV and 220MVA) was on-line and off-line. This generator has been equipped with 12 bus coupler sensors in directional mode. PD tests were conducted using partial discharge analyzer(PDA), partial discharge meter(PDM) and digital partial discharge detector. PDA showed that the patterns of the normalized quantity number(NQN) and the partial discharge magnitude are in accord with on-line and off-line. The insulation condition was estimated by diagnostic tests(off-line) such as PD magnitude and dissipation factor.

  • PDF

Voltage Disturbance Generator for the Test of Custom Power Devices with Nonlinear Load Characteristics (비선형 부하특성을 갖는 전력품질 개선장치의 성능시험을 위한 전압변동발생기)

  • Park, S.D.;Lee, B.C.;Nho, E.C.;Kim, I.D.;Chun, T.W.;Kim, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.935-936
    • /
    • 2006
  • This paper deals with a 3-phase voltage disturbance generator. The proposed generator can be used for the performance teat of custom power devices with nonlinear load characteristics as well as linear load. The principle of the voltage sag, swell, outage, and unbalance generation is described. The switching pattern for the SCR thyristors in each mode is analysed to guarantee the system reliability. The validity of the proposed scheme is verified through simulation result.

  • PDF