• Title/Summary/Keyword: Generator Sensitivity

Search Result 168, Processing Time 0.028 seconds

Generator Scheduling Considering System's Reliability and Demand Response (시스템의 신뢰도와 수요 반응을 고려한 발전 운영)

  • Kwag, Hyung-Geun;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.929-935
    • /
    • 2011
  • Customers hardly change to electric prices in old days because electricity is essential commodity, while demand changes with price after deregulation. It's explained by price-based demand response with demand-elasticity matrix. Also all of the customers have had identical demand-price elasticity matrix till now. But in a practical power system, various customers are present with taking a variety of demand-price elasticity. Therefore this paper proposes demand-price sensitivity to represent different demand-price elasticity. Also as proposing demand-reliability sensitivity, it is modeling various customers' characteristics to reliability. And then this paper calculates total expected interruption cost of customer from the customer interruption cost and the demand-reliability sensitivity. A total expected interruption cost of system is shown as opportunity cost of a generation cost.

Current-controllable saw-tooth waveform generators using current-tunable Schmitt trigger (전류-제어 슈미트 트리거를 이용한 전류-제어 톱니파 발생기)

  • Chung, Won-Sup;Lee, Myung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.7 s.361
    • /
    • pp.31-36
    • /
    • 2007
  • A saw-tooth waveform generator whose frequency can be controlled with a do bias current is proposed. The generator utilizes operational transconductance amplifiers (OTA's) as switching element. It features simple and wide sweep capability The circuit built with commercially avaliable components exhibits good linearity of current-to-frequency transfer characteristics and relatively low temperature sensitivity.

Sensitivity Analysis of Power System Including Series FACTS Device Based on RCF Method (직렬형 FACTS 설비를 포함하는 전력시스템의 RCF 해석법에 기초한 감도해석)

  • Kim, Deok-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.3
    • /
    • pp.624-631
    • /
    • 2011
  • In this paper, the RCF method is used in sensitivity analysis problems of the discrete power systems including both series FACTS equipments such as TCSC in transmission lines and generator controllers such as Exciter and PSS in generator terminal. To apply the RCF method in small signal stability problems of discrete power systems, state transition equations of controllers and TCSC are derived and the sensitivity calculation algorithm using state transition equations in discrete time domain is devised. The results of eigenvalue analysis showed that the variations of eigenvalues after periodic switching operations of TCSC can be calculated exactly by the RCF method and the change of firing angles in TCSC have important effect to determine the stability of power systems.

A Design and Measurement of a Reference Signal Generator for a Radar System

  • Kim, Dong-Sik;Kim, Min-Chul;Lee, Su-Ho;Baik, Seung-Hun;Kwon, Ho-Sang;Jeong, Myung-Deuk
    • Journal of electromagnetic engineering and science
    • /
    • v.9 no.3
    • /
    • pp.118-123
    • /
    • 2009
  • This paper discusses the design and fabrication of a reference signal generator for a naval radar system, including the vibration environment test. The transmit signals of the S-band radar system are synthesized by the reference signal and the phase noise must lower than - 130 dBc/Hz at a 10 kHz offset frequency. To achieve this specification, the phase noise of the reference signal needs to be less than -165 dBc/Hz at a 10 kHz offset. For achieving very low phase noise performance by the reference signal generator, the phase locked loop technique is applied with a 10 Hz loop bandwidth. Also, this reference signal generator has ${\pm}0.35\;ppb$ short-term stability to minimize instant phase errors and high vibration sensitivity against a ship's shaking, unbalanced rotating of antennas and so on.

Positive-Type Photosensitive Polyimide Based on a Photobase Generator Containing Oxime-Urethane Groups as a Photosensitive Compound

  • Jang Young-Min;Seo Ji-Young;Chae Kyu-Ho;Yi Mi-Hye
    • Macromolecular Research
    • /
    • v.14 no.3
    • /
    • pp.300-305
    • /
    • 2006
  • The chemical structure of a semi-aromatic polyimide-I, which was prepared by the chemical imidization of cyclopentanetetracarboxylic dianhydride and 2,2-bis(4-aminophenyl)hexafluoropropane, was characterized by $^{13}C-NMR$ spectroscopy. The chemically imidized polyimide-I was used for the preparation of a photosensitive polyimide (PSPI) through the addition of benzophenone and benzophenone oxime hexamethylene diurethane (BOHD), a photobase generator containing oxime-urethane groups. The polyimide-I film containing benzophenone and BOHD was not soluble in 2.38 wt% tetrabutylammonium hydroxide solution in $H_2O$. However, it became soluble following irradiation with 310 nm UV light. A positive tone image with a resolution of $5{\mu}m$ was obtained with this PSPI, having sensitivity($D_c$) of $1.2J/cm^2$ and contrast(${\gamma}_p$) of 1.08. Thus, a polyimide, which is not intrinsically photosensitive, can become photosensitive through the addition of a photobase generator containing oxime-urethane groups as a photosensitive compound.

Fuzzy PSO Congestion Management using Sensitivity-Based Optimal Active Power Rescheduling of Generators

  • Venkaiah, Ch;Vinod Kumar, D M
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.32-41
    • /
    • 2011
  • This paper presents a new method of Fuzzy Particle Swarm Optimization (FPSO)-based Congestion Management (CM) by optimal rescheduling of active powers of generators. In the proposed method, generators are selected based on their sensitivity to the congested line for efficient utilization. The task of optimally rescheduling the active powers of the participating generators to reduce congestion in the transmission line is attempted by FPSO, Fitness Distance Ratio PSO (FDR-PSO), and conventional PSO. The FPSO and FDR-PSO algorithms are tested on the IEEE 30-bus and Practical Indian 75-bus systems, after which the results are compared with conventional PSO to determine the effectiveness of CM. Compared with FDR-PSO and PSO, FPSO can better perform the optimal rescheduling of generators to relieve congestion in the transmission line.

Fabrication of a Multiplexing Sensor Probe for Measuring the Blade Deflection of a Wind Power Generator (풍력발전기 블레이드 처짐 측정을 위한 다중화 센서 탐촉자 설계 제작)

  • Kim, Ji-Dea;Lee, Dong-Ju
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.2
    • /
    • pp.178-185
    • /
    • 2014
  • This paper describes a fabrication multiplexing sensor probe that employs a fiber Bragg grating(FBG) based on multiple measurements to determine the blade deflection of a wind power generator the reliability analysis of this probe is also presented. To diminish the temperature sensitivity of the FBG sensor, we form multiple CFRPs onto the upper and lower layers of the FBG and package it with an epoxy resin. As a result, the depth of the CFRP is 1mm, and the temperature sensitivity is $2.39pm/^{\circ}C$. We construct a sensor network utilizing the fabricated sensor with a blade beam model. As the number of pendulums is increased on the fore-end of the beam, the strain value is measured. The strain variation is calculated from the measurement of the load on the blade beam model by monitoring the strain of the FBG sensor. When the linear equation is applied, the strain error is 0.4% and when the finite difference method is used, the tip deflection error is 3.3%. The displacement error derived from the strain value of the FBG sensor is 4.39%. The calculated result between the measured value of the dead-end of the beam and the strain is less than 2.46% tip distortion error. Therefore, our proposed multiplexing sensor probe is a low-cost and high-reliability solution for a commercial wind power generator.

Sensitivity Analysis for Using Gas Turbine Generator to Provide Alternate Alternating Current in APR+ (APR+ 대체교류발전기의 가스터빈 적용에 대한 민감도분석)

  • Moon, Ho-Rim;Park, Bhum-Lak;Park, Young-Sheop
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.1
    • /
    • pp.97-102
    • /
    • 2012
  • Alternate alternating current (AAC) is used in nuclear power plants (NPPs) in order to cope with station black outs (SBOs). AAC has been provided using diesel engine drive types in Korea's NPPs. The structure of gas turbine generators (GTGs) is simpler than that of diesel generators (DGs), and GTGs have the advantage of longer maintenance intervals. However, GTG-AAC was not used in NPPs in Korea because of the lack of operation/maintenance experience. The purpose of this paper is to analyze the safety of APR+ considering a diversity of AAC types. This paper analyzes reliability data, mechanical specifications of DGs and GTGs, and the sensitivity of core damage frequency to the ACC type.

Research on a Stability of Feedwater Control System after Stretched Power Uprate and Replacement Steam Generator for Ulchin Units 1&2 (울진1,2호기 출력최적화 및 증기발생기 교체가 주급수 제어계통 안정도에 미치는 영향연구)

  • Yoon, Duk-Joo;Kim, In-Hwan;Kim, Sang-Yeol
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.2
    • /
    • pp.14-20
    • /
    • 2012
  • Full load rejection capability of nuclear power plant depends primarily on steam dump capacity (SDCAP) and steam generator level control capability. Recently, Ulchin Units 1&2 have performed stretched power uprate (SPU) and replacement steam generator (RSG) projects, which increase the power by 4.5 percent. They change major design or operating parameters and especially reduces steam dump capacity at full power due to increase of the steam flow. The reduction of SDC after SPU results in degradation of heat removal capability in full load rejection transients. Therefore, we should perform evaluation to determine whether reactor trips occur in large load rejection transients. Uchin Units 1&2 have experienced full load rejection (FLR) three times from 2004 to 2010. Operating data from the plant occurrence of FLR at Ulchin Units 1&2 showed that steam generator (SG) level transients were limiting in point of reactor trip. However the plant had never reached reactor trip in the FLR and successfully continued in house load operation. The parameters and setpoints for the SG will be changed if the SG is replaced. Therefore, we evaluated the appropriateness of steam dump, main feedwater and steam generator water level control system preventing the plant from reactor trip in case of FLR by the parameter sensitivity study whether SG water level operated smoothly after SPU and RSG projects.