• 제목/요약/키워드: Generator Sensitivity

검색결과 167건 처리시간 0.022초

구성 물질에 따른 3D 프린팅 팬텀의 적용 평가 (Evaluation of Application of 3D Printing Phantom According to Manufacturing Method )

  • 김영상;이주영;박훈희
    • 방사선산업학회지
    • /
    • 제17권2호
    • /
    • pp.173-181
    • /
    • 2023
  • 3D printing is a technology that can transform and process computerized data obtained through modeling or 3D scanning via CAD. In the medical field, studies on customized 3D printing technology for clinical use or patients and diseases continue. The importance of research on filaments and molding methods is increasing, but research on manufacturing methods and available raw materials is not being actively conducted. In this study, we compare the characteristics of each material according to the manufacturing method of the phantom manufactured with 3D printing technology and evaluate its usefulness. We manufactured phantoms of the same size using poly methyl meta acrylate (PMMA), acrylonitrile butadiene styrene (ABS), and Poly Lactic Acid (PLA) based on the international standard phantom of aluminum step wedge. We used SITEC's radiation generator (DigiRAD-FPC R-1000-150) and compared the shielding rate and line attenuation coefficient through the average after shooting 10 times. As a result, in the case of the measured dose transmitted through each phantom, it was confirmed that the appearance of the dose measured for phantoms decreased linearly as the thickness increased under each condition. The sensitivity also decreased as the steps increased for each phantom and confirmed that it was different depending on the thickness and material. Through this study, we confirmed that 3D printing technology can be usefully used for phantom production in the medical field. If further development of printing technology and studies on various materials are conducted, it is believed that they will contribute to the development of the medical research environment.

대기중의 암모니아 및 암모늄염의 필터포집법에 관한 연구 (Study on the Filter Collection Methods of Ammonia and Ammonium Salts in the Atomosphere)

  • 김희강;교본방일;이용근
    • 대한화학회지
    • /
    • 제26권1호
    • /
    • pp.36-42
    • /
    • 1982
  • 대기중의 암모니아가스와 암모늄염의 필터포집법에 관하여 연구하였다. 표준가스 발생장치로 발생시킨 암모니아가스를 3% 붕산-25% 글리세린 혼합액이 스며든 유리섬유 필터에 포집하였다. pH조절법으로 발생시킨 암모니아가스와 대기중의 암모니아를 5회씩 포집하여 측정한 결과 포집효율은 각각 96.4${\pm}$ 2.15%와 97.4${\pm}$1.06%였다. 시판되는 유리섬유 필터 및 Polycarbonate 필터에 대하여 암모니아가스의 흡착 및 탈리현상을 검토한 결과 유리섬유 및 석영 섬유 필터에서는 암모니아가스의 흡착과 약간의 암모늄염이 탈리되었으나, Polycarbonate 필터는 대기중의 암모늄염을 포집하는데 적합한 것으로 판단되었다. 지름 47mm의 필터에 20l/min의 유량으로 60분동안 대기를 포집하여 인도페놀법에 의한 분광광도법으로 측정 할 경우, 측정가능한 암모니아가스의 최저농도는 0.83ppb (약 0.63$\mug$/$m^3$)이다. 이 방법은 종래의 용액포집법에 의한 분광광도 측정법에 비하여 감도가 20배나 높으므로 대기중의 암모니아 농도의 변화를 단시간(약 60분)내에 측정할 수 있다.

  • PDF

Shell 석탄가스화 복합발전 시스템의 성능해석 연구 (Performance Analysis of Shell Coal Gasification Combined Cycle systems)

  • Kim, Jong-Jin;Park, Moung-Ho;Song, Kyu-So;Cho, Sang-Ki;Seo, Seok-Bin;Kim, Chong-Young
    • 에너지공학
    • /
    • 제6권1호
    • /
    • pp.104-113
    • /
    • 1997
  • 본 연구에서는 상용공정모사기인 ASPEN PLUS를 이용하여 건식탄공급, 산소사용 분류층 가스화기인 Shell가스화공정, 저온가스정제공정, GE MS7001FA가스터빈, 삼압.자연순환식 폐열회수보일러, 재열복수식 증기터빈 및 극저온 산소분리공정을 채용한 IGCC시스템에 대하여 성능해석 모델을 개발하고 시스템 성능해석을 위한 민감도분석을 수행하였다. 본 모델의 적정성은 설계조건에서 대상탄을 이용한 정상상태 성능해석 결과를 타 시뮬레이션 결과와 비교함으로서 검증하였다.$^{1)}$ . Illinois#6탄을 대상으로 수행한 시뮬레이션 결과는 투입되는 탄에 함유된 수분의 양이 증가함에 따라 가스화기의 온도가 감소하며, 회분 및 황이 많은 경우에 현열손실이 증가하여 시스템 효율이 감소하였다. 개발된 모델을 이용하여 가스화기의 운전압력, 증기/석탄비율 및 산소/석탄비율에 따르는 시스템의 민감도분석을 수행한 결과 운전압력 증가에 따라 가스화기 노내온도가 상승하며, 가연성가스(CO+H2) 생성율이 감소하였다. 증기/석탄비율 변화분석에서는 공급증기의 양을 변화시키면 가연성가스의 최고생성점이 보다 낮은 산소/석탄비율에서 나타남을 알 수 있었다. 또한 산소/석탄비율 변화분석에서는 증기/석탄 공급비율 0.2에서 산소/석탄 공급비율이 0.77인 경우에 가장 최적의 운전조건임을 알 수 있었다.

  • PDF

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • 한국결정학회:학술대회논문집
    • /
    • 한국결정학회 2002년도 정기총회 및 추계학술연구발표회
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

신경망과 퍼지논리를 이용한 최대수요전력 제어시스템에 관한연구 (A Study on the Control System of Maximum Demand Power Using Neural Network and Fuzzy Logic)

  • 조성원
    • 한국지능시스템학회논문지
    • /
    • 제9권4호
    • /
    • pp.420-425
    • /
    • 1999
  • 최대수요전력 예측과 제어의 목적은 공장 또는 빌딩등의 전력수용가의 입장에서 수시로 변동하는 부하의추이를 파악 예측하여 에너지 합리화 경제성 증대 산업기기의 보호 수용가의 비용절감과 더불어 크게는 국가적인 전력시스템안정화를 가져가기 위함에 있다. 최대수요전력 예측/제어를 위한 기존의 방법들은 수용가 특성이나 계절별 요일별 차이를 고려하지 않고 고정된 알고리즘에 의해 예측값이 결정되므로 환경변화에 적극적인 대응능력이 부족한 단점이있다. 이와같은 문제점의 해결을 위해 본 논문에서는 현재 많은 연구가 되고 있는 SOFM 신경망을 이용한 예측 방법과 예측치의 보정방법으로 퍼지제어길르 추가한 형태의 최대수요전력예측 제어기를 제안한다, 예측방법의 경우 유동적이며 적은 구간을 통하여 순시부하처럼 변동이 많은 데이터에 대하여 예측시간을 단축함과 동시에 오차를 줄여나갈수 있다. 또한 2단계의 학습을 통하여 SOFMd의 출력값이 패턴이 아닌 예측치가 될 수 있도록 변형하였으며 패턴자체의 변화에 대응하여 패턴오차를 이용하여재학습을 하도록 하여 불안정한 전력에 대하여 보완한다. 그리고 예측후반부에 퍼지제어기를 연결하여 예측의 신뢰성을 높이는 안정된 예측구조를 가지고 있다. 실험결과 시계열 예측방법인 지수평활법보다 제안된 예측/제어 방법이 우수함을 확인하였다.

  • PDF

EPR/알라닌 선량계를 이용한 치료용 선형가속기 정도관리 활용 연구 (Research on the use of Therapeutic Linear accelerator Quality Control using EPR/alanine Dosimeter)

  • 김윤하;김효진;강영록;이동연
    • 한국방사선학회논문지
    • /
    • 제18권3호
    • /
    • pp.239-248
    • /
    • 2024
  • 방사선치료는 고에너지를 사용함으로 인체에 부작용이 발생할 수 있다. 이에 따라 적정 선량의 설정과 발생장치에서 만들어진 방사선에 대한 신뢰도를 확보하는 것이 중요하다. EPR/알라닌 선량평가는 물 동등성, 선량 응답 선형성과 낮은 페이딩 등의 장점이 있으므로 방사선치료 장비의 품질관리에서 유용하게 사용될 것으로 생각한다. 따라서 본 연구에서는 선형가속기 6 MV 에너지를 활용하여 알라닌의 질량에 따른 EPR/알라닌 선량평가의 신호와 선량반응곡선을 비교하였다. 조사된 알라닌 선량계의 EPR 신호를 통해 선량반응곡선과 1차 회귀방정식을 제작하였다. 이를 통해 질량에 따른 신호 크기와 선량반응곡선을 비교하고 선량반응곡선 측정 불확도를 통해 신뢰도를 확인하였다. 그 결과, 질량이 커짐에 따른 EPR 신호의 크기는 64.5 mg 기준으로 약 1.3배 증가하며, 선량반응곡선의 민감도도 커지는 것을 알 수 있었다. 측정 불확도는 5.84 ~ 8.93 % (신뢰구간 약 95 %, k=2)로 평가되었다. 본 연구를 통해 선형가속기의 품질보증과 품질관리에 EPR/알라닌 선량평가 시스템이 적용 가능할 것으로 생각된다.

적대적 생성 모델을 활용한 사용자 행위 이상 탐지 방법 (Anomaly Detection for User Action with Generative Adversarial Networks)

  • 최남웅;김우주
    • 지능정보연구
    • /
    • 제25권3호
    • /
    • pp.43-62
    • /
    • 2019
  • 한때, 이상 탐지 분야는 특정 데이터로부터 도출한 기초 통계량을 기반으로 이상 유무를 판단하는 방법이 지배적이었다. 이와 같은 방법론이 가능했던 이유는 과거엔 데이터의 차원이 단순하여 고전적 통계 방법이 효과적으로 작용할 수 있었기 때문이다. 하지만 빅데이터 시대에 접어들며 데이터의 속성이 복잡하게 변화함에 따라 더는 기존의 방식으로 산업 전반에 발생하는 데이터를 정확하게 분석, 예측하기 어렵게 되었다. 따라서 기계 학습 방법을 접목한 SVM, Decision Tree와 같은 모형을 활용하게 되었다. 하지만 지도 학습 기반의 모형은 훈련 데이터의 이상과 정상의 클래스 수가 비슷할 때만 테스트 과정에서 정확한 예측을 할 수 있다는 특수성이 있고 산업에서 생성되는 데이터는 대부분 정답 클래스가 불균형하기에 지도 학습 모형을 적용할 경우, 항상 예측되는 결과의 타당성이 부족하다는 문제점이 있다. 이러한 단점을 극복하고자 현재는 클래스 분포에 영향을 받지 않는 비지도 학습 기반의 모델을 바탕으로 이상 탐지 모형을 구성하여 실제 산업에 적용하기 위해 시행착오를 거치고 있다. 본 연구는 이러한 추세에 발맞춰 적대적 생성 신경망을 활용하여 이상 탐지하는 방법을 제안하고자 한다. 시퀀스 데이터를 학습시키기 위해 적대적 생성 신경망의 구조를 LSTM으로 구성하고 생성자의 LSTM은 2개의 층으로 각각 32차원과 64차원의 은닉유닛으로 구성, 판별자의 LSTM은 64차원의 은닉유닛으로 구성된 1개의 층을 사용하였다. 기존 시퀀스 데이터의 이상 탐지 논문에서는 이상 점수를 도출하는 과정에서 판별자가 실제데이터일 확률의 엔트로피 값을 사용하지만 본 논문에서는 자질 매칭 기법을 활용한 함수로 변경하여 이상 점수를 도출하였다. 또한, 잠재 변수를 최적화하는 과정을 LSTM으로 구성하여 모델 성능을 향상시킬 수 있었다. 변형된 형태의 적대적 생성 모델은 오토인코더의 비해 모든 실험의 경우에서 정밀도가 우세하였고 정확도 측면에서는 대략 7% 정도 높음을 확인할 수 있었다.