• 제목/요약/키워드: Generator Sensitivity

검색결과 167건 처리시간 0.024초

전력계통 구조를 고려한 발전기 무효예비력 산정 (Calculation of Generator Reactive Reserve Considering Network Configuration)

  • 서상수;김대정;최윤혁;이병준
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.711-716
    • /
    • 2011
  • This paper defines a generator reactive reserve considering power system network. Conventional generator reserve is calculated by the difference between the maximum reactive power output of generator and the current reactive power of generator. However, all generators could not affect on the whole power system. Thus, the effective generators should be selected by sensitivity analysis. The sensitivity depends on network configuration is the relation between generator reactive power outputs and reactive power loads. Using the sensitivity, the effective generator reactive reserve can be calculated.

2MW급 직접구동형 풍력발전기의 풍황 민감도 및 토크모드 스위칭 성능 해석 (A Sensitivity and Performance Analysis for Torque Mode Switching on 2MW Direct Drive Wind Turbine Generator)

  • 노주현
    • 전기학회논문지
    • /
    • 제63권10호
    • /
    • pp.1455-1460
    • /
    • 2014
  • Wind turbine generators were designed on general regulations of wind condition. At real situations, it could be different from the design conditions. There are many control methods and definitions of transient region, because an efficient wind turbine generator control logic is the important matter in generator performance and annual energy production at real conditions. In this document, the power generation sensitivity for wind speed and turbulence intensities was defined to know the sensitive transient region. Wind conditions are applied for the ranges of 7~10m/s mean wind speed and 14~20% turbulence intensity. The sensibility of HR-D86 wind generator was increased in transient region(8~10m/s) on power curve diagram through a torque control to a pitch control. And then GH-bladed simulations was performed for performance analysis of the torque mode switching in transient region on 2MW direct drive wind generator(HR-D86) which is designed IEC class II for onshore. Through the sensitivity and performance analysis, the sensitivity for real wind condition could be the performance index for an wind generator. And the torque mode switching in transient region can increase the mean power generation on HR-D86 wind turbine generator.

발전기 모델링 정도에 의한 고유치 일차${\cdot}$이차 감도계수 비교 (Comparison of the first and the second order eigenvalue sensitivity coefficients affected by generator modeling)

  • 김덕영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.345-347
    • /
    • 2004
  • In small signal stability analysis of power systems, eigenvalue analysis is the most useful method and the detailed modeling of generator has an important effect to the eigenvalues. Generator full model is used for precise dynamic analysis of generators and controllers while two-axis model is used for multi-machine systems because of the reduced order of the state matrix. Also, the eigenvalue sensitivity coefficients are used for optimizing controller parameters to improve system stability. This paper compare the first and second order eigenvalue sensitivity coefficients of controllers using generator full model with those of two-axis model. As a result of an example, the estimated eigenvalues using the first and the second eigenvalue sensitivity coefficients using generator full model is very close to those of state matrix. Also the error ratios throughout a wide range of controller parameters is less than $1\%$.

  • PDF

발전기 모델링 정도에 의한 고유치 감도계수에 미치는 영향해석 (Analysis of the first order eigenvalue sensitivity affected by generator model)

  • 조언중;이군재;김덕영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.119-121
    • /
    • 2003
  • In small signal stability analysis of power systems, eigenvalue analysis is the most useful method and the detailed modeling of generator gives an important effect to the eigenvalues. Generator full model is used for precise dynamic analysis of generators and controllers while two-axis model is used for multimachine systems because of the reduced order of the state matrix. Also, the eigenvalue sensitivity coefficients are used for optimization of controller parameters to improve system stability. This paper compare the first order eigenvalue sensitivity coefficients of controllers in case of generator full model with those of two-axis model. As a result of an example the estimated eigenvalues using sensitivity coefficients in case of generator full model is very close to those of state matrix within 1% error ratios.

  • PDF

민감도 분석에 기초한 대규모 전력계통의 예방정비계획 방법론 개발 (Large-scale Generator Maintenance Scheduling via Sensitivity Analysis Method)

  • 정만호;박종배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1020-1023
    • /
    • 1998
  • This paper presents a new approach to large-scale optimal generator maintenance scheduling. To do this, we developed a kind of discrete sensitivity index of each generator by using difference of objective fuction when it is on and off status. Based on the sensitivity value, we applied the conventional priority approach as an optimization method in the order of each generator's sensitivity measure. By applying the developed method, we can efficiently search the state space and dramatically reduce the computation time in a large scale power system.

  • PDF

750kW Gearless PM 동기발전기 로터프레임 경량화 (Structural optimization for rotor frame of 750kW gearless type PMSG)

  • 홍혁수;박진일;류지윤
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.286-289
    • /
    • 2008
  • Mass of generator is one of the most important characteristic value especially direct drive type wind turbine. This paper introduce how to decease mass of generator rotor frame without declining generator performance. To obtain optimal design of rotor frame, sensitivity analysis using Taguchi method and RSM(response surface method) are have been performed.

  • PDF

발전기 제어장치와 TCSC를 포함하는 이산 전력시스템의 고유치 감도해석 (Eigenvalue Sensitivity Analysis of Discrete Power Systems Including Generator Controllers and TCSC)

  • 김덕영
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.193-200
    • /
    • 2010
  • In this paper, the eigenvalue sensitivity analysis is calculated in the power system which is including both generator controllers such as Exciter, PSS and thyristor controlled FACTS devices in transmission lines such as TCSC. Exciter and PSS are continuously operating controllers but TCSC has a switching device which operates non-continuously. To analyze both continuous and non-continuous operating equipments, the RCF method one of the numerical analysis method in discrete time domain is applied using discrete models of the power system. Also the eigenvalue sensitivity calculation algorithm using state transition equations in discrete time domain is devised and applied to a sampled system. As a result of simulation, the eigenvalue sensitivity coefficients calculated using discrete system models in discrete time domain are changed periodically and showed different values compared to those of continuous system model in time domain by the effect of periodic switching operations of TCSC.

OTA를 이용한 전류-제어 톱니파 발생기 (Current-controllable saw-tooth waveform generator using OTA's)

  • 임동빈;정원섭;송재훈;김희준
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.177-180
    • /
    • 2001
  • A saw-tooth waveform generator with current-controllable frequency is described. The generator utilizes operational transconductance amplifiers as switching element. It features simple and wide sweep capability. The circuit built with commercially avaliable components exhibits good linearity of current to frequency and relatively low temperature sensitivity.

  • PDF

민감도를 이용하여 풍력단지가 연계된 송전계통의 최적혼잡처리 (Optimal Congestion Management Based on Sensitivity in Power System with Wind Farms)

  • 최수현;김규호
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.1965-1970
    • /
    • 2016
  • This paper studies generator rescheduling technique for congestion management in power system with wind farms. The proposed technique is formulated to minimize the rescheduling cost of conventional and wind generators to alleviate congestion subject to operational line overloading. The generator rescheduling method has been used with incorporation of wind farms in the power system. The locations of wind farms are selected based upon power transfer distribution factor (PTDF). Because all generators in the system do not need to participate in congestion management, the rescheduling has been done by generator selection based on the proposed generator sensitivity factor (GSF). The selected generators have been rescheduled using linear programming(LP) optimization techniques to alleviate transmission congestion. The effectiveness of the proposed methodology has been analyzed on IEEE 14-bus systems.

이명과 청각민감증을 동반한 편측 고음 급추형 감각신경성 난청의 청각 재활 (Clinical Report of Aural Rehabilitation in Unilateral Sharply Slop Sensorineural Hearing Loss with Tinnitus and Increased Sound Sensitivity)

  • 허승덕;강명구;고도흥;정동근
    • 음성과학
    • /
    • 제11권3호
    • /
    • pp.175-180
    • /
    • 2004
  • In case of the hearing impairment with tinnitus and increased sound sensitivity, it is known that the patients tend to appeal the psychologically oriented social handicap rather than communication disability. The audiologist who is responsible for such patients in aural rehabilitation should pay special attention to the counseling techniques including tinnitus retain therapy (TRT), ear protector, noise generator, or specific acoustic training based on close cooperation and rapport. And then the audiologist should try to lessen their reaction to the tinnitus by using a hearing aid. This therapies tries to focus not a. total approach but a treatment to lessen the severity of tinnitus. This paper as a case report that a unilateral sharply slopped sensorineural hearing impaired person with tinnitus and increased sound sensitivity by using four channel digital signal processing (DSP) hearing aid with programming increment at low level (PILL).

  • PDF