• 제목/요약/키워드: Generation rate

검색결과 3,001건 처리시간 0.03초

$YCa_4O(BO_3)_3$ 비선형광학 단결정 성장 및 Second Harmonic Generation 소자 제조에 관한 연구 (Crystal Growth of $YCa_4O(BO_3)_3$ and Preparation of Device for Second Harmonic Generation)

  • 유영문;;장석종;장원권;임기수
    • 한국결정학회지
    • /
    • 제11권1호
    • /
    • pp.16-21
    • /
    • 2000
  • (Yb/sub x/Y/sub 1-x/)Ca₄O(BO₃)₃ single crystals where x=0.3,8,15,20% were grown by Czochralski Method. The crystals grown under the optimum conditions were transparent and colorless with good crystal form. Using polarizing microscope, crystal defects such as parasite crystals and bubbles were detected depending on the composition of melts and pulling rates. The optimum growth parameters for high quality of single crystals were 15∼20 rpm of rotation rate and 2mm/h of pulling rate at the flow rate of 2 l/min of Nitrogen gas. The relationship between crystal axes and optical axes was investigated by optical crystallographic method, polarization technique and single crystal X-ray method. From the spectroscopic measurements, it was confirmed that there were strong absorption bands at 900 and 976.4 nm and strong emission band at 976.4 nm in Yb/sup 3+/ ion doped YCa₄O(BO₃)₃ crystal. For the application of second harmonic generation of 1.064 ㎛ laser, non-linear optical devices with θ=32.32° and Ψ=0°, λ/10 of flatness and the size of 6x8x5.73 mm were fabricated from the grown YCa₄O(BO₃)₃ crystal.

  • PDF

수평단관 상의 유하액막 열전달 (Falling Film Heat Transfer on a Horizontal Single Tube)

  • 김동관;김무환
    • 설비공학논문집
    • /
    • 제12권7호
    • /
    • pp.642-648
    • /
    • 2000
  • Falling film heat transfer analyses with aqueous lithium bromide solution were peformed to investigate the transfer characteristics of the copper tubes. Finned(knurled) tube and a smooth tube were selected as test specimens. Averaged generation fluxes of water and the heat transfer performances(heat flux, heat transfer coefficient) were obtained. The results of this work were compared with the data reported previously. As the film flow rate of the solution increased, the generation fluxes of water decreased for both tubes. The reason is estimated by the fact that the heat transfer resistance with the film thickness increased as the film flow rate increased. The effect of the enlarged surface area at the knurled tube was supposed to be dominant at a small flow rate. The generation fluxes of water increased with the increasing degree of tube wall superheat. Nucleate boiling is supposed to occur at a wall superheat of 20 K for a smooth tube, and at 10 K for a knurled tube. The heat transfer performance of the falling film was superior to pool boiling at a low wall superheat below 10 K for both tubes tested. The knurled tube geometry showed good performance than the smooth tube, and the increased performance was mainly came from the effect of the increased heating surface area.

  • PDF

전해부상을 이용한 활성슬러지의 탈수성 향상 (Improvement of Activated Sludge Dewaterability by Electro-flotation)

  • 최영균;박병주;박민정;김윤중;정태학
    • 상하수도학회지
    • /
    • 제20권5호
    • /
    • pp.677-684
    • /
    • 2006
  • Electro-flotation(EF), a novel sludge thickening method, could improve the dewaterability of activated sludge. The gas(microbubbles) generated during EF decreased the solid-liquid separation time below 1/5 of the time required for gravity sedimentation. In addition, over 90% of the sludge volume reduction could be achieved by EF although the settling characteristics of the sludge was very poor. The SRF(specific resistance to filtration) of the thickened sludge by EF was much lower than that of the sludge thickened by gravity sedimentation. The SRF of the thickened sludge decreased exponentially with increase of gas generation rate of the EF system. Gas generation rate could be controlled by varying the current density of the electrode. Degasing of the microbubbles by vigorous mixing of the thickened sludge layer deteriorated the dewaterability of the sludge. Therefore, it is obvious that the gas bubbles entrapped in the thickened sludge play a key role in the observed dewaterability improvement.

2상 흐름계에서 유로설계에 따른 전해조 분리판의 전산모사 연구 (A study on the channel design of bipolar plate of electrolytic cell by flow dynamic simulation in the two phase flow system)

  • 조현학;장봉재;송주영
    • 한국응용과학기술학회지
    • /
    • 제27권4호
    • /
    • pp.415-420
    • /
    • 2010
  • This study is focused on the channel design of bipolar plate in the electrode of hydrogen gas generator. The characteristics of hydrogen gas generation was studied in view of efficiency of hydrogen gas generation rate and a tendency of gas flow through the riv design of electrode. Since the flow rate and flow pattern of generated gas in the two phase flow system are the most crucial in determining the efficiency of hydrogen gas generator, we adopted the commercial analytical program of COMSOL MultiphysicsTM to calculate the theoretical flow rate of hydrogen gas from the outlet of gas generator and flow pattern of two phase fluid in the electrode. In this study, liquid electrolyte flows into the bipolar plate and decomposed into gas phase, two phase flow simulation is applied to measure the efficiency of hydrogen gas generation.

주파수변화율을 이용한 제주계통 부하차단 방안 (A Scheme for the Load Shedding on Cheju Power Systems using Rate of Change of Frequency)

  • 장병태;이소영;조경보;곽노홍;안정식;오화진;조범섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.184-186
    • /
    • 2003
  • Power systems must be operated within limits that will ensure adequate generation and transmission capacity to avoid cascading. In developing a set of operations limits, it is important to do so within a general framework in order to ensure that the operating objectives are met. In the this regard, when the system experiences a generation-load imbalance, the principles of sound operation will be maintained by bringing under control an unscheduled power flow condition as quickly as possible. This paper presents load shedding application which responds both to frequency and to rate of change of frequency. Its application is in the operating situation of load suddenly in excess of generation, either because of generator or other equipment failure. A scheme which is able to utilize rate of change of frequency as well as frequency itself is an improvement over existing scheme.

  • PDF

Pilot 규모 석탄 가스화기에서의 탄종별 가스화성능 특성 (Effects of Different Coal Type on Gasification Characteristics)

  • 박세익;이중원;서혜경
    • 한국수소및신에너지학회논문집
    • /
    • 제21권5호
    • /
    • pp.470-477
    • /
    • 2010
  • The IGCC (Integrated gasification combined cycle) is known for one of the highest efficiency and the lowest emitting coal fueled power generating technologies. As the core technology of this system is the gasifier to make the efficiency and the continuous operation time increase, the research about different coal's gasification has been conducted. Our research group had set-up the coal gasifier for the pilot test to study the effect of different coals-Shenhua and Adaro coal- on gasification characteristics. Gasification conditions like temperature and pressure were controlled at a fixed condition and coal feed rate was also controlled 30 kg/h to retain the constant experimental condition. Through this study we found effects of coal composition and $O_2$/coal ratio on the cold gas efficiency, carbon conversion rate. The compounds of coal like carbon and ash make the performance of gasifier change. And carbon conversion rate was decreased with reduced $O_2$/coal ratio. The optical $O_2$/coal ratio is 0.8 for the highest cold gas efficiency approximately. At those operating conditions, the higher coal has the C/H ratio, the lower syn-gas has the $H_2$/CO ratio.

파력발전용 횡류형 수력터빈의 성능 및 내부유동 (Performance and Internal Flow of a Cross-Flow Type Hydro Turbine for Wave Power Generation)

  • 최영도;조영진;김유택;이영호
    • 한국유체기계학회 논문집
    • /
    • 제11권3호
    • /
    • pp.22-29
    • /
    • 2008
  • Clean and renewable energy technologies using ocean energy give us non-polluting alternatives to fossil and nuclear-fueled power plants to meet establishment of countermeasures against the global warming and growing demand for electrical energy. Among the ocean energy resources, wave power takes a growing interest because of its enormous amount of potential energy in the world. Therefore, various types of wave power conversion system to capture the energy of ocean waves have been developed. However, suitable turbine type is not normalized yet because of relatively low efficiency of the turbine systems. The purpose of this study is to investigate the internal flow and performance characteristics of a cross-flow type hydro turbine, which will be built in a caisson for wave power generation. Numerical simulation using a commercial CFD code is conducted to clarify the effects of the turbine rotation speed and flow rate variation on the turbine characteristics. The results show that the output power of the cross-flow type hydro turbine with symmetric nozzle shape is obtained mainly from Stage 2. Turbine inlet configuration should be designed to obtain large amount of flow rate because the static pressure and absolute tangential velocity are influenced considerably by inlet flow rate.

오존발생기의 특성 연구 및 모니터링 시스템 구축 (A Study on the Characteristics of Ozonizers and Implementation of a Monitoring System)

  • 김용철;김규식;최주엽
    • 전력전자학회논문지
    • /
    • 제6권5호
    • /
    • pp.460-466
    • /
    • 2001
  • 오존의 산화력은 상용의 산화제중에서 가장 강력하고 따라서 수처리에서 염소를 대체해 가고 있다. 또한, 수처리 시 효율적인 에너지절감을 위해서도 고농도의 오존이 요구되고 무성방전 오존발생기가 산업체에서 효과적이고 가장 널리 사용된다. 본 연구에서 오존방전전압, 주파수, 오존방전관 내의 온도 등이 오존발생율을 결정짓는 주요한 변수임을 확인하였다. 이들 변수들을 효과적으로 제어하기 위해 그래픽사용자 인터페이스를 갖는 모니터링 시스템을 구축하였다. 이 시스템은 윈도우 98에서 C++과 LabView로 프로그램 하였다.

  • PDF

온도와 반응 시간에 따른 세라믹 튜브 내 메탄 열분해 반응의 메탄 전환율과 선택도 분석 (Analysis of Methane Conversion Rate and Selectivity of Methane Pyrolysis Reaction in Ceramic Tube According to Temperature and Reaction Time)

  • 이동근;김영상;안국영
    • 한국수소및신에너지학회논문집
    • /
    • 제33권1호
    • /
    • pp.1-7
    • /
    • 2022
  • Interest in hydrogen productions that do not emit carbon dioxide and can produce hydrogen at a low price is increasing. Reforming and electrolysis are widely used, but they have limitations, such as carbon dioxide problems and costs. The methane can be decomposed as hydrogen and solid carbon without carbon dioxide emission at high temperatures. In this research, the methane pyrolysis experiment was conducted at 1,200℃ and 1,400℃ in a ceramic tube. The composition of the produced gas was measured by gas chromatography before carbon blocked the tube. The methane conversion rate and hydrogen selectivity were calculated based on the results. The hydrogen selectivity was derived as 60% and 55% at the highest point at 1,200℃ and 1,400℃, respectively. The produced solid carbon was expected to be carbon black and was analyzed using scanning electron microscope.

Control strategies of energy storage limiting intermittent output of solar power generation: Planning and evaluation for participation in electricity market

  • Sewan Heo;Jinsoo Han;Wan-Ki Park
    • ETRI Journal
    • /
    • 제45권4호
    • /
    • pp.636-649
    • /
    • 2023
  • Renewable energy generation cannot be consistently predicted or controlled. Therefore, it is currently not widely used in the electricity market, which requires dependable production. In this study, reliability- and variance-based controls of energy storage strategies are proposed to utilize renewable energy as a steady contributor to the electricity market. For reliability-based control, photovoltaic (PV) generation is assumed to be registered in the power generation plan. PV generation yields a reliable output using energy storage units to compensate for PV prediction errors. We also propose a runtime state-ofcharge management method for sustainable operations. With variance-based controls, changes in rapid power generation are limited through ramp rate control. This study introduces new reliability and variance indices as indicators for evaluating these strategies. The reliability index quantifies the degree to which the actual generation realizes the plan, and the variance index quantifies the degree of power change. The two strategies are verified based on simulations and experiments. The reliability index improved by 3.1 times on average over 21 days at a real power plant.