• Title/Summary/Keyword: Generating device

Search Result 328, Processing Time 0.03 seconds

Effects on bycatch reduction in a shaking cod end generated by canvas in a shrimp beam trawl

  • Kim, Yonghae;Whang, Dae-Sung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.3
    • /
    • pp.342-350
    • /
    • 2014
  • An active stimulating device, such as a fluttering net or canvas attached to the end of a cod end generating a shaking motion, could help to encourage the escape of juvenile fish positioned passively near the net. Field fishing trials using a shrimp beam trawl were carried out to examine the effect on the reduction of juvenile fish or other discard catch by generating a shaking movement of the cod end using an unbiased cap-like round canvas. The mean period of the shaking motion with the round canvas was ~14 s, and the mean amplitude was 0.4 m as measured by peak event analysis and the global wavelet method. The bycatch of juvenile fish in 14 trials decreased by ~30% and by ~25% using a steady cod end for the total bycatch using a shaking cod end in the shrimp beam trawl, while the marketing catch was similar between steady and shaking cod ends. There was no difference in the body size of the shrimp or fish and species composition between the steady and shaking cod ends. Above results demonstrate a new method for bycatch reduction using an active stimulating device, although more detailed studies are needed.

Design and Implementation of Continuous Control for Household Electric Fan Speed for Virtual Reality Applications

  • Jonas John, Claud;Dae-Young, Na;Daseong, Han
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.4
    • /
    • pp.518-528
    • /
    • 2022
  • Virtual Reality (VR) has been widely used in various applications to generate realistic virtual environments. A sense of immersion can be increased by providing additional stimuli such as tactile sensation to VR contents. However, it is still challenging to provide a realistic feel for the wind blowing over the whole body by smoothly controlling the airflow. To address this issue, we employ a household electric fan as a wind generating device to provide users with wind experience in VR environments. The wind generating device targets the whole body to mimic the wind we feel outside in our daily life. To do so, we present a low-cost method to smoothly control household fan speed using an Arduino microcontroller. Here, we use the Sinusoidal Pulse Width Modulation (SPWM) technique to generate the sinusoidal voltage required to drive the fan motor. Our experimental results show how Variable Voltage Variable Frequency (VVVF) is implemented at a low cost using our method for household fan speed control. The results can be applied to various VR applications to enhance the sense of immersion by providing users with realistic wind.

Applying Rosen-type PZT plasma generation device for medical applications (로젠형 압전변압기를 적용한 의료융합 플라즈마기기)

  • Lee, Kang-yeon;Jung, Byung-Geun;Park, Jeong-sook;Park, Ju-Hoon;Jeong, Byeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.1
    • /
    • pp.243-250
    • /
    • 2021
  • In the medical field, applications of plasma are applied sterilize instruments mainly but with the advent of bio-plasma technology, the scope of application is expanding. Recently, In addition, high-density miniaturization with handheld is required for sophisticated procedures when irradiated directly or treated with non-standard conditions. Rosen-type PZT is a device with a structure that generates high voltage plasma by achieving voltage transformation through electro-mechanical coupling using piezoelectric effect.and is used in portable plasma generating devices as an advantage to increase energy density relatively. In this paper, Rosen-type PZT was modeled using equivalent circuits and was carried out and a plasma generating device for medical application was designed and prototype tested. Prototype plasma generating device generates an output voltage of 5.8 kV with 12V input power and is designed to operate at high voltage by applying the half-bridge topology power converter. The results of the study confirmed the availability of various medical devices, such as plasma jets or direct exposure equipment.

Optimized Design of a Planar Haptic Device Using Passive Actuators

  • Kim, Tae-Woo;Cho, Chang-Hyun;Kim, Mun-Sang;Song, Jae-Bok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1565-1570
    • /
    • 2003
  • Passive Haptic Devices have more benefit than the active in Stability. But Apart from benefits, it shows poor performance in haptic display. The author proposed the passive FME(Force Manipulability Ellipsoid) which can graphically show force generating ability of a passive haptic device. In this paper, performance indexes for the force approximation and pseudo friction cone are obtained with the passive FME and an optimized planar device with the indexes is proposed. Based on the above theory, experiment is conducted.

  • PDF

Display Panel for AMOLED with 64 x 64 Pixels on 2' Plastic Substrate

  • Song, Chung-Kun;Ryu, Gi-Seong;Choe, Ki-Beom
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.356-358
    • /
    • 2004
  • In this paper we fabricated and succeeded to demonstrate a test panel for AMOLED on 2" glass and PET substrate. The test panel consisted of an array of 64 x 64 pixels in which OLEDs was driven by pentacene TFT. OTFTs were made of the inverted staggered structure and employed polyvinylphenol as the gate insulator and pentacene thin film as the active layer, producing the filed effect mobility of 0.3$cm^2$/V.sec and on/off current ratio of $10^5$. OLEDs were composed of TPD for HTL and Alq3 for EML with 35nm thick each, generating green monochrome light.

  • PDF

Implementation of A Spatial 3-DOF Haptic Mechanism (공간형 3 자유도 Haptic 메커니즘의 구현)

  • 이재훈;이수강;이병주;이석희;이정헌;김희국
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.312-316
    • /
    • 2004
  • In this study, a spatial 3-dof haptic mechanism is implemented. The implemented mechanism does not employ the gear transmissions as velocity reducers for all three joints but uses wire-based transmissions, thereby it is able to minimize the frictions significantly. Also, by employing the structure of the four-bar mechanism to drive third joint from close to the base, the mechanism is able to minimize the inertia effect from the third actuator very effectively. Its kinematic analysis such as position and velocity analyses are performed first. Then, its operating software development, hardware implementation, and the related interfaces between a PC and the implemented Haptic device are completed. To evaluate its potential and its performance as a haptic device, a experiment generating a virtual constraint in a operational task space is conducted and preliminary results are discussed.

  • PDF

Development of Electro-Mechanical Ignition Safety Device (전기-기계식 점화안전장치 개발)

  • Jang, Seung-Gyo;Kang, Ho-Joon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.332-335
    • /
    • 2011
  • Electro-Mechanical Ignition Safety Device(EMISD) for solid rocket motor is designed and manufactured. The EMISD utilizes a true rotary solenoid for arming mechanism and an electric squib(initiator) for generating ignition energy. In order to prove the ignition capability of the EMISD, 10-cc Closed Bomb Test(CBT) is performed, which measures the pressure built by high temperature and high pressure gas generated by operating EMISD.

  • PDF

Fabrication of Test Panel for AMOLED driven by Pentacene TFTs

  • Ryu, Gi-Seong;Byun, Hyun-Sook;Xu, Yong-Xian;Choe, Ki-Beom;Song, Chung-Kun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1034-1037
    • /
    • 2004
  • In this paper we fabricated a test panel for AMOLED on glass and PET substrate. The test panel consisted of the various size of OTFTs and OLEDs and the current driving capability of OTFTs for OLEDs has been investigated. OTFTs were made of the inverted staggered structure and employed polyvinylphenol (PVP) as the gate insulator and pentacene thin film as the active layer. The OTFTs produced the filed effect mobility of 0.3$cm^2$/V.sec and on/off current ratio of $10^5$. OLEDs consisted of TPD for HTL and Alq3 for EML with 35nm thick, generating green monochrome light. We found that OTFT with channel length of 70${\mu}m$and channel width of over 3.5mm provided the sufficient current to OLED to generate the luminescence of 0.3Cd/$m^2$.

  • PDF

Development of the Microfluidic Device to Regulate Shear Stress Gradients

  • Kim, Tae Hyeon;Lee, Jong Min;Ahrberg, Christian D.;Chung, Bong Geun
    • BioChip Journal
    • /
    • v.12 no.4
    • /
    • pp.294-303
    • /
    • 2018
  • Shear stress occurs in flowing liquids, especially at the interface of a flowing liquid and a stationary solid phase. Thus, it occurs inside the artery system of the human body, where it is responsible for a number of biological functions. The shear stress level generally remains less than $70dyne/cm^2$ in the whole circulatory system, but in the stenotic arteries, which are constricted by 95%, a shear stress greater than $1,000dyne/cm^2$ can be reached. Methods of researching the effects of shear stress on cells are of large interest to understand these processes. Here, we show the development of a microfluidic device for generating shear stress gradients. The performance of the shear stress gradient generator was theoretically simulated prior to experiments. Through simple manipulations of the liquid flow, the shape and magnitude of the shear stress gradients can be manipulated. Our microfluidic device consisted of five portions divided by arrays of micropillars. The generated shear stress gradient has five distinct levels at 8.38, 6.55, 4.42, 2.97, and $2.24dyne/cm^2$. Thereafter, an application of the microfluidic device was demonstrated testing the effect of shear stress on human umbilical vein endothelial cells.

Design of an Integrated Interface Circuit and Device Driver Generation System (인터페이스 회로와 디바이스 드라이버 통합 자동생성 시스템 설계)

  • Hwang, Sun-Young;Kim, Hyoun-Chul;Lee, Ser-Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.6B
    • /
    • pp.325-333
    • /
    • 2007
  • An OS requires the device driver to control hardware IPs at application level. Development of a device driver requires specific acknowledge for target hardware and OS. In this paper, we present a system which generates a device driver together with an interface circuit. In the proposed system, an efficient device driver is generated by selecting a basic device driver skeleton, a function module code, and a header file table from the pre-constructed library and an interface circuit is constructed such that the generated device driver operates correctly. The proposed system is evaluated by generating a TFT-LCD device driver on the ARM922T core with 3.5 inch Samsung TFT-LCD in ARM-Linux environment. Experiment result shows that the writing time on the LCD is decreased by 1.12% and the compiled code size is increased by 0.17% compared to the manually generated one. The automatically generated device driver has no performance degradation in the latency of hardware control at the application program level. The system development time can be reduced using the proposed device driver generation system.