• 제목/요약/키워드: Generating device

검색결과 325건 처리시간 0.034초

수력발전소 IED의 디지털 보호 알고리즘에 관한 연구 (A Study on Digital Protection Algorithm of IED for Hydroelectric Generating Unit)

  • 박철원
    • 전기학회논문지P
    • /
    • 제63권3호
    • /
    • pp.149-156
    • /
    • 2014
  • Generator of hydroelectric generating unit is to be protected by the digital protection IED. Now, any IED of large capacity for hydro power plant was not developed by domestic technology. This is because it is required for the generator of the high reliability technology and considered as due to the sale of the market of IED device is small. However, the protection IED must be develop by domestic technology to meet the advanced needs of the construction and replacement of electrical equipment in accordance with the new power plant development. In this paper, a digital algorithms for protection IED of large size of hydroelectric generating unit were designed. The algorithms consist of the stator protection, anti-motoring, overexcitation and loss of excitation. The performance of the algorithms were evaluated by using the simulation data collected from the PSCAD/EMTDC software. From test results, it can be seen that the developed algorithms were not maloperation.

플라즈마 발생장치용 공진형 인버터 전력변환장치 (A Resonant Type Inverter Power Conversion Equipment for Plasma Generator)

  • 김주용;서기영;문상필;정장근;김영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.162-165
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

오존 발생기용 공진형 인버터의 출력특성 (The output characteristics of resonant type inverter for ozone generator)

  • 강욱중;이현우;서기영;권순걸;문상필
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.139-142
    • /
    • 2002
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for Ozone Generator are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[kHz], 1.8[kW] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

플라즈마 살균용 전원장치에 관한 연구 (A study on power system for plasma sterilization)

  • 강욱중;김영문;문상필;권순걸;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.52-54
    • /
    • 2002
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described, For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc.. PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[kHz], 1.8[kW] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

플라즈마 살균 효과 개선을 위한 공진용 인버터 전원 시스템 (Resonance inverter power system for plasma sterilization effective improvement)

  • 김주용;문상필;김종실;김영문;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1172-1174
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

플라즈마 살균 효과 향상을 위한 공전형 전원 시스템 (Resonance Inverter Power System for Sterilization Effective Improvement of Plasma)

  • 김주용;문상필;정장근;이현우;서기영
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.397-401
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[㎑], 1.8[㎾] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

The Design of Fault Tolerant Dual System and Real Time Fault Detection for Countdown Time Generating System

  • Kim, Jeong-Seok;Han, Yoo-Soo
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권10호
    • /
    • pp.125-133
    • /
    • 2016
  • In this paper, we propose a real-time fault monitoring and dual system design of the countdown time-generating system, which is the main component of the mission control system. The countdown time-generating system produces a countdown signal that is distributed to mission control system devices. The stability of the countdown signal is essential for the main launch-related devices because they perform reserved functions based on the countdown time information received from the countdown time-generating system. Therefore, a reliable and fault-tolerant design is required for the countdown time-generating system. To ensure system reliability, component devices should be redundant and faults should be monitored in real time to manage the device changeover from Active mode to Standby mode upon fault detection. In addition, designing different methods for mode changeover based on fault classification is necessary for appropriate changeover. This study presents a real-time fault monitoring and changeover system, which is based on the dual system design of countdown time-generating devices, as well as experiment on real-time fault monitoring and changeover based on fault inputs.

수력발전기 자동동기투입 실패에 관한 고찰 (A Study on Auto synchronization failure of a Generator)

  • 전규남;장문성;이재훈;정재원;안주훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.268-269
    • /
    • 2006
  • Auto-synchonizer is important device to match the voltage, frequency, phase of the generating system to those factors of the transmission line, when the synchronous generator is operated. There were few or no incidents by Synchronization failure at Hapcheon hydraulic power plant, since it was built in 1989. but incidents by Synchronization failure have often happend lately. From now, let's improve the efficiency on the maintenance of generating equipment by studying about the cause and the method for this problem by comparing with the set point of each device of synchronizing system.

  • PDF

충격전류발생장치의 실험적연구 (Experimental Study of Impulsive High Current Generating Apparatus)

  • 김안균
    • 전기의세계
    • /
    • 제24권4호
    • /
    • pp.73-76
    • /
    • 1975
  • In this study, a design scheme of an impulsive high current generating device is presented. The device is proved to be effective in producing rather complex type of the permanent magnet. Principally, the apparatus designed same to the ordinary potential transformer or current transformer, but, it has a certain differences that the primary winding of many turns is excited by d.c. source and the secondary winding of a few turns induce low voltage and high current at the instant when opening a switch in the primary circuit. This paper does not include magnet production process. Rather, it deals with the analytical studies of the devices, the designing procedure of the experimental setup, and some results from the experimental data are presented as a preliminary study. The experimental results are found to agree well with the theoritical analysis presented in this paper.

  • PDF

후륜 캠버각 변화가 차량 조종성능에 미치는 효과 분석 (Analysis of Vehicle Handling Performance due to Camber Angle Change of Rear Wheel)

  • 박성준;손정현
    • 한국자동차공학회논문집
    • /
    • 제18권2호
    • /
    • pp.67-73
    • /
    • 2010
  • In this study, a camber angle generating mechanism for rear suspension is suggested. An experimental device is implemented and tested. A full vehicle model with camber angle generating device by using ADAMS/Car is modeled. Rear left wheel and rear right wheel have 5 different camber angles in the simulations, respectively. Step steer and pulse steer simulations are carried out for investigating the effects of vehicle handling performance due to camber angle control of rear suspension. According to the results, the camber angle of rear suspension affects the vehicle handling performance during both simulations. Therefore, when the vehicle makes the right turn or left turn, left and right wheel should have the proper orientation for improving the handling performance, respectively.