• Title/Summary/Keyword: Generated power

Search Result 3,483, Processing Time 0.036 seconds

Numerical Investigation of Cooling Performance of Liquid-cooled Battery in Electric Vehicles (하이브리드/전기 자동차용 수냉식 배터리 셀의 냉각성능에 관한 수치 해석적 연구)

  • Kwon, Hwabhin;Park, Heesung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.6
    • /
    • pp.403-408
    • /
    • 2016
  • Lithium-ion batteries are commonly employed in hybrid electric vehicles (HEVs), and achieving high energy density in the battery has been one of the most critical issues in the automotive industry. Because liquid cooling containing antifreeze is important in automotive batteries to enable cold starts, an effective geometric configuration for high-cooling performance should be carefully investigated. Battery cooling with antifreeze has also been considered to realize successful cold starts. In this article, we theoretically investigate a specific property of an antifreeze cooling battery system, and we perform numerical modeling to satisfy the required thermal specifications. Because a typical battery system in HEVs consists of multiple stacked battery cells, the cooling performance is determined mainly by the special properties of antifreeze in the coolant passage, which dissipates heat generated from the battery cells. We propose that the required cooling performance can be realized by performing numerical simulations of different geometric configurations for battery cooling. Furthermore, we perform a theoretical analysis as a design guideline to optimize the cooling performance with minimum power consumption by the cooling pump.

A Study on the PEM Electrolysis Characteristics Using Ti Mesh Coated with Electrocatalysts (Ti Mesh 처리 촉매전극을 이용한 고체고분자 전해질 전기분해 특성연구)

  • Sim, Kyu-Sung;Kim, Youn-Soon;Kim, Jong-Won;Han, Sang-Do
    • Journal of Hydrogen and New Energy
    • /
    • v.7 no.1
    • /
    • pp.29-37
    • /
    • 1996
  • Alkaline water electrolysis has been commercialized as the only large-scale method for a long time to produce hydrogen and the technology is superior to other methods such as photochemical, thermochemical water splitting, and thermal decomposition method in view of efficiency and related technical problem. However, such conventional electrolyzer do not have high electric efficiency and productivity to apply to large scale hydrogen production for energy or chemical feedstocks. Solid polymer electrolyte water electrolysis using a perfluorocation exchange membrane as an $H^+$ ion conductor is considered to be a promising method, because of capability for operating at high current densities and low cell voltages. So, this is a good technology for the storage of electricity generated by photovoltaic power plants, wind generators and other energy conversion systems. One of the most important R&D topics in electrolyser is how to minimize cell voltage and maximize current density in order to increase the productivity of the electrolyzer. A commercialized technology is the hot press method which the film type electrocatalyst is hot-pressed to soild polymer membrane in order to eliminate the contact resistance. Various technologies, electrocatalyst formed over Nafion membrane surface by means of nonelectrolytic plating process, porous sintered metal(titanium powder) or titanium mesh coated with electrocatalyst, have been studied for preparation of membrane-electrocatalyst composites. In this study some experiments have been conducted at a solid polymer electrolyte water electrolyzer, which consisted of single cell stack with an electrode area of $25cm^2$ in a unipolar arrangement using titanium mesh coated with electrocatalyst.

  • PDF

Development of the Integrated Fuel Cell Monitoring System (통합 연료전지모니터링 시스템 개발)

  • KIM, HYUNJUN;YEOM, SANGCHUL;AHN, BYUNGKI;KIM, SAEHOON;KUM, YEONGBEOM
    • Journal of Hydrogen and New Energy
    • /
    • v.26 no.3
    • /
    • pp.241-246
    • /
    • 2015
  • The interest of New Renewable Energy is increasing globally because of the increment of the uncertainty for the energy's supply and demand, and the increment of the frequency in weather anomaly and its damages. One of the New Renewable Energies, Hydrogen receives attention as the future energy that can deal with global environment regulation. Fuel Cell Electric Vehicle (FCEV) is an environment-friendly vehicle that uses Hydrogen as fuel. The electric power for FCEV is generated by chemical reaction with Oxygen from the air and Hydrogen. Hyundai Motor Company (HMC) has developed a proprietary fuel cell system since 2005. In 2012, HMC is the first car maker that mass-produces the ix35 FCEV to the worldwide such as North America, Europe, etc. In order to develop and improve the FCEV technology, data acquisition and analysis of the driving vehicle information is essential. Therefore, the monitoring system is developed, which is consist of datalogger, Automatic Vehicle Location (AVL) server and main server. Especially, WCDMA technology is integrated into the system which enables the data analysis without any restriction of time and region. The main function of the system is the analysis of the driving pattern and the component durability, and the safety monitoring. As a result, ix35 FCEV has successfully developed by using the developed monitoring system. The system is going to take an advantage of development in the future FCEV technology.

Calculation of Low-Energy Reactor Neutrino Spectra for Reactor Neutrino Experiments

  • Riyana, Eka Sapta;Suda, Shoya;Ishibashi, Kenji;Matsuura, Hideaki;Katakura, Jun-ichi
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.155-159
    • /
    • 2016
  • Background: Nuclear reactors produce a great number of antielectron neutrinos mainly from beta-decay chains of fission products. Such neutrinos have energies mostly in MeV range. We are interested in neutrinos in a region of keV, since they may take part in special weak interactions. We calculate reactor antineutrino spectra especially in the low energy region. In this work we present neutrino spectrum from a typical pressurized water reactor (PWR) reactor core. Materials and Methods: To calculate neutrino spectra, we need information about all generated nuclides that emit neutrinos. They are mainly fission fragments, reaction products and trans-uranium nuclides that undergo negative beta decay. Information in relation to trans-uranium nuclide compositions and its evolution in time (burn-up process) were provided by a reactor code MVP-BURN. We used typical PWR parameter input for MVP-BURN code and assumed the reactor to be operated continuously for 1 year (12 months) in a steady thermal power (3.4 GWth). The PWR has three fuel compositions of 2.0, 3.5 and 4.1 wt% $^{235}U$ contents. For preliminary calculation we adopted a standard burn-up chain model provided by MVP-BURN. The chain model treated 21 heavy nuclides and 50 fission products. The MVB-BURN code utilized JENDL 3.3 as nuclear data library. Results and Discussion: We confirm that the antielectron neutrino flux in the low energy region increases with burn-up of nuclear fuel. The antielectron-neutrino spectrum in low energy region is influenced by beta emitter nuclides with low Q value in beta decay (e.g. $^{241}Pu$) which is influenced by burp-up level: Low energy antielectron-neutrino spectra or emission rates increase when beta emitters with low Q value in beta decay accumulate Conclusion: Our result shows the flux of low energy reactor neutrinos increases with burn-up of nuclear fuel.

Radioactive Wastes Vitrification Using Induction Cold Crucible Melter: Characteristics of Vitrified Form (유도 가열식 저온용융로를 이용한 방사성페기물 유리화: 유리 고화체 특성)

  • 김천우;박은정;최종락;지평국;최관식;맹성준;박종길;신상운;송명재
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.6
    • /
    • pp.576-581
    • /
    • 2002
  • In order to simultaneously vitrify the ton Exchange Resin(IER) and Dry Active Waste(DAW) generated from the Nuclear Power Plants, a vitrification pilot test was conducted using an induction cold crucible melter. The PCT result evaluating the chemical durability of the vitrified from showed that the final glass was more durable than the benchmark glass. Liquidus temperature for the final vitrified form was 1048 K(775$\^{C}$) fur heat treatment experiments. The value of the compressive strength for the vitrified form was ninety times higher than the regulation limit, 34 kg/㎠. The glasses on bottom, middle and top of the CCM were homogeneous with no secondary phase. The precipitation of the magnetic metal phase was able to be avoided by simultaneously fEeding of DAW with IER containing strongly reducing organics. Volume reduction factor of 74 was achieved through the vitrification Pilot test for mixed waste.

Evaluation of PTO Severeness for 78 kW-Class Tractor According to Disk Plow Tillage and Rotary Tillage (디스크플라우 및 로타리 작업에 따른 78 kW급 트랙터 PTO 가혹도 평가)

  • Kim, Wan Soo;Kim, Yong Joo;Park, Seong Un;Hong, Soon Jung;Kim, Yeon Soo
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.23-31
    • /
    • 2019
  • The purpose of this study was to evaluate the PTO severeness for an agricultural tractor during disk plow and rotary tillage. The PTO load measurement system was constructed with data acquisition and a PTO torquemeter. Field experiments were conducted at a combination of traveling speed (L3 Low, L3 High) and PTO speed (P1, P2). The load spectrum was generated using the rain-flow counting method, and the SWT method was used to consider the range and mean of the PTO load. The damage sum was calculated by applying a modified miner rule, which is a cumulative damage law. The relative severeness was expressed as the ratio of the lowest damage sum. Relative severeness was higher with the lower PTO gear stage, and higher driving gear stage and it was approximately 40-102 times higher for rotary tillage than disk plow tillage in the same gear stages. The relative severeness was 1010.12 in the rotary tillage under L3 High P1 based on the disk plow tillage under L3 Low P2.

The study of geopolymer utilization of reclaimed ash by using magnetic separation method (자력선별법을 이용한 화력 발전소 매립회의 지오폴리머 원료화 연구)

  • Kim, Kangduk
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.5
    • /
    • pp.249-255
    • /
    • 2017
  • Using a magnetic separation process, pond ash generated in thermoelectric power plants was separated into magnetic materials and nonmagnetic materials in order to make it into a raw material of geopolymers and unburned carbon; screening characteristics according to the particle sizes and magnet strength levels of the pond ash were observed. Based on the results of magnetic separation into fine particle (0.15~0.84 mm) and rough particle (0.84~2.4 mm) pond ash using 3000 G magnets, the weight fraction and ignition loss of nonmagnetic materials were found to be higher than those of magnetic materials, regardless of the particle size. In the case of fine particle pond ash, when the magnet strength was increased from 3000 G to 10000 G, even those materials that were weakly magnetic were separated into magnetic materials, leading to drastic increases in the weight fraction of magnetic materials, such that the ignition loss accounted for 66.9 % (22.8 wt%) of the entire ignition loss of 32.6 wt%, despite of the low ignition loss. Based on the results of measurement of the compressive strength levels of geopolymers made of magnetic-separated rough particle pond ash, the compressive strength of geopolymers made of magnetic materials containing small amounts of unburned carbon was found to be 20 MPa.

Selection of Detection Measures using Relative Entropy based on Network Connections (상대 복잡도를 이용한 네트워크 연결기반의 탐지척도 선정)

  • Mun Gil-Jong;Kim Yong-Min;Kim Dongkook;Noh Bong-Nam
    • The KIPS Transactions:PartC
    • /
    • v.12C no.7 s.103
    • /
    • pp.1007-1014
    • /
    • 2005
  • A generation of rules or patterns for detecting attacks from network is very difficult. Detection rules and patterns are usually generated by Expert's experiences that consume many man-power, management expense, time and so on. This paper proposes statistical methods that effectively detect intrusion and attacks without expert's experiences. The methods are to select useful measures in measures of network connection(session) and to detect attacks. We extracted the network session data of normal and each attack, and selected useful measures for detecting attacks using relative entropy. And we made probability patterns, and detected attacks using likelihood ratio testing. The detecting method controled detection rate and false positive rate using threshold. We evaluated the performance of the proposed method using KDD CUP 99 Data set. This paper shows the results that are to compare the proposed method and detection rules of decision tree algorithm. So we can know that the proposed methods are useful for detecting Intrusion and attacks.

A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring (온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구)

  • Kim, Jung-Yul;Kim, Yoo-Sung;Song, Yoon-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1100-1109
    • /
    • 2006
  • In this study, two different technologies which can measure temperature simultaneously at many points are introduced. One is to use a thermal sensor cable that is comprised of addressable thermal sensors connected in parallel within a single cable. The other is to use an optic fiber with Distributed Temperature Sensing (DTS) system. The difference between two technologies can be summarized as follows. A thermal sensor cable has a concept of 'point sensing' that can measure temperature at accurate position of a thermal sensor. So the accuracy and resolution of temperature measurement are up to the ability of the thermal sensor. Whereas optic fiber sensor has a concept of 'distributed sensing' because temperature is measured by ratio of Stokes and anti-Stokes component intensities of Raman backscatter that is generated when laser pulse travels along an optic fiber. It's resolution is determined by measuring distance, measuring time and spatial resolution. The purpose of this study is that application targets of two temperature measurement techniques are checked in technical and economical phases by examining the strength and weakness of them. Considering the functions and characteristics of two techniques, the thermal sensor cable will be suitable to apply to the assessment of groundwater flow, geothermal distribution and grouting efficiency within 300m distance. It is expected that the optic fiber sensor can be widely utilized at various fields (for example: pipe line inspection, tunnel fire detection, power line monitoring etc.) which need an information of temperature distribution over relatively long distance.

  • PDF

Improvement Method of Regional Insulation Standard through the Regional Heating Energy Demand Analysis (권역별 난방에너지 요구량 분석을 통한 단열기준 개선방안)

  • Kim, Jeong-Gook;Ahn, Byung-Lip;Jang, Cheol-Yong;Jeong, Hak-Geun;Haan, Chan-Hoon
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.43-48
    • /
    • 2013
  • The effect of climate change has influenced humanity and ecosystem with tremendous changes in temperature. For the past 150 years, the national annual average temperature is 0.6 degree increased and the heating degree day reduced from April to November. However, December to January, the climate change was generated and the heating degree day increased. The blackout occured in 2011 and 2012 by increasing electricity consumption of heating and cooling equipment to the effects of climate change. That is because heating load accounted for 20% of building electric use. In this study, strengthening measures to reduce heating energy consumption is presented due to climate change in winter since 1980 to prevent blackout and reliable power supply for the building energy-saving design standards by Meteorological data provided by the National Weather Service were calculated using the heating degree days in order to present eighteen cities from 1980 to 2012. Insulation standards are presented to prevent black-out by the heating degree days. the heating energy demand was reduced almost 6% including 10% in Central, 5% in South and Jeju area based on strengthening of the insulation. It is applied to the entire country an annual economic effect of 250 billion won, and black-out can be prevented.