• Title/Summary/Keyword: Generated load

Search Result 1,305, Processing Time 0.028 seconds

A Study on the Vibration Isolation Design of Road Passing through Building (건물을 통과하는 도로의 방진설계 연구)

  • 맹주원;권태철;이성춘;홍갑표
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.760-765
    • /
    • 2003
  • This study is performed in order to determine a method to solve vibration-borne problems by isolating the vibration that is generated by vehicles in case a road passes through a building and also to verify its applicability and effect both theoretically and experimentally.

  • PDF

Power Control & Distribution Unit Development for Bus Power Control of Communication Satellite with Large Capacity (대용량 통신위성 전력조절을 위한 전력제어장치개발)

  • Choi Jaedong
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.85-89
    • /
    • 2004
  • This paper presents Power Control and Distribution Unit development of GEO satellite with 3kW power output. The sensing error of bus voltage produce control signal of the shunt switch assembly and battery power converter, and the tolerance of error signals generated decide the stability of proposed system. The dynamic characteristics of main bus according to the load changing and the control logic of FPGA are simulated. In order to verify the proposed design, the simulation and experimental results for solar array shunt switch, battery power converter and bus controller are shown.

  • PDF

Development of An Active Magnetic Bearing-based Motor-Generator System (자기베어링 지지 모터-발전기 시스템 개발)

  • Kim, Jong-Moon;Kim, Choon-Kyung;Kim, Kook-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.127-129
    • /
    • 1997
  • In this paper, an active magnetic bearing-based motor-generator(M-G) system is designed and controlled by using DSP devices. Several experiments including start-up test, impulse test, whirl test, and generator load test are conducted using digital PID algorithm and AC power of about 58Hz, 100V, 0.8A can be generated from the M-G set.

  • PDF

Investigation of Tieback wall Behavior based on Generated Mass Movement (Mass Movement가 타이백 앵커 벽체의 거동에 미치는 영향평가)

  • 임유진
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.5
    • /
    • pp.83-92
    • /
    • 2000
  • 벽체의 수평변위 중 토체의 침하 및 앵커체 자체의 움직임 등으로 인해 발생하는 mass movement가 타이백 앵커토류벽의 거동에 미치는 영향을 조사하였다. 시공사례에 대한 유한요소 해석을 실시하여 벽체의 변위, 겉보기토압, mass movement 및 앵커 자유장 내에서의 하중 변화를 투적하였다. 유한요소해석법을 이용해 mass movement를 계산, 예측할 수 있었으며, 시공 순서에 따흔 앵커 자유장 내의 하중변화를 예측할수 있었다. 현장계측결과와 유한요소해석결과로부터 벽체변위, 겉보기토압 및 앵커의 하중 변화에 미치는 mass movement의 영향이 매우 큼을 확인 할 수 있었다.

  • PDF

New Layout Design Concept for Suppressing the Substrate Current in CMOS Inverter (CMOS Inverter의 Substrate Current를 줄이는 Layout 설계)

  • Park, Heung-Joon;Kim, Choong-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.407-410
    • /
    • 1987
  • A layout design concept which suppress the substrate current generated during the switching transients of an CMOS inverter is presented. The amount of hot carriers and the peak value of substrate current can be reduced by changing the device geometry ratio of driver and load device of an CMOS inverter.

  • PDF

Effect of conductor temperature rise generated by load current on the cable life (운전전류에 의한 도체온도 상승이 케이블 수명에 미치는 영향)

  • Yun, Jea-Hun;Lim, Seong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1445-1447
    • /
    • 2003
  • 산업공장에서 저압케이블이 지중에 집중 매설되어 있는 경우 운전전류에 의한 케이블 도체온도가 도체허용온도를 초과할 수 있다. 또한 절연재질의 활성화 에너지와 환경온도로 표현되는 아레니우스 모델의 환경온도 대신 운전전류에 의해 계산된 도체온도를 사용하여 케이블의 수명을 예측하여 보았다.

  • PDF

Operating Mode of Thermally Activated Building System (TABS) for Residential Buildings According to their Cooling Load Profile (주거건물의 냉방 부하 패턴에 따른 구체축열시스템 운전 방안)

  • Park, Sang-Hoon;Yeo, Myoung-Souk;Yoo, Mi-Hye;Lee, Yu-Ji;Chung, Woong-June;Kim, Kwang-Woo
    • Journal of the Korean housing association
    • /
    • v.23 no.2
    • /
    • pp.99-106
    • /
    • 2012
  • Compared to Packaged Terminal Air Conditioning Systems, Radiant Cooling Systems have the advantage of energy saving and thermal comfort. Thermally Activated Building System (TABS) is one of the radiant heating and cooling systems. The main difference between TABS and other radiant systems lies in the usage of the time-lag effect of storing heat energy in the concrete. Current energy usage in summer time is concentrated within a specific time by using Packaged Terminal Air-Conditioner (PTAC). Due to the time-lag effect of TABS, energy usage can be distributed to other time zones. To maximize this effect, it is important to determine the appropriate operating mode, which for TABS is dependent upon the cooling load generated by the occupancy schedule. In this study, occupancy schedules are determined for various residential types. The operating modes of TABS for these residential types are estimated by using a dynamic computational simulation method. The results indicate that the operating modes of TABS can be determined by residential type and occupancy schedule. The load handled ratio by TABS is set up differently according to the cooling load profile obtained from residential type and occupancy schedule. By using TABS, energy consumption could be reduced by 20% compared to PTAC.

A Reconfigurable Load and Performance Balancing Scheme for Parallel Loops in a Clustered Computing Environment (클러스터 컴퓨팅 환경에서 병렬루프 처리를 위한 재구성 가능한 부하 및 성능 균형 방법)

  • 김태형
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.10 no.1
    • /
    • pp.49-56
    • /
    • 2004
  • Load imbalance is a serious impediment to achieving good performance in parallel processing. Global load balancing schemes cannot adequately manage to balance parallel tasks generated from a single application. Dynamic loop scheduling methods are known to be useful in balancing parallel loops on shared-memory multiprocessor machines. However, their centralized nature causes a bottleneck for the relatively small number of processors in a network of workstations because of order-of-magniture differences in communication overheads. Moreover, improvements of basis loops scheduling methods have not effectively dealt with irregularly distributed workloads in parallel loops, which commonly occur in applications for a network of workstation. In this paper, we present a new reconfigurable and decentralized balancing method for parallel loops on a network of workstations. Since our method supplements performance balancing with those tranditional load balancing methods, it minimizes the overall execution time.

The Reaction Characteristics of NOx/N2O and NH3 in Crematory Facility SCR Process with Load Variation (부하변동이 큰 화장시설 SCR 공정에서 NOx/N2O 및 NH3 동시 저감 특성 연구)

  • Park, Poong Mo;Lee, Ha Young;Yeo, Sang-Gu;Yoon, Jae-Rang;Dong, Jong In
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.605-615
    • /
    • 2017
  • Efficient simultaneous reduction conditions for $NO_x$ and $NH_3$-slip was investigated in SCR (Selective Catalytic Reduction) process with load variation by applying dual catalysts (SCR catalyst, $NH_3$ decomposition catalyst) system. $N_2O$ formation characteristics were analyzed to look into possible undesirable reaction pathways. In the experiments of catalyst characteristics, various operational variables were tested for the combined catalytic system, such as $NH_3/NO_x$ ratio, temperature, oxygen concentration and $H_2O$. The reaction characteristics of $NO_x$, $NH_3$ and $N_2O$ were analyzed and optimal conditions could be evaluated for the combustion facility with varied load. In terms of $NO_x/NH_3$ simultaneous reduction and $N_2O$ formation suppression, optimal condition was considered NSR 1.2 and temperature $300^{\circ}C$. At this operational condition, $NO_x$ conversion was 98%, $NH_3$ reduction efficiency was 95%, generated $N_2O$ concentration 9.5 ppm with inlet $NO_x$ concentration of 100 ppm. In $NH_3-SCR$ process with $NH_3$ decomposition catalyst, $NO_x$ and $NH_3$ can be considered to be reduced simultaneously at limited conditions. The results of this study may be utilized as basic data at facilities requiring simultaneous $NO_x$ and $NH_3$ reduction for facilities with load variation.

The Effects of Ramp Gradients and Pushing-Pulling Techniques on Lumbar Spinal Load in Healthy Workers

  • Pinupong, Chalearmpong;Jalayondeja, Wattana;Mekhora, Keerin;Bhuanantanondh, Petcharatana;Jalayondeja, Chutima
    • Safety and Health at Work
    • /
    • v.11 no.3
    • /
    • pp.307-313
    • /
    • 2020
  • Background: Many tasks in industrial and health care setting are involved with pushing and pulling tasks up or down on a ramp. An efficient method of moving cart which reduces the risk of low back pain should be concerned. This study aimed to investigate the effects of handling types (HTs) and slope on lumbar spinal load during moving a cart on a ramp. We conducted a 2 × 2 × 4 factorial design with three main factors: 2 HTs, 2 handling directions of moving a cart and 4 degrees of ramp slope. Methods: Thirty healthy male workers performed 14 tasks consist of moving a cart up and down on the ramp of 0°, 10°, 15°, and 20° degrees with pushing and pulling methods. Joint angles from a 3D motion capture system combined with subject height, body weight, and hand forces were used to calculate the spinal load by the 3DSSPP program. Results: Our results showed significant effect of HT, handling directions and slope on compression and shear force of the lumbar spine (p < 0.001). When the ramp gradient increased, the L4/5 compression forces increased in both pushing and pulling (p < 0.001) Shear forces increased in pulling and decreased in pushing in all tasks. At high slopes, pulling generated more compression and shear forces than that of pushing (p < 0.01). Conclusion: Using the appropriate technique of moving a cart on the ramp can reduce the risk of high spinal load, and the pushing is therefore recommended for moving a cart up/down on ramp gradients.