• Title/Summary/Keyword: Generated Electricity

Search Result 277, Processing Time 0.023 seconds

Economic analysis of hydrogen production technology using water electrolysis (물의 전기분해에 의한 수소 제조기술과 경제성 분석)

  • Sim, Kyu-Sung;Kim, Chang-Hee;Park, Kee-Bae
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.15 no.4
    • /
    • pp.324-332
    • /
    • 2004
  • According to the rapid depletion of the fossil fuels, the electricity and hydrogen will gradually take charge of the future energy supply. Especially, in order to control the supply and demand of electricity, energy storage medium is necessary and this could be solved by the combination of water electrolysis and fuel cell. Although electricity can be generated from such alternative energies as hydropower, nuclear, solar, and wind-power resources, alternative energy storage medium is also required since regenerative energies, solar and wind-powers, are intermittent energy resources. In this regard, hydrogen production from water electrolysis was recognized as a superb method for electricity storage. In this work, the current development and economic status of alkaline, solid polymer, and high temperature electrolysis were reviewed, and then the practical use of water electrolysis technology were discussed.

Electricity Generation from Volatile Fatty Acids (VFAs) Using a Microbial Fuel Cell (휘발성지방산으로부터 미생물연료전지에 의한 전기 생산)

  • Oh, S.E.;Kim, S.J.;Yang, J.E.;Jung, Y.S.
    • Korean Journal of Environmental Agriculture
    • /
    • v.26 no.2
    • /
    • pp.179-185
    • /
    • 2007
  • A new technology that utilizes a microbial fuel cell (MFC) has been developed to generate electricity directly from the oxidation of organic matters such as carbohydrates or complex organics in wastewater. Fermentation of these organic matters results in production of volatile fatty acids (VFAs), alcohols, $CO_2$ and $H_2$. We investigated the electricity-producing potential of the VFAs and actual food processing wastewater using a two-chambered MFC. The electrons produced by acetate degradation were proportional to acetate concentration in the medium. Acetate concentration and generated power were linearly correlated at a low range or acetate concentration (< 8 mg/L), but at above 8 mg/L of acetate the power produced was maintained at 0.1 mW. When butyrate was added to the anode acclimated to acetate, there was a lag period of 30 hr for electricity generation. However, when propionate was added to the same anode bottle, lag periods were not existed. The wastewater from baby food processing generated the maximum power density of $81{\pm}7\;mW/m^2$ of electricity and exhibited the Coulombic efficiencies of 27.1% and 40.5% based on TCOD and SCOD, respectively. Sugars in the food processing wastewater were reduced within 50 h from 230 mg/L < 30 mg/L.

Development of Functional Pulp Tray for Prevention of Static Electricity (정전기 방지를 위한 기능성 펄프 트레이 개발)

  • Lee, Ji-Young;Kim, Chul-Hwan;Nam, Hye-Gyeong;Park, Hyeong-Hun;Kwon, Sol;Lee, Young-Min
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.5
    • /
    • pp.52-60
    • /
    • 2015
  • Static electricity is an imbalance of electric charges within or on the surface of a material. All packed items that are particularly sensitive to static discharge must be protected by antistatic treatment. Otherwise, static electricity generated by an electrical insulator may cause serious damages to some sensitive electronics. In order to remove or prevent a buildup of static electricity, packed items must be treated with the application of an antistatic agent, which helps any excess charge to be evenly distributed. Functional pulp tray used for packing of electronic goods was developed with application of an antistatic agent. As the concentration of the antistatic agent increased, charging voltage and surface resistance of molded pulps decreased. The increase of humidity in surrounding atmosphere around molded pulps led to the decrease of accumulation of static charges. In conclusion, the surface treatment of the antistatic agent not only reduced or eliminated buildup of static electricity in the surface, but also prevented generation of tiny dirts from molded tray.

The Performance and Energy Saving Effect of a 2kWp Roof-Integrated Photovoltaic System (주택지붕용 2kWp BIPV시스템의 성능 실험 및 전기 부하 감당에 관한 연구)

  • Lee, Kang-Rock;Oh, Myung-Tack;Park, Kyung-Eun;Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • The efficiency of building-integrated photovoltaic(BIPV) system is mainly determined by solar radiation and the temperature of PV modules. The performance of BIPV systems is reported to be different from that of conventional PV systems installed in the open-air. This paper presents the relationship of solar radiation and electricity generation from a 2kWp roof-integrated PV system that is applied as building elements on an experimental house, and the energy saving effect of the BIPV system for a typical house. For the performance evaluation of the BIPV system, it produced a regression equation with measured data for winter days. The regression equation showed that a comparison of the measured electricity generation and the predicted electricity generation of the BIPV system were meaningful. It showed that an annual electricity generation of the system appeared to cover around 52% of an annual electricity consumption of a typical domestic house with the floor area of $96m^2$.

Analysis of Determinants of Electricity Import and Export in Europe Using Spatial Econometrics (공간계량 방법론을 활용한 유럽의 전력수출입 결정요인 분석)

  • Hong, Won Jun;Lee, Jihoon;Noh, Jooman;Cho, Hong Chong
    • Environmental and Resource Economics Review
    • /
    • v.30 no.3
    • /
    • pp.435-469
    • /
    • 2021
  • The main purpose of this study is to identify the determinants of electricity import and export in 26 European Union countries using the Spatial durbin model(SDM). In particular, we would like to mainly explain it based on the amount of power generated by each energy source. Not just the usual way of constructing a weighting matrix based on contiguity, we adopt a weighting method based on the proportion of trade among countries with connected electricity systems. Moreover, the electricity systems of European countries are directly and indirectly connected, which is reflected in the weighting matrix. According to the results, nuclear power has a positive effect on exports and a negative effect on imports, and an increase in wind and solar power has a positive effect on both exports and imports by increasing power system instability. While Korea is unable to trade electricity due to geopolitical conditions, the results of this study are expected to provide implications for energy policies.

A Study of the Photo-Electric Efficiency of Dye-Sensitized Solar Cells Under Lower Light Intensity

  • Kim, Hee-Je;Kim, Yong-Chul;Hong, Ji-Tae;Kim, Mi-Jeong;Seo, Hyun-Woong;Park, Je-Wook;Choi, Jin-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.513-517
    • /
    • 2007
  • To elucidate possible challenges for outdoor practical use of dye-sensitized solar cells (DSCs), we compared conventional Si solar cells with DSCs. DSC modules still require a larger area than conventional Si solar modules to attain the same rated output because of lower photoelectron-chemical conversion efficiency. However, in backup systems by using batteries, the measured data shows that DSCs generated 15% more electricity than Si solar cells of the same rated output power in the same interval of cloudy daylight. Moreover, the battery charging time of DSCs is about 1 hour faster than the same rate of Si solar cells under outdoor cloudy daylight. This result also indicates that conversion efficiency obtained by the certified condition less than AM 1.5 condition does not always coincide with the electricity generated outdoors daily, and it is not a crucial measure to evaluate the performance of solar cells.

Effects of the move towards Gen IV reactors in capacity expansion planning by total generation cost and environmental impact optimization

  • Bamshad, Ali;Safarzadeh, Omid
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1369-1377
    • /
    • 2021
  • Nowadays, it is necessary to accelerate the construction of new power plant in face of rising energy demand in such a way that the electricity will be generated at the lowest cost while reducing emissions caused by that generation. The expansion planning is one of the most important issues in electricity management. Nuclear energy comes forward with the low-carbon technology and increasing competitiveness to expand the share of generated energy by introducing Gen IV reactors. In this paper, the generation expansion planning of these new Gen reactors is investigated using the WASP software. Iran power grid is selected as a case of study. We present a comparison of the twenty-one year perspective on the future with the development of (1) traditional thermal power plants and Gen II reactors, (2) Gen III + reactors with traditional thermal power plants, (3) Gen IV reactors and traditional thermal power plants, (4) Gen III + reactors and the new generation of the thermal power plant, (5) the new generation of thermal power plants and the Gen IV reactors. The results show that the Gen IV reactors have the most developing among other types of power plants leading to reduce the operating costs and emissions. The obtained results show that the use of new Gen of combined cycle power plant and Gen IV reactors make the emissions and cost to be reduced to 16% and 72% of Gen II NPPs and traditional thermal power plants, respectively.

A Basic Experimental Study on Noise Energy Harvesting for Green Infrastructure (녹색사회기반시설의 소음에너지 하베스팅을 위한 기초실험 연구)

  • Jo, Byung-Wan;Kim, Hyun-Sik;Kim, Kyung-Tae;Yoon, Kwang-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.5
    • /
    • pp.559-565
    • /
    • 2010
  • In this study we propose noise energy harvesting for green infrastructure development. In this regard, infrastructures such as railroad, subway, and road are taken into consideration as sources of noise which provides energy through certain wave forms. As the need of recycling noise energy became reasonable due to the increase of infrastructure usage, the capacity and property of our noise energy generating device, which uses electromagnetic induction for electricity generation, are analysed in this paper. Consequently, the outcomes of this experiment show the fact that maximum electricity is generated from the device at a specific point of noise frequency, and the relation between air pressure caused by noise and the electricity generated by the device is in a specific proportional form either linear or non-linear. The major points of developing noise energy generating device in order to apply it into social infrastructure are discussed in this paper as well.

Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Power Supply Regulation (부하변동에 의한 지중유효열전도도와 보어홀 전열저항 해석)

  • Ro, Jeong-Geun;Yon, Kwang-Seok;Song, Heon
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.80-86
    • /
    • 2011
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. Another important factor is the borehole thermal resistance($R_b$). Thermal response tests offer a good method to determine the ground thermal properties for the total heat transport in the ground. This is done by supplying a constant heat power into a borehole heat exchanger. There are two methods to supply a constant heat power. One is to employ the electricity provided by Korea Electric Power Corporation(KEPCO). The other is to use electricity generated by a generator. In this study, the power supply regulation was found to reduce when the electricity generated by the generator was used. This is because the generator evaluated with the power supply characteristically reduces the power supply regulation between an overload and a complex using. But it sometimes occurs a power supply regulation in In-situ thermal response test. In this case getting of k,$R_b$ requires delay times and restored normal state. However, the effect of the delay times and restored normal state on the soil thermal conductivity and borehole thermal resistance is very small. Therefore it is possible to use a generally accepted delay times and restored normal state in the analysis. In this work, it is also shown that an acceptable range of ${\Delta}k$, ${\Delta}R_b$ for normal state and regulation state might be approximately 0.01-0.16W/m k, and -0.004-0.007m K/W, respectively. Thus, restored normal state of power supply regulation is valuable to recommend.