• Title/Summary/Keyword: General X-ray

Search Result 554, Processing Time 0.03 seconds

Study on crystallization behavior of an ethylene-polypropylene copolymer based encapsulant for photovoltaic application (태양전지 봉지재용 에틸렌-프로펠렌 공중합체의 결정화 거동에 관한 연구)

  • Son, Younggon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.737-742
    • /
    • 2016
  • We prepared five different ethylene-propylene copolymers (EPCs) for use as the encapsulant of a photovoltaic module. All of the polymers were of commercial grade from ExxonMobile company and had different ethylene/propylene compositions. The crystallization behaviors and crystal structures of the polymers were analyzed by differential scanning calorimetry and wide angle X-ray scattering diffractometry, respectively. We observed the general trend that the degree of crystallization, density and glass transition temperature of the EPCs decreased with increasing ethylene content. However, an unexpected result was also observed: the EPC with the highest ethylene content (22.2 mol. %) showed the highest melting temperature. As a result, the EPC with 22.2 mol. % of ethylene shows the highest light transmittance, due to its having the lowest degree of crystallization and highest thermal creep resistance. This abnormal result is attributed to the blocky structure prepared by ExxonMobile's special catalyst technology. It was also observed that new additional melting peaks appeared as the crystallization time increased. Using wide angle X-ray scattering diffractometry, it was confirmed that these additional peaks originated from the formation of a new crystal structure caused by annealing.

Dosimetric Characteristics of Multileaf Collimator-based Intensity-modulated Arc Therapy for Stereotactic Radiosurgery (방사선수술 시 다엽 콜리메이터를 기초로 한 IMAT의 선량분포)

  • Yun, Sang-Mo;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.93-97
    • /
    • 2007
  • This study was designed to evaluate radiosurgery technique using multiple noncoplanar arc therapy with intensity modulated fine MLC shaped photon beam. The stereotactic radiosurgery was performed with 6-MV X-ray beams from a Clinac 21EX LINAC (Varian, Palo Alto, CA, USA) with a MLC-120, which features a full $40{\times}40cm$ field and is the first MLC for general use that offers 0.5 cm resolution for high precision treatment of small and irregular fields. We used a single isocenter and five gantry-couch combinations with a set of intensity modulated arc therapy. We investigated dosimetric characteristics of 2 cm sized spherical target volume with film (X-OMAT V2 film, Kodak Inc, Rochester NY, USA) dosimetry within $25{\times}25cm$ acrylic phantom. A simulated single isocentric treatment using inversely Planned 3D radiotherapy planning system demonstrated the ability to conform the dose distribution to an spherical target volume. The 80% dose level was adequate to encompass the target volume in frontal, sagittal, and transverse planes, and the region between the 40% and 80% isodose lines was $4.0{\sim}4.5mm$ and comparable to the dose distribution of the Boston Arcs. We expect that our radiosurgery technique could be a treatment option for irregular-shaped large intracranial target.

  • PDF

Recovery of Nickel from Waste Iron-Nickel Alloy Etchant and Fabrication of Nickel Powder (에칭 폐액으로부터 용매추출과 가수분해를 이용한 니켈분말제조에 관한 연구)

  • Lee, Seokhwan;Chae, Byungman;Lee, Sangwoo;Lee, Seunghwan
    • Clean Technology
    • /
    • v.25 no.1
    • /
    • pp.14-18
    • /
    • 2019
  • In general after the etching process, waste etching solution contains metals. (ex. Nickel (Ni), Chromium (Cr), Zinc (Zn), etc.) In this work, we proposed a recycling process for waste etching solution and refining from waste liquid contained nickel to make nickel metal nano powder. At first, the neutralization agent was experimentally selected through the hydrolysis of impurities such as iron by adjusting the pH. We selected sodium hydroxide solution as a neutralizing agent, and removed impurities such as iron by pH = 4. And then, metal ions (ex. Manganese (Mn) and Zinc (Zn), etc.) remain as impurities were refined by D2EHPA (Di-(2-ethylhexyl) phosphoric acid). The nickel powders were synthesized by liquid phase reduction method with hydrazine ($N_2H_4$) and sodium hydroxide (NaOH). The resulting nickel chloride solution and nickel metal powder has high purity ( > 99%). The purity of nickel chloride solution and nickel nano powders were measured by EDTA (ethylenediaminetetraacetic) titration method with ICP-OES (inductively coupled plasma optical emission spectrometer). FE-SEM (field emission scanning electron microscopy) was used to investigate the morphology, particle size and crystal structure of the nickel metal nano powder. The structural properties of the nickel nano powder were characterized by XRD (X-ray diffraction) and TEM (transmission electron microscopy).

Characterizations and Quantitative Estimation of Alkali-Activated Binder Paste from Microstructures

  • Kar, Arkamitra;Ray, Indrajit;Halabe, Udaya B.;Unnikrishnan, Avinash;Dawson-Andoh, Ben
    • International Journal of Concrete Structures and Materials
    • /
    • v.8 no.3
    • /
    • pp.213-228
    • /
    • 2014
  • Alkali-activated binder (AAB) is recently being considered as a sustainable alternative to portland cement (PC) due to its low carbon dioxide emission and diversion of industrial wastes and by-products such as fly ash and slag from landfills. In order to comprehend the behavior of AAB, detailed knowledge on relations between microstructure and mechanical properties are important. To address the issue, a new approach to characterize hardened pastes of AAB containing fly ash as well as those containing fly ash and slag was adopted using scanning electron microscopy (SEM) and energy dispersive X-ray spectra microanalyses. The volume stoichiometries of the alkali activation reactions were used to estimate the quantities of the sodium aluminosilicate (N-A-S-H) and calcium silicate hydrate (CSH) produced by these reactions. The 3D plots of Si/Al, Na/Al and Ca/Si atom ratios given by the microanalyses were compared with the estimated quantities of CSH(S) to successfully determine the unique chemical compositions of the N-A-S-H and CSH(S) for ten different AAB at three different curing temperatures using a constrained nonlinear least squares optimization formulation by general algebraic modeling system. The results show that the theoretical and experimental quantities of N-A-S-H and CSH(S) were in close agreement with each other. The $R^2$ values were 0.99 for both alkali-activated fly ash and alkali-activated slag binders.

Evaluation of Image Quality by Using a Tungsten Edge Block in a Megavoltage (MV) X-ray Imaging (텅스텐 엣지 블록을 이용하여 Megavoltage (MV) 영상의 질 평가)

  • Min, Jung-Whan;Son, Jin-Hyun;Kim, Ki-Won;Lee, Jung-Woo;Son, Soon-Yong;Back, Geum-Mun;Kim, Jung-Min;Kim, Yeon-Rae;Jung, Jae-Yong;Kim, Sang-Young;Lee, Do-Wan;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.154-161
    • /
    • 2012
  • Digital Radiography (DR) has rapidly developed in megavoltage X-ray imaging (MVI). Thus, a very simple and general quality assurance (QA) method is required. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) for MVI using general QA method and computed radiography (CR) device. We used tungsten edge block with $19{\times}10{\times}1cm^3$ thickness and 6MV energy. For detector, CR-IP (image plate), CR-IP-lead, the CR-IP-back (lanex TM fast back screen), CR-IP-front (lanex TM fast front screen) were used and pre-sampling MTF was calculated. The MTF of CR-IP-front showed the highest value with 1.10 lp/mm although the CR-IP showed the only 0.70 lp/mm. The best NPS was observed in CR-IP front screen. According to the increase in spatial frequency, our results showed that DQE was approximately 1.0 cycles/mm. The present study demonstrates that the QA method with our home-made edge block can be used to evaluate MTF, NPS and DQE for MVI.

A Study on the Status of Medical Equipment and Radiological Technologists using Big Data for Health Care: Based on Data for 2020-2021 (보건의료 빅데이터를 활용한 의료장비 및 방사선사 인력 현황 연구 : 2020-2021년 자료를 기준으로)

  • Jang, Hyon-Chol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.667-673
    • /
    • 2021
  • As we enter the era of the 4th industrial revolution, it is judged that the scope of work of radiologists will be further expanded according to the innovation and advancement of radiation medical technology development. In this study, the current status of medical equipment and radiology technicians was identified, and basic data were provided for the plan for nurturing talents in the field of radiation medical technology in the era of the 4th industrial revolution, as well as career and employment counseling. Data from the second quarter of 2020 and the second quarter of 2021 were analyzed using health and medical big data. As a result of comparing the status of medical equipment by type in 2021 compared to 2020, C-Arm X-ray examination equipment increased by 5.83% to 6,638 units, followed by MRI examination equipment 1,811 units 5.29%, and angiography equipment 725 units 5.22% , general X-ray examination equipment 21,557 units increased 3.99%, CT examination equipment 2,136 units 3.03%, and breast examination equipment 3,425 units increased 3.00%. As a result of a comparison of the total number of radiologists in 2021 compared to 2020, the number was 29,038, an increase of 2.73%. As a result of comparing the status of radiographers by region, the increase was highest in the Gyeonggi region with 5.96%, followed by the Gangwon region with a 5.66% increase and the Chungnam region with a 3.81% increase. In a situation where the number of medical equipment and radiologist manpower is increasing, universities are developing specialized knowledge and practical competency through subject development related to the understanding and utilization of customized artificial intelligence and big data that can be applied in the medical radiation technology field in the era of the 4th industrial revolution. It is necessary to nurture qualified radiographers, and at the level of the association, it is thought that active policies are needed to create new jobs and improve employment.

Characteristics of Individuals Seeking Comprehensive Health Check-ups (종합 건강검진을 원하는 피검진자의 건강특성에 관한 연구)

  • 성미혜
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.3
    • /
    • pp.563-576
    • /
    • 1997
  • This study was carried out to identify basic data for more efficient operation of comprehensive health check-up centers in the national health care system. The researcher reviewed and analyzed the main symptoms of the subjects according to sex, age, occupation and positive rate in the screening tests of a comprehensive health check-up, performed at one comprehensive health check-up center in located in a hospital. The subjects were 512 persons who had a check-up at the comprehensive health check-up, center in K university hospital in Seoul from October 2, 1996 to March 30, 1997. A questionaire developed by the researcher to obtain subject's general characteristics, main symptoms, medical examination, diagnosed disease was used as the tool for the study. The researcher analyzed the data with SPSS PC/sup +/ program. : the distribution of the subject's general characteristics and main symptoms was described with percentages and the difference between main symptoms and screening tests analyzed with X²-test, t-test, ANOVA. The result of this study are as follows : 1. For the distribution of diagnosis in males. liver disease was most frequent and hypertension was second : in females, hypertention and liver disease were not common in that order. 2. The most common complaints were indigestion in the digestive system, sputum in the respiratory system, irregular heart beat in the cardiovascular system, frequent urine in the urinary system vertigo in the hematologic system. 3. The main symptoms according to sex were for females, a statistically siguificant higher rate of complaints in the digestive system, cardiovascular system, urinary system, hematologic system, musculoskeletal, mental & nervous system as compared to males. 4. The main symptoms according to age were that in the the second decade there wara higher rate of complaints in the digestive system, and cardiovascular system than in the older age groups : and in the fifth decade more in the musculoskeletal system. 5. The main symptoms according to occupation were that formers and fishers had a higher rate of complaints in the mental and nervous system as compared to other occupation groups : and office workers, in gynecology. 6. The main symptoms according to diagnosis, were symptoms of the digestive system, frequent in liver disease : symptoms of the cardiovascular system in allergic disease. 7. The screening tests which showed the highest rates were UGI /FGS, PFT : In males a higher rate of abnormality was seen in abdominal ultrasono- graphy and in, females, in mammography. 8. In screening tests according to sex, males showed a higher positive rate for chest X-rays, and LFT, and females, in mammography, pap smear, CBC. 9. In screening tests according to age, higher positive rates of obesity, high blood pressure, chest X-ray, mammography, pap smear, FBS, CBC, urine test were seen in the fifth decade : PFT and abdominal ultrasonography in the third decade. The subjects who wanted comprehensive health check-up were not asymptomatic but had an illness with several symptoms. It is found that the most frequent diagnosed diseases were hypertention and liver disease. So proper observations must be done for them. Comprehensive health check-ups should be changed to a comprehensive examination including treatment beyond examination for those subjects with positive results.

  • PDF

Surgical Treatment of Traumatic Ventricular Septal Defect by Penetrating Chest Injury (흉부관통상으로 인한 심실중격결손의 치료)

  • 김시욱;한종희;강민웅;나명훈;임승평;이영;최시완;유재현
    • Journal of Chest Surgery
    • /
    • v.37 no.12
    • /
    • pp.999-1002
    • /
    • 2004
  • Thirteen year old boy who had been stabbed in his left chest by the knife was transferred to our department from a general hospital, because of the massive bleeding from the intercostal tube drainage. Chest X-ray showed homogeneous density in the left lung field. He was confused and his vital signs were unstable. He was moved into a operating room as soon as possible. After resuscitation, his lacerated left ventricle wound was sutured through median sternotomy. The interventricular shunt was detected with intraoperative transesophageal echocardiography. The traumatic ventricular septal defect was closed via left ventricle using Dacron patch. His postoperative course was uneventful, and he was discharged with small residual shunt.

WISE AND AKARI

  • Blain, Andrew W.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.367-373
    • /
    • 2012
  • The first all-sky mid-/far-infrared survey by IRAS in the 1980s, has been followed by only two more, by AKARI, from 2006, and WISE in 2010. I discuss some features of the WISE survey, and highlight some key results from early extragalactic observations that have been made by the science team during the operation of the telescope, and the post-operation proprietary period during which the public release data products were being generated. The efficient survey strategy and very high-data rate from WISE produced a catalogue of 530 million objects that was released to the public in March 2012. The WISE survey strategy naturally provided the deepest coverage at the ecliptic poles, where matched comparison fields were obtained using Spitzer, and where AKARI also observed deep fields. I describe some of the follow-up work that has been carried out based on the WISE survey, and the prospects for enhancing the WISE data by combining the AKARI survey results are also discussed. While the all-sky AKARI survey is less deep than the WISE catalogue, and is still being worked on by the AKARI science team, it includes a larger number of bands, extends to longer wavelengths, and in particular has very complementary band passes to WISE in the mid-infrared waveband, which will provide enhanced spectral information for relatively bright targets.

A CASE OF SURGICAL TREATMENT FOR SYMPTOMATIC ELONGATED STYLOID PROCESS (이상경상돌기증의 치험례)

  • Kim, Chang-Hwan;Kim, Eun-Goan;Park, Hyo-Sang;Park, No-Boo;Lee, Yong-Oh
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.3
    • /
    • pp.348-355
    • /
    • 1994
  • Styloid process is a slender pointed bone of variable length, which project downward, forward, and slightly medialward from the posteroinferior portion of the tympanic part of the temporal bone. Embryologically, the styloid process is derived from Reichert's cartilage, a structure of second branchial arch origin. Most patients with elongated styloid process remain asymptomatic, but some patients complain pain and sensation of foreign body in the throat, dysphagia, dysphonia, referred otalgia. Recently, we have experienced a case of elongated styloid process in a fifty-nine year old man. He had been suffered from Rt. side sore throat, headache and pharyngeal discomfort during head movement. Through various X-ray examination, Xeroradiography, and palpation of tonsillar fossa, elongated styloid process on Rt. side was confirmed. Under the general anesthesia, it was successfully removed out via transoral approach technique, described by Eagle. The resected styloid process was 2.5cm in it's length and he was freed from the symptoms without further complication.

  • PDF