Analysis of Counting Rate according to Presence or Absence of Detector's Protector in Beta-rays Measurement using Geiger-Muller Counter (Geiger-Muller 계수관을 이용한 베타선측정에서 디텍터 보호유무에 따른 계수율 분석)

  • Jang, Ji-Yong;Jeong, Moon-Taeg;Song, Jong-Nam;Ha, Jae-Jun;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.31-37
    • /
    • 2018
  • In the surface contamination test using the end-window Geiger-Muller type counter, the wrap is used as a method for protecting the detector exposed to the outside in order to measure the beta-rays. We analyze the effect of this method on the measurement rate and the correction factor, and wanted to make it clear to radiation workers that excessive use of the wrap can affect the measured value of the beta-rays. The experimental method was to compare and analyze the change of the beta-rays measurement counting rate and the calibration factor according to the wrap thickness using the beta-rays with different energy of 3 KBq, 1.5 KBq and 0.3 KBq. The subjects of this study were the end-window Geiger-Muller type counter which were held at the calibration center certified by Korea Laboratory Accreditation Scheme (KOLAS) in March 2012, Cl-36 (Chlorine) and Sr-90 (Strontium) were used as the source of beta radiation. The measurement counting rate decreased with increasing wrap thickness, and the calibration factor increased with increasing wrap thickness. Since the changes of the measurement counting rate and the calibration factors can reduce the accuracy of the instrument readings, but also have a significant impact on detector contamination and damage, so there is a need to find out what thickness of wrap is most effective. If we using a wraps with thickness that show a low rate of change of the measurement counting rate and the calibration factor, it will protect the detector and minimize the effect on the measured value of the beta-rays.

PDA based Bluetooth Wireless Radiation Counter (PDA기반의 블루투스 무선통신 방사선 측정 장치)

  • Im, Sang-Heui;Park, Dae-Sung;Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.1
    • /
    • pp.5-10
    • /
    • 2008
  • This study developed a PDA based wireless communication radiation measuring instrument using Bluetooth. The proposed system is composed of Student Radiation Monitor of Vernier using GM (Geiger Mueller) counter tube as a radiation measuring sensor, LabPro of Vernier as a module for data collection, Promi SD 101 of Initium, which can make Bluetooth communication up to 30 m, for wireless data transmission, and HP 5550 embedded with Pocket PC 2003 as OS for data storage and display. Because GM counter tube is used as a radiation measuring sensor, the system cannot measure radiation energy but measures count volume and count rate. When the result of natural radiation measuring by the PDA based system was compared with that by a PC based system, it was found that the proposed system transmits and receives data without distortion.

  • PDF

Studies on Phosphorus-32 Labeling of the House Fly ( I ) (Phosphorus-32에 의한 집파리의 표식효과 (I))

  • Ryu J.;Chung K. H.;Kwon S. H.;Kim H. W.
    • Korean journal of applied entomology
    • /
    • v.13 no.2 s.19
    • /
    • pp.93-97
    • /
    • 1974
  • This paper describes experiments made to develop a technique for marking insects and get the informations for ecological studies as a means of tagging flies with radioactive phosphorus, and also to learn the effect on the subsequent generation of flies. Tests were conducted with house flies, Musca domestica L. emerged front the larvae that had reared in a media containing various concentrations of P-32. Radioactivity of the flies was measured with end-window type $(2mg/cm^2)$ Geiger-Muller counter and proportional counter made by Aloka. In following the daily increases in counting rates by 6-day-old larvae it was apparent the larvae in the starting media containing the higher concentrations of P-32 were showing high counting rates. It was found that about 13.2 per cent of the radioactive material remained in the empty puparia after the flies emerged. Radioactivity of the emerged flies decreased gradually and the biological halflife of phosphorus-32 was approximately 6.14 days with considerable variation. A significant amount of P-32 were detected in the abdominal and thoracic sections as compared with other parts of adult. The activity of phosphorus·32 in eggs and larvae produced by adults reared in medium containing 0.2 microcurie or more of P-32 per gram were readily detected with Geiger-Mi·lier counter. On the other hand, the radioactivity of eggs and larvae produced by the treated males crossed with untreated normal females could be only detected in the medium containing more of 2.0 microcurie with G.M. counter. There was no apparent damage to the flies at dosages as high as 0.5 microcurie per gram of medium. For field studies a concentration of 0.5 microcurie of P-32 per gram of artificial medium appears to give adequate labeling for positive identification of flies and their egg masses.

  • PDF

Clinical Usefulness of 14C-Urea Breath Test for the Diagnosis of H. pylori Infection (H. pylori 감염 진단 시 14C-요소호기검사의 임상적 유용성)

  • Kim, Yoon-Sik
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.3
    • /
    • pp.271-276
    • /
    • 2007
  • Helicobacter pylori (H. pylori) infection is common in korea and high incidence at gastric ulcer and duodenal ulcer. $^{14}C-urea$ breath test ($^{14}C-UBT$) is regarded as a highly reliable and non-invasive method for the diagnosis of H. pylori infection. The purpose of this study was to evaluate the diagnositc performance of a new and rapid $^{14}C-UBT$, which was equipped with Geiger-Muller counter and compared the results with those obtained by gastroduodenoscopic biopsies (GBx). One hundred sixty-eight patients (M : F = 118 : 50) underwent $^{14}C-UBT$, rapid urease test (CLO test), and GBx. The results of $^{14}C-UBT$ were classified as positive (>50 cpm), borderline (25$^{14}C-UBT$ or CLO test results with GBx as a glod standard. In the assessment of the presence of H. pylori infection, the $^{14}C-UBT$ global performance yielded positive predictive value, negative predictive value and accuracy of 93.3% and 83.3%, respectively. However, the CLO test had performance yielded positive predictive value, negative predictive value and accuracy of 76.9%, 50.0%, respectively. In this study $^{14}C-UBT$ is a highly accurate, simple and non-invasive method or the diagnosis of follow up H. pylori infection.

  • PDF

A Study on Dose Assessment by 18F-FDG injected into Patients (환자에게 주입된 18F-FDG 의한 선량 평가에 대한 연구)

  • Kim, Chang-Ju;Kim, Jang-Oh;Jeong, Geun-Woo;Shin, Ji-Hey;Lee, Ji-Eun;Jeon, Chan-Hee;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.467-475
    • /
    • 2020
  • The purpose of this study is to assess doses to 18F-FDG, a radioactive drug, during PET examinations, to alleviate anxiety about radiation in patients and carers, to minimize the indiscriminate examination progress caused by medical institution personnel and space clearance problems, and health examination. The dose assessment was measured using a thermo-fluorescent dosimeter (TLD) and an electronic personal dosimeter (EPD) at the location of the cervical (hypothyroid), thorax (heart), and lower abdomen (breeding line) which are the three highest tissue areas of the radiation tissue weighting. In addition, spatial dose rates and radioactivity in urine were measured using GM counters and ion boxes. The results are as follows: First, the personal dosimeter TLD was measured 0.0425±0.0277 mSv in the cervical region, 0.0440±0.0386 mSv in the thorax and 0.0485±0.0436 mSv in the lower abdomen, with little difference in the heart dose depending on radiation sensitivity. The EPD was measured at 0.942±0.141 mSv/h immediately after the cervical position, and 0.192±0.031 mSv/h after 120 minutes. Immediately after the thorax position, 0.516±0.085 mSv/h, 120 minutes later 0.128±0.040 mSv/h. Immediately after the lower abdomen position, 0.468±0.091 mSv/h, and after 120 minutes 0.105±0.021 mSv/h were measured. The spatial dose rate at the GM counter was measured immediately at 0.041±0.005 mSv/h, 120 minutes later at 0.014±0.002 mSv/h. The radioactivity in urine using ion chamber was measured at 0.113±0.24 MBq/cc after 60 minutes and 0.063±0.13 MBq/cc after 120 minutes. As a result, 18F-FDG should be administered, dose re-evaluated two hours after the PET test is completed, and caregivers should be avoided. In addition, it is deemed necessary to provide patients and carers with sufficient explanations and expected values of exposure dose to avoid reckless testing. It is hoped that the data tested in this study will help patients and families relieve anxiety about radiation, and that the radiation workers' exposure management system and institutional improvements will contribute to the development of medical radiation.