• Title/Summary/Keyword: Ge-18

Search Result 350, Processing Time 0.025 seconds

Biological activities in Aronia melanocarpa depending on drying methods (건조방법에 따른 아로니아의 생리활성)

  • Lee, Seul;Moon, Hey-Kyung;Lee, Su-Won;Moon, Jae-Nam;Kim, Jong-Kuk
    • Food Science and Preservation
    • /
    • v.23 no.7
    • /
    • pp.1018-1025
    • /
    • 2016
  • To investigate biological activities in Aronia melanocarpa various drying methods were employed such as vacuum freeze drying, hot air drying and cold air drying. DPPH radical scavenging activity and ABTS radical scavenging activity of vacuum freeze dried Aronia melanocarpa was higher than hot and cold air dried Aronia melanocarpa. Vacuum freeze drying method showed the greatest contents of total phenol (15.34 g GAE/100 g), flavonoid (3.10 g GE/100 g) and tannin (2.46 g TE/100 g). Total anthocyanin content decreased to 163.52 mg C3G/100 g and 50.15 mg C3G/100 g for hot and cold air drying, respectively. Vacuum freeze-dried method increased the total anthocyanin content (743.09 mg C3G/100 g) when compared with fresh Aronia melanocarpa (163.52 mg C3G/100 g). Total proanthocyanidin content of vacuum freeze dried Aronia melanocarpa has increased to 6.21 g CE/100 g more than eight times compared with fresh Aronia melanocarpa (0.71 g CE/100 g). Chlorogenic acid and neochlorogenic acid content of vacuum freeze dried Aronia melanocarpa were higher than hot air dried and cold air dried Aronia melanocarpa, increasing about three times compared with fresh Aronia melanocarpa. These results suggested that vacuum freeze drying is optimal drying method to enhance biological activities in Aronia melanocarpa.

Effect of Antibiotic Combination Therapy on Metallo-${\beta}$-Lactamase Producing Imipenem Resistant Pseudomonas aeruginosa (Metallo-${\beta}$-lactamase를 생성하여 Imipenem에 내성인 Pseudomonas aeruginosa에 대한 항균제 병합요법의 효과)

  • Hong, Seung-Bok;Kim, Hong Chul;Lee, Jang-Won;Son, Seung-Yeol
    • Korean Journal of Microbiology
    • /
    • v.44 no.4
    • /
    • pp.339-345
    • /
    • 2008
  • This study was to detect MBL (metallo-${\beta}$-lactamase) among glucose non-fermenting Gram-negative bacilli isolated from clinical specimen and to search antimicrobial combination therapy against MBL producing Pseudomonas aeruginosa. Among fifty one isolates of Gram-negative bacilli with reduced imipenem susceptibility ($MIC{\ge}8{\mu}g/ml$), nine isolates have shown positive results in MBL detection test. They were seven Achromobacter xylosoxidans subsp. xylosoxidans and two P. aeruginosa. The results from EDTA-DDST coin-cided with those of PCR and nucleotide sequence analysis which showed the presence of $bla_{VIM-2}$. The combination of aztreonam (AZT) and piperacillin-tazobactarn (TZP) or AZT and amikacin (AN) screened by one disk synergy test showed no synergistic effect. Triple antibiotic combination therapy with AZT, TZP and AN, however, was shown to be effective and the most synergistic after 8 hrs of exposure. This result strongly suggest that the triple combination therapy of AZT, TZP, and AN could be useful for the treatment of infection caused by MBL producing Gram-negative bacilli.

The Environment-Friendly High Quality Pork Production by feeding the Fermentation Products of Natural Clay Mineral (천연의 점토광물질 발효산물 급여에 의한 친환경 고품질 원료돈육 생산)

  • Cho, Jin Kook;Yang, Seung Hak;Hwang, Seong Gu
    • Journal of Animal Environmental Science
    • /
    • v.18 no.sup
    • /
    • pp.55-64
    • /
    • 2012
  • We investigated the effect of the clay mineral fortified with complex trace elements by specific fermentation microbes on growth performance and a quality of pork in this study. For the declared experimental animal, 80 heads of crossbred with Large White and Yorkshire were randomly splitted into a control group and a test group. Each group were assigned with 4 replicates and 10 heads of each replicate. When 0.3% of the fermentation product of the clay mineral (FCM) was added into feed stuff and fed for 9 weeks of experimental feeding period, the results of the feed intake, weight gains, pH of carcass, lightness of meat color, and brightness of the muscle semimembranosus were similar to those of the control group. However, dressing percentage, reddishness of carcass, and water holding capacity were improved, respectively, as much as 2.7%, 12%, and 10%, and reduced by 6% in cooking loss. In order to investigate the immune modulatory effect of fermented clay mineral, pheripheral blood mononuclear cells (PBMC) were isolated and Immune modulatory parameters were measured. The proliferation activity of PBMC from pigs fed the fermented clay mineral were significantly increased compared to control group pigs, and also those results were more clearly observed as activated with lipopolysaccharide and concanavaline A. The secretion of TNF-${\alpha}$ of the FCM group pigs showed an increasing tendency. Therefore it was suggested that the feeding of FCM which was high in cation metathesis and the value of infrared ray, activated the immune responses, and thus the production of the environment-friendly high quality pork without the use of antibiotics would be possible.

Determination of Mineral and Heavy Metal Contents of Various Salts (소금의 종류별 무기질 및 중금속 함량)

  • Park, Jeong-Wook;Kim, Seon-Jae;Kim, Sul-Hee;Kim, Bo-Hee;Kang, Seong-Gook;Nam, Sang-Ho;Jung, Soon-Teck
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.1442-1445
    • /
    • 2000
  • This study was carried out to investigate the contents of minerals and heavy metals in the sea salts of Korean products and imported products. NaCl was major component, which ranged from $80.31{\sim}89.84%$ for Korean products and from $91.59{\sim}97.66%$ for imported products. Minerals and heavy metals of Korean products and imported products were analyzed with ICP-AES and AAS, respectively. Mineral contents of K and Mg in Korean products were relatively higher than those in imported ones, but no significant differences were found for heavy metals between them.

  • PDF

Feasibility of Three-Dimensional Balanced Steady-State Free Precession Cine Magnetic Resonance Imaging Combined with an Image Denoising Technique to Evaluate Cardiac Function in Children with Repaired Tetralogy of Fallot

  • YaFeng Peng;XinYu Su;LiWei Hu;Qian Wang;RongZhen Ouyang;AiMin Sun;Chen Guo;XiaoFen Yao;Yong Zhang;LiJia Wang;YuMin Zhong
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1525-1536
    • /
    • 2021
  • Objective: To investigate the feasibility of cine three-dimensional (3D) balanced steady-state free precession (b-SSFP) imaging combined with a non-local means (NLM) algorithm for image denoising in evaluating cardiac function in children with repaired tetralogy of Fallot (rTOF). Materials and Methods: Thirty-five patients with rTOF (mean age, 12 years; range, 7-18 years) were enrolled to undergo cardiac cine image acquisition, including two-dimensional (2D) b-SSFP, 3D b-SSFP, and 3D b-SSFP combined with NLM. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) of the two ventricles were measured and indexed by body surface index. Acquisition time and image quality were recorded and compared among the three imaging sequences. Results: 3D b-SSFP with denoising vs. 2D b-SSFP had high correlation coefficients for EDV, ESV, SV, and EF of the left (0.959-0.991; p < 0.001) as well as right (0.755-0.965; p < 0.001) ventricular metrics. The image acquisition time ± standard deviation (SD) was 25.1 ± 2.4 seconds for 3D b-SSFP compared with 277.6 ± 0.7 seconds for 2D b-SSFP, indicating a significantly shorter time with the 3D than the 2D sequence (p < 0.001). Image quality score was better with 3D b-SSFP combined with denoising than with 3D b-SSFP (mean ± SD, 3.8 ± 0.6 vs. 3.5 ± 0.6; p = 0.005). Signal-to-noise ratios for blood and myocardium as well as contrast between blood and myocardium were higher for 3D b-SSFP combined with denoising than for 3D b-SSFP (p < 0.05 for all but septal myocardium). Conclusion: The 3D b-SSFP sequence can significantly reduce acquisition time compared to the 2D b-SSFP sequence for cine imaging in the evaluation of ventricular function in children with rTOF, and its quality can be further improved by combining it with an NLM denoising method.

Evaluation of Proper Image Acquisition Time by Change of Infusion dose in PET/CT (PET/CT 검사에서 주입선량의 변화에 따른 적정한 영상획득시간의 평가)

  • Kim, Chang Hyeon;Lee, Hyun Kuk;Song, Chi Ok;Lee, Gi Heun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.22-27
    • /
    • 2014
  • Purpose There is the recent PET/CT scan in tendency that use low dose to reduce patient's exposure along with development of equipments. We diminished $^{18}F$-FDG dose of patient to reduce patient's exposure after setting up GE Discovery 690 PET/CT scanner (GE Healthcare, Milwaukee, USA) establishment at this hospital in 2011. Accordingly, We evaluate acquisition time per proper bed by change of infusion dose to maintain quality of image of PET/CT scanner. Materials and Methods We inserted Air, Teflon, hot cylinder in NEMA NU2-1994 phantom and maintained radioactivity concentration based on the ratio 4:1 of hot cylinder and back ground activity and increased hot cylinder's concentration to 3, 4.3, 5.5, 6.7 MBq/kg, after acquisition image as increase acquisition time per bed to 30 seconds, 1 minute, 1 minute 30 seconds, 2 minute, 2 minutes 30 seconds, 3 minutes, 3 minutes 30 seconds, 4 minutes, 4 minutes 30 seconds, 5 minutes, 5 minutes 30 seconds, 10 minutes, 20 minutes, and 30 minutes, ROI was set up on hot cylinder and back radioactivity region. We computated standard deviation of Signal to Noise Ratio (SNR) and BKG (Background), compared with hot cylinder's concentration and change by acquisition time per bed, after measured Standard Uptake Value maximum ($SUV_{max}$). Also, we compared each standard deviation of $SUV_{max}$, SNR, BKG following in change of inspection waiting time (15minutes and 1 hour) by using 4.3 MBq phantom. Results The radioactive concentration per unit mass was increased to 3, 4.3, 5.5, 6.7 MBqs. And when we increased time/bed of each concentration from 1 minute 30 seconds to 30 minutes, we found that the $SUV_{max}$ of hot cylinder acquisition time per bed changed seriously according to each radioactive concentration in up to 18.3 to at least 7.3 from 30 seconds to 2 minutes. On the other side, that displayed changelessly at least 5.6 in up to 8 from 2 minutes 30 seconds to 30 minutes. SNR by radioactive change per unit mass was fixed to up to 0.49 in at least 0.41 in 3 MBqs and accroding as acquisition time per bed increased, rose to up to 0.59, 0.54 in each at least 0.23, 0.39 in 4.3 MBqs and in 5.5 MBqs. It was high to up to 0.59 from 30 seconds in radioactivity concentration 6.7 MBqs, but kept fixed from 0.43 to 0.53. Standard deviation of BKG (Background) was low from 0.38 to 0.06 in 3 MBqs and from 2 minutes 30 seconds after, low from 0.38 to 0 in 4.3 MBqs and 5.5 MBqs from 1 minute 30 seconds after, low from 0.33 to 0.05 in 6.7 MBqs at all section from 30 seconds to 30 minutes. In result that was changed the inspection waiting time to 15 minutes and 1 hour by 4.3 MBq phantoms, $SUV_{max}$ represented each other fixed values from 2 minutes 30 seconds of acquisition time per bed and SNR shown similar values from 1 minute 30 seconds. Conclusion As shown in the above, when we increased radioactive concentration per unit mass by 3, 4.3, 5.5, 6.7 MBqs, the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the same way, in the change of inspection waiting time (15 minutes and 1 hour), we could find that the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the result of this NEMA NU2-1994 phantom experiment, we found that the minimum acquisition time per bed was 2 minutes 30 seconds for evaluating values of fixed $SUV_{max}$ and SNR even in change of inserting radioactive concentration. However, this acquisition time can be different according to features and qualities of equipment.

  • PDF

Evaluation of SUV Which was Estimated Using Mini PACS by PET/CT Scanners (PET/CT 장비 별 mini PACS에서 측정한 표준섭취계수(SUV)의 유용성 평가)

  • Park, Seung-Yong;Ko, Hyun-Soo;Kim, Jung-Sun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.47-52
    • /
    • 2011
  • Purpose: Facilities use own sever or mini PACS system for storage and analysis of the PET/CT data. Mini PACS can storage scan data as well as measuring SUV. Therefore, the study was performed to confirm whether or not measured SUV on mini PACS is measured equally on PET/CT workstation. Materials and Methods: In February 2011, 30 patients who were performed $^{18}F$-FDG wholebody PET/CT scan in Biograph 16, Biograph 40 and Discovery Ste 8 were enrolled. First, using each workstation, SUV in liver and aorta of mediastinum level was measured. Second, using mini PACS, SUV was measured by same method. Result: The correlation coefficient of SUV in liver between PET/CT scanner and min PACS in Biograph 16, Biograph 40, Discovery Ste 8 was 0.99, 0.98, 0.64 respectably, the correlation coefficient of SUV in aorta was 0.98, 0.98, 0.66, and these were showed positive correlation coefficient. Difference of SUV between Biograph workstation and mini PACS was not showed statistical significant difference at 5% level of significance. Difference of SUV between Discovery Ste 8 workstation and mini PACS was showed statistical significant difference at 5% level of significance. Conclusion: In case that patient was scanned by the other scanner, if the correction of SUV formula in mini PACS for each scanners is performed, mini PACS will be usefully used to provide consistently quantitative assessment.

  • PDF

A Comparative Study on the CT Effective Dose by the Position of Patient's Arm (전신 PET/CT 검사에서 환자의 팔 위치에 따른 CT 유효선량의 비교 연구)

  • Seong, Ji-Hye;Park, Soon-Ki;Kim, Jung-Sun;Park, Seung-Yong;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.44-49
    • /
    • 2012
  • Purpose: In the whole body PET/CT scan, it is natural to lift the patient's arm for its quality improvement. However, when the lesion is located in head and neck, the arms should be located lower. This study was designed to compare the CT effective dose for each arm position applying Automatic Exposure Control (AEC). Materials and Methods: 45 patients who had $^{18}F$-FDG whole body PET/CT scan were studied with Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY), Discovery STe 8 (GE healthcare, USA). The CT effective dose of 15 patients for each equipment was measured and comparatively analyzed in both arm-lifted position and lower-arm position. ImPACT v1.0 program was used as the method of measurement for CT effective dose. For the statistics analysis, Paired t-test which paired with SPSS 18.0 statistic program was applied. Results: In the case of arm-lifted, it was measured as $6.33{\pm}0.93mSv$ for Biograph Sensation 16, $8.01{\pm}1.34mSv$ for Biograph Truepoint 40, and $9.69{\pm}2.32mSv$ for Discovery STe 8. When arms are located lower position, it was measure as $6.97{\pm}0.76mSv$, $8.95{\pm}1.85mSv$, $13.07{\pm}2.87mSv$ for each. CT effective dose according to the arm position was 9.2% for Biograph Truepoint 40, 10.5% for Biograph Sensation 16, and 25.9% for Discovery Ste 8. The statistics analysis showed the meaningful difference ($p$<0.05). Conclusion: For the whole body PET/CT case, CT effective dose applying AEC was decreased the radiation exposure of the patients when the arm was lifted for 15.2% of average value. The patient who has no lesion in head and neck would decrease the artifact occurrence in objective part and lower the CT effective dose. Also, for the patient who had lesion in head and neck, the artifact in objective part can be lower by putting the arms down, the fact that CT effective dose increases should be concerned in its whole body PET/CT scan.

  • PDF

Alcohol Intake in Relation to Cardiovascular Risk Factors among (Middle Age) South Korean Men (한국의 중년기 남성의 심혈관계 질환 위험요인과 음주섭취와의 관련성)

  • Park, Kyung-Min
    • Research in Community and Public Health Nursing
    • /
    • v.9 no.1
    • /
    • pp.232-241
    • /
    • 1998
  • 음주습관과 심혈관계 질환 위험요인사이의 관련성을 파악하기 위하여, 1996년 한국 경북에 있는 도시지역 한 철강회사에서 40-50대(40-59세) 남자 근로자 3444명으로부터 공복시 혈액을 10m1 채취하여 혈청지질, 혈당, Uric acid를 측정하고 신장, 체중, 혈압(10-20분 휴식후 측정)과 EKG를 측정하였다. 과거병력, 현재 건강상태, 음주량과 기간 및 음주종류를 포함한 생활습관, 흡연량/일, 운동시간/주 등의 설문지를 작성하였다. 알콜 소비량은 양-빈도의 Index에 의해 측정되었다. 한국 중년 남자에 대한 음주량, 음주기간, 알콜종류등에 따른 심혈관계 질환의 위험요인 유무 정도를 알아보기 위해, 비음주자를 기준으로하여 비교대상군은 금주자와 음주량(2군) 등에 의해 3군으로 분류하였으며, 음주기간에 따른 심혈관계 질환의 위험요인 유무정도를 알아보기 위해 비음주자을 기준으로하여 비교 대상군은 금주자와 음주기간(4군)에 따라 5군으로 분류하였다. 알콜종류에 따른 심혈관계 질환의 위험요인 유무정도를 알아보기 위해 비음주자을 기준으로하여 비교 대상군은 금주자와 음주알콜종류(3군)에 따라 4군으로 분류하였다. 심혈관계 질환 위험요인은 기준되는 범주를 2개(Table 1)로 분류하여 2*2표를 이용하여 odds ratio(dummy variable로 처리), ${\beta}$-coefficient와 표준오차를 이용해서 신뢰구간(95% C.I.)을 구하여 유의성 검정을 하였다. 금주자의 정의는 과거 3달 이상 술을 마시지 않는 사람을 말한다. 연구 집단의 평균 연령은 $44.4{\pm}3.9$세 이며, 비음주자는 649명으로 18.9%, 금주자는 70명(2.0%)이며 음주자는 2725명(79.1%)이다. 음주자중 에타놀 섭취를 평균 100.5g/주(median) 미만인 군은 1239명으로 연구집단 3444명중 35.7%이며, 평균 100.5g/주(median) 이상 음주군은 1276명으로 44.5%이었다. 3444명중 1532명(44.5%) 이 맥주와 소주를 섞어서 마시는 사람이었다. 음주 양에서, 연령, 흡연 양, 흡연 기간, 운동, 음주기간, 알콜종류 등을 통제하여 logistic regression한 결과, 비음주자에 비해 중정도 음주자(${\ge}$100.5gm/week ethanol)의 확장기 혈압의 Odds ratio는 1.33배로 유의하게 높았다(P<0.05). 다른 요인들은 통계적으로 유의한 차이를 보이지 않았다. 알콜종류에서도 연령, 흡연 양, 흡연 기간, 운동, 음주양, 음주기간, 등을 통제한, 비음주자에 비해 맥주와 소주를 섞어 마시는 음주자의 확장기 혈압의 Odds ratio는 1.38배로 유의하게 높았다(P<0.01). 다른 요인들은 통계적으로 유의한 차이를 보이지 않았다. 반면에 음주 습관 중 음주기간에서는 연령, 흡연양, 흡연 기간, 운동, 음주양, 알콜종류 등을 통제한 logistic regression 분석 결과 유의한 차이를 보인 것은 없었다. 그러나 음주기간과 심혈관계 질환 위험요인중 수축기와 확장기 혈압과의 관계는 J 모양을 나타내었다 . 수축기 혈압의 금주자군은 비차비가 1.0보다 약간 낮고(Odds ratio=0.88) 음주기간이 2-10년인 군의 Odds ratio=1.14, 음주기간이 11-20 년인군의 Odds ratio =1.18, 21년 이상인 군의 Odds ratio=1.20로 비음주자의 odds ratio=1에 비해 점차적으로 위험이 높아졌다. 확장기 혈압의 금주자군은 비차비가 1.0보다 약간 낮고(Odds ratio=0.91), 음주기간이 1년 이하인 군의 Odds ratio=1.18, 음주기간이 2-10 년인 군의 Odds ratio=1.23, 음주기간이 11-20 년인 군의 Odds ratio=1.27, 21년 이상인 군의 Odds ratio=1.27로 비음주자의 odds ratio=1에 비해 점차적으로 위험이 높아졌다.

  • PDF

Analysis of Patient Effective Dose in PET/CT; Using CT Dosimetry Programs (CT 선량 측정 프로그램을 이용한 PET/CT 검사 환자의 예측 유효 선량의 분석)

  • Kim, Jung-Sun;Jung, Woo-Young;Park, Seung-Yong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.77-82
    • /
    • 2010
  • Purpose: As PET/CT come into wide use, it caused increasing of expose in clinical use. Therefore, Korea Food and Drug Administration issued Patient DRL (Diagnostic Reference Level) in CT scan. In this study, to build the basis of patient dose reduction, we analyzed effective dose in transmission scan with CT scan. Materials and Methods: From February, 2010 to March 180 patients (age: $55{\pm}16$, weight: $61.0{\pm}10.4$ kg) who examined $^{18}F$-FDG PET/CT in Asan Medical Center. Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY) and Discovery STe8 (GE healthcare, USA) were used in this study. Per each male and female average of 30 patients doses were analyzed by one. Automatic exposure control system for controlling the dose can affect the largest by a patient's body weight less than 50 kg, 50-60 kg less, 60 kg more than the average of the three groups were divided doses. We compared that measured value of CT-expo v1.7 and ImPACT v1.0. The relationship between body weight and the effective dose were analyzed. Results: When using CT-Expo V1.7, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.46{\pm}1.18$ mSv, $9.36{\pm}1.96 $mSv and $9.36{\pm}1.96$ mSv for 30 male patients respectably $6.29{\pm}0.97$ mSv, $10.02{\pm}2.42$ mSv and $9.05{\pm}2.27$ mSv for 30 female patients respectably. When using ImPACT v1.0, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.54{\pm}1.21$ mSv, $8.36{\pm}1.69$ mSv and $9.74{\pm}2.55$Sv for 30 male patients respectably $5.87{\pm}1.09$ mSv, $8.43{\pm}1.89$ mSv and $9.19{\pm}2.29$ mSv for female patients respectably. When divided three groups which were under 50 kg, 50~60 kg and over 60 kg respectably were 6.27 mSv, 7.67 mSv and 9.33 mSv respectably using CT-Expo V1.7, 5.62 mSv, 7.22 mSv and 8.91 mSv respectably using ImPACT v1.0. Weight and the effective dose coefficient analysis showed a very strong positive correlation(r=743, r=0.693). Conclusion: Using such a dose evaluation programs, easier to predict and evaluate the effective dose possible without performing phantom study and such dose evaluation programs could be used to collect basic data for CT dose management.

  • PDF