• Title/Summary/Keyword: Ge(001)

Search Result 116, Processing Time 0.022 seconds

Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT (PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가)

  • Choong-Woon Lee;Yeon-Wook You;Jong-Woon Mun;Yun-Cheol Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.47-54
    • /
    • 2023
  • Purpose PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 mm with matrix size 128×128, slice thickness 3.75 mm, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in Wilcoxon signed rank test results (P value<0.001). Conclusion PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

  • PDF

Utility of Water Intake to Reduce Stomach's Additional Shooting in PET/CT Test (PET/CT 검사에서 Stomach의 추가 촬영을 줄이기 위한 수분 섭취의 유용성)

  • Lee, Seung-Hwan;Bae, Seong-Bok;Jeong, Byeong-Gon;Lee, Gyu-Chan;Lee, Gwang-Cheol;Bae, Won-Gyu
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.81-85
    • /
    • 2011
  • Purpose: With the introduction of PET since 1994, test methods have made rapid progress. Accordingly, the studies on the diagnosis and treatment of cancer as well as treatment response evaluation PET test are useful. However, it is difficult to divide stomach lesions and secretion. The purpose of this study is to reduce additional shooting by dividing lesions and secretion of stomach. Materials and Method: This study aiming at total 228 cancer patients was conducted from Aug 18 to Sep. 10, 2010. Among them, 115 patients had a test without water intake before shooting from Aug. 8 to 31 and 113 had a test after drinking 500 cc water right before shooting from Sep. 1 to 10 The Discovery ST PET/CT (GE Healthcare, USA) was used, and pearson's chi-square test was conducted to analyze significance through SPSS (Ver.18). Results: Among the total 228 cancer patients, there were 115 who had a test without water intake before shooting, 89 who had no double additional shooting, 13 who had stomach additional shooting and 13 who had other additional shooting. In addition, 109 had no additional shooting among 113 who had a test after taking 500 cc water, 1 had stomach additional shooting and 3 had other additional shooting. According to the findings above, the patients who had a test without water intake show reduced additional shooting, but for more exact significance, pearson's Chi-square test was carried out and the significance percentage was 0.001 that is smaller than 0.05, which means two groups have a significant relationship. As the minimum expectation frequency was 6.94 and there was no expectation frequency smaller than 5, so that it doesn't need to carry out pearson's exact verification. Conclusion: The above analysis has found that if one drinks 500cc water before the test, not only stomach additional shooting but also other additional shooting can be dramatically reduced, and test delay can be also reduced.

  • PDF

Determination of Maintenance Energy Requirements for Growing Hanwoo Steers (육성기 거세한우의 유지에너지 요구량 결정에 관한 연구)

  • Seol, Yong-Joo;Kim, Kyoung-Hoon;Baek, Youl-Chang;Lee, Sang-Cheol;Ok, Ji-Un;Lee, Kang-Yeon;Hong, Seong-Koo;Jang, Sun-Sik;Choi, Chang-Weon;Song, Man-Kang;Lee, Sung-Sil;Oh, Young-Kyoon
    • Journal of Animal Science and Technology
    • /
    • v.53 no.2
    • /
    • pp.155-160
    • /
    • 2011
  • Present experiment was carried out to determine maintenance energy requirements for growing Hanwoo steers. Six Hanwoo steers (BW = $180.6{\pm}3.1$ kg) were used in two 3 ${\times}$ 3 latin square design with three different energy intake levels; TDN 1.70 kg (Low), 2.05 kg (Medium), 2.80 kg (High), respectively, based on the Korean Feeding Standards. Each period lasted 18 days including a 14-day adaptation and a 4-day measuring period. The steers were in the head hood chamber system (one cattle per chamber) during each measuring time to measure heat and methane production for 1 day. Dry matter intake was 2,058, 3,256 and 3,881 g/day for Low, Medium and High TDN, respectively. Increase in energy intake did not affect digestibilities of dry matter, crude protein, crude fiber, crude fat, NDF, ADF and nitrogen-free extract. Gross energy intake averaged 180.21, 292.74 and 337.15 kcal/$BW^{0.75}$ for Low, Medium and High TDN, respectively. Energy loss was 28.7% in feces and 2.1% in urine of gross energy intake. Further, energy loss from methane produced during rumen fermentation was 6~8.3%, while body heat loss averaged 34~60%. Intercept of regression equation between ME intake and retained energy indicated that the energy requirement was 109.84 kcal ME/$BW^{0.75}$.

The Differentiation of Malignant and Benign Musculoskeletal Tumors by F-18 FDG PET/CT Studies - Determination of maxSUV by Analysis of ROC Curve (F-18 FDG PET/CT에서 양성과 악성 근골격 종양의 감별진단 - 수신자 판단특성곡선을 이용한 maxSUV의 절단값 결정)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Choi, Jun-Heok;Shin, Duk-Seop
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.6
    • /
    • pp.553-560
    • /
    • 2007
  • Purpose: We evaluated the standard uptake value (SUV) of F-18 FDG at PET/CT for differentiation of benign from malignant tumor in primary musculoskeletal tumors. Materials and Methods: Forty-six tumors (11 benign and 12 malignant soft tissue tumors, 9 benign and 14 malignant bone tumors) were examined with F-18 FDG PET/CT (Discovery ST, GE) prior to tissue diagnosis. The maxSUV(maximum value of SUV) were calculated and compared between benign and malignant lesions. The lesion analysis was based on the transverse whole body image. The maxSUV with cutoff of 4.1 was used in distinguishing benign from malignant soft tissue tumor and 3.05 was used in bone tumor by ROC curve. Results: There was a statistically significant difference in maxSUV between benign (n=11; maxSUV $3.4{\pm}3.2$) and malignant (n=12; maxSUV $14.8{\pm}12.2$) lesions in soft tissue tumor (p=0.001). Between benign bone tumor (n=9; maxSUV $5.4{\pm}4.0$) and malignant bone tumor (n=14; maxSUV $7.3{\pm}3.2$), there was not a significant difference in maxSUV. The sensitivity and specificity for differentiating malignant from benign soft tissue tumor was 83% and 91%, respectively. There were four false positive malignant bone tumor cases to include fibrous dysplasia, Langerhans-cell histiocytosis (n=2) and osteoid osteoma. Also, one false positive case of malignant soft tissue tumor was nodular fasciitis. Conclusion: The maxSUV was useful for differentiation of benign from malignant lesion in primary soft tissue tumors. In bone tumor, the low maxSUV correlated well with benign lesions but high maxSUV did not always mean malignancy.

Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT (L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성)

  • Hyunsoo Ko;Soonki Park;Eunhye Kim;Jongsook Choi;Wooyoung Jung;Dongyun Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

The Comparison of $45^{\circ}$ and $55^{\circ}$ Anteroposterior Oblique View for Observating the Intervertebral Foramen (경추 추간공 관찰을 위한 촬영법의 고찰)

  • Jeon, Ju-Seob;Eun, Sung-Jong;Kim, Hye-Ran;An, Seung-Hyun;Choi, Nam-Kin;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.91-95
    • /
    • 2005
  • The cervical spine of anteroposterior oblique view is essential to observe the intervertebral foramen(IVF). The morphologic changes of IVFs were proved to be abnormal with nerve roots and peripheral structures. The purpose of this study is to evaluate the effective projection angle for observing the IVFs in the Korean adults. In a prospective clinical study of 100 normal persons, $45^{\circ}$, $50^{\circ}$ and $55^{\circ}$ oblique views were compared by measuring the maximal transverse diameter of all the cervical IVFs. $45^{\circ}$ oblique views provided slightly better visualization of upper cervical level(C2-C3, C3-C4, C4-C5), but the lower cervical level(C5-C6, C6-C7, C7-T1) of IVF transverse diameters were substantially increased on the $55^{\circ}$ AP oblique projection. In the comprasion of mean differences between 8 obese person(BMI > 25) and 58 normal person(18.5 < BMI < 22.9) proved to be statistically not significant. Consequently this study shows that $55^{\circ}$AP oblique(tube angle $15^{\circ}$cephalad) view is optimal for evaluating the lower cervical IVFs.

  • PDF